Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron probe data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development of PNNL’s Plutonium Metallography Capability

The goal of this project was to develop plutonium metallography capabilities and establish workflows for characterization at PNNL’s Radiological Processing Facility (RPL). Developing and expanding on this capability opens more opportunities for PNNL to better support science through collaborations with other labs, plants, and sites withing the Department of Energy Complex and through programs within the National Nuclear Security Administration. This project established metallography equipment in an air glovebox, polishing protocols, as well as radiological and facility controls and procedures so that gram quantities of plutonium metal could be analyzed on multiple characterization tools. Data was collected and analyzed on two different delta phase plutonium - Gallium samples and a calciothermically reduced alpha plutonium metal using a combination of optical and electron microscopy, powder X-ray diffraction, and atom probe tomography. This report highlights the metallography capabilities, some preliminary data collections, and plans at PNNL to support plutonium material science.

36 MATERIALS SCIENCE↗

Experimental Liquidus Study of the Ternary CaO-ZnO-SiO{sub 2} System

Phase equilibria of the ternary CaO-ZnO-SiO{sub 2} system have been investigated at 1170 °C to 1691 °C for oxide liquid in equilibrium with air and solid oxide phases: tridymite or cristobalite SiO{sub 2} (up to two immiscible liquids), pseudowollastonite (CS) CaSiO{sub 3}, rankinite (C{sub 3}S{sub 2}) Ca{sub 3}Si{sub 2}O{sub 7}, dicalcium silicate (C{sub 2}S) (Ca, Zn){sub 2}SiO{sub 4}, tricalcium silicate (C{sub 3}S) (Ca, Zn){sub 3}SiO{sub 5}, lime (Ca, Zn)O, zincite (Zn, Ca)O, willemite Zn{sub 2}SiO{sub 4} and hardystonite (melilite) Ca{sub 2}ZnSi{sub 2}O{sub 7}, covering the ranges of concentrations not studied before. High-temperature equilibration on primary phase (silica) or inert metal (platinum) substrates followed by quenching and direct measurement of the Ca, Zn and Si concentrations in the phases with the electron probe X-ray microanalysis (EPMA) has been used to accurately characterize the system. Liquidus phase equilibrium data of the present authors for the CaO-ZnO-SiO{sub 2} system are essential to obtain a self-consistent set of parameters of thermodynamic models for all phases.

36 MATERIALS SCIENCE↗

Studies of the chemistry of the nightside ionosphere of Venus

A combination of numerical modeling and analysis of the Pioneer Venus UADS data base is studied, specifically data from the orbiter ion mass spectrometer (OIMS), orbiter neutral mass spectrometer (ONMS), and orbiter electron temperature probe (OETP). A one dimensional model of the Venus nightside ionosphere was set up in which downward fluxes of atomic ions are introduced at the upper boundary to simulate transport of ions from the dayside. The model shows that the densities of mass-28 ions, CO(+) + N(2+), resulting from an influx of atomic ions from the dayside are quite small, due to the high ionization potentials of CO and N2 that make chemical production difficult. A look at the data reveals that the actual densities of mass-28 ions are quite variable, from values near 10 to more than 10(exp 4) cm(exp -3). The excess mass-28 ions are assumed to be produced by electron precipitation and that the presence of high densities of mass-28 ions is a signature of auroral precipitation. A discussion of the atomic oxygen green line in the nightglow of Venus, which is produced mainly by dissociative recombination of O(2+), is presented. Original calculations of production rates of excited states for models based on Pioneer Venus data are also presented.

Fox, J. L.↗

Fast Scanning Probe Microscopy via Machine Learning: Non-Rectangular Scans with Compressed Sensing and Gaussian Process Optimization

Fast scanning probe microscopy enabled via machine learning allows for a broad range of nanoscale, temporally resolved physics to be uncovered. However, such examples for functional imaging are few in number. Here, using piezoresponse force microscopy (PFM) as a model application, a factor of 5.8 reduction in data collection using a combination of sparse spiral scanning with compressive sensing and Gaussian process regression reconstruction is demonstrated. It is found that even extremely sparse spiral scans offer strong reconstructions with less than 6% error for Gaussian process regression reconstructions. Further, the error associated with each reconstructive technique per reconstruction iteration is analyzed, finding the error is similar past ≈15 iterations, while at initial iterations Gaussian process regression outperforms compressive sensing. Finally, this study highlights the capabilities of reconstruction techniques when applied to sparse data, particularly sparse spiral PFM scans, with broad applications in scanning probe and electron microscopies.

36 MATERIALS SCIENCE↗

Symmetrization of Strong Hydrogen Bond under High Pressure in Bihydroxide-Ion-Containing NaCu 2 (SO 4 ) 2 ·H 3 O 2 Revealed by Experimental Charge Density, Single-Crystal Electron Diffraction, and Neutron Diffraction Studies

In minerals and inorganic compounds, strong hydrogen bonding can lead to the formation of complex ionic species such as the H 3 O 2 – bihydroxide anion and Zundel cation H 5 O 2 + . We studied [NaCu 2 (SO 4 ) 2 ·H 3 O 2 ] natrochalcite, which contains bihydroxide anions and undergoes hydrogen bond symmetrization at the lowest pressure reported so far among inorganic compounds. Hydrogen bond symmetrization leads to changes in the bulk modulus, seismic wave velocities, and proton mobility and plays a primary role in high-temperature superconductivity, but its characteristics are not well understood due to a lack of systematic studies and limitations of experimental methods sensitive to this subtle change. In this work, we applied experimental charge density analysis based on in situ single-crystal X-ray diffraction data, along with the single-crystal neutron and electron diffraction experiments, to probe the behavior of hydrogen atoms during the hydrogen bond symmetrization process under high-pressure conditions. On the way to the symmetrical H-bonding, natrochalcite undergoes a series of complex redistributions of electron density, which we trace with multipole refinement and detailed analysis of changes in the Laplacian of electron density values. Additionally, we deconvoluted the equation of state (volume of the unit cell vs pressure relation) into the atomic equation of states describing dependencies of atomic charges or volumes vs pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of ablation impurities on blunt body re-entry ionization

Electron density profiles which include the effect of an ablated sodium impurity were computed for the boundary layer on a blunt-nosed body re-entering the atmosphere at 7.62 km/sec. Profiles are computed from the nose to a distance of four diameters along the RAM C-payload. A finite-difference, laminar, nonequilibrium chemistry boundary-layer program was used. Comparison of theory with S-band diagnostic antenna results, electron concentration deduced from X- and C-band attenuation data, and Langmuir probe data at several different aft body locations show that agreement is good at high altitude. At the lower altitudes there is disagreement between theory and S-band antenna data where the apparent discrepancy is attributed to the three-body recombination rate constant used for deionization of sodium coupled with the effect of angle of attack.

Schexnayder, C. J., Jr.↗

Studies of noble-metal thermocouple stability at high temperatures

Two investigatory studies on performance characteristics of noble-metal thermocouples are described. (1) thermoelectric stability as affected by preferential oxidation of iridium in the system iridium-40% rhodium versus iridium, and (2) the effects of temperature gradients on the emf stability of the systems platinum-13% rhodium versus platinum and iridium-40% rhodium versus iridium, operating in air. The stability investigation was carried out at three temperatures - 1700, 1850, and 2000 C - by comparing the output of the test thermocouple in air with the output of an identically constructed reference thermocouple in nitrogen. The results show that no calibration shift was observed producing a change in output greater than that corresponding to a 2.0% change in the indicated temperature for all samples tested. The investigation of gradient effects was carried out by subjecting test thermocouples to both severe and mild gradients for periods up to 200 hours. For the platinum system, the operating temperature was 1500 C with gradients of 1475 and 700 C/cm; for the iridium system, 2000 C with gradients of 700, 1500, and 1975 C/cm. Exposure to temperature gradients was found to introduce significant changes in calibration for both systems. In both investigations, the thermoelements were examined by means of electron-probe analysis and by metallographic methods to detect chemical and structural changes. Data and micrographs are presented.

Freeze, P.↗

An experimental investigation of mesospheric ionization

Mesospheric ionization and its variability are examined. Data were obtained primarily by the parachute-borne blunt probe technique conducted in coordinated rocket experiments at White Sands Missile Range, New Mexico and Wallops Island, Virginia. Electrical conductivity measurements and deduced charge density values from ten rocket launches are presented and discussed. Positive ion conductivity and electron density were found to be relatively invariant with height between 45 and 60 km. Variations in positive conductivity of a factor of two and enhancements in negative conductivity by as much as a factor of four were measured by the blunt probe. A simple lumped parameter ion chemistry model is shown to satisfactorily explain the charge density values for the undisturbed lower D-region. Implications of the data in terms of this model are considered. The principal loss mechanism for positive ions in the 45 to 60 km. region is concluded to be dissociative recombination. Electron densities deduced from the conductivity data are explained by detachment involving a minor neutral constituent which is mixed between 65 and 45 km. and then cuts off sharply below 45 km. A correlation study involving blunt probe measurements shows relatively good agreement between variations in positive conductivity and temperature.

Mitchell, J. D.↗

Heavy Element Spectroscopy in the Gas Phase

Actinides are inherently unstable and undergo nuclear decay processes with a concurrent release of energy. Consequently, they are used for nuclear power generation, nuclear weapons, and nuclear medicine. However, the radioactive decay processes also pose significant technological problems for the safe treatment and storage of spent nuclear materials. Cost-effective extraction of the actinides is the key first step in the remediation of nuclear waste, but the appropriate chemical means have yet to be determined. Our present understanding of the chemistry of actinides is limited, with the role of the 5f electrons posing a set of particularly challenging questions. The work reported here is focused on the use of electronic spectroscopy to probe the bonding of small molecules in the gas phase that contains thorium or uranium. Analyses of these data, carried out within the framework of ligand field theory, reveal clear evidence that the 5f electrons are spectators that retain their atomic metal ion character.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characteristics of the Dust-Plasma Interaction Near Enceladus' South Pole

We present RPWS Langmuir probe data from the third Enceladus flyby (E3) showing (he presence of dusty plasma near Enceladus' South Pole. There is a sharp rise in both the electron and ion number densities when the spacecraft traverses through Enceladus plume. The ion density near Enceladus is found to increase abruptly from about 10(exp 2) cm (exp -3) before the closest approach to 10(exp 5) cm (exp -3) just 30 s after the closest approach, an amount two orders of magnitude higher than the electron density. Assuming that the inconsistency between the electron and ion number densities is due to the presence of dust particles that are collecting the missing electron charges, we present dusty plasma characteristics down to sub-micron particle sizes. By assuming a differential dust number density for a range in dust sizes and by making use of Langmuir probe data, the dust densities for certain lower limits in dust size distribution were estimated. In order to achieve the dust densities of micrometer and larger sized grains comparable to the ones reported in the literature. we show that the power law size distribution must hold down to at least 0.03 micron such that the total differential number density is dominated by the smallest sub-micron sized grains. The total dust number density in Enceladus' plume is of the order of l0(exp 2) cm(exp -3) reducing to 1 cm(exp -3) in the E- ring. The dust density for micrometer and larger sized grains is estimated to be about 10(exp -4) cm(exp -3) in the plume while it is about 10(exp -6) - 10(exp -7) cm(exp -3) in the E-ring. Dust charge for micron sized grains is estimated to be about eight thousand electron charges reducing to below one hundred electron charges for 0.03 micron sized grains. The effective dusty plasma Debye length is estimated and compared with intergrain distance as well as the electron Debye length. The maximum dust charging time of 1.4 h is found for 0.03 11mmicron sized grains just 1 min before the closest approach. The charging time decreases substantially in the plume where it is only a fraction of a second for 1 micron sized grains, 1 s for 0.l micron sized grains and about 10 s for 0.03 micron sized grains.

Shafiq, Muhammad↗

Observation of a highly conductive warm dense state of water with ultrafast pump–probe free-electron-laser measurements

The electrical conductivity of water under extreme temperatures and densities plays a central role in modeling planetary magnetic fields. Experimental data are vital to test theories of high-energy-density water and assess the possible development and presence of extraterrestrial life. These states are also important in biology and chemistry studies when specimens in water are confined and excited using ultrafast optical or free-electron lasers (FELs). Here we utilize femtosecond optical lasers to measure the transient reflection and transmission of ultrathin water sheet samples uniformly heated by a 13.6 nm FEL approaching a highly conducting state at electron temperatures exceeding 20 000 K. The experiment probes the trajectory of water through the high-energy-density phase space and provides insights into changes in the index of refraction, charge carrier densities, and AC electrical conductivity at optical frequencies. At excitation energy densities exceeding 10 MJ/kg, the index of refraction falls to n = 0.7, and the thermally excited free-carrier density reaches ne = 5 × 1027 m−3, which is over an order of magnitude higher than that of the electron carriers produced by direct photoionization. Significant specular reflection is observed owing to critical electron density shielding of electromagnetic waves. The measured optical conductivity reaches 2 × 104 S/m, a value that is one to two orders of magnitude lower than those of simple metals in a liquid state. At electron temperatures below 15 000 K, the experimental results agree well with the theoretical calculations using density-functional theory/molecular-dynamics simulations. With increasing temperature, the electron density increases and the system approaches a Fermi distribution. In this regime, the conductivities agree better with predictions from the Ziman theory of liquid metals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlated Double-Electron Additions at the Edge of a Two-Dimensional Electronic System

We create laterally large and low-disorder GaAs quantum-well-based quantum dots that act as small two-dimensional electron systems. We monitor tunneling of single electrons to the dots by means of capacitance measurements and identify single-electron capacitance peaks in the addition spectrum from occupancies of one up to thousands of electrons. The data show two remarkable phenomena in the Landau level filling factor range ν = 2 to ν = 5 in selective probing of the edge states of the dot: (i) Coulomb blockade peaks arise from the entrance of two electrons rather than one; (ii) at and near ν = 5/2 and at fixed gate voltage, these double-height peaks appear uniformly in a magnetic field with a flux periodicity of h/2e, but they group into pairs at other filling factors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron attachment line shapes, cross sections, and rate constants at ultralow energies in CF3SO3H, (CF3SO2)2O, and CF3I

Electron attachment cross sections are reported in the energy range 0-160 meV, and at resolutions of 6.0-6.5 meV (FWHM) for the molecules CF3SO3H (triflic acid), (CF3SO2)2O (triflic anhydride), and CF3I (methyl iodide). Use is made of the Kr photoionization method. Attachment line shapes are deconvoluted from the spectral slit (electron energy) function, and are converted to cross sections by normalization to thermal attachment rate constants at 300 K. Rate constants as a function of mean electron energy are calculated from the cross sections using a Maxwellian electron energy distribution function. Present data are compared with flowing-afterglow, Langmuir-probe results in triflic acid and anhydride, and with high-Rydberg ionization results in CF3I.

Alajajian, S. H.↗

Indirect Calibration In Electron-Probe Microanalysis

Technique for indirect calibration in electron-probe microanalysis reduces number of measurements needed without significantly degrading precision of measurement data. Advantageous when many analyses must be performed; for example, determining varying chemical composition at many positions across specimen of multicomponent alloy. Time spent acquiring data reduced considerably.

Terepka, F. M.↗

Observations of the nightside Venus ionosphere: Final encounter of the Pioneer Venus Orbiter Ion Mass Spectrometer

During the last orbital sequences of the Pioneer-Venus spacecraft prior to final encounter and atmospheric entry, data were obtained by the Orbiter Ion Mass Spectrometer (OIMS) at the lowest periapsis altitudes of the mission. These data verified OIMS observations of the nightside ionospheric peak reported earlier in the mission, and revealed additional details related to composition, energetics and maintenance of the nightside ionosphere. OIMS observations of the ion peak during the final encounter sequence are compared with radio occultation data and OIMS peak observations obtained earlier. OIMS ion density and Orbiter Electron Temperature Probe (OETP) electron density are found to correlate near the peak. Coupling of mass channels 30 and 32 during nightside passes is observed and its interpretation considered. Changes in high altitude composition of the nightside ionosphere, especially the relative changes in O(+) and H(+), are described.

Cloutier, P. A.↗

Observations of the Nightside Venus Ionosphere: Final Encounter of the Pioneer Venus Orbiter Ion Mass Spectrometer

During the last orbital sequences of the Pioneer Venus spacecraft prior to final encounter and atmospheric entry, data were obtained by the Orbiter Ion Mass Spectrometer (OIMS) at the lowest periapsis altitudes of the mission. These data verified OIMS observations of the nightside ionospheric peak reported-earlier in the mission, and revealed additional details related to composition, energetics and maintenance of the nightside ionosphere. OIMS observations of the ion peak during the final encounter sequence are compared with radio occultation data and OIMS peak observations obtained earlier. OIMS ion density and Orbiter Electron Temperature Probe (OETP) electron density are found to correlate near the peak. Coupling of mass channels 30 and 32 during nightside passes is observed and its interpretation considered. Changes in high altitude composition of the nightside ionosphere, especially the relative changes in O(+) and H(+), are described.

Cloutier, P. A.↗

Discharge Chamber Plasma Structure of a 30-cm NSTAR-Type Ion Engine

Single Langmuir probe measurements are presented over a two-dimensional array of locations in the near Discharge Cathode Assembly (DCA) region of a 30-cm diameter ring cusp ion thruster over a range of thruster operating conditions encompassing the high-power half of the NASA throttling table. The Langmuir probe data were analyzed with two separate methods. All data were analyzed initially assuming an electron population consisting of Maxwellian electrons only. The on-axis data were then analyzed assuming both Maxwellian and primary electrons. Discharge plasma data taken with beam extraction exhibit a broadening of the higher electron temperature plume boundary compared to similar discharge conditions without beam extraction. The opposite effect is evident with the electron/ion number density as the data without began, extraction appears to be more collimated than the corresponding data with beam extraction. Primary electron energy and number densities are presented for one operating condition giving an order of magnitude of their value and the error associated with this calculation.

Herman, Daniel A.↗

Short Haul Civil Tiltrotor Contingency Power System Preliminary Design

Single Langmuir probe measurements are presented over a two-dimensional array of locations in the near Discharge Cathode Assembly (DCA) region of a 30-cm diameter ring cusp ion thruster over a range of thruster operating conditions encompassing the high-power half of the NASA throttling table. The Langmuir probe data were analyzed with two separate methods. All data were analyzed initially assuming an electron population consisting of Maxwellian electrons only. The on-axis data were then analyzed assuming both Maxwellian and primary electrons. Discharge plasma data taken with beam extraction exhibit a broadening of the higher electron temperature plume boundary compared to similar discharge conditions without beam extraction. The opposite effect is evident with the electron/ion number density as the data without began, extraction appears to be more collimated than the corresponding data with beam extraction. Primary electron energy and number densities are presented for one operating condition giving an order of magnitude of their value and the error associated with this calculation.

Eames, David J. H.↗