Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beam irradiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

ToF-SIMS spectral analysis of pristine and neutron irradiated single crystal tungsten

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying materials including high spatial resolution and high mass accuracy of elements, molecules, and isotopes. Its ability to resolve isotopes is especially attractive in studying transmutation products of single crystal tungsten (SCW) post neutron irradiation. Tungsten (W) is a contender of plasma facing materials (PFMs) due to its high thermal and radiological stability. PFMs to be used in the construction of fusion vessels are subject to high temperature and neutron irradiation, resulting in changes to materials including transmutation, which ultimately impact material mechanical and thermal properties. We used IONTOF TOF.SIMS V instrument equipped with a 30 keV Bi 3 + primary ion beam to study pristine SCW and irradiated SCW speciemens. Scanning electron microscope coupled with focused ion beam (SEM-FIB) was used to reduce the dosage of neutron irradiated tungsten and prepare for specimens for SIMS analysis. Static ToF-SIMS spectra were obtained, and transmutation product peak identification was presented in this work. Identified molecules and molecular fragments were compared against isotope theoretical mass to charge ratios of tungsten, rhenium, osmium, and other relevant products. Our results show that ToF-SIMS provides a viable means to study transmutation products of W post neutron irradiation. Such applications are suitable to investigate transmutation effects on materials that are being considered and developed for fusion pilot plants.

36 MATERIALS SCIENCE↗

Flow Measurements in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m) is vital to the medical imaging community. It is a radioactive tracer that emits gamma rays as it decays and it is these gamma rays that are then detected through imaging. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. One method of generating Mo-99 is using accelerator based technology, through the irradiation of Mo-100 using an electron beam. This is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and requires extensive cooling of the Mo-100 targets and target housing using pressurized helium gas. Before beam on target, the design of the target stack and target housing is tested at LANL using laser based diagnostics experiments. We quantify the velocity field of the helium gas around the target housing to estimate whether the cooling provided is sufficient for the design and to validate computational fluid dynamics (CFD) models. Fiber optic imaging is also developed for use during cold testing (without beam on target) as well as during irradiation, to obtain real time information on disc performance.

07 ISOTOPE AND RADIATION SOURCES↗

High-resolution planar electron beam induced current in bulk diodes using high-energy electrons

Understanding the impact of high-energy electron radiation on device characteristics remains critical for the expanding use of semiconductor electronics in space-borne applications and other radiation harsh environments. Here in this paper, we report on in situ measurements of high-energy electron radiation effects on the hole diffusion length in low threading dislocation density homoepitaxial bulk n-GaN Schottky diodes using electron beam induced current (EBIC) in high-voltage scanning electron microscopy mode. Despite the large interaction volume in this system, quantitative EBIC imaging is possible due to the sustained collimation of the incident electron beam. This approach enables direct measurement of electron radiation effects without having to thin the specimen. Using a combination of experimental EBIC measurements and Monte Carlo simulations of electron trajectories, we determine a hole diffusion length of 264 ± 11 nm for n-GaN. Irradiation with 200 kV electron beam with an accumulated dose of 24 × 10 16 electrons cm -2 led to an approximate 35% decrease in the minority carrier diffusion length.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy Evaluation of Electron Beam Treatment of Perfluoroalkyl Substances in Water: A Critical Review

Due to their recalcitrant nature and ubiquitous use, per- and polyfluoroalkyl substances (PFAS) will continue to be major water treatment hurdles. Although effective water treatment technologies exist for physical removal of many PFAS from water (e.g., activated carbon and ion-exchange resin), a PFAS-concentrated waste stream is generated as an end product that can potentially reintroduce PFAS back into the environment. Thus, there is an increased interest in developing destructive technologies to decompose and mineralize PFAS directly in water or in these waste streams. High energy electron beam (e-beam) accelerators have been used for water treatment to degrade a wide range of recalcitrant contaminants, including PFAS, since the 1960s. However, large-scale applications of e-beam for water treatment are restricted due to its high energy consumption and inability to treat large flow rates. Considering there are very few available technologies for destructive removal of PFAS, this study provides a critical review on the treatment of PFAS by direct irradiation of contaminated water by e-beam from an energy consumption point of view. To date, very limited studies have been conducted to investigate the success of this technology to treat PFAS. Results from the limited studies were not directly comparable due to the variation in operating conditions and water quality parameters used in the studies. Here, for the first time, we develop and apply the concept of electrical energy per order (EE/O) to assess the performance of e-beam for PFAS treatment. Results show that EE/O is a better performance parameter than the G value of e-beam for interstudy comparisons and to evaluate the effects of water quality and operating parameters on e-beam performance. We additionally developed a kinetic scheme to predict the performance of e-beam to treat PFAS and revealed that the competition between species to react with aqueous electrons is the determinant factor influencing PFAS degradation efficiency. Comparison of EE/O values of e-beam (range: 31–176 kWh m –3 order –1 ) with other destructive technologies (range: 5–9595 kWh m –3 order –1 ) suggest that e-beam, for PFAS treatment, is a promising approach under favorable conditions. Furthermore, this review further elucidates the feasibility and limitations of e-beam technology that could be improved upon to potentially make e-beam viable for large-scale water treatment applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process. During irradiation, pressurized helium gas flows through 0.25 mm thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo-100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Longer duration testing will provide more data and verification for the findings presented in this report. The work will be continued in FY 24.

43 PARTICLE ACCELERATORS↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Effects of electron irradiation on large insulating surfaces used for European Communications Satellites

Samples of aluminized Kapton used for passive thermal control on the VHF shield and the antenna dish of ESA's OTS satellite and its derivatives were subjected to an incident electron beam of 25 keV and irradiated for 8 hours at room temperature and at -173 C under a vacuum of the 10 to the minus 6 th power torr. Visual observations during electron irradiation, measurements of leakage current and discharge characteristics, and material degradation following completion of irradiation are discussed.

Reddy, J.↗

Tiny Bubbles: Combined HR(S)TEM and 4D-STEM Analysis of Sub-Nanometer He Bubbles in Au

Irradiation produces a distribution of defect sizes in materials, with the smallest defects often below one nanometer in size and approaching the scale of a single unit cell in metals. While high-resolution scanning transmission electron microscopy (STEM)-based imaging can directly image structures at this level, techniques such as four-dimensional STEM (4D-STEM) enable characterization of materials across large fields of view, capturing a more representative volume that can be valuable for quantifying defects, their distributions, and the associated strain fields. Here we present a combined HRSTEM and 4D-STEM approach to study the model system of He bubble implantation in an Au thin film. The present work is of general interest for the study of materials in extreme environments, as it demonstrates an effective way to characterize even the tiniest sub-nanometer sized He bubbles in addition to larger irradiation defects.

atomic-resolution STEM↗

Corrosion behavior of ferritic FeCrAl alloys in simulated BWR normal water chemistry

Ferritic iron-chromium-aluminum (FeCrAl) alloys with varying Cr content were subjected to in-situ irradiation-corrosion with energetic protons or electron beams in pure water with various oxygen concentrations. Oxide microstructure and composition were characterized to compare the corrosion under irradiation with the thermal corrosion in the same water conditions. The dominant effect seems to be the production of H 2 O 2 at the surface by the intense proton and electron beams. The corrosion potential of FeCrAl under BWR-NWC condition is somewhat above the Cr 2 O 3 /CrO 4 2- phase boundary, oxidizing the Cr(III) to Cr(VI) in the outer part of the film, but with some Cr(III) remaining in the interior of the oxide. The beam increases the corrosion potential, significantly reducing Cr(III) content throughout the oxide. Finally, the crystallites on the surface, which form by re-precipitation from solution, do not contain Cr because at low potential Cr(III) is not soluble, and at high potential Cr(VI) is quite soluble.

36 MATERIALS SCIENCE↗

First-Principles Simulation of Beam-Induced Processes Underlying Atomic Manipulation in Electron Microscopes

The development of experimental methods and apparatuses capable of promoting atomically precise material manipulations holds great promise for realizing the ultimate limit of feature miniaturization in materials and devices. The ability to modify materials atom by atom is anticipated to usher in new technologies in areas as diverse as separation science, medicine, and quantum information science. Historically, scanning probe-based techniques have been the most prominent approaches in this space. However, these methods are best suited for the manipulation of surface-exposed regions of materials, as the strong perturbations required for bond scission are delivered most effectively to atoms in the near-proximity to the scanning probe. In contrast, convergent electron beams with energies tuned slightly below the threshold for inducing irreversible knock-on damage have recently been employed (within scanning transmission electron microscopy) to promote atomic-scale bond rearrangements in various beam-stable solids. Currently, however, the efficiency and selectivity of beam-induced atomic manipulation processes with focused electron beams are such that long irradiation times are required to induce a desired atomic rearrangement. With a better understanding of the underlying physics dictating the outcome of a given irradiation event, methods can be devised to improve the efficiency of these techniques so that their promise can be fully realized through widespread adoption.To this end, this Account details our recent efforts to develop and apply tractable first-principles simulation approaches for studying the response of materials to electric beam-like external electric potentials applied in real space. We briefly review the concepts and capabilities in the area of atomically precise materials manipulation and review the early demonstrations of accomplishments in this area, focusing on studies using scanned convergent electron beam probes in particular. We expound upon the depth of the challenge and identify critical shortcomings of theoretical methods that have previously been employed in the simulation of beam-induced processes. We then describe the computational methods that we have generalized from the concepts and tools most commonly applied to the study of molecular photochemistry and how our adaptations of these methods can be employed to capture the relevant dynamical phenomena for beam-induced processes ranging from the initial electron scattering to the ensuing multistate reactions. Here, we contextualize these methods within the current state of the art in this area, which has historically focused primarily on the simulation of inelastic image formation in the electron microscope for the purpose of interpreting the results of quantitative electron microscopy experiments. We demonstrate that the spatial distribution of state-specific excitation rates due to the presence of an external (probe) electric charge is inhomogeneous, such that irradiation at particular locations in materials can favor specific electronic transitions (and disallow others). In addition to the potential for excited-state reaction pathways to be accessed through the initial inelastic scattering of the tightly focused electron beam from the targeted atoms, we also identify favorable conditions for the electronically nonadiabatic evolution of the highly vibrationally excited system to open complex multistate reaction pathways. Implications of the early results for understanding the mechanisms and potential routes to improved efficiency and selectivity in beam-induced reactions are discussed. We conclude with a summary of the current state of theory and modeling capabilities in this area and provide our perspective on future directions for theoretical and experimental developments that we view as crucial to advancing the use of convergent electron beams in mode-specific, atomically precise platforms for direct-write materials modifications.

36 MATERIALS SCIENCE↗

Simulation Studies on the Interactions of Electron Beam with Wastewater

The manufactured chemical pollutants, like 1,4 dioxane and PFAS (per- and polyfluroralkyl substances), found in the underground water and/or drinking water are challenging to be removed or biodegraded. Energetic electrons are capable of mediating and removing them. This paper utilizes FLUKA code to evaluate the beam-wastewater interaction effects with different energy, space and divergence distributions of the electron beam. With 8 MeV average energy, the electron beam exits from a 0.0127 cm thick titanium window, travels through a 4.3 cm distance air and a second 0.0127 cm thick stainless water container window with 2.43 cm radius, and finally is injected into the water area, where the volume of water is around 75 cubic cm. The distribution parameters of the electron beam are from the GPT (General Particle Tracer) simulations for UITF (Upgraded Injector Test Facility) in Jefferson lab. By varying the distributions, several measurements including the dose (or energy deposition) distribution, electron fluence, photon fluence are scored and compared. Taking the comparisons into consideration, this paper is aiming to find better electron beams for the wastewater irradiation.

Li, X.↗

Simulation Studies on the Interactions of Electron Beam with Wastewater

The manufactured chemical pollutants, like 1,4 dioxane and PFAS (per- and polyfluroralkyl substances), found in the underground water and/or drinking water are challenging to be removed or biodegraded. Energetic electrons are capable of mediating and removing them. This paper utilizes FLUKA code to evaluate the beam-wastewater interaction effects with different energy, space and divergence distributions of the electron beam. With 8 MeV average energy, the electron beam exits from a 0.0127 cm thick titanium window, travels through a 4.3 cm distance air and a second 0.0127 cm thick stainless water container window with 2.43 cm radius, and finally is injected into the water area, where the volume of water is around 75 cubic cm. The distribution parameters of the electron beam are from the GPT (General Particle Tracer) simulations for UITF (Upgraded Injector Test Facility) in Jefferson lab. By varying the distributions, several measurements including the dose (or energy deposition) distribution, electron fluence, photon fluence are scored and compared. Taking the comparisons into consideration, this paper is aiming to find better electron beams for the wastewater irradiation.

Li, X.↗

Laboratory simulation of irradiation-induced dielectric breakdown in spacecraft charging

The discharging of dielectric samples irradiated by a beam of monoenergetic electrons is investigated. The development of a model, or models, which describe the discharge phenomena occuring on the irradiated dielectric targets is discussed. The electrical discharge characteristics of irradiated dielectric samples are discussed and the electrical discharge paths along dielectric surfaces and within the dielectric material are determined. The origin and destination of the surface emitted particles is examined and the charge and energy balance in the system is evaluated.

Yadlowsky, E. J.↗

Characteristics of edge breakdowns on Teflon samples

The characteristics of electrical discharges induced on silverbacked Teflon samples irradiated by a monoenergetic electron beam have been studied under controlled laboratory conditions. Measurements of breakdown threshold voltages indicate a marked anisotropy in the electrical breakdown properties of Teflon: differences of up to 10 kV in breakdown threshold voltage are observed depending on the sample orientation. The material anisotropy can be utilized in spacecraft construction to reduce the magnitude of discharge currents.

Yadlowsky, E. J.↗

Effects of low-temperature neutron irradiation on the microstructure and tensile properties of duplex 2304 stainless steel and its electron-beam welds

A lean duplex stainless steel material (2304-grade) in its base metal and electron beam (e-beam) welded conditions were studied microstructurally and mechanically as a function of irradiation conditions to evaluate its use as a structural material at low temperatures (60–100 °C). Neutron irradiation up to a fluence of 1.40 × 10 19 n/cm 2 (E > 0.1 MeV) or ~0.011 dpa decreased the total elongation of both base metal and e-beam welded samples. Overall, radiation hardening was observed in all the samples. The transversely cut irradiated samples showed some nonuniform quasi-cleavage and shearing in their fracture surfaces, indicating the variance of ductile nature of the two-phased (deformable austenite and harder ferrite) duplex structure. The e-beam welded samples also showed quasi-cleavage fracture, which is a characteristic of radiation-induced embrittlement. Furthermore, these observations of the e-beam welded samples were attributed to the formation of coarse ferrites, grain boundary and intragranular phases such as γ 2 and γ 3 , and minor impurity phases such as CrN and Cr 2 N in the weld pool and/or heat-affected zone of the samples. Radiation-induced elemental segregation was also identified in the post-irradiated base metal.

36 MATERIALS SCIENCE↗

Designs and Materials for Better Coronagraph Occulting Masks

New designs, and materials appropriate for such designs, are under investigation in an effort to develop coronagraph occulting masks having broad-band spectral characteristics superior to those currently employed. These designs and materials are applicable to all coronagraphs, both ground-based and spaceborne. This effort also offers potential benefits for the development of other optical masks and filters that are required (1) for precisely tailored spatial transmission profiles, (2) to be characterized by optical-density neutrality and phase neutrality (that is, to be characterized by constant optical density and constant phase over broad wavelength ranges), and/or (3) not to exhibit optical- density-dependent phase shifts. The need for this effort arises for the following reasons: Coronagraph occulting masks are required to impose, on beams of light transmitted through them, extremely precise control of amplitude and phase according to carefully designed transmission profiles. In the original application that gave rise to this effort, the concern has been to develop broad-band occulting masks for NASA s Terrestrial Planet Finder coronagraph. Until now, experimental samples of these masks have been made from high-energy-beam-sensitive (HEBS) glass, which becomes locally dark where irradiated with a high-energy electron beam, the amount of darkening depending on the electron-beam energy and dose. Precise mask profiles have been written on HEBS glass blanks by use of electron beams, and the masks have performed satisfactorily in monochromatic light. However, the optical-density and phase profiles of the HEBS masks vary significantly with wavelength; consequently, the HEBS masks perform unsatisfactorily in broad-band light. The key properties of materials to be used in coronagraph occulting masks are their extinction coefficients, their indices of refraction, and the variations of these parameters with wavelength. The effort thus far has included theoretical predictions of performances of masks that would be made from alternative materials chosen because the wavelength dependences of their extinction coefficients and their indices of refraction are such that that the optical-density and phase profiles of masks made from these materials can be expected to vary much less with wavelength than do those of masks made from HEBS glass. The alternative materials considered thus far include some elemental metals such as Pt and Ni, metal alloys such as Inconel, metal nitrides such as TiN, and dielectrics such as SiO2. A mask as now envisioned would include thin metal and dielectric films having stepped or smoothly varying thicknesses (see figure). The thicknesses would be chosen, taking account of the indices of refraction and extinction coefficients, to obtain an acceptably close approximation of the desired spatial transmittance profile with a flat phase profile

Balasubramanian, Kunjithapatham↗

Monte Carlo simulations demonstrating physics of equivalency of gamma, electron-beam, and X-ray for radiation sterilization

We report the sterilization of medical devices using the gamma rays from the decay of cobalt-60 has accumulated decades of experience of the performance of the materials and devices that are irradiated. The use of radiation using electron beams and x-rays has much less experience and this leads to questions of equivalency between these three technologies. Computer simulations were conducted to model the relevant physical processes of the interactions of each of the three forms of radiation in order to compare the spectra of electron energies at energies below 500 keV. It is predominantly the electrons below this threshold that produce the sterilization dose. No difference in energy spectra was seen between the three types of initial radiation. It is concluded that there is no energy dependent difference between gamma, e-beam, and x-ray for radiation sterilization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗