Conservation: Toward firmer ground

The following aspects of energy conservation were discussed: conservation history and goals, conservation modes, conservation accounting-criteria, and a method to overcome obstacles. The conservation modes tested fall into one of the following categories: reduced energy consumption, increased efficiency of energy utilization, or substitution of one or more forms of energy for another which is in shorter supply or in some sense thought to be of more value. The conservation accounting criteria include net energy reduction, economic, and technical criteria. A method to overcome obstacles includes (approaches such as: direct personal impact (life style, income, security, aspiration), an element of crisis, large scale involvement of environmental, safety, and health issues, connections to big government, big business, big politics, involvement of known and speculative science and technology, appeal to moral and ethical standards, the transient nature of opportunities to correct the system.

Source record↗

A theoretical interpretation of Forbush decreases

An analysis is presented of the intensity variations of relativistic cosmic rays, at 1 AU, which are associated with the passage of a flare shock wave. The magnitude and time profile obtained is similar to that observed in flare-induced Forbush decreases, and the principal cause of the energy reduction is an increase in adiabatic cooling of the arriving particles due to prolonged containment behind the compressed field of the flare shock wave. The large decreases calculated for the smaller diffusion coefficients are inconsistent with observation, implying larger mean free paths than those traditionally assumed at these rigidities. The method presented may be used to study intensity variations associated with other large-scale structures of the interplanetary field, such as corotating interaction regions.

Gall, R.↗

Development of a nuclear technique for monitoring water levels in pressurized vehicles

A new technique for monitoring water levels in pressurized stainless steel cylinders was developed. It is based on differences in attenuation coefficients of water and air for Cs137 (662 keV) gamma rays. Experimentally observed gamma ray counting rates with and without water in model reservoir cylinder were compared with corresponding calculated values for two different gamma ray detection theshold energies. Calculated values include the effects of multiple scattering and attendant gamma ray energy reductions. The agreement between the measured and calculated values is reasonably good. Computer programs for calculating angular and spectral distributions of scattered radition in various media are included.

Singh, J. J.↗

Air Evaporation closed cycle water recovery technology - Advanced energy saving designs

The Air Evaporation water recovery system is a visible candidate for Space Station application. A four-man Air Evaporation open cycle system has been successfully demonstrated for waste water recovery in manned chamber tests. The design improvements described in this paper greatly enhance the system operation and energy efficiency of the air evaporation process. A state-of-the-art wick feed design which results in reduced logistics requirements is presented. In addition, several design concepts that incorporate regenerative features to minimize the energy input to the system are discussed. These include a recuperative heat exchanger, a heat pump for energy transfer to the air heater, and solar collectors for evaporative heat. The addition of the energy recovery devices will result in an energy reduction of more than 80 percent over the systems used in earlier manned chamber tests.

Morasko, Gwyndolyn↗

Observation of wave refraction at an ice edge by synthetic aperture radar

In this note the refraction of waves at the ice edge is studied by using aircraft synthesis aperture radar (SAR). Penetration of a dominant swell from open ocean into the ice cover was observed by SAR during the Labrador Ice Margin Experiment (LIMEX), conducted on the marginal ice zone (MIZ) off the east coast of Newfoundland, Canada, in March 1987. At an ice edge with a large curvature, the dominant swell component disappeared locally in the SAR imagery. Six subscenes of waves in the MIZ from the SAR image have been processed, revealing total reflection, refraction, and energy reduction of the ocean waves by the ice cover. The observed variations of wave spectra from SAR near the ice edge are consistent with the model prediction of wave refraction at the ice edge due to the change of wave dispersion relation in ice developed by Liu and Mollo-Christensen (1988).

Liu, Antony K.↗

Multiple Scattering Theory for Modeling Sonic Booms in Atmospheric Turbulence

Sonic booms are often modeled using Burgers equations accounting for dominant propagation effects. Scattering effects of turbulence, however, have not been incorporated into such equations, although these effects are ubiquitous in measured sonic booms. This paper formulates the mean scattering effects, including backscattering, using multiple scattering theory and ensemble averaging. It obtains an acousto-turbulence interaction energy representing the interaction of an acoustic wave field with a turbulence field. The interaction energy gives rise to a scattering wavenumber, a complex-valued correction to the free-space wavenumber. The scattering wavenumber leads to a dispersion and attenuation of the mean waveform due to backscattering, and can be obtained from a derived exact solution. An existing Burgers equation is extended to include the scattering effects of turbulence as an additional linear term. Numerical simulations of an N-wave and a low boom show that the mean scattering effects lead to shock thickening in the mean waveforms as well as reduce the peak amplitudes and total energy contents. The energy reduction is less severe in the low boom than in the N-wave and is dependent on the variance, correlation length, and thickness of the turbulence field.

sonic booms↗

A New Gold Mine? Achieving HVAC Energy Efficiency Through a System Metric

Washington State's Commercial Energy Code adopted a new energy metric called HVAC Total System Performance Ratio (TSPR) in 2019, a first in the codes world to regulate HVAC system efficiency. TSPR is a ratio of annual heating and cooling loads to the annual carbon emissions associated with the energy consumed by the HVAC system. TSPR provides a performance-based solution to evaluate and improve the overall HVAC design. The TSPR metric and its companion calculation tool were developed by Pacific Northwest National Laboratory (PNNL) with support from U.S. Department of Energy (DOE), Northwest Energy Efficiency Alliance (NEEA) and the City of Seattle. The new metric represents a significant shift in how HVAC design will meet code requirements. Utility programs can also leverage TSPR as a measure to determine energy savings and incentive amounts for HVAC retrofits. This paper describes the efforts by NEEA and its collaborators to prepare the market for TSPR adoption in code. This paper provides the pilot projects led by University of Washington Integrated Design Lab (IDL) to understand potential issues that could be faced by early adopters. This paper also covers how training and outreach provide engagement opportunities that can streamline code compliance, help address issues faced by early adopters and promote participation in utility programs. As Washington State works on the goals of 70% energy reduction and zero fossil-fuel greenhouse gas emission homes and buildings by the year 2031 , system level performance metrics will likely become increasingly more necessary and prevalent. This paper concludes that the HVAC TSPR requirement helps familiarize the HVAC industry with this approach and helps Washington achieve its long-term goals.

Liu, Bing↗

The State of Virtual Healthcare

In recent years, telehealth or telemedicine has become an integral component of health systems. During the COVID-19 pandemic, telehealth became the primary route of treatment for patients and doctors. The goals of telehealth are to make healthcare more accessible to patients who have limited mobility, time, or transportation options and those who live in rural or isolated communities. Telehealth aims to improve coordination and care between healthcare teams and their patients. While addressing accessibility, telehealth sets health systems on a path to meet their decarbonization and energy reduction goals. The document provides insights and best practices for telehealth, including carbon reduction, space utilization, equitable access, and technology.

Better Buildings, telehealth, carbon footprint↗

Offline Arterial Signal Timing Optimization based on Virtual Phase Link Model - A Real-world Case Study

Conventional signal timing for arterial usually takes bottom-up approaches. Engineers optimize each individual intersection first and then coordinate them by adjusting the offsets. This work is based on the Virtual Phase-Link (VPL) model, a street traffic model designed for online traffic model predictive control, to obtain a top-down offline arterial signal timing. We Studied the Shallowford Rd. in Chattanooga, TN and found that the inconsistency in intersection capacities along the arterial could lead to some intersections becoming bottlenecks. Signal timing is a significant factor that affect the intersection capacities. We realized that the VPL-based model can guarantee the consistency in intersections along an arterial. We therefore adopted the VPL-based model and developed an offline signal timing optimization approach. The proposed timing derived from the VPL-based offline signal timing optimization showed very good results in simulation. The Chattanooga Department of Transportation adopted the optimized timing obtained from the proposed approach and gave positive feedbacks to the research team. We also collected field experiment data, which demonstrated overall energy reductions and speed improvements on some sections of the Shallowford Rd. arterial. We will continue the experiment when the COVID-19 pandemic impact subsides to have a more robust quantitative evaluation.

Wang, Qichao↗

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID↗

Transformational Sorbent Materials for a Substantial Reduction in the Energy Requirement for Direct Air Capture of CO 2

InnoSepra’s project, “Transformational Sorbent Materials for a Substantial Reduction in the Energy Requirement for Direct Air Capture of CO 2 ,” utilized computational tools, materials characterization, and lab scale testing to optimize previously identified materials to determine their performance under direct air capture conditions. InnoSepra utilized the test results to determine the energy required for regeneration and to develop a high-level process design/analysis to demonstrate the application of developed materials for direct air capture which could be utilized for future techno-economic and life-cycle analyses to fully assess the potential of the materials for direct air capture. InnoSepra also updated the State Point Data Table and completed the environmental, health, and safety (EH&S) Risk Assessment.

99 GENERAL AND MISCELLANEOUS↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices: Preprint

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Carbohydrate supplementation maintains physical performance during short-term energy deficit despite reductions in exogenous glucose oxidation

Short-term (6-day) energy deficit reduced exogenous glucose oxidation during exercise. Though less exogenous glucose was used for fuel, young healthy individuals appear to have a metabolic resilience to short-term periods of low energy availability, with no observed differences in the ability to take up and oxidize exogenous glucose between minimal (20%), moderate (40%), and severe (60%) energy deficits. Similar metabolic responses to carbohydrate supplementation independent of deficit severity likely contributed to sustainment of physical performance.

Margolis, Lee M. (ORCID:0000000206521304)↗

System and method for work function reduction and thermionic energy conversion

A thermionic energy converter, preferably including an anode and a cathode. An anode of a thermionic energy converter, preferably including an n-type semiconductor, one or more supplemental layers, and an electrical contact. A method for work function reduction and/or thermionic energy conversion, preferably including inputting thermal energy to a thermionic energy converter, illuminating an anode of the thermionic energy converter, thereby preferably reducing a work function of the anode, and extracting electrical power from the system.

30 DIRECT ENERGY CONVERSION↗

System and method for work function reduction and thermionic energy conversion

A thermionic energy converter, preferably including an anode and a cathode. An anode of a thermionic energy converter, preferably including an n-type semiconductor, one or more supplemental layers, and an electrical contact. A method for work function reduction and/or thermionic energy conversion, preferably including inputting thermal energy to a thermionic energy converter, illuminating an anode of the thermionic energy converter, thereby preferably reducing a work function of the anode, and extracting electrical power from the system.

Schwede, Jared William↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electron energy loss spectroscopy techniques for the study of microbial chromium(VI) reduction

Electron energy loss spectroscopy (EELS) techniques were used to determine oxidation state, at high spatial resolution, of chromium associated with the metal-reducing bacteria, Shewanella oneidensis, in anaerobic cultures containing Cr(VI)O4(2-). These techniques were applied to fixed cells examined in thin section by conventional transmission electron microscopy (TEM) as well as unfixed, hydrated bacteria examined by environmental cell (EC)-TEM. Two distinct populations of bacteria were observed by TEM: bacteria exhibiting low image contrast and bacteria exhibiting high contrast in their cell membrane (or boundary) structure which was often encrusted with high-contrast precipitates. Measurements by EELS demonstrated that cell boundaries became saturated with low concentrations of Cr and the precipitates encrusting bacterial cells contained a reduced form of Cr in oxidation state + 3 or lower.

Evaluation Studies↗