Search NASA⌕ Search

SEARCH · Search NASA

Results for “electromechanical parts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

129 records · Page 8

Advancements in Force and Angle Measurement by the NFMTC

The National Force Measurement Technology Capability (NFMTC) is a nationwide partnership established in 2008 and sponsored by NASA’s Aeronautics Evaluation and Test Capabilities (AETC) project to maintain and further develop force and angle measurement capabilities primarily for NASA’s ground test facilities. One of the NFMTC’s primary objectives is to develop new force and angle measurement capabilities to meet the needs of researchers testing in NASA’s ground test facilities. This work will highlight several new capabilities that are either at or near operational readiness. A new six-component flow-through balance was designed and fabricated to support an upcoming retropropulsion test campaign at the NASA Langley Unitary Plan Wind Tunnel. The balance employs membranes in place of bellows, which have historically been used, and passes the flow through load bearing parts of the balance. Flow through the balance is optimized via the addition of flow guides, which are manufactured as separate parts, and attached to the balance. Calibration of this new flow-through balance demonstrates that it can suitably characterize the load and pressure ranges it was designed for, which provides aero researchers a new tool to directly measure retropropulsion performance of powered descent vehicles. Balances used in NASA’s ground test facilities are typically either single-piece balances or floating-frame balances. Historically, these two types of balances have generally used different front-end (model) attachments. Single-piece balances generally have a cylindrical front end that is forward of any measuring sections and at a reduced diameter relative to the balance outer diameter. Floating-frame balances generally have front end fits that extend over one or more measuring sections and that engage at the balance outer diameter. Recently, the NFMTC fabricated a single-piece balance with a front end fit that is compatible with the hardware used to calibrate floating-frame balances. Calibration results evaluating this front end fit will be presented. From a recent survey of angle measurement needs, the development of smaller angle measurement packages was identified as one area of improvement. Micro-electromechanical systems (MEMS) are continually being refined to provide high performance accelerometers that are a fraction of the volume of the quartz flexure based accelerometers that are standard in wind tunnels. A survey of commercial off-the-shelf MEMS accelerometers was conducted, and it identified the Safran Colibrys MS lines to be of adequate performance. Single-axis test boards and tri-axis rigid-flex production boards were designed and fabricated with a volume of approximately .18 cubic inches. The boards were designed to provide all the necessary conditioning for the MEMS accelerometers at levels to meet or exceed all requirements for the MS line sensors. Preliminary testing of these assembled sensor packages has demonstrated acceptable performance for wind-tunnel angle measurement. Several new rotating balances are at various stages of completion for NASA Glenn Research Center’s fan drive rigs. These balances provide direct measurement of thrust and torque of a driven fan or fan section to provide an estimate of fan efficiency and net thrust. Three two-component balances have been recently completed, and one six-component balance is in active development. A custom rotating telemetry system has been developed to support testing with these balances, and the telemetry system is integrated into the forward end of each one. The telemetry system is designed to remove mechanical sliprings by using an optical ethernet-based slipring for data transmission.

Force measurement↗

Carbon Nanotubes as Resonators for RF Spectrum Analyzers

Electromechanical resonators of a proposed type would comprise single carbon nanotubes suspended between electrodes (see Figure 1). Depending on the nanotube length, diameter, and tension, these devices will resonate at frequencies in a range from megahertz through gigahertz. Like the carbon-nanotube resonators described in the preceding article, these devices will exhibit high quality factors (Q values), will be compatible with integration with electronic circuits, and, unlike similar devices made from silicone and silicone carbide, will have tunable resonant frequencies as high as several GHz. An efficient electromechanical transduction method for the carbon nanotube resonators is provided by the previously observed variation of carbon nanotube length with charge injection. It was found that injection of electrons or holes, respectively, lengthens or shortens carbon nanotubes, by amounts of the order of a percent at bias levels of a few volts. The charge-dependent length change also enables a simple and direct means of tuning the resonant frequency by varying the DC bias and hence the tension along the tube, much like tuning a guitar string. In its basic form, the invention is a tunable high-Q resonator based on a suspended carbon nanotube bridge with attached electrodes (see Figure 1). An applied DC bias controls the tension and thus the frequency of resonance. If one were to superimpose a radio-frequency (RF) bias on the DC bias, then the resulting rapid variation in tension or length would set the tube into vibration. If, on the other hand, the carbon nanotube were to be set into vibration by interaction between an incident RF electric field and electric charges in the nanotube, then the vibration would give rise to an RF signal output that is proportional to the RF amplitude at the resonance frequency. Because the transduction mechanism is extremely sensitive and the active volume is only a few nanometers in diameter, this device is not well suited for use as a microwave power device. Instead, this carbon nanotube mechanical resonator would be useful primarily as part of a highly precise, sensitive, frequency-selective detector. An array of such devices featuring nanotubes of different lengths (and thus different frequencies) could be made to operate as a highspeed spectrum analyzer (see Figure 2)

Hunt, Brian↗

Development of electrochemical super capacitors for EMA applications

In a NASA SBIR Phase I program (Contract No. NAS8-40119), Giner, Inc. evaluated the feasibility of fabricating an all-solid-ionomer multicell electrochemical capacitor having a unit cell capacitance greater than 2 F/sq cm and a repeating element thickness of 6 mils. This capacitor can possibly be used by NASA as a high-rate energy source for electromechanical actuator (EMA) activation for advanced space missions. The high unit cell capacitance and low repeating element thickness will allow for the fabrication of a low-volume, low-weight device, favorable characteristics for space applications. These same characteristics also make the capacitor attractive for terrestrial applications, such as load-leveling batteries or fuel cells in electric vehicle applications. Although the projected energy densities for electrochemical capacitors are about two orders of magnitude lower than that of batteries, the high-power-density characteristics of these devices render them as potentially viable candidates for meeting pulse or peak electrical power requirements for some anticipated aerospace mission scenarios, especially those with discharge times on the millisecond to second time scale. On a volumetric or gravimetric basis, the advantages of utilizing electrochemical capacitors rather than batteries for meeting the peak power demands associated with a specific mission scenario will largely depend upon the total and pulse durations of the power peaks. The effect of preparation conditions on RuO(x), the active component in an all-solid-ionomer electrochemical capacitor, was evaluated during this program. Methods were identified to prepare RuO(x) having a surface areagreater than 180 sq m/g, and a capacitance of greater than 2 F/sq cm. Further efforts to reproducibly obtain these high-surface-area materials in scaled-up batches will be evaluated in Phase 2. During this Phase 1 program we identified a superior Nafion 105 membrane, having a film thickness of 5 mils, that showed excellent performance in our all-solid-ionomer capacitors and resulted in electrochemical capacitors with a repeating element thickness of 8 mils. We are currently working with membrane manufacturers to obtain a high performance membrane in less than 3 mil thickness to obtain a repeating element thickness of 6 mils or less. A 10-cell all-solid ionomer capacitor stack, with each cell having a 222 sq cm active area, was fabricated and evaluated as part of the Phase 1 program. Further Scale-up of a high-energy-density stack is plannedin Phase 2.

Kosek, J. A.↗