Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Scaffolding matrix with internal nanoparticles

A battery electrode composition is provided comprising composite particles, with each composite particle comprising active material and a scaffolding matrix. The active material is provided to store and release ions during battery operation. For certain active materials of interest, the storing and releasing of the ions causes a substantial change in volume of the active material. The scaffolding matrix is provided as a porous, electrically-conductive scaffolding matrix within which the active material is disposed. In this way, the scaffolding matrix structurally supports the active material, electrically interconnects the active material, and accommodates the changes in volume of the active material.

Yushin, Gleb↗

Fitness-for-Service Analysis of Reactor Components under Flexible Load-Following Operating Conditions

Conventional power-generation plants, including nuclear plants, have been traditionally designed to provide a steady baseload energy capacity, optimizing output efficiency while minimizing variable costs. However, the growing adoption of large-scale renewable energy-generation systems, which rely on intermittent sources such as solar and wind, has introduced more variability into the energy supply in interconnected electricity grids. As a result, the next generation of power plants needs to operate in what is known as the load-following mode, requiring flexible adjustments in electricity production to align with the energy demand on the grid. This transition from the steady baseload operation to load-following operating conditions can significantly increase the number of times various plant components are exposed to transient stresses. This increased thermo-mechanical cycling can lead to accelerated material degradation, thereby elevating the risk of premature failure of a component. It becomes imperative to conduct a comprehensive analysis of fatigue, creep-fatigue, and stress corrosion cracking life, to assess the resilience of the various engineering components under these flexible load-following operating conditions. This study aims to develop a comprehensive numerical model of a light-water reactor pressure vessel (RPV) to investigate its degradation under various operating scenarios. This coupled thermo-mechanical finite element analysis evaluated the stress response of the RPV caused by considering fluctuations in thermal and mechanical loads caused by the varying pressure and temperature occurring during the load-following operation. Critical locations on the RPV are subsequently identified based on the stress response. The stress intensity factors for the postulated flaws at those locations are then calculated, followed by an evaluation of the reactor's life in accordance with the ASME Boiler and Pressure Vessel Code Section XI. This comprehensive life assessment covers a number of transients expected during the flexible load-following operation, providing invaluable insights into the RPV's structural integrity. Moreover, the development methodology can be adapted to other reactor components, as well as components of conventional power stations that are affected by varying operating conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Linear viscoelastic characterization of electrically conductive adhesives used as interconnect in photovoltaic modules

Electrically conductive adhesives (ECAs) are incorporated into recent designs of photovoltaic (PV) modules and replace the traditional metallic solders as interconnects. This transition depicts a significant material change, and a proper understanding of the interconnects' mechanical response has not yet been established. However, such an understanding is necessary to (a) identify the driving forces for module degradation and failure, (b) allow for module design optimization, and (c) enable accurate lifetime predictions. This study summarizes the framework for the mechanical materials characterization and modeling of ECAs for PV applications. Only high-fidelity material models are able to capture the rate and temperature dependency of the ECA interconnect and allow for accurate modeling of the materials response. Furthermore, a linear viscoelastic representation is found to describe the mechanical response of the ECAs sufficiently well. The effects of curing conditions and environmental exposure are investigated, and material models for a variety of ECAs are reported and prepared for the use in numerical simulations. Overall, a finite element simulation of a generic submodel of a shingled cell module is used to highlight the need for high-fidelity material models and demonstrates the error made in the predicted stress states by using less sophisticated models.

14 SOLAR ENERGY↗

Analysis of Electrical Grid Capacity by Interconnection for Urban Air Mobility

A wide range of challenges must be overcome to conduct Urban Air Mobility (UAM)operations at scale with electric vertical take-off and landing aircraft as envisioned. This paper documents an analysis of one potential infrastructure challenge for UAM: available electrical grid power capacity. The success of UAM depends on the availability of electricity, which will be increasingly impacted by the proliferation of ground electric vehicles(EVs) over time. Under the best-case assumption that electricity can be transmitted and distributed as needed within each interconnection (i.e., electrical grid), it is estimated that the maximum number of UAM aircraft that can charge simultaneously in the continental United States will decrease by 20% from about 595 thousand in the year 2021 to about 475 thousand in the year 2050due to the projected increase in ground EVs.

electrical grid↗

Analysis of Electrical Grid Capacity by Interconnection for Urban Air Mobility

A wide range of challenges must be overcome to conduct Urban Air Mobility (UAM)operations at scale with electric vertical take-off and landing aircraft as envisioned. This paper documents an analysis of one potential infrastructure challenge for UAM: available electrical grid power capacity. The success of UAM depends on the availability of electricity, which will be increasingly impacted by the proliferation of ground electric vehicles(EVs) over time. Under the best-case assumption that electricity can be transmitted and distributed as needed within each interconnection (i.e., electrical grid), it is estimated that the maximum number of UAM aircraft that can charge simultaneously in the continental United States will decrease by 20% from about 595 thousand in the year 2021 to about 475 thousand in the year 2050due to the projected increase in ground EVs.

electrical grid↗

Interconnected Risks in Electricity Systems: Understanding Research Challenges, Needs, and Partnerships

The U.S. federal government has a potential role in mitigating the most poorly addressed risks across electricity markets and interdependent systems. Electricity system risks stem from extreme acute shocks (e.g., cyberattacks, extreme weather, and supply chain disruptions) and chronic stressors (e.g., global economic competition, uncertainties surrounding emerging technologies, climate change, and related conflicts). These acute shocks and chronic stressors can result in dire consequences for society, underscoring the need for better information for decision makers in both public and private sectors. Best practices and a shared understanding of risk management and risk quantification must be rapidly developed and disseminated. Informed by a quantitative treatment of risk to electrical infrastructure and interdependent systems, decision makers can more prudently and efficiently prioritize mitigation initiatives to maximize benefits to government, businesses, and the public.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Interfacial characteristics of metal clad polymeric substrates on electrical high frequency interconnection performance

Etched metallic conductor lines on metal clad polymeric substrates are used for electronic component interconnections. Significant signal losses are observed for microstrip conductor lines used for interconnecting high frequency devices. At these frequencies, the electronic signal travels closer to the metal-polymer interface due to the skin effect. Copper-teflon interfaces were characterized by scanning electron microscopy (SEM) and Auger electron spectroscopy (AES) to determine the interfacial properties. Data relating roughness of the copper film to signal losses was compared to theory. Films used to enhance adhesion are found, to contribute to these losses.

Bhasin, K. B.↗

Energy-water interdependencies across the three major United States electric grids: A multi-sectoral analysis

As water availability and timing of delivery fluctuates and the US electric grid sees rapid transformation and reconfiguration under decarbonization and resource adequacy strategies, there is a critical need for information and data that supports understanding the water-energy interdependency landscape. The United States currently lacks comprehensive data, informative visualizations, and analysis of energy-water interdependencies at scales necessary to support resource and operational decision-making. This article provides US electricity interconnection-level Sankey diagrams that show the relative reliance of water and energy across various economic sectors. A deeper analysis is additionally provided at the county level to illustrate trends and potential opportunities related to resiliency and efficiency in multi-sectoral water and energy flow distributions and intensities. We find that the electricity interconnections in the US vary dramatically in their water and energy interdependencies across applications and economic sectors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flexible neural interfaces with integrated stiffening shank

A neural interface includes a first dielectric material having at least one first opening for a first electrical conducting material, a first electrical conducting material in the first opening, and at least one first interconnection trace electrical conducting material connected to the first electrical conducting material. A stiffening shank material is located adjacent the first dielectric material, the first electrical conducting material, and the first interconnection trace electrical conducting material.

36 MATERIALS SCIENCE↗

Flexible neural interfaces with integrated stiffening shank

A neural interface includes a first dielectric material having at least one first opening for a first electrical conducting material, a first electrical conducting material in the first opening, and at least one first interconnection trace electrical conducting material connected to the first electrical conducting material. A stiffening shank material is located adjacent the first dielectric material, the first electrical conducting material, and the first interconnection trace electrical conducting material.

36 MATERIALS SCIENCE↗

Modeling Power Plant Siting Opportunities and Constraints in the Eastern Interconnection

The electrical transmission grid is a critical part of the U.S. national infrastructure, and its modernization is a U.S. Department of Energy (DOE) priority. We describe the Energy Zones Mapping Tool (EZMT), a unique, powerful, and public web-based system with multi-criteria decision analysis (MCDA) models for more than 20 power plant technologies and many other capabilities. Through a case study on natural gas combined cycle (NGCC) power plants in the Eastern Interconnection (EI), we provide an example of incorporating an EZMT MCDA model into a larger planning context, with projections of interconnection-level capacity expansion, thermoelectric power plant retirements, and water availability. Our results provide insights on candidate NGCC site distributions and the criteria influencing them. The case study provides both an efficient methodology for performing similar analyses and hundreds of candidate NGCC power plant sites that can be studied in more detail as potential project sites.

20 FOSSIL-FUELED POWER PLANTS↗

Small Hydropower Interconnections: State Interconnection Processes

Small hydropower projects with rated power output between 0 to 20 MW have been the predominant source of hydropower growth over the past decade in the United States (DOE 2016; Johnson et al. 2018). However, interconnection to electricity distribution and transmission grids is a persistent barrier. Interconnection of an electricity generating unit is overseen by the distribution or transmission owner, who use interconnection standards and requirements that vary by state. The differences between standards in standards may affect the final cost, timeline, and success of a small hydropower project. Small hydropower project developers across the United States have found interconnection procedures to be fraught with cost surprises and schedule overruns. System operators have struggled to understand impacts to overburdened or rapidly evolving transmission and distribution grids. The results of these shortcomings have been stranded costs and unrealized small hydropower potential. Though regulatory actions and policy recommendations at the state level have increased the situational awareness of interconnection challenges, the remote locations of small hydropower resources and the relatively small revenues associated with energy production through small hydropower facilities continue to make interconnection processes and requirements confusing and costly. Noting these challenges, the U.S. Department of Energy Water Power Technologies Office enlisted Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to investigate the small hydropower interconnection landscape across the United States. The second in a series, this paper investigates the interconnection process in each state in the U.S. to compare their attributes. Subsequent papers in the series will analyze these interconnection processes (“Small Hydropower Interconnections: Analysis of Interconnection Processes”) and present best practices (“Small Hydropower Interconnections: Best Practices”) that will help overcome barriers to future small hydropower development. The first paper in the series examined the state of small hydropower projects in the United States (“Small Hydropower Interconnections: Small Hydropower in the United States”) to understand the industry characteristics.

13 HYDRO ENERGY↗

Impacts of Spatial Resolution in a High-Fidelity Capacity Expansion Model: An ERCOT Case Study

Capacity expansion models are important tools in examining the evolution of the electric power sector. Embedded in these tools are many modeling choices with consequential impacts on computational burden and associated analysis. In this study, we adjust the spatial resolution of the Regional Energy Deployment System (ReEDS) to understand the implications of higher-fidelity modeling on energy system projections and model solve times. The native ReEDS regions capture the contiguous United States in 134 balancing areas whereas the regions in the higher-resolution version are defined by over 3,000 U.S. counties. Using both resolutions, we conduct a case study of the Texas Interconnection (The Electric Reliability Council of Texas [ERCOT]) to explore differences in model projections and to inform appropriate applications of high spatial resolution in a large-scale, applied capacity expansion model.

county↗

Fluid delivery manifolds and microfluidic systems

Embodiments of fluid distribution manifolds, cartridges, and microfluidic systems are described herein. Fluid distribution manifolds may include an insert member and a manifold base and may define a substantially closed channel within the manifold when the insert member is press-fit into the base. Cartridges described herein may allow for simultaneous electrical and fluidic interconnection with an electrical multiplex board and may be held in place using magnetic attraction.

42 ENGINEERING↗

Interconnect system with friction fit backshell

Various technologies described herein pertain to interconnect systems for electrical cables. An interconnect system can include a connector, an adapter ring, and a backshell. The connector includes a threaded distal coupling portion. The adapter ring includes a threaded proximal coupling portion and a non-threaded distal coupling portion. The backshell includes a proximal coupling portion and a port. The threaded proximal coupling portion of the adapter ring and the threaded distal coupling portion of the connector can be mechanically attached. Additionally, the proximal coupling portion of the backshell and the non-threaded distal coupling portion of the adapter ring can be mechanically attached. A wire bundle can enter the backshell through the port, pass through the adapter ring, and terminate at the connector. A shield that encloses the wire bundle can terminate at the backshell such that an end of the shield is positioned around an outer surface of the port.

42 ENGINEERING↗

Interconnect system with friction fit backshell

Various technologies described herein pertain to interconnect systems for electrical cables. An interconnect system can include a connector, an adapter ring, and a backshell. The connector includes a threaded distal coupling portion. The adapter ring includes a threaded proximal coupling portion and a non-threaded distal coupling portion. The backshell includes a proximal coupling portion and a port. The threaded proximal coupling portion of the adapter ring and the threaded distal coupling portion of the connector can be mechanically attached. Additionally, the proximal coupling portion of the backshell and the non-threaded distal coupling portion of the adapter ring can be mechanically attached. A wire bundle can enter the backshell through the port, pass through the adapter ring, and terminate at the connector. A shield that encloses the wire bundle can terminate at the backshell such that an end of the shield is positioned around an outer surface of the port.

42 ENGINEERING↗

Fluid delivery manifolds and microfluidic systems

Embodiments of fluid distribution manifolds, cartridges, and microfluidic systems are described herein. Fluid distribution manifolds may include an insert member and a manifold base and may define a substantially closed channel within the manifold when the insert member is press-fit into the base. Cartridges described herein may allow for simultaneous electrical and fluidic interconnection with an electrical multiplex board and may be held in place using magnetic attraction.

42 ENGINEERING↗