Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy efficiency measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

ResStock Measure Documentation: Dual Fuel Heat Pump

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Dual Fuel Heat Pump" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation, New Windows, LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility enduse load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Natural Gas Furnace 95% AFUE

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Natural Gas Furnace 95% AFUE" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, and Duct Sealing" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Electric Vehicle Adoption With Level 1 Charging

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Electric Vehicle Adoption With Level 1 Charging" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Electric Vehicle Adoption With Level 2 Charging

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Electric Vehicle Adoption With Level 2 Charging" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing for Zero Energy and Zero Carbon on a Multi-Building Scale Using URBANopt: Preprint

Groundbreaking efforts are necessary to mitigate contributors increasing impacts of climate change. In parallel to inventing pioneering clean energy technologies it is even more fundamental to rethink designing energy systems within a singular facility and collectively to function as a district. Facilities should not be continuously passive by just consuming; there is a need to shift to perform more dynamically. Designing for zero energy and zero carbon on a multi-building scale can uncover opportunities for building energy efficiency, decarbonization, demand flexibility, and resiliency that are not accessible at an individual building scale. This approach can be challenging without innovative tools to evaluate the multitude of possibilities. As an investigated result, we highlight the use of a campus-scale energy modeling platform - URBANopt™ - for the expansion of the National Renewable Energy Laboratory's (NREL's) South Table Mountain campus in Golden, Colorado. Programmatic growth included the design of three new all-electric, zero-energy, and zero-carbon, mixed used buildings (a combination of research laboratories and office space). This investigation is critical to NREL reaching net-zero emissions for its operational footprint, which will occur in phases over the next decade. Leveraging URBANopt's capabilities, we evaluate 1) high-performance building energy efficiency and decarbonization measures, 2) 4th generation district heating and cooling (4th GDHC) systems, 3) optimized onsite generation and energy storage assets that meet zero-energy and zero-carbon targets at minimum life-cycle costs, and 4) cost-optimal distributed energy technology mixes, dispatch strategies, and associated capacities that increase resiliency to grid outages. This work demonstrates the use and capabilities of URBANopt through a real-world case study on a multi-building scale.

community energy model↗

ResStock Measure Documentation: Electric Vehicle Adoption With Level 2 Charging and Demand Flexibility

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Electric Vehicle Adoption With Level 2 Charging and Demand Flexibility" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Reference Space Heating and Air Conditioning Upgrade Circa 2025

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Reference Space Heating and Air Conditioning Upgrade Circa 2025" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Propane Furnace 95% AFUE and Fuel Oil Furnace 88% AFUE

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Propane Fuel 95% AFUE and Fuel Oil Furnace 88% AFUE" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where β-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure β-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. In this work we discuss how the first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comprehensive Approach to Measure the Efficiency of Freight Transport: Freight Mobility Energy Productivity (F-MEP) Metric

Freight travel accounts for a major share of the energy consumed in the transportation sector in any country, and the United States is no exception. Understanding and modeling freight movement is critical, particularly in the context of capturing the impact of emerging technologies on freight travel and its externalities. The domain of freight modeling and forecasting is gaining pace in the recent years, but advancement in comprehensive freight performance metrics is still lagging. Conventional freight performance metrics such as truck-miles, ton-miles, or value-miles are unidimensional and aggregated in nature, making them unsuitable to accurately capture the impact of emerging transportation trends on the performance of freight systems. Addressing this research need, this paper presents the 'Freight Mobility Energy Productivity' metric to quantify freight performance of current as well as future freight systems, accounting for various costs associated with freight transport. The proposed metric was implemented using data from the Freight Analysis Framework along with other published sources, which shows intuitive results in quantifying freight performance. Further, a scenario analysis exercise was conducted to test the capability of the metric in tracking improvements in system-level freight efficiency as a result of vehicle powertrain technology improvement. Results of the scenario analysis reinforce confidence that the proposed metric can be used as a decision support tool in assessing the efficiency of existing as well as future freight trends and technologies.

25 ENERGY STORAGE↗