Dielectric Response of Cross-Linked Polyethylene (XLPE) Cable Insulation Material to Radiation and Thermal Aging

This work seeks dielectric indicators of the aged state of cross-linked polyethylene (XLPE) that has been simultaneously irradiated and thermally aged. The XLPE samples studied here were of the same material formulation as XLPE insulation found in RSCC I46-0021 instrumentation cable, formed into tapes with dimensions approximately 20 × 0.7 × 100 mm 3 . Aging was conducted by suspending the samples from a rack within an oven and subsequently exposing oven and samples to gamma radiation. Samples were aged at 60, 90, and 115 °C, with gamma-radiation dose rates from 0 to 450 Gy/h with total received doses from 0 to 216 kGy. The dielectric spectra of these samples were measured over the frequency range 1 Hz to 1 MHz using custom electrodes and a Novocontrol dielectric spectrometer before dielectric breakdown strength was measured on the same samples. Dielectric loss tangent was observed to increase as a function of dose, dose rate and exposure time for XLPE samples exposed as described above. Dielectric loss tangent did not, however, show sensitivity to thermal aging for the range of temperatures studied. Dielectric breakdown strength initially increased as the material oxidized, then decreased for more extreme aging, due to chain scission. It is concluded that dielectric loss tangent is a promising indicator of XLPE aging due to gamma radiation exposure.

dielectric losses, dielectric breakdown, cable ins↗

Surface Dynamics of Charge Transport in LaAlO 3 /SrTiO 3 with Time-Resolved Kelvin Probe Force Microscopy

Time-resolved Kelvin probe force microscopy (tr-KPFM) was used to map surface potential dynamics in LAO/STO under its critical thickness, where it acts as an insulator, as polarizing and depolarizing electric fields were applied to planar electrodes in ambient conditions. Two time constants, for polarization and relaxation (i.e., depolarization) each, were derived and were shown to be independent of the direction of electrical field, revealing the reproducibility and recovery of the surfaces. Ambient aging or recent electrical history did not change the surface kinetics as determined by tr-KPFM. During polarization, the faster time constant (~3–6 s) is likely associated with the transport of H+ ions through the full length of the channel. The slower time constant (~40–50 s), on the other hand, is observed across only half the channel width near the higher-potential–more positive–electrode, which is likely associated with an electrochemical reaction such as the dissociation of water. This slower time constant drops to ~10–20 s toward the middle of the channel which could represent the transport of OH– ions. Furthermore, during relaxation, the fast time constant is consistent with polarization and is correlated to the same mechanism while the slower time constant is higher than it was during polarization and may represent the reabsorption of moisture from the atmosphere.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mapping of Heterogeneous Catalyst Degradation in Polymer Electrolyte Fuel Cells

Pt catalysts in polymer electrolyte fuel cells degrade heterogeneously as the catalyst particles are exposed to local variations throughout the catalyst layer during operation. State-of-the-art analytical techniques for studying degradation of Pt catalysts do not possess fine spatial resolution to elucidate such non-uniform degradation behavior at a large electrode level. A new methodology is developed to spatially resolve and quantify the heterogeneous Pt catalyst degradation over a large area (several cm ) of aged MEAs based on synchrotron X-ray microdiffraction. PEFC single cells are aged using voltage cycling as an accelerated stress test and the degradation heterogeneity at a micrometer length scale is visualized by mapping Pt catalyst particle size after voltage cycling. It is demonstrated in detail that the Pt catalyst particle size growth is non-uniform and follows the flow field geometry. The Pt particle size growth is greater in the area under the flow field land, while it is minimal in the area under the flow field channel. Additional non-uniformity is observed with the Pt particle size increasing more rapidly at the air outlet area than the Pt particle size at the inlet area.

36 MATERIALS SCIENCE↗

Combining Spatial and Temporal Resolution in Cryo-TEM of Device Materials: Preprint

Cryogenic transmission electron microscopy (cryo-TEM) has been instrumental to reducing the effects of electron-beam sample interactions and enabling higher spatial resolution studies of beam sensitive materials. However, the process of thinning and freezing samples for cryo-TEM characterization is often complex and frequently involves removing materials from their environment or stimuli of interest for extended times. This can allow for structural relaxation, diffusion, and other dynamic processes to occur prior to characterization; for energy materials like battery electrodes, this makes it difficult to precisely correlate the imaged structure with native structures that evolve in-situ during device processing, operation, or aging. Here, we present methods to prepare cryo-TEM samples from energy materials during these critical processes in the relevant device lifetimes. This offers insights into improving the temporal resolution of cryo-TEM, while still exploiting its ability to achieve high spatial resolutions in characterizing beam sensitive materials.

BASIC BIOLOGICAL SCIENCES,MATERIALS SCIENCE↗

Treatment of Small Hepatocellular Carcinoma (≤2 cm) in the Caudate Lobe with Sequential Transcatheter Arterial Chemoembolization and Radiofrequency Ablation

PurposeTo evaluate technical feasibility and treatment results of sequential transcatheter arterial chemoembolization (TACE) and cone-beam computed tomography-guided percutaneous radiofrequency ablation (CBCT-RFA) for small hepatocellular carcinoma (HCC) in the caudate lobe.Materials and MethodsInstitutional review board approved this retrospective study. Radiologic database was searched for the patients referred to perform TACE and CBCT-RFA for small caudate HCCs (≤2 cm) between February 2009 and February 2014. A total of 14 patients (12 men and 2 women, mean age; 61.3 years) were included. Percutaneous ultrasonography-guided RFA (pUS-RFA) and surgery were infeasible due to poor conspicuity, inconspicuity or no safe electrode pathway, and poor hepatic reserve. Procedural success (completion of both TACE and CBCT-RFA), technique efficacy (absence of tumor enhancement at 1 month after treatment), and complication were evaluated. Treatment results including local tumor progression (LTP), intrahepatic distant recurrence (IDR), overall survival (OS), and progression-free survival (PFS) were analyzed.ResultsProcedural success and technique efficacy rates were 78.6 % (11/14) and 90.9 % (10/11), respectively. Average follow-up period was 45.3 months (range, 13.4–64.6 months). The 1-, 3-, and 5-year LTP probabilities were 0, 12.5, and 12.5 %, respectively. IDR occurred in seven patients (63.6 %, 7/11). The 1-, 3-, and 5-year PFS probabilities were 81.8, 51.9, and 26 %, respectively. The 1-, 3-, and 5-year OS probabilities were 100, 80.8, and 80.8 %, respectively.ConclusionCombination of TACE and CBCT-RFA seems feasible for small HCC in the caudate lobe not amenable to pUS-RFA and effective in local tumor control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flexible Fabric-Based IDC Sensors for Conformal Curved Surface Applications

Interdigital capacitor (IDC) sensors are attractive in-situ sensors that can be used to measure permittivity variations in materials. Such sensors could be powerful enablers for cable insulation aging detection. Since insulation aging is correlated with a change in its material permittivity an IDC can measure that change via its measured capacitance. A new thin, flexible fabric-based IDC sensor is introduced for application on conformal curved surfaces such as an electrical cable surface. A multielectrode IDC and its backplane were fabricated using conductive copper polyester taffeta fabrics that were adhesively bonded to nonconductive polyester fabric. The sensor because of its soft flexible structure eliminates the problem of sensor conductor damage which is common for printed circuit board (PCB) type sensors when conformed to the surface of a cable. It also significantly reduces the airgap between the electrodes and the surface that they must contact in order to measure the capacitance. Airgap reduction and consistency are important in order to accurately predict permittivity variations in cable insulation material due to aging. Both PCB-based sensors and the new fabric-based sensors were built and tested on unaged cables and cables that underwent accelerated aging. Results demonstrate the proposed advantages of the novel fabric-based IDC sensor.

interdigital capacitor sensor, IDC, NDE, PCB senso↗

Direct template synthesis of mesoporous carbon and its application to supercapacitor electrodes

A direct templating method which is facile, inexpensive and suitable for the large scale production of mesoporous carbon is reported herein. A meso-structure surfactant/silicate template was made in a solution phase and resorcinol-formaldehyde as a carbon precursor was incorporated into the template solution. After aging, carbonization and hydrofluoric acid (HF) etching, mesoporous carbon was obtained. Using X-ray diffraction, scanning and transmission electron microscopy and nitrogen sorption, the synthesis mechanism of the mesoporous carbon was elucidated. According to the small angle X-ray scattering measurements, the surface became smoother after the removal of the silica, indicating that the silica was mostly located at the pore surface of the carbon. Also, the calculation of the pore volume demonstrated that the silica was transferred into the pores of the carbon without structural collapse during HF etching. When the prepared mesoporous carbon was applied to a supercapacitor electrode, the rectangular shape of the cyclic voltammogram was less collapsed, even at a high scan rate, which is indicative of its high rate capability. This was due to the low resistance of the electrolyte in the pores (3.8 {Omega} cm{sup 2}), which was smaller than that of conventional activated carbon electrodes and even comparable to that of ordered mesoporous carbon electrodes. This improved performance was probably due to the well developed mesoporosity and high pore connectivity of the prepared mesoporous carbon.

36 MATERIALS SCIENCE↗

Efficient Simulation and Abuse Modeling of Mechanical-Electrochemical-Thermal Phenomena in Lithium-Ion Batteries

NREL's Energy Storage team is exploring the effect of mechanical crush of lithium ion cells on their thermal and electrical safety. PHEV cells, fresh as well as ones aged over 8 months under different temperatures, voltage windows, and charging rates, were subjected to destructive physical analysis. Constitutive relationship and failure criteria were developed for the electrodes, separator as well as packaging material. The mechanical models capture well, the various modes of failure across different cell components. Cell level validation is being conducted by Sandia National Laboratories.

25 ENERGY STORAGE↗

Extreme Fast Charging of Lithium-Ion Battery: Understanding Bottlenecks and Safety Issues

Currently, graphite-based lithium-ion battery (LIB) packs in the electric vehicle (EV) domain can accommodate a charging rate up to 2C, which translates into a 0.5 to 1h recharge time [1-2]. Reducing the recharge time down to 10-15 min range would reduce the gap between the internal combustion engine’s refueling time and EV’s recharge time. Minimizing this gap is seen as attractive to consumers and would eventually enhance the adoption of EVs [1-3]. Significant research activity has been going on globally to understand the scientific limitations associated with high rate charging [4-6]. Extreme fast charging (XFC) of Li-ion batteries can create LIB life and safety issues [1, 7]. Among the issues are shortened battery life and enhanced safety concerns due to potential short creation by Li dendrites [1-2]. The detection and monitoring of Li plating onset and evolution over aging is a significant challenge. In-operando detection schemes to understand the dynamics of Li plating and the role that aging has on Li plating are vital to enable fast charging of specific energy cells. A key to the effort would be understanding the interplay between materials, electrode structure, and use conditions. This presentation will discuss the key bottlenecks of aggressive fast charging (~10 min). In particular, how extreme fast charging impacts individual battery components as well as the overall battery’s performance, life, and safety will be presented in light of experimental results and analysis. The effectiveness and challenges of in-operando electrochemical detection methods in aggressive charging conditions shall also be discussed. References [1] S. Ahmed, I. Bloom, A. N. Jansen, T. R. Tanim, E. J. Dufek, A. Pesaran, A. Burnham, R. B. Carlson, F. Dias, K. Hardy,M. Keyser, C. Kreuzer, A. Markel, A. Meintz, C. Michelbacher, M. Mohanpurkar, P. A. Nelson, D. C. Robertson, D. Scoffield,M. Shirk, T. Stephens, R. Vijayagopal, J. Zhang, Enabling fast charging–A battery technology gap assessment, J Power Sources,367 (2017), 250-262 [2] T.R. Tanim, M. G. Shirk, R. L. Bewley, E. J. Dufek, B. Y. Liaw, Fast charge implications: Pack and cell analysis and comparison,, J Power Sources, 381 (2018) 56-65 [3] N. Lutsey, S. Searle, S. Chambliss, and A. Bandivadekar, Assessment of leading electric vehicle promotion activities inUnited States cities, International Council on Clean Transportation, July 2015 [4] C. Michelbacher, S. Ahmed, I. Bloom, A. Burnham, B. Carlson, F. Dias, E. J. Dufek, A. N Jansen, M. Keyser, A. Markel,A. Meintz, M. Mohanpurkar, A. Pesaran, D. Scoffield, M. Shirk, T. Stephens, T. R. Tanim, R. Vijayagopal, J. Zhang, Enablingfast charging–Introduction and overview, J Power Sources, [5] E-Mobility: New Possibilities with 800-volt charging, Porsche newsroom, https://newsroom.porsche.com/en/technology/porsche-engineering-e-power-electromobility-800-volt-charging-12720.html(accessed Sep 2017) [6] Charging interface initiative e.V. - Industry statement on future charging infrastructure, available at: http://www.charinev.org/fileadmin/Downloads/Papers_and_Regulations/CharIN_industry_statement.pdf(accessed June 2017) [7] T. Waldmann, B. Hogg,M. Kasper, S. Grolleau, C. Couceiro, K. Trad, B. P. Matadi and M. Wohlfahrt-Mehrens, Interplay ofOperational Parameters on Lithium Deposition in Lithium-Ion Cells: Systematic Measurements with Reconstructed 3-ElectrodePouch Full Cells, J. Electrochem. Soc. 163 (7) (2016) A1232-A1238

25 ENERGY STORAGE↗

Radiotherapy With 8-MHz Radiofrequency-Capacitive Regional Hyperthermia for Stage III Non-Small-Cell Lung Cancer: The Radiofrequency-Output Power Correlates With the Intraesophageal Temperature and Clinical Outcomes

Purpose: To assess the efficacy of radiotherapy (RT) combined with regional hyperthermia (HT) guided by radiofrequency (RF)-output power and intraesophageal temperature and evaluate the potential contribution of HT to clinical outcomes in patients with Stage III non-small-cell lung cancer (NSCLC). Methods and Materials: Thirty-five patients with Stage III NSCLC treated with RT plus regional HT were retrospectively analyzed. Twenty-two of the 35 patients underwent intraesophageal temperature measurements. Patients with subcutaneous fat of 2.5 cm or greater, older age, or other serious complications did not undergo this therapy. The 8-MHz RF-capacitive heating device was applied, and in all patients, both the upper and lower electrodes were 30 cm in diameter, placed on opposite sides of the whole thoracic region, and treatment posture was the prone position. The HT was applied within 15 minutes after RT once or twice a week. Results: All thermal parameters, minimum, maximum, and mean of the four intraesophageal temperature measurements at the end of each session and the proportion of the time during which at least one of the four intraesophageal measurements was 41{sup o}C or higher in the total period of each session of HT, of the intraesophageal temperature significantly correlated with median RF-output power. Median RF-output power ({>=}1,200 W) was a statistically significant prognostic factor for overall, local recurrence-free, and distant metastasis-free survival. Conclusions: The RT combined with regional HT using a higher RF-output power could contribute to better clinical outcomes in patients with Stage III NSCLC. The RF-output power thus may be used as a promising parameter to assess the treatment of deep regional HT if deep heating using this device is performed with the same size electrodes and in the same body posture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Explainable Artificial Intelligence to Predict Perovskite Solar Cell Electrical Metastability from Operando Photoluminescence Images in Accelerated Stress Testing

Metal halide perovskite (MHP) solar cells exhibit a metastable response to bias governed by coupled ionic–electronic processes, complicating the conventional reciprocity relation between luminescence intensity and device open-circuit voltage (V oc ). This limits the use of luminescence as a diagnostic for device screening or accelerated stress testing, motivating new approaches that can interpret photoluminescence (PL) signals under nonequilibrium conditions. From the artificial intelligence perspective, we develop an explainable deep learning framework that integrates convolutional neural networks (CNN), long short-term memory (LSTM) layers, and an attention mechanism to learn spatiotemporal features from operando photoluminescence PL image sequences. The model achieves a mean absolute error of ±0.027 V in predicting open-circuit voltage transients and reduces extreme-tail errors by up to 78% compared to physics-based reciprocity calculations. Gradient-weighted Class Activation Mapping (Grad-CAM) provides interpretability by highlighting physically meaningful regions such as electrode edges and emergent defect features. From the engineering application perspective, this framework enables accurate, contactless prediction of device V oc and identification of degradation-relevant features during accelerated aging of perovskite solar cells. This approach demonstrates how explainable AI can enhance operando diagnostics and reliability analysis in photovoltaic devices under nonequilibrium conditions.

14 SOLAR ENERGY↗

Surgical evaluation of candidates for cochlear implants

The customary presentation of surgical procedures to patients in the United States consists of discussions on alternative treatment methods, risks of the procedure(s) under consideration, and potential benefits for the patient. Because the contents of the normal speech signal have not been defined in a way that permits a surgeon systematically to provide alternative auditory signals to a deaf patient, the burden is placed on the surgeon to make an arbitrary selection of candidates and available devices for cochlear prosthetic implantation. In an attempt to obtain some information regarding the ability of a deaf patient to use electrical signals to detect and understand speech, the Good Samaritan Hospital and Neurological Sciences Institute cochlear implant team has routinely performed tympanotomies using local anesthesia and has positioned temporary electrodes onto the round windows of implant candidates. The purpose of this paper is to review our experience with this procedure and to provide some observations that may be useful in a comprehensive preoperative evaluation for totally deaf patients who are being considered for cochlear implantation.

Non-NASA Center↗

Achieving 5,000-h and 8,000-h Low-PGM Electrode Durability on Automotive Drive Cycles

Whereas total Pt loading in anode and cathode catalysts below 0.125 mg cm −2 is required to meet the stringent cost target for automotive fuel cell systems (FCS) for light duty vehicles, low-loaded cathode catalysts are susceptible to unacceptable aging-related performance losses at high current densities. A framework model, validated by accelerated stress test data, has identified cell voltage, relative humidity (RH) and temperature as the key operating variables that affect degradation of a high-activity d-PtCo/C cathode catalyst with 0.1 mg cm −2 Pt loading. Drive cycle simulations indicate that these can be controlled by properly selecting the minimum FCS power, compressor-expander module (CEM) turndown, and stack coolant temperature. The optimum system parameters are 4-kW e minimum power for an 80-kW e FCS, CEM turndown of 12.5, and 66 °C average coolant exit temperature that combine to limit the maximum cell voltage to 850 mV and outlet RH to 90%–100%. Depending on Pt loading, the mismatch between actual and allowable degradation for 10% power loss over 5,000-h lifetime requires the stack to be oversized by 2.4%–5%, resulting in 8.4%–41% lower Pt utilization and 7.1%–20.5% penalty in stack cost. The corresponding results for 8,000-h lifetime are 10.3%-14% stack oversizing, 23%–51.8% lower Pt utilization, and 24.1%–35.4% stack cost penalty.

08 HYDROGEN↗

Investigation of ISIS and Brookhaven National Laboratory ion source electrodes after extended operation

Linac4 accelerator of Centre Europeen de Recherches Nucleaires is under construction and a RF-driven H{sup -} ion source is being developed. The beam current requirement for Linac4 is very challenging: 80 mA must be provided. Cesiated plasma discharge ion sources such as Penning or magnetron sources are also potential candidates. Accelerator ion sources must achieve typical reliability figures of 95% and above. Investigating and understanding the underlying mechanisms involved with source failure or ageing is critical when selecting the ion source technology. Plasma discharge driven surface ion sources rely on molybdenum cathodes. Deformation of the cathode surfaces is visible after extended operation periods. A metallurgical investigation of an ISIS ion source is presented. The origin of the deformation is twofold: Molybdenum sputtering by cesium ions digs few tenths of mm cavities while a growth of molybdenum is observed in the immediate vicinity. The molybdenum growth under hydrogen atmosphere is hard and loosely bound to the bulk. It is, therefore, likely to peel off and be transported within the plasma volume. The observation of the cathode, anode, and extraction electrodes of the magnetron source operated at BNL for two years are presented. A beam simulation of H{sup -}, electrons, and Cs{sup -} ions was performed with the IBSimu code package to qualitatively explain the observations. This paper describes the operation conditions of the ion sources and discusses the metallurgical analysis and beam simulation results.

08 HYDROGEN↗

Interfacial pressure improves calendar aging of lithium metal anodes

Lithium (Li) metal is a promising anode because its theoretical specific capacity is approximately ten times larger than graphite. However, Li anodes suffer from long-term capacity fade due to Li stranding (becoming electronically disconnected) and electrolyte decomposition. Applied interfacial pressure has been shown to improve Li anode cycling, likely due to reincorporating stranded or “dead” Li into the anode. Calendar aging can also lead to Li capacity loss due to electrolyte decomposition/Li corrosion and the formation of stranded Li. Some research suggests that calendar aging during cycling results in reversible capacity losses due to Li stranding and reconnection. We here investigate the effect of applied interfacial pressure on Li anode calendar aging during cycling with incorporated rest steps in a localized high-concentration electrolyte (LHCE) to understand if pressure can mitigate stranded Li formation during rest by manipulating the Li morphology. Pouch cells exhibit more stable cycling and denser Li deposits between 10 kPa and 1,000 kPa of applied pressure compared to no applied pressure. Despite drops in CE during periodic rest cycles, the average cumulative lost capacity and average coulombic efficiency (CE) of cells over 50 cycles show that cells aged with incorporated rest steps perform similarly to cells cycled without added rests. This similar average CE suggests that dead Li is largely responsible for drops in CE during rest rather than irreversible Li corrosion and that the dead Li can be reconnected in subsequent cycling. The addition of a lithiophilic ZnO coating to the Cu working electrode increases the adhesion and coverage of Li deposits at low pressures and improves CE during the first cycle.

25 ENERGY STORAGE↗

Using Biosurfactants Produced from Agriculture Process Waste Streams to Improve Oil Recovery in Fractured Carbonate Reservoirs

This report describes the progress of our research during the first 30 months (10/01/2004 to 03/31/2007) of the original three-year project cycle. The project was terminated early due to DOE budget cuts. This was a joint project between the Tertiary Oil Recovery Project (TORP) at the University of Kansas and the Idaho National Laboratory (INL). The objective was to evaluate the use of low-cost biosurfactants produced from agriculture process waste streams to improve oil recovery in fractured carbonate reservoirs through wettability mediation. Biosurfactant for this project was produced using Bacillus subtilis 21332 and purified potato starch as the growth medium. The INL team produced the biosurfactant and characterized it as surfactin. INL supplied surfactin as required for the tests at KU as well as providing other microbiological services. Interfacial tension (IFT) between Soltrol 130 and both potential benchmark chemical surfactants and crude surfactin was measured over a range of concentrations. The performance of the crude surfactin preparation in reducing IFT was greater than any of the synthetic compounds throughout the concentration range studied but at low concentrations, sodium laureth sulfate (SLS) was closest to the surfactin, and was used as the benchmark in subsequent studies. Core characterization was carried out using both traditional flooding techniques to find porosity and permeability; and NMR/MRI to image cores and identify pore architecture and degree of heterogeneity. A cleaning regime was identified and developed to remove organic materials from cores and crushed carbonate rock. This allowed cores to be fully characterized and returned to a reproducible wettability state when coupled with a crude-oil aging regime. Rapid wettability assessments for crushed matrix material were developed, and used to inform slower Amott wettability tests. Initial static absorption experiments exposed limitations in the use of HPLC and TOC to determine surfactant concentrations. To reliably quantify both benchmark surfactants and surfactin, a surfactant ion-selective electrode was used as an indicator in the potentiometric titration of the anionic surfactants with Hyamine 1622. The wettability change mediated by dilute solutions of a commercial preparation of SLS (STEOL CS-330) and surfactin was assessed using two-phase separation, and water flotation techniques; and surfactant loss due to retention and adsorption on the rock was determined. Qualitative tests indicated that on a molar basis, surfactin is more effective than STEOL CS-330 in altering wettability of crushed Lansing-Kansas City carbonates from oil-wet to water-wet state. Adsorption isotherms of STEOL CS-330 and surfactin on crushed Lansing-Kansas City outcrop and reservoir material showed that surfactin has higher specific adsorption on these oomoldic carbonates. Amott wettability studies confirmed that cleaned cores are mixed-wet, and that the aging procedure renders them oil-wet. Tests of aged cores with no initial water saturation resulted in very little spontaneous oil production, suggesting that water-wet pathways into the matrix are required for wettability change to occur. Further investigation of spontaneous imbibition and forced imbibition of water and surfactant solutions into LKC cores under a variety of conditions--cleaned vs. crude oil-aged; oil saturated vs. initial water saturation; flooded with surfactant vs. not flooded--indicated that in water-wet or intermediate wet cores, sodium laureth sulfate is more effective at enhancing spontaneous imbibition through wettability change. However, in more oil-wet systems, surfactin at the same concentration performs significantly better.

02 PETROLEUM↗

Variability in Hoffmann and tendon reflexes in healthy male subjects

There is a time dependent decrease in amplitude of H- and T-reflexes during Zero-G exposure and subsequently an increase in the amplitude of the H-reflex 2-4 hours after return to a 1-G environment. These alterations have been attributed to the adaptation of the human neurosensory system to gravity. The Hoffman reflex (H-reflex) is an acknowledged method to determine the integrity of the monosynaptic reflex arc. However deep tendon reflexes (DTR's or T-reflexes), elicited by striking the tendon also utilize the entire reflex arc. The objective of this study was to compare the variability in latency and amplitude of the two reflexes in healthy subjects. Methods: Nine healthy male subjects, 27-43 years in age, 161-175 cm in height plus 60-86 Kg in weight, underwent weekly testing for four weeks with a Dan-Tec EMG counterpoint EMG system. Subjects were studied prone and surface EMG electrodes were placed on the right and left soleus muscles. The H-reflex was obtained by stimulating the tibial nerve in the politeal fossa with a 0.2 msec square wave pulse delivered at 2 Hz until the maximum H-reflex was obtained. The T-reflex was invoked by tapping the achilles tendon with a self triggering reflex hammer connected to the EMG system. The latencies and amplitudes for the H- and T-reflexes were measured. Results: These data indicate that the amplitudes of these reflexes varied considerably. However, latencies to invoked responses were consistent. The latency of the T-reflex was approximately 3-5 msec longer than the H-reflex. Conclusion: The T-reflex is easily obtained, requires less time, and is more comfortable to perform. Qualitative data can be obtained by deploying self triggering, force plated reflex hammers both in the 1-G and Zero-G environment.

Good, E.↗