Search NASA⌕ Search

SEARCH · Search NASA

Results for “end of discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Effect of KOH Concentration and Anions on the Performance of a Ni-H2 Battery Positive Plate

The capacity and voltage behavior of electrochemically impregnated sintered nickel positive plates was examined by galvanostatic charging and discharging in a flooded electrolyte cell. Three different concentrations of potassium hydroxide (KOH) (40, 31, and 26 percent) and 31 percent KOH containing dissolved nitrate, sulfate, or silicate were investigated. The end-of-charge voltage at C/10 charge and at 10 degrees C showed the following order: 40 percent KOH greater than 31 percent KOH alone and in the presence of the anions greater than 26 percent KOH. The mid discharge voltage at C/2 discharge was higher in 26 percent KOH, almost the same for 31 percent KOH with and without added contaminants, and much lower for 40 percent KOH. The plate capacity was marginally affected by cycling in all cases except for 40 percent KOH, where the capacity declined after 1,000 cycles at 80 percent depth of discharge (DOD). At the end of cycling, all the plates tested experienced a weight loss, except in the case of 31 percent KOH, as a result of active material extrusion. Cyclic voltammetry of miniature electrodes in 31 percent KOH showed that the cathodic peak potentials are less polarized in the presence and absence of silicate at -5 degrees C compared to 25 degrees C indicating a slightly higher voltage during discharge in a Ni-H2 battery. Futhermore, the features of the current-potential profile were practically unchanged in the presence of silicate.

Vaidyanathan, Hari↗

Battery charge control: Which approach is best?

The question of the best approach for battery charge control is addressed from two points of view: from the battery point-of-view; and from the spacecraft/mission point-of-view. In terms of performance, more aggressive charging can result in higher discharge voltage and capacity; however, aggressive charging usually implies more overcharge at higher rates and a concomitant higher end of charge temperature (higher stress, shorter life). In terms of life, benign charging can result in lower discharge voltage and capacity (poorer performance). Additionally, benign, or low stress charging, usually implies less overcharge at lower rates with lower end of charge temperature (lower stress, longer life). A discussion of these topics is presented in viewgraph form.

Lurie, Charles↗

Estimate long-term impact on battery degradation by considering electric vehicle real-world end-use factors

Many estimates of battery capacity degradation are based on accelerated lab tests that involve charge-discharge cycles or rely on data or electrochemical modeling. These methods are reasonable for technology benchmarking but rarely consider real-world end-use factors. To address this issue, this study develops the Battery Run-down under Electric Vehicle Operation (BREVO) model. It links the driver's travel pattern to physics-based battery degradation and powertrain energy consumption models. The model simulates the impacts of charging behavior, charging rate, driving patterns, and multiple energy management modules on battery capacity degradation. It finds that, over a 10-year timespan, firstly, for a random driver situated in the New England area, daily direct-current fast charging (60 kW) could lead to up to 22% less battery capacity when compared to daily Level-1 charging (1.8 kW). Second, the battery thermal management system can delay battery degradation by approximately 0.5% in the New England area. Third, warmer ambient temperatures enhance BEV battery usage. The model indicates that the battery capacity in the Los Angeles area is 6% higher than that in the New England area. The BREVO model provides crucial information for consumers and BEV manufacturers on range anxiety, BEV battery design, and decision support of battery warranty.

25 ENERGY STORAGE↗

Megafans as Hydrous Environments

The mesoscale sedimentary environment known as the megafan, is a low-angle, partial cone of fluvial sediment generated where a river enters an unconfined basin where it begins the process of avulsing over wide areas. In shifting to different positions, the river lays down a partial cone of sediment and establishes a characteristic radial pattern of paleo courses. The apparent paucity of sedimentary bodies obviously tied to martian outflow channels may also relate to the difficulty of recognition due to their sheer size and featurelessness. However, the existence of megafans on Mars is being examined now that their ubiquity and characteristics on Earth are better understood. Accordingly we suggest two likely candidates on Mars: Maja Valles fluvial cone and Amazonis Planitia fluvial sedimentary bodies. Two cryptic examples from Amazonis Planitia may be important for understanding subsurface hydrous accumulation. For at least some of its history, discharges from Mangala Valles likely resulted in megafans. Distances from the end of Mangala Valles to the northern (low) margin of the planitia are very large, a fact that has suggested that fluvial emplacement was unlikely. However, the megafan model shows that long megafan radii are indeed feasible. It has been suggested further that discharge from Labou Vallis (8.5S 154.5W) must have led to fluvial sedimentation in the planitia. We suggest that during locally non-lacustrine/ocean phases, this sedimentation would have occurred in the form of megafans. However, the megafan model shows that long megafan radii are indeed feasible. It has been suggested further that discharge from Labou Vallis (8.5S 154.5W) must have led to fluvial sedimentation in the planitia. We suggest that during locally non-lacustrine/ocean phases, this sedimentation would have occurred in the form of megafans. Megafans emanating from Marte, Mangala and Labou valles have probably contributed to hydrous near-subsurface environments--in their distal reaches, i.e. along the northern, eastern and southeastern margins of Amazonis Planitia at various times. Following a new terrestrial analog, we conclude groundwater has at times accumulated preferentially beneath distal slopes of the Maja Valles feature, and along the northern, eastern and southeastern margins of Amazonis Planitia.

Wilkinson, M. Justin↗

Transient cryogenic liquid discharge in normal and micro-gravity

Transient discharge of liquid cryogens from partially filled tanks under microgravity is considered. The discharge is made to a low-pressure site through a straight tube. The ultimate objective of the study is to predict the transient mass flow rate. In addition, the pressure history in the tank is of interest, since the pressure falls below the triple point toward the end of the dump, causing solidification in the tank and/or the discharge line. As first steps, experiments have been performed in normal gravity and attempts are made to predict the transient rate and pressure history under this condition. Experiments are performed with liquid nitrogen dumped to sites with pressures below the triple point. Homogeneous equilibrium and nonequilibrium two-phase critical flow models are compared to the experimental results. Equilibrium and nonequilibrium tank pressure history models are also compared to experimental data.

Purwin, T. P.↗

Importance of mitral valve repair associated with left ventricular reconstruction for patients with ischemic cardiomyopathy: a real-time three-dimensional echocardiographic study

BACKGROUND: Left ventricular (LV) reconstruction surgery leads to early improvement in LV function in ischemic cardiomyopathy (ICM) patients. This study was designed to evaluate the impact of mitral valve (MV) repair associated with LV reconstruction on LV function 1-year after surgery in ICM patients assessed by real-time 3-dimensional echocardiography (3DE). METHODS AND RESULTS: Sixty ICM patients who underwent the combination surgery (LV reconstruction in 60, MV repair in 30, and revascularization in 52 patients) were studied. Real-time 3DE was performed and LV volumes were obtained at baseline, discharge, 6-month and >or=12-month follow-up. Reduction in end-diastolic volumes (EDV) by 29% and in end-systolic volumes by 38% were demonstrated immediately after surgery and remained at subsequent follow-up (P<0.0001). The LV ejection fraction significantly increased by about 10% at discharge and was maintained >or=12-month (P<0.0001). Although the LV volumes were significantly larger in patients with MV repair before surgery (EDV, 235+/-87 mL versus 193+/-67 mL, P<0.05), they were similar to LV volumes of the patients without MV repair at subsequent follow-ups. However, the EDV increased from 139+/-24 mL to 227+/-79 mL (P<0.01) in 7 patients with recurrent mitral regurgitation (MR). Improvement in New York Heart Association functional class occurred in 81% patients during late follow-up. CONCLUSIONS: Real-time 3DE demonstrates that LV reconstruction provides significant reduction in LV volumes and improvement in LV function which is sustained throughout the 1-year follow-up with 84% cardiac event free survival. If successful, MV repair may prevent LV redilation, while recurrent MR is associated with increased LV volumes.

Clinical Trial↗

Polydiketoenamines for a Circular Plastics Economy

The mismanagement and leakage of plastic waste into the environment are failures of modern society. Once in the environment, plastic waste degrades into microplastics on a time scale dependent on the resin chemistry and the associated biotic or abiotic process. Here, the high surface area of microplastics results in the contamination of ecosystems through the leaching of toxic chemicals compounded with plastics during manufacturing. In addition, the small size of microplastics increases the likelihood that they will be inhaled or ingested, which has led to the bioaccumulation of microplastics with documented harm. Furthermore, microplastics are more readily aerosolized and distributed by weather systems to areas remote from locations where plastic waste has been mismanaged. Consequently, the carbon cycle must now account for plastic waste discharge, degradation, and dispersal in the environment after the end of useful life on a global scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fuel Assembly and Irradiation Parametric Study for Extended-Enrichment and High-Burnup Light-Water Reactor Spent Nuclear Fuel in Dry Storage Casks and Transportation Packages

There is an increased interest in operating commercial light-water reactors (LWRs) in the United States with improved economics that would result from longer fuel cycle lengths, fewer and shorter refueling outages, and fewer fuel assemblies requiring storage at the back end of the fuel cycle. To support this, fuel discharge burnups, as well as initial 235 U enrichments, must be higher than those used in current commercial LWRs. The typical upper limit considered for assembly average burnup in this report is 75 gigawatt-days (GWd) per metric ton of uranium (MTU), as opposed to the current typical upper bound of approximately 62 GWd/MTU. The upper limit considered for initial 235 U enrichment is 8 weight percent (8 wt %), as opposed to the current regulatory limit of 5 wt %. The enrichment range from 5 to 8 wt % is referred to in this report as extended enrichment . To investigate the effect of high burnup and extended enrichment conditions on dose rates and burnup credit for dry storage casks and transportation packages, a fuel assembly and irradiation parametric study was performed. The conclusions from this study will assist U.S. Nuclear Regulatory Commission staff in reviewing applications for dry storage casks and transportation packages that contain high-burnup and extended enrichment fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Centrifugal-reciprocating compressor

A centrifugal compressor is described which includes at least one pair of cylinders arranged in coaxial alignment and supported for angular displacement about a common axis of rotation normally disecting a common longitudinal axis of symmetry for the cylinders. The cylinders are characterized by ported closures located at the mutually remote ends thereof through which the cylinders are charged and discharged, and a pair of piston heads seated within the cylinders and supported for floating displacement in compressive strokes in response to unidirectional angular displacement imparted to the cylinders.

Higa, W. H.↗

Hydrogen no-vent fill testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

Moran, Matthew E.↗

Hydrogen no-vent testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

Moran, Matthew E.↗

Air ion exposure system for plants

A system was developed for subjecting plants to elevated air ion levels. This system consisted of a rectangular Plexiglas chamber lined with a Faraday cage. Air ions were generated by corona discharge from frayed stainless steel fibers placed at one end of the chamber. This source was capable of producing varying levels of either positive or negative air ions. During plant exposures, environmental conditions were controlled by operating the unit in a growth chamber.

NASA Discipline Number 61-10↗

Air turbo-ramjet engine

A jet engine designed to power a supersonic airplane throughout a range of speeds from subsonic to high supersonic includes a housing which bounds an internal passage having in succession a fixed-area inlet section, a diverging passage section, a mixing section, a combustion section, and an outlet section. A fan rotor rotates in the inlet section and includes a plurality of rotor blade members. The housing includes a main body and at least one flap which is movable between one end position in which it externally bounds a portion of the diverging passage section and another end position in which it externally delimits a diverging discharge passage connecting the diverging passage section with the exterior of the housing. The cross-sectional area of the outlet section is adjustable. The rotor is driven in rotation by a fuel/oxygen powered turbine the outlet of which communicates with the mixing section, but the driving action of the turbine is discontinued at actual supersonic velocities exceeding a predetermined supersonic velocity. The pitch of at least one element of each of the rotor blade members is adjustable.

Kepler, Charles E.↗

Electrostatic Discharge Testing of Carbon Composite Solar Array Panels for NASA's Planned Europa Mission to Jupiter

The next planned NASA mission to visit Jupiter is known as the Europa Mission. The objective of this mission concept is to enter orbit around Jupiter in order to conduct multiple close flybys of the icy moon Europa. After careful trade studies, the mission designers have selected solar arrays as the baseline power system for the proposed mission rather than more traditional radioisotope thermoelectric generators. In order to examine the risk of using solar arrays, a series of tests were devised to determine the response of a typical solar array coupon to energetic electrons. Test coupons were fabricated and exposed to electrons ranging from 10 keV to 100 keV, at 1 nA/cm2, while being held at both room and cryogenic temperatures and exposed to end of mission radiation levels. While under electron bombardment, electrical discharges were observed and recorded with the majority of discharges occurring with electron energies of 25 keV. The largest effects on discharge size and rate were the decrease in temperature and the reduction of dielectric material on the sample surface. These tests indicate that solar array panels could be used by the planned Europa Mission in the Jovian environment, but that electrostatic discharges could be expected on the carbon composite solar arrays.

carbon composite↗

Fault Location Using the Natural Frequency of Oscillation of Current Discharge in MTdc Networks

This paper discusses a novel offline-fault location approach using single ended measurements. The natural dissipation of the circuit parameters are considered for fault location. A relationship between the damped natural frequency of oscillation of the transmission line current and fault location is established. The hybrid dc circuit breaker (dcCB) interrupts the fault current, whereby the transmission line current attenuates under the absence of any driving voltage source. The line capacitance discharges into the fault at a specific frequency of oscillation and rate of attenuation. Utilizing this information, the fault location in a multi-terminal direct current (MTdc) network can be obtained. A three terminal radial model of a MTdc is used for performance evaluation of the proposed method using Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

42 ENGINEERING↗

Dynamic cycling enhances battery lifetime

Laboratory aging campaigns benchmark and elucidate the complex degradation behavior of lithium-ion batteries, and are critical not only for developing new battery chemistries and cell designs but also for engineering reliable battery management systems. Critically, these laboratory experiments aim to quantify and capture realistic aging mechanisms. In this study, we systematically compare dynamic discharge profiles representative of electric vehicle driving to the well-accepted constant-current profiles. Surprisingly, we discovered that dynamic discharge enhances lifetime substantially compared to constant current discharge. Specifically, for the same average current and voltage window, varying the dynamic discharge profile leads to an increase of up to 38 % in equivalent full cycles at end-of-life. Explainable machine learning reveals the importance of low-frequency current pulses as well as time-induced aging under these realistic discharge conditions. Our work quantifies the importance of evaluating new battery chemistries and designs with realistic load profiles, and highlights the opportunities to revisit our understanding of aging mechanisms at the chemistry, materials, and cell levels.

25 ENERGY STORAGE↗

Fabrication and testing of negative limited sealed nickel-cadmium cells

A number of 20 Ah and 3 Ah negative limited nickel-cadmium cells were fabricated and assembled in hermetically sealed stainless steel containers. The cells exhibit a large voltage rise signal, in excess of 250 mA, at the end of each charge period. They also exhibit lower self discharge rates than conventional sealed nickel-cadmium cells and do not require overcharge. The cells are capable of operating at charge and discharge rates up to 5C and can deliver at least 1000 cycles on a 30 minute regime at 25% DOD. A small amount of gassing occurs, but is not deemed critical or detrimental in view of the facts that, (1) operating pressures are in the range of 7 to 20 psig and (2) the cells are operated in the flooded condition so therefore contain little internal void volume. The cells were found to exhibit somewhat higher capacity loss rates during cycling than conventional sealed nickel-cadmium batteries.

Gordy, D. J.↗