Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

COMPACTION OF FIBERBOARD IN A 9975 SHIPPING PACKAGE

Compaction of lower layers in the fiberboard overpack has been observed in 9975 packages that contain elevated moisture. Lab testing has resulted in a better understanding of (1) the relationship between the fiberboard moisture level and compaction of the lower fiberboard assembly, and (2) the behavior of the fiberboard during transport. In laboratory tests, higher moisture content has been shown to correspond to higher total compaction of fiberboard material, greater rate of compaction, and continued compaction over a longer period of time. In addition, laboratory tests have shown that the application of a dynamic load results in higher fiberboard compaction. The test conditions and sample geometric/loading configurations were chosen to simulate the regulatory requirements for 9975 package input dynamic loading. Dynamic testing was conducted over a period of several months to acquire immediate and cumulative changes in geometric data for various moisture levels. Currently, one sample set has undergone a complete dynamic test regimen, while testing of another set is still in-progress. The dynamic input, data acquisition, test effects on sample dynamic parameters, and interim results from this test program will be summarized and compared to regulatory specifications for dynamic loading. This will provide a basis from which to evaluate the impact of moisture and fiberboard compaction on the safety basis for transportation (Safety Analysis Report for Packaging) and storage (facility Documented Safety Analysis) at the Savannah River Site (SRS).

36 MATERIALS SCIENCE↗

Finite element analysis of the Arquin-designed CMU wall under a dynamic (blast) load.

The Arquin Corporation designed a CMU (concrete masonry unit) wall construction and reinforcement technique that includes steel wire and polymer spacers that is intended to facilitate a faster and stronger wall construction. Since the construction method for an Arquin-designed wall is different from current wall construction practices, finite element computer analyses were performed to estimate the ability of the wall to withstand a hypothetical dynamic load, similar to that of a blast from a nearby explosion. The response of the Arquin wall was compared to the response of an idealized standard masonry wall exposed to the same dynamic load. Results from the simulations show that the Arquin wall deformed less than the idealized standard wall under such loading conditions. As part of a different effort, Sandia National Laboratories also looked at the relative static response of the Arquin wall, results that are summarized in a separate SAND Report.

36 MATERIALS SCIENCE↗

Moisture Effects on Compaction of Fiberboard in a 9975 Shipping Package (Final Report)

Compaction of lower layers in the fiberboard assembly has been observed in 9975 packages that contain elevated moisture. Lab testing has resulted in a better understanding of the relationship between the fiberboard moisture level and compaction of the lower fiberboard assembly, and the behavior of the fiberboard during transport. In laboratory tests of cane fiberboard, higher moisture content has been shown to correspond to higher total compaction, greater rate of compaction, and continued compaction over a longer period of time. In addition, laboratory tests have shown that the application of a dynamic load results in higher fiberboard compaction compared to a static load. The test conditions and sample geometric/loading configurations were chosen to simulate the regulatory requirements for 9975 package input dynamic loading. Dynamic testing was conducted to acquire immediate and cumulative changes in geometric data for various moisture levels. Two sample sets have undergone a complete dynamic test regimen, one set for 27 weeks, and the second set for 47 weeks. The dynamic input, data acquisition, test effects on sample dynamic parameters, and results from this test program are summarized and compared to regulatory specifications for dynamic loading. Compaction of the bottom fiberboard layers due to the accumulation of moisture is one possible cause of an increase in the axial gap at the top of the package. The net compaction of the bottom layers will directly add to the axial gap. The moisture which caused this compaction migrated from the middle region of the fiberboard assembly (which is typically the hottest). This will cause the middle region to shrink axially, which will also contribute directly to the axial gap. Measurement of the axial gap provides a screening tool for identifying significant change in the fiberboard condition. The data in this report provide a basis to evaluate the impact of moisture and fiberboard compaction on 9975 package performance during storage at the Savannah River Site (SRS).

36 MATERIALS SCIENCE↗

In-Situ Blade Strain Measurements and Fatigue Analysis of a Cross-Flow Turbine Operating in a Tidal Flow

Cross-flow turbines (CFTs) are inherently unsteady devices with regards to operating principle and loading. By improving our understanding of the dynamic loading on these turbines, we hope to better inform CFT design, improve survivability, and reduce overall costs. The University of New Hampshire (UNH) and the National Renewable Energy Laboratory (NREL) collaborated on a project to instrument and test a four-bladed New Energy Corp. vertical axis cross-flow turbine in a real tidal flow. One blade from the 3.2 m diameter x 1.7 m height turbine was instrumented with eight full-bridge strain gauges along the span of the blade. The turbine was then deployed at the UNH-Atlantic Marine Energy Center (AMEC) Tidal Energy Test Site in Portsmouth, NH. Time-synchronized measurements of blade strain, inflow, thrust, rotational speed, and electrical output were obtained to characterize blade loading under various conditions. The blade strain was examined to assess the dynamic loading and conduct a fatigue analysis on the device.

blade strain↗

Nucleation and growth of damage in polycrystalline aluminum under dynamic tensile loading

Plate-impact experiments were conducted to study the features and mechanisms of void nucleation and growth in the polycrystalline of pure aluminum under dynamic loading. Soft-recovered samples have been analyzed by metallographic microscopy, electron back scattering diffraction (EBSD), and synchrotron radiation x-ray tomography technology. It was found that most of the void nucleation in grains neared the boundaries of “weak-orientation” grains and grew toward the grain boundaries with fractured small grains around the boundaries. This was mainly caused by the accumulation and interaction of slip systems in the “weak-orientation” grains. In addition, the micro voids were nearly octahedron because the octahedral slip systems were formed by 8 slip planes in the polycrystalline of pure aluminum. The EBSD results are consistent with the three-dimensional structure observed by synchrotron radiation x-ray.

36 MATERIALS SCIENCE↗

Reliability Implications of Solder in Multiwire Modules under Dynamic Mechanical Loading

Two generations of multiwire modules were studied under dynamic mechanical loading (DML) with in-situ differential conductance (dG) and electroluminescence (EL) imaging. Energy-dispersive x-ray spectroscopy (EDS) was used to identity the solder alloys. The earlier generation module was found to use an In-based solder alloy, and the current generation a Bi-based alloy. The earlier generation module degraded significantly under DML with increasing resistance, while the current generation module did not demonstrate degradation under DML. Atomic force microscopy scratch testing was used to probe the wear resistance of each solder alloy. These results indicate that current multiwire designs may have higher mechanical durability than earlier generations.

atomic force microscopy↗

Evaluation of Dynamic Mechanical Loading as an Accelerated Test Method for Ribbon Fatigue

Dynamic Mechanical Loading (DML) of photovoltaic modules is explored as a route to quickly fatigue copper interconnect ribbons. Results indicate that most of the interconnect ribbons may be strained through module mechanical loading to a level that will result in failure in a few hundred to thousands of cycles. Considering the speed at which DML may be applied, this translates into a few hours o testing. To evaluate the equivalence of DML to thermal cycling, parallel tests were conducted with thermal cycling. Preliminary analysis suggests that one +/-1 kPa DML cycle is roughly equivalent to one standard accelerated thermal cycle and approximately 175 of these cycles are equivalent to a 25-year exposure in Golden Colorado for the mechanism of module ribbon fatigue.

14 SOLAR ENERGY↗

Evaluation of Dynamic Mechanical Loading as an Accelerated Test Method for Ribbon Fatigue

Dynamic Mechanical Loading (DML) of photovoltaic modules is explored as a route to quickly fatigue copper interconnect ribbons. Results indicate that most of the interconnect ribbons may be strained through module mechanical loading to a level that will result in failure in a few hundred to thousands of cycles. Considering the speed at which DML may be applied, this translates into a few hours of testing. To evaluate the equivalence of DML to thermal cycling, parallel tests were conducted with thermal cycling. Preliminary analysis suggests that one +/-1 kPa DML cycle is roughly equivalent to one standard accelerated thermal cycle and approximately 175 of these cycles are equivalent to a 25-year exposure in Golden Colorado for the mechanism of module ribbon fatigue.

14 SOLAR ENERGY↗

Nonuniform and localized deformation in single crystals under dynamic tensile loading

Nonuniform and localized deformation in planar single crystals subjected to dynamic tensile loading is investigated here using finite element method. An idealized planar double-slip model is used to represent the crystal geometry. A size-dependent higher-order gradient crystal plasticity theory accounting for finite strains is adopted to characterize the material. The problem involves two kinds of length scale effect. One is naturally introduced by the inertial effect. The other is the intrinsic material length scale that is related to plastic strain gradients, which are related to a density of geometrically necessary dislocations. For size-independent conventional crystal plasticity, the deformation mode changes from an imperfection-induced (quasi static-like) mode to an imperfection-ignoring mode at some imposed velocity. When the higher-order gradient theory is used, the behavior is more complex with the variation in deformation mode with imposed velocity not necessarily monotonic due to the interaction between the two length scales (an inertia related length scale and a material length scale) affecting the response.

36 MATERIALS SCIENCE↗

Reliability Implications of Solder in Multiwire Modules under Dynamic Mechanical Loading: Preprint

Two generations of multiwire modules were studied under dynamic mechanical loading (DML). The earlier generation module was found to use an In-based solder alloy, and the current generation a Bi-based alloy. The earlier generation module degraded significantly under DML with increasing resistance, while the state-of-the-art module did not demonstrate degradation under DML. The degradation in the earlier module was attributed to damage at the solder-gridline interfaces. Atomic force microscopy scratch testing estimated the wear resistance of each solder alloy to assess susceptibility to degradation. Bi-based alloys appear to be more wear resistant than In-based alloys, consistent with the DML results. These results indicate that current multiwire designs may have higher mechanical durability than earlier generations.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Rate-dependent strength and deformation heterogeneity of B4C-reinforced Al composite: Time-resolved imaging with synchrotron X-rays

Dynamic (up to 5500 s -1 ) and quasi-static compression tests are conducted on a 15 wt% B4C particle-reinforced Al (B 4 C/Al) composite. In situ, high-speed synchrotron X-ray phase contrast imaging and digital image correlation are employed to map mesoscale deformation fields at μm and μs scales. The bulk stress–strain curves show significant strain and strain-rate hardening under dynamic compression. The strain-rate sensitivity exponent is an order of magnitude higher at high strain rates (> 10 3 s -1 ) than that at low strain rates (< 10 -2 s -1 ). Strain field mapping demonstrates distinct compressive strain localizations for both quasi-static and dynamic loading. Nevertheless, compressive strain localizations appear denser in spacing under dynamic loading, owing to spontaneous dislocation nucleation in both weak and strong zones. This results in a higher density of geometrically necessary dislocations, which contributes to the higher strain and strain-rate hardening of B 4 C/Al under dynamic loading. Additionally, the ratio of the maximum local strain to the bulk average is 1.5, and the local strain-rate enhancement cannot explain the increased rate sensitivity of B 4 C/Al under dynamic loading. Therefore, the rate-dependent deformation heterogeneity dominates the strain-rate hardening of B 4 C/Al. Postmortem analyses help correlate deformation features to particle- and grain-scale microstructures, yielding consistent results with mesoscale strain fields.

36 MATERIALS SCIENCE↗

Dynamic Wind Loading on CSP Collectors Caused by Turbulent Wind Fluctuations: Insights from a 2-Year Field Campaign

Concentrating Solar Power (CSP) is a promising solar technology for electricity generation with thermal energy storage and with the additional benefit of industrial heat production. Wind loading on CSP collector structures, such as parabolic troughs or heliostats, is one of the primary drivers of their structural design costs. In particular, dynamic wind loading is a major source of uncertainty in the collector design process, which heavily relies on wind tunnel testing. In the field, the turbulent nature of the incoming wind creates fluctuating loads (support structure loads and resulting mirror deflections) on the collectors, with impacts on fatigue lifetime and optical performance. As is well known, wind tunnel tests cannot entirely reproduce the complex turbulent wind conditions typically observed at full-scale plants. To shed light on this topic, NREL initiated a field campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs. We use the published 2-year dataset of high-resolution combined wind and structural loads measurements [1] to characterize the dynamic structural wind response. For quantifying dynamic wind loading, we apply the concept of admittance functions, which are spectral transfer functions that couple the turbulent wind to resulting structural loads (aerodynamic admittance), and to the structural response (mechanical admittance). In practice, aerodynamic admittance describes which turbulent eddy sizes are effective in creating structural loads. The mechanical admittance describes in which frequency ranges these loads are reinforced or dampened by the structure. While these functions are an established concept in civil engineering, their recent application to a single full-scale heliostat [2] proved their broader applicability to CSP collectors. Here, we present a characterization of admittance functions for full-scale parabolic trough collectors and show how wind characteristics (mean wind speed and direction, turbulent kinetic energy, turbulent length scales), the sun-tracking trough angle, and row position alter the admittance functions. Further, we study to which extent the admittance functions are universal for a specific trough geometry and how our findings compare to reported heliostat results. References [1] https://data.openei.org/submissions/5938. [2] Blume, K., Roger, M., and Pitz-Paal, R. 2023b. "Simplified analytical model to describe wind loads and wind-induced tracking deviations of heliostats." Solar Energy, 256, 96-109. https://doi.org/10.1016/j.solener.2023.03.055.

admittance functions↗

Prediction of Debye-Scherrer diffraction patterns in arbitrarily strained samples

The prediction of Debye-Scherrer diffraction patterns from strained samples is typically conducted in the small strain limit. Although valid for small deviations from the hydrostat (such as the conditions of finite strength typically observed in diamond anvil cells) this assertion is likely to fail for the large strain anisotropies (often of order 10% in normal strain) found in uniaxially loaded dynamic compression experiments. In this paper, we derive a general form for the (θ{sub B},ϕ) dependence of the diffraction for an arbitrarily deformed polycrystalline sample in any geometry, and of any crystal symmetry. We show that this formula is consistent with ray traced diffraction for highly strained computationally generated polycrystals, and that the formula shows deviations from the widely used small strain solutions previously reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

COMPACTION OF FIBERBOARD OVERPACK MATERIALS IN A 9975 SHIPPING PACKAGE

Compaction of lower layers in the 9975 fiberboard overpack has been observed in packages that contain excess moisture. Dynamic loading of the package during transportation may also contribute to compaction of the fiberboard. This condition is being tested and analyzed to better understand these compaction mechanisms and provide a basis from which to evaluate their impact to the safety basis for transportation (Safety Analysis Report for Packaging) and storage (facility Design Safety Analysis) at the Savannah River Site (SRS). A test program has been developed and is being implemented to identify the extent of the compaction as a function of fiberboard moisture and typical transport dynamic loadings. Test conditions will be compared to regulatory requirements for dynamic loading. Characterization of the recovery of short-term compaction following the application of dynamic loading is also being evaluated. Interim results from this test program will be summarized.

42 ENGINEERING↗

The deformation and failure response of closed-cell PMDI foams subjected to dynamic impact loading

The present work aims to investigate the bulk deformation and failure response of closed-cell Polymeric Methylene Diphenyl Diisocyanate (PMDI) foams subjected to dynamic impact loading. First, foam specimens of different initial densities are examined and characterized in quasi-static loading conditions, where the deformation behavior of the samples is quantified in terms of the compressive elastic modulus and effective plastic Poisson's ratio. Then, the deformation response of the foam specimens subjected to direct impact loading is examined by taking into account the effects of material compressibility and inertia stresses developed during deformation, using high speed imaging in conjunction with 3D digital image correlation. The stress-strain response and the energy absorption as a function of strain rate and initial density are presented and the bulk failure mechanisms are discussed. As a result, it is observed that the initial density of the foam and the applied strain rates have a substantial influence on the strength, bulk failure mechanism and the energy dissipation characteristics of the foam specimens.

36 MATERIALS SCIENCE↗

Gas gun shock experiments with single-pulse x-ray phase contrast imaging and diffraction at the Advanced Photon Source

The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for in situ, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal (<100 ps) and spatial ({approx}2 {mu}m) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of SCRF cavity dynamic heat load in horizontal test system

The Horizontal Test System (HTS) at Fermilab is currently testing fully assembled, dressed superconducting radio frequency (SCRF) cavities. These cavities are cooled in a bath of superfluid helium at 1.8K. Dissipated RF power from the cavities is a dynamic heat load on the cryogenic system. The magnitude of heat flux from these cavities into the helium is also an important variable for understanding cavity performance. Methods and hardware used to measure this dynamic heat load are presented. Results are presented from several cavity tests and testing accuracy is discussed.

43 PARTICLE ACCELERATORS↗

Microstructure in the extreme environment: understanding and predicting dynamic damage processes

The future of materials science: strategic application for functionally controlled materials properties is emphasized by the need to control material performance in extreme environments. To this end, this study examines the separate effects of kinetics (in the form of dynamic loading rate and shock wave shape) from that of length-scale effects (in the form of microstructural defect distributions). Recently available mesoscale modeling techniques are being used to capture a physical link between kinetic and length-scale influences on dynamic loading. This work contributes innovative new tools in the form of shock-wave shaping techniques in dynamic experimentation, materials characterization, lending insight into 3D damage field analysis at micron resolution, and the physics necessary to provide predictive capabilities for dynamic damage evolution. Experimental results tailored for the discreet understanding of length-scale and kinetic effects during dynamic loading are obtained to provide the basis for the development of process-aware material performance models. The understanding of length-scale and kinetic effects in extreme environments of dynamic loading advances the understanding of current emerging issues relevant to phenomena such as inclusion related failure in metals, grain size dependence on ejecta, and benefits of interfaces in mitigating defect development specifically driven by the need to tailor material response. Finally, the coupling of experimental techniques with theory and simulation is aimed at advancing process-aware damage modeling as well as transitioning materials science from observation to property control.

36 MATERIALS SCIENCE↗