Search NASA⌕ Search

SEARCH · Search NASA

Results for “electromagnetic responses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Proton electromagnetic generalized polarizabilities

Electromagnetic polarizabilities are fundamental properties of the proton that characterize its response to an external electromagnetic (EM) field. The generalization of the EM polarizabilities to non-zero four-momentum transfer opens up a powerful path to study the internal structure of the proton. They map out the spatial distribution of the polarization densities in the proton, provide access to key dynamical mechanisms that contribute to the electric and magnetic polarizability effects, and allow for the determination of fundamental characteristics of the system, such as the electric and magnetic polarizability radii. This article reviews our knowledge about proton EM generalized polarizabilities (GPs). An introduction is given to the basic concepts and the theoretical framework, which is then followed by a discussion that emphasizes the recent developments and findings of the virtual Compton scattering (VCS) experiments and future perspectives on the topic.

hadrons↗

Topology and geometry under the nonlinear electromagnetic spotlight

For many materials, a precise knowledge of their dispersion spectra is insufficient to predict their ordered phases and physical responses. Instead, these materials are classified by the geometrical and topological properties of their wavefunctions. A key challenge is to identify and implement experiments that probe or control these quantum properties. In this Review, we describe recent progress in this direction, focusing on nonlinear electromagnetic responses that arise directly from quantum geometry and topology. Furthermore, we give an overview of the field by discussing theoretical ideas, experiments and the materials that drive them. We conclude by discussing how these techniques can be combined with device architectures to uncover, probe and ultimately control quantum phases with emergent topological and correlated properties.

36 MATERIALS SCIENCE↗

Active and tunable nanophotonic metamaterials

Abstract Metamaterials enable subwavelength tailoring of light–matter interactions, driving fundamental discoveries which fuel novel applications in areas ranging from compressed sensing to quantum engineering. Importantly, the metallic and dielectric resonators from which static metamaterials are comprised present an open architecture amenable to materials integration. Thus, incorporating responsive materials such as semiconductors, liquid crystals, phase-change materials, or quantum materials (e.g., superconductors, 2D materials, etc.) imbue metamaterials with dynamic properties, facilitating the development of active and tunable devices harboring enhanced or even entirely novel electromagnetic functionality. Ultimately, active control derives from the ability to craft the local electromagnetic fields; accomplished using a host of external stimuli to modify the electronic or optical properties of the responsive materials embedded into the active regions of the subwavelength resonators. We provide a broad overview of this frontier area of metamaterials research, introducing fundamental concepts and presenting control strategies that include electronic, optical, mechanical, thermal, and magnetic stimuli. The examples presented range from microwave to visible wavelengths, utilizing a wide range of materials to realize spatial light modulators, effective nonlinear media, on-demand optics, and polarimetric imaging as but a few examples. Often, active and tunable nanophotonic metamaterials yield an emergent electromagnetic response that is more than the sum of the parts, providing reconfigurable or real-time control of the amplitude, phase, wavevector, polarization, and frequency of light. The examples to date are impressive, setting the stage for future advances that are likely to impact holography, beyond 5G communications, imaging, and quantum sensing and transduction.

36 MATERIALS SCIENCE↗

Theoretical investigation of braking of tearing mode rotation by resistive walls in ITER

The locking of the 2/1 tearing mode to the resistive wall in the ITER tokamak (15 MA inductive scenario 2) is investigated theoretically using a cylindrical asymptotic matching model. The model takes into account the fact that ITER plasmas will effectively be surrounded by two walls; the inner blanket module layer with a time constant of about 23 ms, and the outer vacuum vessel with a time constant of about 380 ms. The model also takes cognizance of the fact that neither the blanket module layer nor the vacuum vessel can be accurately described as “thin” walls (in the ordinarily accepted sense). The model incorporates changes in both the plasma poloidal and the toroidal angular velocity profiles, in response to the electromagnetic braking torque that develops at the rational surface, because it turns out that neoclassical poloidal flow-damping is not strong enough to completely suppress changes in the poloidal velocity. Finally, the model accurately calculates changes in the poloidal and toroidal plasma angular velocity profiles by evolving the full angular equations of motion, taking the electromagnetic braking torque, plasma inertia, plasma viscosity, and poloidal flow-damping into account. The time required for the 2/1 tearing mode to grow from a small amplitude to a sufficient one to lock to the walls is found to be about 3.5 s. As a result, the critical full radial island width at which wall locking is triggered is found to be about 9% of the plasma minor radius.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The scintillator surface detector of the Pierre Auger observatory

Data collected so far by the Pierre Auger Observatory have enabled major advances in ultra-high energy cosmic ray physics and demonstrated that improved determination of masses of primary cosmic-ray particles, preferably on an event-by-event basis, is necessary for understanding their origin and nature. Improvement in primary mass measurements was the main motivation for the upgrade of the Pierre Auger Observatory, called AugerPrime. As part of this upgrade, scintillator detectors are added to the existing water-Cherenkov surface detector stations. By making use of the differences in detector response to the electromagnetic particles and muons between scintillator and water-Cherenkov detectors, the electromagnetic and muonic components of cosmic-ray air showers can be disentangled. Since the muonic component is sensitive to the primary mass, such combination of detectors provides a powerful way to improve primary mass composition measurements over the original Auger surface detector design. In this paper, the so-called Scintillator Surface Detectors are discussed, including their design characteristics, production process, testing procedure and deployment in the field.

Detector design and construction technologies and ↗

Exploration of Electronic and Magnetic Properties of Ceria for Applications of Microwave Assisted Catalysis

This was presented at APS Global Physics Summit 2025 in Anaheim, CA. This study focuses on characterizing how vacancies and other dopants influence the electronic and magnetic properties of ceria and exploring the potential mechanisms by which these properties affect or control its catalytic behavior under microwave radiation. By examining ceria’s electronic response to external electromagnetic fields, specifically magnetic fields within the microwave range, the work aims to uncover insights into how microwaves might optimize catalytic effects. The study also includes a comparative analysis of different functionals to refine understanding of ceria’s electronic behavior and catalytic efficacy in these applications.

ammonia synthesis↗

The NOvA Test Beam Program

NOvA is a long-baseline off-axis beam neutrino experiment at Fermilab and Ash River, Minnesota. By measuring νμ \nu_\mu disappearance and νe \nu_e appearance at the 14 kiloton NOvA Far Detector, the experiment is addressing outstanding questions in neutrino physics, including the neutrino mass hierarchy and existence of leptonic CP violation. The NOvA Test Beam program, under deployment at the Fermilab Test Beam Facility, will use a scaled-down NOvA detector to sample beams of tagged electrons, muons, pions, and protons in the momentum range of 0.3 to 2 GeV/c. It will further the NOvA physics reach by precisely measuring the detector's muon energy scale and electromagnetic and hadronic response, and provide real data for detailed studies of particle identification techniques. Ongoing efforts on beamline instrumentation, data acquisition, simulation, momentum reconstruction and particle identification are presented. Implications for the neutrino oscillation measurements are discussed.

Huang, Junting [Texas U.]↗

Structural response of a rotating bladed disk to rotor whirl

A set of high speed rotating whirl experiments were performed in the vacuum of the MIT Blowdown Compressor Facility on the MIT Aeroelastic Rotor, which is structurally typical of a modern high bypass ratio turbofan stage. These tests identified the natural frequencies of whirl of the rotor system by forcing its response using an electromagnetic shaker whirl excitation system. The excitation was slowly swept in frequency at constant amplitude for several constant rotor speeds in both a forward and backward whirl direction. The natural frequencies of whirl determined by these experiments were compared to those predicted by an analytical 6 DOF model of a flexible blade-rigid disk-flexible shaft rotor. The model is also presented in terms of nondimensional parameters in order to assess the importance of the interation between the bladed disk dynamics and the shaft-disk dynamics. The correlation between the experimental and predicted natural frequencies is reasonable, given the uncertainty involved in determining the stiffness parameters of the system.

Crawley, E. F.↗

Polarization-Rotating Sensors Connected To Optical Fibers

Proposed optoelectronic sensor system includes polarization-rotating sensing elements interrogated by polarized light transmitted to and from sensing elements along optical fibers. Polarization of light altered by combinations of inherent birefringence, stress-induced birefrigence, and Faraday rotation. Advantages include: light weight, fast response, immunity to electromagnetic interference at radio and lower frequencies, and no need to supply electrical power to sensing elements.

Frazer, Robert E.↗

Time-Domain Computation Of Electromagnetic Fields In MMICs

Maxwell's equations solved on three-dimensional, conformed orthogonal grids by finite-difference techniques. Method of computing frequency-dependent electrical parameters of monolithic microwave integrated circuit (MMIC) involves time-domain computation of propagation of electromagnetic field in response to excitation by single pulse at input terminal, followed by computation of Fourier transforms to obtain frequency-domain response from time-domain response. Parameters computed include electric and magnetic fields, voltages, currents, impedances, scattering parameters, and effective dielectric constants. Powerful and efficient means for analyzing performance of even complicated MMIC.

Lansing, Faiza S.↗

Bone Analyzer

The danger of disuse osteoporosis under weightless condition in space led to extensive research into measurements of bone stiffness and mass by the Biomedical Research Division of Ames and Stanford University. Through its Technology Utilization Program, NASA funded an advanced SOBSA, a microprocessor-controlled bone probe system. SOBSA determines bone stiffness by measuring responses to an electromagnetic shaker. With this information, a physician can identify bone disease, measure deterioration and prescribe necessary therapy. The system is now undergoing further testing.

Source record↗

Improved magnetic suspension technique

Technique combines electromagnetic coil with polarized permanent magnets. This reduces power consumption of electromagnetic units and improves response of magnetic suspension systems, by increasing their sensitivity to changes in current controlling electromagnet.

Studer, P. A.↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of two-phase droplets to intense electromagnetic radiation

The behavior of two-phase droplets subjected to high intensity radiation pulses is studied. Droplets are highly absorbing solids in weakly absorbing liquid medium. The objective of the study was to define heating thresholds required for causing explosive boiling and secondary atomization of the fuel droplet. The results point to mechanisms for energy storage and transport in two-phase systems.

TWO PHASE DROPLETS↗

Systems, Apparatuses and Methods for Beamforming RFID Tags

A radio frequency identification (RFID) system includes an RFID interrogator and an RFID tag having a plurality of information sources and a beamforming network. The tag receives electromagnetic radiation from the interrogator. The beamforming network directs the received electromagnetic radiation to a subset of the plurality of information sources. The RFID tag transmits a response to the received electromagnetic radiation, based on the subset of the plurality of information sources to which the received electromagnetic radiation was directed. Method and other embodiments are also disclosed.

Fink, Patrick W.↗

Systems and Methods for Beam Forming RFID Tags

A radio frequency identification (RFID) system includes an RFID interrogator and an RFID tag having a plurality of information sources and a beamforming network. The tag receives electromagnetic radiation from the interrogator. The beamforming network directs the received electromagnetic radiation to a subset of the plurality of information sources. The RFID tag transmits a response to the received electromagnetic radiation, based on the subset of the plurality of information sources to which the received electromagnetic radiation was directed. Method and other embodiments are also disclosed.

Fink, Patrick W.↗