Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Automated, Miniaturized Instrument for Measuring Gene Expression in Space

To facilitate astrobiological studies on the survival and adaptation of microorganisms and mixed microbial cultures to space environment, we have been developing a fully automated, miniaturized system for measuring their gene expression on small spacecraft. This low-cost, multi-purpose instrument represents a major scientific and technological advancement in our ability to study the impact of the space environment on biological systems by providing data on cellular metabolism and regulation orders of magnitude richer than what is currently available. The system supports growth of the organism, lyse it to release the expressed RNA, label the RNA, read the expression levels of a large number of genes by microarray analysis of labeled RNA and transmit the measurements to Earth. To measure gene expression we use microarray technology developed by CombiMatrix, which is based on electrochemical reactions on arrays of electrodes on a semiconductor substrate. Since the electrical integrity of the microarray remains intact after probe synthesis, the circuitry can be employed to sense nucleic acid binding at each electrode. CombiMatrix arrays can be sectored to allow multiple samples per chip. In addition, a single array can be used for several assays. The array has been integrated into an automated microfluidic cartridge that uses flexible reagent blisters and pinch pumping to move liquid reagents between chambers. The proposed instrument will help to understand adaptation of terrestrial life to conditions beyond the planet of origin, identify deleterious effects of the space environment, develop effective countermeasures against these effects, and test our ability to sustain and grow in space organisms that can be used for life support and in situ resource utilization during long-duration space exploration. The instrument is suitable for small satellite platforms, which provide frequent, low cost access to space. It can be also used on any other platform in space, including the ISS. It can be replicated and used with only small modifications in multiple biological experiments with a broad range of goals in mind.

Pohorille, A.↗

High-power ultraviolet (UV) and vacuum ultraviolet (VUV) lamps with micro-cavity plasma arrays

A plasma lamp includes plates that are approximately parallel, with at least one array of microcavities formed in a surface of at least one plate. When desirable, the plates are separated a fixed distance by spacers with at least one spacer being placed near the plate's edge to form a hermetic seal therewith. A gas makes contact with the microcavity array. Electrodes capable of delivering a time-varying voltage are located on the surface of each plate. At least one electrode is located on an exterior surface of at least one interior plate. Optionally, protective windows may be placed over the electrodes. The application of the time-varying voltage interacts with the gas to form a glow discharge plasma in the microcavities and the fixed volume between the plates (when present). The glow discharge plasma efficiently and uniformly emits UV/VUV radiation over the entire surface of the lamp.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-power ultraviolet (UV) and vacuum ultraviolet (VUV) lamps with micro-cavity plasma arrays

A product having at least one plasma lamp that includes plates that are approximately parallel, with at least one array of microcavities formed in a surface of at least one plate. When desirable, the plates are separated a fixed distance by spacers with at least one spacer being placed near the plate's edge to form a hermetic seal therewith. A gas makes contact with the microcavity array. Electrodes capable of delivering a time-varying voltage are located such that the application of the time-varying voltage interacts with the gas to form a glow discharge plasma in the microcavities and the fixed volume between the plates. The glow discharge plasma efficiently and uniformly emits radiation that is predominantly in the UV/VUV spectral range with at least a portion of the radiation being emitted from the plasma lamp.

Park, Sung-Jin↗

Near Real-Time Two and Three-Dimensional Electrical Geophysical Monitoring of Natural and Engineered Processes Associated with Subsurface Remediation - 16052

Legacy soil and groundwater contamination associated with nuclear weapons production is projected to be one of the largest cleanup liabilities to the U.S. Department of Energy for the foreseeable future. Remediation of subsurface contaminants is complicated by the combined effects of geochemical heterogeneity, geological heterogeneity, and the difficulty and expense of adequate borehole access. Each of these complications contributes to uncertainty in the distribution of contaminants and the performance of in situ treatments, which increases risk to human health and the environment and cost to closure in general. Electrical resistivity tomography (ERT) is a method of remotely imaging the electrical properties of the subsurface, which are governed by both geochemical and geological structure, thereby providing useful proxies for understanding contaminant distribution and the behavior in situ remediation processes. Recent advancements in both data collection and data processing capabilities are enabling ERT monitoring to be executed and provided to site operators in near real-time. To summarize the process, ERT surveys are rapidly and continuously collected during a time-sensitive operation such as an amendment injection. At the completion of each survey, data are transferred by wireless internet to offsite supercomputing resources for parallel tomographic inversion. Inversion results are then transferred back to onsite operators and/or other locations for visualization. In this paper, we demonstrate the utility of time-lapse ERT for monitoring fluid transport (both gas and liquid phase). We then demonstrate two real-time imaging applications for monitoring both natural and engineered processes at the Hanford Site within the vadose and the saturated zones. We expect this new capability for autonomous real-time imaging to enable ERT to be used as a cost-effective, short-term rapid feedback mechanism for guiding subsurface remediation injections, in addition to longer term monitoring of post-injection performance and environmental impact, all using the same electrode array and instrumentation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implantable neuromodulation system for closed-loop stimulation and recording simultaneously at multiple brain sets

The present disclosure relates to a modular system for deep brain stimulation (DBS) and electrocorticography (ECoG). The system may have an implantable neuromodulator for generating electrical stimulation signals adapted to be applied to a desired region of a brain via an attached electrode array. An aggregator module may be used for collecting and aggregating electrical signals and transmitting the electrical signals to the neuromodulator. A control module may be used which is in communication with the aggregator module for controlling generation of the electrical signals and transmitting the electrical signals to the aggregator.

Pannu, Satinderpall S.↗

Fabrication and electrical properties of single wall carbon nanotube channel and graphene electrode based transistors arrays

A transistor structure composed of an individual single-walled carbon nanotube (SWNT) channel with a graphene electrode was demonstrated. The integrated arrays of transistor devices were prepared by transferring patterned graphene electrode patterns on top of the aligned SWNT along one direction. Both single and multi layer graphene were used for the electrode materials; typical p-type transistor and Schottky diode behavior were observed, respectively. Based on our fabrication method and device performances, several issues are suggested and discussed to improve the device reliability and finally to realize all carbon based future electronic systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Biochips Containing Arrays of Carbon-Nanotube Electrodes

Biochips containing arrays of nanoelectrodes based on multiwalled carbon nanotubes (MWCNTs) are being developed as means of ultrasensitive electrochemical detection of specific deoxyribonucleic acid (DNA) and messenger ribonucleic acid (mRNA) biomarkers for purposes of medical diagnosis and bioenvironmental monitoring. In mass production, these biochips could be relatively inexpensive (hence, disposable). These biochips would be integrated with computer-controlled microfluidic and microelectronic devices in automated hand-held and bench-top instruments that could be used to perform rapid in vitro genetic analyses with simplified preparation of samples. Carbon nanotubes are attractive for use as nanoelectrodes for detection of biomolecules because of their nanoscale dimensions and their chemical properties.

Li, Jun↗

Self-supported Zn/Si core-shell arrays as advanced electrodes for lithium ion batteries

Graphical abstract: Zn/Si core-shell arrays prepared by combined hydrothermal plus sputtering method show good performance with high specific capacity and excellent cycling stability. - Highlights: • Construct Zn/Si core-shell arrays via sputtering. • The Zn/Si core-shell arrays show high capacity and good cycles. • Core-shell arrays is favorable for fast ion/electron transfer. - Abstract: Silicon is considered as the most promising substitute for the commercial graphite anode of lithium ion batteries (LIBs) due to its high capacity and low working voltage. In this work, we realize the rational combination between Zn nanorods and Si forming self-supported Zn/Si core-shell arrays with the aid of hydrothermal and sputtering methods. Amorphous Si layer is well coated on the backbone of Zn nanorods with diameters of 70–80 nm. As a preliminary test, the Zn/Si core-shell arrays are used as the anode of LIBs and demonstrated with a high initial reversible capacity of 2795 mAh g{sup −1} at 0.1C, good high-rate capability with 1985 mAh g{sup −1} at 1C and stable cycling life. The good performance is due to the highly conductive Zn nanorod network and porous core-shell structure providing good mechanical support and fast transport of ions/electrons.

36 MATERIALS SCIENCE↗

Method and device for ion mobility separation

Methods and devices for ion separations or manipulations in gas phase are disclosed. The device includes a non-planar surface having a first, second and third region. An inner arrays of electrodes is positioned on the first region. A first set of electrodes of the inner array of electrodes is configured to receive RF voltages and generate a first potential upon the receipt of the RF voltage. A first and second outer arrays of electrodes are coupled to the second and third region, respectively. The first and second outer arrays are configured to receive a first DC voltage and generate a second potential upon the receipt of the first DC voltages. The first and second generated potential manipulate movement of ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fabrication of Nickel Oxide Nanopillar Arrays on Flexible Electrodes for Highly Efficient Perovskite Solar Cells

Semiconductor nanomaterials with controlled morphologies and architectures are of critical importance for high-performance optoelectronic devices. However, the fabrication of such nanomaterials on polymer-based flexible electrodes is particularly challenging due to degradation of the flexible electrodes at a high temperature. In this paper, we report the fabrication of nickel oxide nanopillar arrays (NiO x NaPAs) on a flexible electrode by vapor deposition, which enables highly efficient perovskite solar cells (PSCs). The NiO x NaPAs exhibit an enhanced light transmittance for light harvesting, prohibit exciton recombination, promote irradiation-generated hole transport and collection, and facilitate the formation of large perovskite grains. These advantageous features result in a high efficiency of 20% and 17% for the rigid and flexible PSCs, respectively. Additionally, the NaPAs show no cracking after 500 times of bending, consistent with the mechanic simulation results. Lastly, this robust fabrication opens a new opportunity for the fabrication of a large area of high-performance flexible optoelectronic devices.

14 SOLAR ENERGY↗

Liquid crystalline phase synthesis of nanoporous MnO{sub 2} thin film arrays as an electrode material for electrochemical capacitors

Graphical abstract: Three-dimensional (3D) MnO{sub 2} thin film arrays with nanoporous structure is electrodeposited on Ti foil from hexagonal lyotropic liquid crystalline phase. Low-angle X-ray diffraction (XRD), wide-angle XRD, field emission scanning electron microscopy (FESEM), and transmission electron microscopy (TEM) are employed to study the morphology and the structure of the as-synthesized MnO{sub 2} materials. Galvanostatic charge/discharge measurements show the nanoporous, 3D electrode material exhibits excellent capacitive performance between the potential range of −0.1 to 0.9 V, and a maximum specific capacitance as high as 462 F g{sup −1} are achieved in 0.5 M Na{sub 2}SO{sub 4} solution at a charge/discharge current density of 4 A g{sup −1}. Highlights: ► 3D MnO{sub 2} thin film arrays with nanoporous structure is fabricated for the first time. ► A maximum specific capacitance as high as 462 F g{sup −1} is obtained. ► The 3D and nanoporous superarchitecture facilitate electrolyte penetration. -- Abstract: Three-dimensional (3D) MnO{sub 2} thin film arrays with nanoporous structure is electrodeposited on Ti foil from hexagonal lyotropic liquid crystalline phase. Low-angle X-ray diffraction (XRD), wide-angle XRD, field emission scanning electron microscopy (FESEM), and transmission electron microscopy (TEM) are employed to study the morphology and the structure of the as-synthesized MnO{sub 2} materials. Galvanostatic charge/discharge measurements show the nanoporous, 3D electrode material exhibits excellent capacitive performance between the potential range of −0.1 to 0.9 V, and a maximum specific capacitance as high as 462 F g{sup −1} are achieved in 0.5 M Na{sub 2}SO{sub 4} solution at a charge/discharge current density of 4 A g{sup −1}.

36 MATERIALS SCIENCE↗

Frequency modulated radio frequency electric field for ion manipulation

A method of manipulating ions comprises injecting ions between a first surface and a second surface positioned parallel to and spaced apart from each other and defining a central axis therebetween, wherein the first surface comprises first outer electrodes coupled to the first surface and a first inner array of electrodes coupled to the first surface and positioned between the first outer electrodes, wherein the second surface comprises second outer electrodes coupled to the second surface and a second inner array of electrodes coupled to the second surface and positioned between the second outer electrodes, and applying a frequency modulated RF voltage to at least one electrode of the first inner array of electrodes or the second inner array of electrodes to confine ions between the first surface and the second surface and to guide ions between the first surface and the second surface along the central axis.

42 ENGINEERING↗

Electrodeposition of gold nanoparticle arrays on ITO glass as electrode with high electrocatalytic activity

Highlights: ► Electrodeposition of gold nanoparticle arrays on ITO glass as catalytic-electrodes. ► The sizes and densities of the gold nanoparticles can be easily controlled. ► Such arrays on ITO glass shows high electrocatalytic activity and good stability. - Abstract: Herein, we reported a templateless, surfactantless, and simple electrochemical method to directly fabricate gold nanoparticle (AuNP) arrays on indium tin oxide (ITO) glass substrates as effective electrocatalytic electrodes. The as-prepared AuNP arrays have been characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), etc. AuNPs with small sizes (<20 nm) were uniformly deposited on the ITO glass under constant current densities, and particle densities can be adjusted by varying the applied charges. The resultant AuNP array electrode showed higher catalytic activity and good stability toward electro-oxidation of ascorbic acid compared with other electrodes, such as bare ITO electrode, bare glassy carbon electrode and bulk gold film electrode.

36 MATERIALS SCIENCE↗

Improving in vitro to in vivo extrapolation by incorporating toxicokinetic measurements: A case study of lindane-induced neurotoxicity

Approaches for extrapolating in vitro toxicity testing results for prediction of human in vivo outcomes are needed. The purpose of this case study was to employ in vitro toxicokinetics and PBPK modeling to perform in vitro to in vivo extrapolation (IVIVE) of lindane neurotoxicity. Lindane cell and media concentrations in vitro, together with in vitro concentration-response data for lindane effects on neuronal network firing rates, were compared to in vivo data and model simulations as an exercise in extrapolation for chemical-induced neurotoxicity in rodents and humans. Time- and concentration-dependent lindane dosimetry was determined in primary cultures of rat cortical neurons in vitro using “faux” (without electrodes) microelectrode arrays (MEAs). In vivo data were derived from literature values, and physiologically based pharmacokinetic (PBPK) modeling was used to extrapolate from rat to human. The previously determined EC{sub 50} for increased firing rates in primary cultures of cortical neurons was 0.6 μg/ml. Media and cell lindane concentrations at the EC{sub 50} were 0.4 μg/ml and 7.1 μg/ml, respectively, and cellular lindane accumulation was time- and concentration-dependent. Rat blood and brain lindane levels during seizures were 1.7–1.9 μg/ml and 5–11 μg/ml, respectively. Brain lindane levels associated with seizures in rats and those predicted for humans (average = 7 μg/ml) by PBPK modeling were very similar to in vitro concentrations detected in cortical cells at the EC{sub 50} dose. PBPK model predictions matched literature data and timing. These findings indicate that in vitro MEA results are predictive of in vivo responses to lindane and demonstrate a successful modeling approach for IVIVE of rat and human neurotoxicity. - Highlights: • In vitro to in vivo extrapolation for lindane neurotoxicity was performed. • Dosimetry of lindane in a micro-electrode array (MEA) test system was assessed. • Cell concentrations at the MEA EC{sub 50} equaled rat brain levels associated with seizure. • PBPK-predicted human brain levels at seizure also equaled EC{sub 50} cell concentrations. • In vitro MEA results are predictive of lindane in vivo dose–response in rats/humans.

60 APPLIED LIFE SCIENCES↗

Electrical Capacitance Volume Tomography with High-Contrast Dielectrics

The Electrical Capacitance Volume Tomography (ECVT) system has been designed to complement the tools created to sense the presence of water in nonconductive spacecraft materials, by helping to not only find the approximate location of moisture but also its quantity and depth. The ECVT system has been created for use with a new image reconstruction algorithm capable of imaging high-contrast dielectric distributions. Rather than relying solely on mutual capacitance readings as is done in traditional electrical capacitance tomography applications, this method reconstructs high-resolution images using only the self-capacitance measurements. The image reconstruction method assumes that the material under inspection consists of a binary dielectric distribution, with either a high relative dielectric value representing the water or a low dielectric value for the background material. By constraining the unknown dielectric material to one of two values, the inverse math problem that must be solved to generate the image is no longer ill-determined. The image resolution becomes limited only by the accuracy and resolution of the measurement circuitry. Images were reconstructed using this method with both synthetic and real data acquired using an aluminum structure inserted at different positions within the sensing region. The cuboid geometry of the system has two parallel planes of 16 conductors arranged in a 4 4 pattern. The electrode geometry consists of parallel planes of copper conductors, connected through custom-built switch electronics, to a commercially available capacitance to digital converter. The figure shows two 4 4 arrays of electrodes milled from square sections of copper-clad circuit-board material and mounted on two pieces of glass-filled plastic backing, which were cut to approximately square shapes, 10 cm on a side. Each electrode is placed on 2.0-cm centers. The parallel arrays were mounted with the electrode arrays approximately 3 cm apart. The open ends were surrounded by a metal guard to reduce the sensitivity of the electrodes to outside interference and to help maintain the spacing between the arrays. Other uses for this innovation potentially include quantifying the amount of commodity remaining in the fuel and oxidizer tanks while on-orbit without having to fire spacecraft engines. Another orbit application is moisture sensing in plant-growth experiments because microgravity causes moisture in soil to distribute itself in unusual ways. At the moment, the hardware and image reconstruction technique may only be of interest to people involved in nondestructive evaluation. The reconstructed image takes almost a full week to reproduce with existing computer power. However, because computer power and speeds follows Moore s Law, execution times are likely to become acceptable within the next five to eight years. The code was written in Mathematica for dedicated use with the ECVT system. In its present form, it is not suitable to be used directly as a consumer product. However, the code could be likely improved by rewriting it in a compiled language such as C or Fortran.

Nurge, Mark↗

Electrochemical Detection of Multiple Bioprocess Analytes

An apparatus that includes highly miniaturized thin-film electrochemical sensor array has been demonstrated as a prototype of instruments for simultaneous detection of multiple substances of interest (analytes) and measurement of acidity or alkalinity in bioprocess streams. Measurements of pH and of concentrations of nutrients and wastes in cell-culture media, made by use of these instruments, are to be used as feedback for optimizing the growth of cells or the production of desired substances by the cultured cells. The apparatus is designed to utilize samples of minimal volume so as to minimize any perturbation of monitored processes. The apparatus can function in a potentiometric mode (for measuring pH), an amperometric mode (detecting analytes via oxidation/reduction reactions), or both. The sensor array is planar and includes multiple thin-film microelectrodes covered with hydrous iridium oxide. The oxide layer on each electrode serves as both a protective and electrochemical transducing layer. In its transducing role, the oxide provides electrical conductivity for amperometric measurement or pH response for potentiometric measurement. The oxide on an electrode can also serve as a matrix for one or more enzymes that render the electrode sensitive to a specific analyte. In addition to transducing electrodes, the array includes electrodes for potential control. The array can be fabricated by techniques familiar to the microelectronics industry. The sensor array is housed in a thin-film liquid-flow cell that has a total volume of about 100 mL. The flow cell is connected to a computer-controlled subsystem that periodically draws samples from the bioprocess stream to be monitored. Before entering the cell, each 100-mL sample is subjected to tangential-flow filtration to remove particles. In the present version of the apparatus, the electrodes are operated under control by a potentiostat and are used to simultaneously measure the pH and the concentration of glucose. It is anticipated that development of procedures for trapping more enzymes into hydrous iridium oxide (and possibly into other electroactive metal oxides) and of means for imparting long-term stability to the transducer layers should make it possible to monitor concentrations of products of many enzyme reactions for example, such key bioprocess analytes as amino acids, vitamins, lactose, and acetate.

Rauh, R. David↗

Graphene Transparent Conductive Electrodes for Next- Generation Microshutter Arrays

Graphene is a single atomic layer of graphite. It is optically transparent and has high electron mobility, and thus has great potential to make transparent conductive electrodes. This invention contributes towards the development of graphene transparent conductive electrodes for next-generation microshutter arrays. The original design for the electrodes of the next generation of microshutters uses indium-tin-oxide (ITO) as the electrode material. ITO is widely used in NASA flight missions. The optical transparency of ITO is limited, and the material is brittle. Also, ITO has been getting more expensive in recent years. The objective of the invention is to develop a graphene transparent conductive electrode that will replace ITO. An exfoliation procedure was developed to make graphene out of graphite crystals. In addition, large areas of single-layer graphene were produced using low-pressure chemical vapor deposition (LPCVD) with high optical transparency. A special graphene transport procedure was developed for transferring graphene from copper substrates to arbitrary substrates. The concept is to grow large-size graphene sheets using the LPCVD system through chemical reaction, transfer the graphene film to a substrate, dope graphene to reduce the sheet resistance, and pattern the film to the dimension of the electrodes in the microshutter array. Graphene transparent conductive electrodes are expected to have a transparency of 97.7%. This covers the electromagnetic spectrum from UV to IR. In comparison, ITO electrodes currently used in microshutter arrays have 85% transparency in mid-IR, and suffer from dramatic transparency drop at a wavelength of near-IR or shorter. Thus, graphene also has potential application as transparent conductive electrodes for Schottky photodiodes in the UV region.

Li, Mary↗