Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beam imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Effects of Applied Interfacial Pressure on Li-Metal Cycling Performance and Morphology in 4 M LiFSI in DME

Lithium-metal anodes can theoretically enable 10x higher gravimetric capacity than conventional graphite anodes. However, Li-metal anode cycling has proven difficult due to porous and dendritic morphologies, extensive parasitic solid electrolyte interphase reactions, and formation of dead Li. We systematically investigate the effects of applied interfacial pressure on Li-metal anode cycling performance and morphology in the recently developed and highly efficient 4 M lithium bis(fluorosulfonyl)imide in 1,2-dimethoxyethane electrolyte. We present cycling, morphology, and impedance data at a current density of 0.5 mA/cm 2 and a capacity of 2 mAh/cm 2 at applied interfacial pressures of 0, 0.01, 0.1, 1, and 10 MPa. Cryo-focused ion beam milling and cryo-scanning electron microscopy imaging in cross section reveal that increasing the applied pressure during Li deposition from 0 to 10 MPa leads to greater than a fivefold reduction in thickness (and therefore volume) of the deposited Li. This suggests that pressure during cycling can have a profound impact on the practical volumetric energy density for Li-metal anodes. A “goldilocks zone” of cell performance is observed at intermediate pressures of 0.1–1 MPa. Increasing pressure from 0 to 1 MPa generally improves cell-to-cell reproducibility, cycling stability, and Coulombic efficiency. However, the highest pressure (10 MPa) results in high cell overpotential and evidence of soft short circuits, which likely result from transport limitations associated with increased pressure causing local pore closure in the separator. All cells exhibit at least some signs of cycling instability after 50 cycles when cycled to 2 mAh/cm 2 with thin 50 μm Li counter electrodes, though instability decreases with increasing pressure. In contrast, cells cycled to only 1 mAh/cm 2 perform well for 50 cycles, indicating that capacity plays an important role in cycling stability.

25 ENERGY STORAGE↗

Revealing the aging process of solid electrolyte interphase on SiOx anode

Abstract As one of the most promising alternatives to graphite negative electrodes, silicon oxide (SiO x ) has been hindered by its fast capacity fading. Solid electrolyte interphase (SEI) aging on silicon SiO x has been recognized as the most critical yet least understood facet. Herein, leveraging 3D focused ion beam-scanning electron microscopy (FIB-SEM) tomographic imaging, we reveal an exceptionally characteristic SEI microstructure with an incompact inner region and a dense outer region, which overturns the prevailing belief that SEIs are homogeneous structure and reveals the SEI evolution process. Through combining nanoprobe and electron energy loss spectroscopy (EELS), it is also discovered that the electronic conductivity of thick SEI relies on the percolation network within composed of conductive agents (e.g., carbon black particles), which are embedded into the SEI upon its growth. Therefore, the free growth of SEI will gradually attenuate this electron percolation network, thereby causing capacity decay of SiO x . Based on these findings, a proof-of-concept strategy is adopted to mechanically restrict the SEI growth via applying a confining layer on top of the electrode. Through shedding light on the fundamental understanding of SEI aging for SiO x anodes, this work could potentially inspire viable improving strategies in the future.

25 ENERGY STORAGE↗

Dose-Weighted Radiographic Source-Spot Size

The spatial resolution of a flash radiograph is determined by the time-integrated size of the radiation source. Since the radiation pulse includes the beam head and tail, which may be substantially larger than the beam body, the radiation source is larger than the focused flattop of the electron beam pulse. Moreover, the radiation dose rate is weighted by both beam current and electron energy, and it is the radiation dose that forms the radiograph image. Therefore, in order to estimate radiographic resolution from computer simulations of a focused electron beam, one should use a dose weighted moment analysis of the radiation source distribution. This approach is used to show that, in the absence of beam effects other than space-charge and emittance, radiographic resolution for Scorpius exceeds requirements, regardless of reasonable timing options for current and gap-voltage pulses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Free suspension processing of oxides to form amorphous oxide materials, appendix B

The processing of yttria, zirconia, and alumina under weightless conditions is discussed. The process consists of levitation or position control, heating and melting, superheating, and supercooling. The use of arc imaging furnaces, lasers, induction heating, microwave, and electron beam methods are analyzed to show the advantages and disadvantages of each.

Wouch, G.↗

Identification of Presolar Spinel Grains from a Murray Residue by Multi-Detection Raster Imaging

Grain size separate CG from the Murray CM2 carbonaceous chondrite contains mostly spinel grains of average diameter 0.5 m. Zinner et al. found that approximately 1% of these spinel grains are of presolar origin as determined by their large O isotopic anomalies. These O isotopic measurements were made with the NanoSIMS on individual grains that were well separated from one another on a gold foil. The grains were selected for analysis from secondary electron and secondary O-16(-) images. The primary beam was then successively deflected onto these single grains for O isotopic analysis. While single grain analysis on dispersed samples is effective for finding relatively abundant anomalous grains, ion imaging in a raster mode on tightly packed grains might be more efficient for locating few anomalous grains among predominantly isotopically normal grains. In fact, this was the analysis mode used by Messenger et al. to discover presolar silicates in interplanetary dust particles. In an exploratory effort that is also geared toward establishing the optimum isotopic imaging technique in the search for presolar silicate grains in primitive meteorites, we measured O isotopic ratios in spinel grains from the Murray CG separate by raster imaging of areas with more or less tightly packed grains.

Nguyen, A.↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.↗

The JWST/NIRCam Coronagraph Flight Occulters

The NIRCam instrument on the James Webb Space Telescope will have a Lyot coronagraph for high contrast imaging of extrasolar planets and circumstellar disks at lambda = 2 - 5 micrometers. Half-tone patterns are used to create graded-transmission image plane masks. These are generated using electron beam lithography and reactive ion etching of a metal layer on an antireflection coated sapphire substrate. We report here on the manufacture and evaluation of the flight occulters.

extrasolar planets↗

Understanding and quantifying electron beam effects during in situ TEM nanomechanical tensile testing on metal thin films

Transmission electron microscopy (TEM) imaging relies on high energy electrons for atomic scale resolution, however, the electrons themselves interact with and may alter the material being imaged. Using an in situ TEM MEMS-based nanomechanical testing technique, the effect of the electron beam (e-beam) on the deformation behavior of nanocrystalline Al and ultrafine-grained Au is investigated and quantified. We show that the e-beam enhances plastic deformation, leading to an increase in plastic strain rate and a decrease in true activation volume V* in Al (28 to 21b 3 , with b being the Burgers vector length). The e-beam has a much weaker effect on Au. The e-beam effect is not caused by knock-on damage, but rather an effective temperature increase due to additional atomic fluctuations provided by the e-beam. The effective temperature increase is larger for Al than Au. This e-beam effect does not change the deformation mechanisms, but instead accelerates the stress-driven, thermally activated plastic deformation. These experiments provide insight into the effects of the e-beam on plastic deformation in different metals and underscore the importance of understanding and quantifying these effects for proper interpretation of measured mechanical properties during in situ TEM experiments.

36 MATERIALS SCIENCE↗

High-resolution planar electron beam induced current in bulk diodes using high-energy electrons

Understanding the impact of high-energy electron radiation on device characteristics remains critical for the expanding use of semiconductor electronics in space-borne applications and other radiation harsh environments. Here in this paper, we report on in situ measurements of high-energy electron radiation effects on the hole diffusion length in low threading dislocation density homoepitaxial bulk n-GaN Schottky diodes using electron beam induced current (EBIC) in high-voltage scanning electron microscopy mode. Despite the large interaction volume in this system, quantitative EBIC imaging is possible due to the sustained collimation of the incident electron beam. This approach enables direct measurement of electron radiation effects without having to thin the specimen. Using a combination of experimental EBIC measurements and Monte Carlo simulations of electron trajectories, we determine a hole diffusion length of 264 ± 11 nm for n-GaN. Irradiation with 200 kV electron beam with an accumulated dose of 24 × 10 16 electrons cm -2 led to an approximate 35% decrease in the minority carrier diffusion length.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dispersion calibration for the National Ignition Facility electron–positron–proton spectrometers for intense laser matter interactions

Electron–positron pairs, produced in intense laser–solid interactions, are diagnosed using magnetic spectrometers with image plates, such as the National Ignition Facility Electron–Positron–Proton Spectrometers (EPPSs). Although modeling can help infer the quantitative value, the accuracy of the models needs to be verified to ensure measurement quality. The dispersion of low-energy electrons and positrons may be affected by fringe magnetic fields near the entrance of the EPPS. We have calibrated the EPPS with six electron beams from a Siemens Oncor linear accelerator (linac) ranging in energy from 2.7 MeV to 15.2 MeV as they enter the spectrometer. A Geant4 Tool for Particle Simulation Monte Carlo simulation was set up to match depth dose curves and lateral profiles measured in water at 100 cm source–surface distance. An accurate relationship was established between the bending magnet current setting and the energy of the electron beam at the exit window. The simulations and measurements were used to determine the energy distributions of the six electron beams at the EPPS slit. Furthermore, analysis of the scanned image plates together with the determined energy distribution arriving in the spectrometer provides improved dispersion curves for the EPPS.

47 OTHER INSTRUMENTATION↗

An electromagnetic/electrostatic dual cathode system for electron beam instruments

A method of providing cathode redundancy which consists of two fixed cathodes and uses electromagnetic and/or electrostatic fields to direct the electron beam to the electron optical axis is presented, with application to the cathode system of the Scanning Electron Microscope and Particle Analyzer proposed for NASA's Mariner Mark II Comet Rendezvous/Asteroid Flyby projected for the 1990s. The symmetric double deflection system chosen has the optical property that the image of the effective electron source is formed above the magnet assembly near the apparent position of the effective source, and it makes the transverse positions of the electron sources independent of the electron beam energy. Good performance of the system is found, with the sample imaging resolution being the same as for the single-axis cathode.

Bradley, J. G.↗

Space plasma physics results from Spacelab 1

The Spacelab 1 payload carried several instrument systems which together investigated a number of space plasma phenomena. These experiments used the Space Shuttle Orbiter as a platform for making controlled particle-beam, plasma and neutral gas inputs to the ionosphere and magnetosphere and for observing the outputs produced. Spacelab 1 space-plasma investigations included the Space Experiments with Particle Accelerators (SEPAC), Phenomena Induced by Charged Particle Beams (PICPAB), Atmospheric Emissions Photometric Imaging (AEPI) and the Low Energy Electron Spectrometer and Magnetometer. Among the major phenomena investigated both singly and jointly by these experiments are vehicle charging and neutralization, beam-plasma and wave-particle interactions, anomalous ionization phenomena produced by neutral-gas and plasma injections and several phenomena induced by modulated particle beam injections.

Burch, J. L.↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

Plasma Focused Ion Beam Nanothermometry

In this report we detail demonstration of temperature dependent effects on grayscale intensity imaged in Focused Ion Beam (FIB) microscope, as well as secondary electron (SE) dependence on temperature in the Auger Electron Spectroscopy (AES) and a Scanning Electron Microscope (SEM). In each instrument an intrinsic silicon sample is imaged at multiple temperatures over the course of each experiment. The grayscale intensity is shown to scale with sample temperature. Sample preparation procedures are discussed, along with hypothesized explanations for unsuccessful trials. Anticipated outcomes and future directions for these measurements are also detailed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Advanced Laser-driven Plasma Accelerator Electron-beam Diagnostics with COTR Techniques

A significant advance in laser-driven plasma accelerator (LPA) electron-beam diagnostics has recently been demonstrated based on coherent optical transition radiation (COTR) imaging. We find COTR signal strengths from a microbunched subset of beam exiting the LPA to be several orders of magnitude higher than that of incoherent optical transition radiation (OTR). The transverse sizes are only a few microns as deduced from the point-spread-function-related lobe structure. In addition, the far-field COTR interferometric images obtained on the same shot provide beam-size limits plus divergence and pointing information at the sub-mrad level when compared to a modified analytical model. The integrated image intensities can be used to estimate the microbunching fraction and relatable to the LPA process. Initial results in a collaborative LPA experiment will be reported for electron beam energies of about 215 MeV. A revised configuration is proposed to record energy and ene rgy spread via COTR on the same shot with the interferometer.

43 PARTICLE ACCELERATORS↗

Unraveling Li growth kinetics in solid electrolytes due to electron beam charging

Revealing the local structure of solid electrolytes (SEs) with electron microscopy is critical for the fundamental understanding of the performance of solid-state batteries (SSBs). However, the intrinsic structural information in the SSB can be misleading if the sample’s interactions with the electron beams are not fully understood. In this work, we systematically investigate the effect of electron beams on Al-doped lithium lanthanum zirconium oxide (LLZO) under different imaging conditions. Li metal is observed to grow directly on the clean surface of LLZO. The Li metal growth kinetics and the morphology obtained are found to be heavily influenced by the temperature, accelerating voltage, and electron beam intensity. We prove that the lithium growth is due to the LLZO delithiation activated by a positive charging effect under electron beam emission. Our results deepen the understanding of the electron beam impact on SEs and provide guidance for battery material characterization using electron microscopy.

36 MATERIALS SCIENCE↗

Estimating Beam-Target Heating

At Los Alamos National Laboratory, two high-current linear induction accelerators (LIAs) are used to produce bremsstrahlung source spots for flash radiography of high-explosive driven hydrodynamic experiments at the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility. Measurements of the electron-beam current density profile are valuable for understanding the beam dynamics in order to improve the quality of the radiography source spot. A technique commonly used at DARHT is to image the profile in Cerenkov or Optical Transition Radiation (OTR) light created by the beam striking a thin target inserted into the beam line. Target materials include aluminized dielectrics and titanium foils for OTR, and fused silica wafers for Cerenkov radiation. A practical complication with this technique is heating of the target by the electron beam. If the beam density is too great, the target can be destroyed. Moreover, even if the beam density is kept low enough to be nondestructive, the beam can heat the target to a high enough temperature to desorb gas from the surface. In that case, direct impact ionization of the gas by beam electrons can partially neutralize the beam, causing it to over-focus, thereby spoiling the data, if not destroying the target. The purpose of this note is to review some of the fundamental physics of electron beam heating in order to provide some elementary guidance for design of these imaging experiments to avoid overheating the target. Some specific examples for materials that we often use for imaging targets and beam-target experiments are provided.

43 PARTICLE ACCELERATORS↗