Search NASA⌕ Search

SEARCH · Search NASA

Results for “emission tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Multilayer Chitin–Chitosan–Cellulose Barrier Coatings on Poly(ethylene terephthalate)

Currently, effective barrier properties over a wide range of humidity are achieved by layering multiple plastics, resulting in structures that are nearly impossible to recycle through current systems. There is strong interest in developing barriers that are recyclable, biodegradable, or compostable. Chitin and cellulose nanomaterials are promising alternatives because of their high crystallinity, renewable sourcing, strong electrostatic interactions, and potential for biodegradation or composting. In this paper, we explore the potential to create multilayer materials with effective oxygen and water vapor barrier properties at elevated humidity by combining recyclable poly(ethylene terephthalate) (PET) films with single-layer and bilayer coatings of chitin nanowhiskers (ChNWs), chitosan (CS), and cellulose nanocrystals (CNCs). The addition of CS to the ChNW suspension improved the gas barrier properties of ChNW coatings, likely by filling voids, and short ChNWs (SChNW, 114 nm) performed better than long ChNWs (LChNW, 230 nm). At the optimal mass ratio of 1:1 SChNW/CS, the oxygen permeability (OP) of SChNW/CS-coated PET films was 5.1 cm 3 μm m –2 day –1 kPa –1 versus 15.9 cm 3 μm m –2 day –1 kPa –1 for neat PET. To take advantage of electrostatic attraction and hydrogen bonding, CNC was first coated on the PET, followed by coating with ChNW/CS, resulting in an OP as low as 3.6 cm 3 μm m –2 day –1 kPa –1 at 50% relative humidity (RH), and 6.4 cm 3 μm m –2 day –1 kPa –1 at 80% RH. Furthermore, after thermal treatment (120 °C, 2.5 h), the OP dropped to 2.2 cm 3 μm m –2 day –1 kPa –1 (50% RH) and 4.8 cm 3 μm m –2 day –1 kPa –1 (80% RH). The ChNW/CS and CNC coating can be efficiently removed with alkali treatment enabling possible recycling of the coated PET films.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production and Purification of Terbium-155 Using Natural Gadolinium Targets

Terbium-155 (t 1/2 = 5.32 days) is one of four medically relevant radioisotopes of terbium. It is of interest to the field as a suitable diagnostic counterpart for therapeutic radiolanthanides, as its decay scheme includes γ-rays that are suitable for single photon emission computed tomography (SPECT) imaging. Additionally, 155 Tb has an Auger electron (AE) yield that is viable for AE therapy. There are several direct and indirect production routes that can produce 155 Tb. Two possible direct routes include proton irradiation on gadolinium targets via 155 Gd(p,n) 155 Tb and 156 Gd(p,2n) 155 Tb. The 155 Gd(p,n) 155 Tb reaction is accessible at incident proton beam energies of ∼10 MeV, whereas the 156 Gd(p,2n) 155 Tb nuclear reaction requires ∼18 MeV. This study aims to investigate the production of 155 Tb from natGd through the nat Gd(p,x) nuclear reaction, wherein both (p,n) and (p,2n) reactions were leveraged, and the purification using a three-column ion chromatography method. Using this system, recoveries of radioterbium of up to 97% were achieved in addition to high recoveries of the Gd target material, illustrating the suitability of this technique for enriched targets.

36 MATERIALS SCIENCE↗

Diagnostic, Prognostic, and Therapeutic Use of Radiopharmaceuticals in the Context of SARS-CoV-2

The coronavirus disease 2019 (COVID-19) outbreak has devastated the healthcare systems and economies of over 200 countries in just a few months. The etiological agent of COVID-19, SARS-CoV-2, is a highly contagious virus that can be transmitted by asymptomatic and symptomatic carriers alike. While in vitro testing techniques have allowed for population-wide screening, prognostic tools are required to assess the disease severity and therapeutic response, contributing to improve the patient clinical outcomes. Moreover, no specific antiviral against COVID-19 exists at the time of publication, severely limiting treatment against the infection. Hence, there is an urgent clinical need for innovative therapeutic strategies that may contribute to manage the COVID-19 outbreak and prevent future pandemics. In this work, we critically examine recent diagnostic, prognostic, and therapeutic advancements for COVID-19 in the field of radiopharmaceuticals. First, we summarize the gold standard techniques used to diagnose COVID-19, including in vitro assays and imaging techniques, and then discuss how radionuclide-based nuclear imaging provides complementary information for prognosis and treatment management of infected patients. Second, we introduce new emerging types of radiotherapies that employ radioimmunoconjugates, which have shown selective cytotoxic response in oncological studies, and critically analyze how these compounds could be used as therapeutic agents against SARS-CoV-2. Finally, this Perspective further discusses the emerging applications of radionuclides to study the behavior of pulmonary SARS-CoV-2 aerosol particles.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Production and purification of 43Sc and 47Sc from enriched [46Ti]TiO2 and [50Ti]TiO2 targets

Abstract The radioscandium isotopes, 43 Sc and 47 Sc, compose a promising elementally matched theranostic pair that can be used for the development of imaging and therapeutic radiopharmaceuticals with identical structures. This study aimed to investigate the production of high radionuclidic purity 43 Sc from enriched [ 46 Ti]TiO 2 targets and 47 Sc from enriched [ 50 Ti]TiO 2 targets and establish a target recycling technique. Enriched [ 46 Ti]TiO 2 targets were irradiated with 18 MeV protons, and enriched [ 50 Ti]TiO 2 targets were bombarded with 24 MeV protons. 43 Sc and 47 Sc were purified using ion chromatography attaining recovery yields of 91.7 ± 7.4% and 89.9 ± 3.9%, respectively. The average radionuclidic purity for 43 Sc was 98.8 ± 0.3% and for 47 Sc 91.5 ± 0.6%, while the average recovery of enriched titanium target material was 96 ± 4.0%. The highest apparent molar activity for [ 43 Sc]Sc-DOTA was 23.2 GBq/µmol and 3.39 GBq/µmol for [ 47 Sc]Sc-DOTA. This work demonstrates the feasibility of using enriched recycled [ 46 Ti]TiO 2 and [ 50 Ti]TiO 2 targets to produce high purity 43 Sc and 47 Sc as an elementally matched theranostic isotope pair.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Relevance of biomarkers across different neurodegenerative diseases

The panel of fluid- and imaging-based biomarkers available for neurodegenerative disease research is growing and has the potential to close important gaps in research and the clinic. With this growth and increasing use, appropriate implementation and interpretation are paramount. Various biomarkers feature nuanced differences in strengths, limitations, and biases that must be considered when investigating disease etiology and clinical utility. For example, neuropathological investigations of Alzheimer’s disease pathogenesis can fall in disagreement with conclusions reached by biomarker-based investigations. Considering the varied strengths, limitations, and biases of different research methodologies and approaches may help harmonize disciplines within the neurodegenerative disease field.

60 APPLIED LIFE SCIENCES↗

Engineering a modular 44 Ti/ 44 Sc generator: eluate evaluation in preclinical models and estimation of human radiation dosimetry

Background: 44 Sc/ 47 Sc is an attractive theranostic pair for targeted in vivo positron emission tomographic (PET) imaging and beta-particle treatment of cancer. The 44 Ti/ 44 Sc generator allows daily onsite production of this diagnostic isotope, which may provide an attractive alternative for PET facilities that lack in-house irradiation capabilities. Early animal and patient studies have demonstrated the utility of 44 Sc. In our current study, we built and evaluated a novel clinical-scale 44 Ti/ 44 Sc generator, explored the pharmacokinetic profiles of 44 ScCl 3 , [ 44 Sc]-citrate and [ 44 Sc]-NODAGA (1,4,7-triazacyclononane,1-glutaric acid-4,7-acetic acid) in naïve mice, and estimated the radiation burden of 44 ScCl 3 in humans. Methods: 44 Ti/ 44 Sc (101.2 MBq) in 6 M HCl solution was utilized to assemble a modular ZR resin containing generator. After assembly, 44 Sc was eluted with 0.05 M HCl for further PET imaging and biodistribution studies in female Swiss Webster mice. Based on the biodistribution data, absorbed doses of 44 / 47 ScCl 3 in human adults were calculated for 18 organs and tissues using the IDAC-Dose software. Results: 44 Ti in 6 M HCl was loaded onto the organic resin generator with a yield of 99.97%. After loading and initial stabilization, 44 ScCl 3 was eluted with 0.05 M HCl in typical yields of 82.9 ± 5.3% (N = 16), which was normalized to the estimated generator capacity. Estimated generator capacity was computed based on elution time interval and the total amount of 44 Ti loaded on the generator. Run in forward and reverse directions, the 44 Sc/ 44 Ti ratio from a primary column was significantly improved from 1038 ± 440 to 3557 ± 680 (Bq/Bq) when a secondary, replaceable, ZR resin cartridge was employed at the flow outlet. In vivo imaging and ex vivo distribution studies of the reversible modular generator for 44 ScCl 3 , [ 44 Sc]-citrate and [ 44 Sc]-NODAGA show that free 44 Sc remained in the circulation significantly longer than the chelated 44 Sc. The dose estimation of 44 ScCl 3 reveals that the radiation burden is 0.146 mSv/MBq for a 70 kg adult male and 0.179 mSv/MBq for a 57 kg adult female. Liver, spleen and heart wall will receive the highest absorbed dose: 0.524, 0.502, and 0.303 mGy/MBq, respectively, for the adult male. Conclusions: A clinical-scale 44 Ti/ 44 Sc generator system with a modular design was developed to supply 44 ScCl 3 in 0.05 M HCl, which is suitable for further radiolabeling and in vivo use. Our data demonstrated that free 44 ScCl 3 remained in the circulation for extended periods, which resulted in approximately 10 times greater radiation burden than stably chelated 44 Sc. Stable 44 Sc/ 47 Sc-complexation will be more favorable for in vivo use and for clinical utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Production of Radiohalogens: Bromine and Astatine for Imaging and Therapy

Over the course of this two year grant, we have developed and optimized new methods for the production of clinical quality 76 Br, 77 Br, and 80m Br at the University of Wisconsin. This includes the synthesis of a novel isotopically enriched cobalt-selenium intermetallic compound, its fabrication into robust cyclotron targets, and the chemical isolation of the resulting bromine radionuclide. Compared with the previous state-of-the-art, these methods demonstrate a six-times larger 76 Br and three-times larger 77 Br production capacity for a 3-hour cyclotron irradiation. Additionally, the cyclotron targets are exceptionally robust to this process, allowing for their reuse for dozens of radiobromine productions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Production of Radioisotopes of Scandium for Imaging and Therapy (Final Report)

This collaborative proposal aims developed techniques for the production of important medical isotopes of scandium; 43Sc, 44Sc, and 47Sc. By leveraging complementary infrastructure available at the three collaborating instructions, we have achieved a robust supply source for these isotopes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Application of Monte Carlo Algorithms to Cardiac Imaging Reconstruction

Monte Carlo algorithms have a growing impact on nuclear medicine reconstruction processes. One ofthe main limitations of myocardial perfusion imaging (MPI) is the effective mitigation of the scattering component,which is particularly challenging in Single Photon Emission Computed Tomography (SPECT). In SPECT,no timing information can be retrieved to locate the primary source photons. Monte Carlo methods allow anevent-by-event simulation of the scattering kinematics, which can be incorporated into a model of the imagingsystem response. This approach was adopted in the late Nineties by several authors, and recently took advantageof the increased computational power made available by high-performance CPUs and GPUs. These recent developmentsenable a fast image reconstruction with improved image quality, compared to deterministic approaches.Deterministic approaches are based on energy-windowing of the detector response, and on the cumulative estimateand subtraction of the scattering component. In this paper, we review the main strategies and algorithms tocorrect the scattering effect in SPECT and focus on Monte Carlo developments, which nowadays allow the threedimensionalreconstruction of SPECT cardiac images in a few seconds.

Pharmacology & Pharmacy↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Production, Purification, and Applications of a Potential Theranostic Pair: Cobalt-55 and Cobalt-58m

The emerging success of [68Ga/177Lu]Ga/Lu-DOTATATE as a theranostic pair has spurred interest in other isotopes as potential theranostic combinations. Here, we review cobalt-55 and cobalt-58m as a potential theranostic pair. Radionuclidically pure cobalt-55 and cobalt-58m have been produced on small cyclotrons with high molar activity. In vitro, DOTATOC labeled with cobalt has shown greater affinity for SSTR2 than DOTATOC labeled with gallium and yttrium. Similarly, [58mCo]Co-DOTATATE has shown improved cell-killing capabilities as compared to DOTATATE labeled with either indium-111 or lutetium-177. Finally, PET imaging with an isotope such as cobalt-55 allows for image acquisition at much later timepoints than gallium, allowing for an increased degree of biological clearance of non-bound radiotracer. We discuss the accelerator targetry and radiochemistry used to produce cobalt-55,58m, emphasizing the implications of these techniques to downstream radiotracers being developed for imaging and therapy.

60 APPLIED LIFE SCIENCES↗

Comparative Uptake Patterns of Radioactive Iodine and [18F]-Fluorodeoxyglucose (FDG) in Metastatic Differentiated Thyroid Cancers

Background: Metastatic differentiated thyroid cancer (DTC) represents a molecularly heterogeneous group of cancers with varying radioactive iodine (RAI) and [ 18 F]-fluorodeoxyglucose (FDG) uptake patterns potentially correlated with the degree of de-differentiation through the so-called “flip-flop” phenomenon. However, it is unknown if RAI and FDG uptake patterns correlate with molecular status or metastatic site. Materials and Methods: A retrospective analysis of metastatic DTC patients (n = 46) with radioactive 131-iodine whole body scan (WBS) and FDG-PET imaging between 2008 and 2022 was performed. The inclusion criteria included accessible FDG-PET and WBS studies within 1 year of each other. Studies were interpreted by two blinded radiologists for iodine or FDG uptake in extrathyroidal sites including lungs, lymph nodes, and bone. Cases were stratified by BRAF V600E mutation status, histology, and a combination of tumor genotype and histology. The data were analyzed by McNemar’s Chi-square test. Results: Lung metastasis FDG uptake was significantly more common than iodine uptake (WBS: 52%, FDG: 84%, p = 0.04), but no significant differences were found for lymph or bone metastases. Lung metastasis FDG uptake was significantly more prevalent in the papillary pattern sub-cohort (WBS: 37%, FDG: 89%, p = 0.02) than the follicular pattern sub-cohort (WBS: 75%, FDG: 75%, p = 1.00). Similarly, BRAF V600E+ tumors with lung metastases also demonstrated a preponderance of FDG uptake (WBS: 29%, FDG: 93%, p = 0.02) than BRAF V600E- tumors (WBS: 83%, FDG: 83%, p = 1.00) with lung metastases. Papillary histology featured higher FDG uptake in lung metastasis (WBS: 39%, FDG: 89%, p = 0.03) compared with follicular histology (WBS: 69%, FDG: 77%, p = 1.00). Patients with papillary pattern disease, BRAF V600E+ mutation, or papillary histology had reduced agreement between both modalities in uptake at all metastatic sites compared with those with follicular pattern disease, BRAF V600E- mutation, or follicular histology. Low agreement in lymph node uptake was observed in all patients irrespective of molecular status or histology. Conclusions: The pattern of FDG-PET and radioiodine uptake is dependent on molecular status and metastatic site, with those with papillary histology or BRAF V600E+ mutation featuring increased FDG uptake in distant metastasis. Further study with an expanded cohort may identify which patients may benefit from specific imaging modalities to recognize and surveil metastases.

60 APPLIED LIFE SCIENCES↗

Design and Validation of a Gammaray Scanning System for Measuring Irradiated Nuclear Fuel

A prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) for engineering flow measurements

Increasingly, fully 3D experimental measurements of flow in complex engineering geometries are required to validate computational fluid dynamics models that support and inform reactor design and licensing. One barrier to such measurements is the complexity of typical reactor components and subsequent lack of optical access in these systems. To overcome this, the deployment of coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) is explored for flow measurement in reactor thermal hydraulic components and model (scaled) systems. Through this methodology, fully 3D flow information (via PEPT) and detailed internal geometry (via CT) are captured in opaque systems such as pipes, rod bundles, packed beds, etc. The reconstructed flow field and geometry can then be overlain to reveal detailed flow features around internal structures within a given test section. This is enabled through the use of a combined preclinical PET/CT scanner with overlapping PET and CT fields of view. Such measurements are useful for characterizing flow inside such intricate nuclear thermal hydraulic components as core geometries and heat exchangers, among others, and providing valuable 3D validation data for CFD models. In this work, basic tests of this 3D flow/geometry mapping are presented, and the implications of such measurements are discussed. Further, preliminary measurements are made with both point sources and flow in a simple pipe flow geometry to evaluate the capabilities of this technique. PEPT and CT features are coregistered with up to 0.1 mm precision, and pipe flow mean velocity and Reynolds stresses are reconstructed with similar accuracy to previous PEPT demonstrations. The utility of PEPT/CT is shown herein, and suggestions for future measurements are made.

3D flow measurement↗

Enhanced Tooth Structure Via Silver Microwires Following Treatment with 38 Percent Silver Diamine Fluoride.

The American Academy of Pediatric Dentistry guidelines recommend treatment of primary teeth with 38 percent silver diamine fluoride (SDF) as a noninvasive option to arrest active dental caries lesions. A significant outcome of SDF treatment are lesions that clinically harden and become more resistant to further decay. Many practicing dentists believe that this increased hardening is due to the reaction of silver and fluoride with carious dentin. The purpose of this study was to focus on the structural and chemical effects of silver diamine fluoride treatment on the native tooth. In SDF-treated cavitated dentin lesions in teeth subsequently extracted for orthodontic reasons, the authors observed continuous, filamentous silver densities formed in situ from 50 to 2,100 μm in length and 0.25 to 7.0 μm in diameter using high-resolution synchrotron X-ray microcomputer tomography and field emission scanning electron microscopy. These "microwires" fill voids in the lesion caused by disease and permeate through surrounding dentinal tubules. Spectroscopy confirmed that the chemical composition of the observed microwires is predominantly silver. These observations suggest mechanistic explanations for the structural reinforcement of carious dentin in addition to remineralization. It is hypothesized that silver diamine fluoride may achieve its antimicrobial functions by biochemical interactions and through its inherent ability to integrate into the native tooth structure.

60 APPLIED LIFE SCIENCES↗

Enhanced Tooth Structure Via Silver Microwires Following Treatment with 38 Percent Silver Diamine Fluoride.

Purpose: American Academy of Pediatric Dentistry guidelines recommend treatment of primary teeth with 38 percent silver diamine fluoride (SDF) as a noninvasive option to arrest active dental caries lesions. A significant outcome of SDF treatment are lesions that clinically harden and become more resistant to further decay. Many practicing dentists believe that this increased hardening is due to the reaction of silver and fluoride with carious dentin. The purpose of this study was to focus on the structural and chemical effects of silver diamine fluoride treatment on the native tooth. Methods: In SDF-treated cavitated dentin lesions in teeth subsequently extracted for orthodontic reasons, the authors observed continuous, filamentous silver densities formed in situ from 50 to 2,100 μm in length and 0.25 to 7.0 μm in diameter using high-resolution synchrotron X-ray microcomputer tomography and field emission scanning electron microscopy. These microwires fill voids in the lesion caused by disease and permeate through surrounding dentinal tubules. Results: Spectroscopy confirmed that the chemical composition of the observed microwires is predominantly silver. Conclusions: These observations suggest mechanistic explanations for the structural reinforcement of carious dentin in addition to remineralization. It is hypothesized that silver diamine fluoride may achieve its antimicrobial functions by biochemical interactions and through its inherent ability to integrate into the native tooth structure.

60 APPLIED LIFE SCIENCES↗