Search NASA⌕ Search

SEARCH · Search NASA

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Material Model Parameters Optimization in Liquid Mercury Target Dynamics Simulation With Machine Learning Surrogates

A pulsed spallation target is subjected to very short (∼0.7μs) but intense loads (23.3 kJ) from repeated proton pulses, which knock away neutrons from the mercury atoms’ nuclei for a wide range application in physics, engineering, medicine, petroleum exploration, biology, chemistry, etc. The effect of this pulsed loading on the stainless-steel target module which contains the flowing mercury target material is difficult to predict not only due to its short but intense explosive-like physical reaction, but also the nonlinear material behavior of the liquid mercury in the structure. Injecting small helium bubbles in the mercury has been an efficient method of mitigating the pressure wave at high power level stage. However, prediction of the resultant loading on the target is more difficult when helium gas is intentionally injected into the mercury. A 2-phase material model that incorporates the Rayleigh-Plesset (R-P) model is expected to address this complex multi-physics dynamics problem by including the bubble dynamics in the liquid mercury. A parameter sensitivity study was firstly employed to understand their impact on the simulation strains. The investigated parameters included E, μ, γ, σ, n, VFgas, and gas cumulative volume curve control parameters a and b. Verification and validation results from sparse polynomial expansions (SPE) method and directional Gaussian smoothing (DGS) optimization show that the surrogate model had training error of ∼7% and validation error of ∼15%, indicating that machine learning methods and surrogate models can help optimize the uncertain parameters in the complex 2-phase material model. This approach is expected to fill the knowledge gap between unknown liquid-gas mixture material model and measured vessel strain responses.

Lin, Lianshan↗

Correlation of free-response and receiver-operating-characteristic area-under-the-curve estimates: Results from independently conducted FROC/ROC studies in mammography

Purpose: From independently conducted free-response receiver operating characteristic (FROC) and receiver operating characteristic (ROC) experiments, to study fixed-reader associations between three estimators: the area under the alternative FROC (AFROC) curve computed from FROC data, the area under the ROC curve computed from FROC highest rating data, and the area under the ROC curve computed from confidence-of-disease ratings. Methods: Two hundred mammograms, 100 of which were abnormal, were processed by two image-processing algorithms and interpreted by four radiologists under the FROC paradigm. From the FROC data, inferred-ROC data were derived, using the highest rating assumption. Eighteen months afterwards, the images were interpreted by the same radiologists under the conventional ROC paradigm; conventional-ROC data (in contrast to inferred-ROC data) were obtained. FROC and ROC (inferred, conventional) data were analyzed using the nonparametric area-under-the-curve (AUC), (AFROC and ROC curve, respectively). Pearson correlation was used to quantify the degree of association between the modality-specific AUC indices and standard errors were computed using the bootstrap-after-bootstrap method. The magnitude of the correlations was assessed by comparison with computed Obuchowski-Rockette fixed reader correlations. Results: Average Pearson correlations (with 95% confidence intervals in square brackets) were: Corr(FROC, inferred ROC) = 0.76[0.64, 0.84] > Corr(inferred ROC, conventional ROC) = 0.40[0.18, 0.58] > Corr (FROC, conventional ROC) = 0.32[0.16, 0.46]. Conclusions: Correlation between FROC and inferred-ROC data AUC estimates was high. Correlation between inferred- and conventional-ROC AUC was similar to the correlation between two modalities for a single reader using one estimation method, suggesting that the highest rating assumption might be questionable.

60 APPLIED LIFE SCIENCES↗

2D/3D registration algorithm for lung brachytherapy

Purpose: A 2D/3D registration algorithm is proposed for registering orthogonal x-ray images with a diagnostic CT volume for high dose rate (HDR) lung brachytherapy. Methods: The algorithm utilizes a rigid registration model based on a pixel/voxel intensity matching approach. To achieve accurate registration, a robust similarity measure combining normalized mutual information, image gradient, and intensity difference was developed. The algorithm was validated using a simple body and anthropomorphic phantoms. Transfer catheters were placed inside the phantoms to simulate the unique image features observed during treatment. The algorithm sensitivity to various degrees of initial misregistration and to the presence of foreign objects, such as ECG leads, was evaluated. Results: The mean registration error was 2.2 and 1.9 mm for the simple body and anthropomorphic phantoms, respectively. The error was comparable to the interoperator catheter digitization error of 1.6 mm. Preliminary analysis of data acquired from four patients indicated a mean registration error of 4.2 mm. Conclusions: Results obtained using the proposed algorithm are clinically acceptable especially considering the complications normally encountered when imaging during lung HDR brachytherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-303: Quantification of MLC Positioning Accuracy in VMAT Delivery of Head and Neck Cancer Treatment

Purpose: Knowing MLC leaf positioning error over the course of treatment would be valuable for treatment planning, QA design, and patient safety. The objective of the current study was to quantify the MLC positioning accuracy for VMAT delivery of head and neck treatment plans. Methods: A total of 837 MLC log files were collected from 14 head and neck cancer patients undergoing full arc VMAT treatment on one Varian Trilogy machine. The actual and planned leaf gaps were extracted from the retrieved MLC log files. For a given patient, the leaf gap error percentage (LGEP), defined as the ratio of the actual leaf gap over the planned, was evaluated for each leaf pair at all the gantry angles recorded over the course of the treatment. Statistics describing the distribution of the largest LGEP (LLGEP) of the 60 leaf pairs including the maximum, minimum, mean, Kurtosis, and skewness were evaluated. Results: For the 14 studied patients, their PTV located at tonsil, base of tongue, larynx, supraglottis, nasal cavity, and thyroid gland with volume ranging from 72.0 cm{sup 3} to 602.0 cm{sup 3}. The identified LLGEP differed between patients. It ranged from 183.9% to 457.7% with a mean of 368.6%. For the majority of the patients, the LLGEP distributions peaked at non-zero positions and showed no obvious dependence on gantry rotations. Kurtosis and skewness, with minimum/maximum of 66.6/217.9 and 6.5/12.6, respectively, suggested relatively more peaked while right-skewed leaf error distribution pattern. Conclusion: The results indicate pattern of MLC leaf gap error differs between patients of lesion located at similar anatomic site. Understanding the systemic mechanisms underlying these observed error patterns necessitates examining more patient-specific plan parameters in a large patient cohort setting.

60 APPLIED LIFE SCIENCES↗

Measuring the efficiency of control rods in the RBMK critical assembly using a model of RKI-1 reactimeter

The efficiency of control rods of the RBMK critical assembly is measured in a series of experiments. The aim of measurements is to determine the characteristics of the model of an RKI-1 reactimeter. The RKI-1 reactimeter is intended for measuring the efficiency of control rods when, according to conditions of operation, the metrological certification of results of an experiment is required. Complications with the metrological certification of reactimeters arise owing to the fact that usually calculated corrections to the results of measurements are required. When the RKI-1 reactimeter is used, there is no need to introduce calculated corrections; the result of measurements is given with the indication of substantiated errors. In connection with this, the metrological certification of the results of measurements using the RKI-1 reactimeter is simplified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In-memory integration of existing software components for parallel adaptive unstructured mesh workflows

Unstructured mesh methods, like finite elements and finite volumes, support the effective analysis of complex physical behaviors modeled by partial differential equations over general threedimensional domains. The most reliable and efficient methods apply adaptive procedures with a-posteriori error estimators that indicate where and how the mesh is to be modified. Although adaptive meshes can have two to three orders of magnitude fewer elements than a more uniform mesh for the same level of accuracy, there are many complex simulations where the meshes required are so large that they can only be solved on massively parallel systems.

97 MATHEMATICS AND COMPUTING↗

A Hindcast Approach to Diagnosing the Equatorial Pacific Cold Tongue SST Bias in CESM1

An ensemble seasonal hindcast approach is used to investigate the development of the equatorial Pacific Ocean cold sea surface temperature (SST) bias and its characteristic annual cycle in the Community Earth System Model, version 1 (CESM1). In observations, eastern equatorial Pacific SSTs exhibit a warm phase during boreal spring and a cold phase during late boreal summer–autumn. The CESM1 climatology shows a cold bias during both warm and cold phases. In our hindcasts, the cold bias during the cold phase develops in less than 6 months, whereas the cold bias during the warm phase takes longer to emerge. The fast-developing cold-phase cold bias is associated with too-strong vertical advection and easterly wind stress over the eastern equatorial region. The antecedent boreal summer easterly wind anomalies also appear in atmosphere-only simulations, indicating that the errors are intrinsic to the atmosphere component. For the slower-developing warm-phase cold bias, we find that the too-cold SSTs over the equatorial region are associated with a slowly evolving upward displacement of subsurface ocean zonal currents and isotherms that can be traced to the ocean component.

54 ENVIRONMENTAL SCIENCES↗

Chemical Composition and PCT Data for the Initial Set of Hanford Enhanced Waste Loading Glasses

In this report, the Savannah River National Laboratory provides chemical analyses and Product Consistency Test results for 20 simulated high level waste glasses fabricated by the Pacific Northwest National Laboratory. The results of these analyses will be used as part of efforts to revise or extend the validation ranges of the current Hanford Waste Treatment and Immobilization Plant glass property models to cover a broader span of waste compositions. The measured chemical composition data are reported and compared with the targeted values for each component for each glass. Two components of the study glasses, fluorine and silver, were not measured since each of these species would have required the use of an additional preparation method and their measured values were likely to be near or below analytical detection limits. Some of the glasses were difficult to prepare for chemical analysis. A sodium peroxide fusion dissolution method was successful in completely dissolving the glasses. Components present in the glasses in minor concentrations can be difficult to measure using this dissolution method due to dilution requirements. The use of a lithium metaborate preparation method for the minor components (planned for use since it is typically successful in digesting Defense Waste Processing Facility HLW glasses) resulted in an unacceptable amount of undissolved solids remaining in the sample solutions. An acid dissolution method was used instead, which provided more thorough dissolution of the glasses, although a small amount of undissolved material remained for some of the study glasses. The undissolved material was analyzed to determine those components of the glasses that did not fully dissolve. These components (e.g., calcium and chromium) were present in sufficient quantities to be reported from the measurements resulting from the sodium peroxide fusion preparation method, which did not leave undissolved material. Overall, the analyses resulted in sums of oxides that ranged from about 98 to 101.5 wt % for the study glasses, indicating excellent recovery of all the components in the chemical composition analyses. Comparisons of the targeted and measured chemical compositions indicated that, in general, the measured values for the glasses met the targeted concentrations. Exceptions were Cr 2 O 3 , MgO, and P 2 O 5 . The measured values for Cr 2 O 3 were somewhat low when compared to the targeted values for all of the study glasses targeting Cr 2 O 3 concentrations above 0.5 wt %. Many of the measured MgO and P 2 O 5 values were below the targeted values for those glasses that contained these components. Two of the study glasses exhibited differences from the targeted compositions that may indicate a batching error. Glasses EWG-HAI-Centroid-2 and EWG-OL-1672 had measured values for Al 2 O 3 and SiO 2 that were lower than the targeted values, and measured values for B 2 O 3 that were higher than the targeted values. Glass EWG-HAI-Centroid-2 also had a measured value for Fe 2 O 3 that was lower than the targeted value. A review of the PCT data, including standards and blanks, revealed no issues with the performance of the tests. The PCT results were normalized to both the targeted and measured compositions of the study glasses. Comparisons of the normalized PCT results for both the quenched and Canister Centerline Cooled versions of the study glasses are made with the Environmental Assessment benchmark glass for reference.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Technical Report: Moving ASR Cloud Microphysical Retrievals Beyond the Vertical Column

Clouds of all types play important roles in atmospheric heating, surface heating and emission of radiation, hence energy, to space. Clouds not only affect atmospheric heating via their impacts on solar and terrestrial radiation, they also release kinetic energy to the atmosphere when they form and they extract kinetic energy from the atmosphere when they evaporate. To understand the impacts of clouds on weather and climate, one must be able to make accurate observations of the amount of water associated with them and the impact of this water on atmospheric and surface heating rates. One important cloud type is liquid water clouds. Liquid clouds are often found in the boundary layers of Earth at altitudes from just above the surface to approximately 2000 m above it, at a variety of temperatures, including temperatures below the freezing point of liquid water (0 °C). As a result, they are important constituents over the world’s oceans as well as over cold, ice-covered surfaces such as in the Arctic. Observationally estimating the total amount of liquid contained in a column through a liquid water cloud can now be accomplished to acceptable accuracies (except for the thinnest, lowest liquid containing clouds) using instruments called passive microwave radiometers. However, observationally determining the spatial distribution of liquid within these columns has proven to be difficult. The focus of this project was on the application of two radars operating at two different frequencies to retrieve the distribution of liquid water within columns passing through liquid water clouds. Motivation in this project for using two different radars operating at different frequencies is that as overlapping (in space) beams from the two radars pass through the same column of liquid water cloud absorption of power from one beam (the 94-GHz beam) is greater than absorption of power from the other beam (the 35-GHz beam). Therefore, the difference in returned powers between the two radar beams with distance from the radars is proportional to the amount of liquid water that the two beams have passed through. Therefore, one can use the differences in power between the two beams with distance through a liquid water cloud to determine the distribution of liquid water throughout the cloud. The two radars used in this study are the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Program Ka-band Scanning ARM Cloud Radar (Ka-SACR) and the W-band Scanning ARM Cloud Radar (W-SACR). When this projected started in 2013, the Ka- and W-band SACRs were new technology, state-of-the-art sensors. To put together a sufficiently diverse and big set of test cases for the study, data from the SACRs deployed to NSA, SGP, TCAP and MAGIC were used, leading to a test set composed of 65 hours of suitable data spread over approximately 17 case study days. Using the Ka- and W-band SACR data from the case study periods, vertical distributions of liquid water content through liquid water clouds were retrieved. Because there are no other data sets with which to compare the retrievals, distributions of liquid water through a column were summed and compared to the total amounts of liquid water obtained by retrievals applied to passive microwave radiometer observations. The total amounts of liquid water (in units of millimeters, or the thickness in millimeters of the total liquid water in a vertical column if allowed to pool at the bottom of the column) between the two retrievals agreed to within 0.060 mm with a standard deviation of 0.31 mm, or to within 0.016 mm with a standard deviation of 0.12 mm once outliers were removed. The standard deviation of 0.12 mm was fairly independent of the total amount of liquid water in the clouds, indicating that retrieval errors were larger for clouds with smaller amounts of liquid in them. Errors in the retrieved total amounts of liquid were also found to be sensitive to the a priori information that was fed into the retrieval approach. Overall, standard deviations of 0.12 mm are sufficient for some cloud studies but for radiation studies standard deviations on the order of 0.02 mm need to be achieved for clouds with the lowest amounts of liquid water. Many modifications to the retrieval approach were tested subsequently in an attempt to reduce the standard deviations relative to the radiometer retrievals below 0.12 mm but none of them worked reliably. We decided to wait until the DOE ARM Program deployed its second generation SACR2s to its NSA and ENA sites for further retrieval evaluation. The SACR2s were engineered to better synchronize data between the Ka- and W-band radars, reducing potential sources of noise for radar retrieval of liquid water distributions within clouds. The SACR2s have improved in reliability recently and the system deployed to ENA is best positioned to provide the data to advance research on this path. This will be an ongoing research activity beyond the project because of the promise in SACR2 data from the DOE ARM ENA Facility.

58 GEOSCIENCES↗

Electrodynamic Shaker Capability Estimation Through Experimental Dynamic Substructuring [Thesis]

Electrodynamic shaker systems are an essential tool in shock and vibration testing of dynamic environments. However, the specific performance capability of these systems is difficult to characterize. The dynamics of the shaker itself, the device under test and the specific test configuration used all couple to create a dynamic response unique to each test. Poorly predicted limitations in shaker capability affect the ability to achieve test specifications, delay testing schedules, and create difficulties for choosing test equipment. To predict shaker capability for a specific test configuration prior to setup, a lumped parameter model of the shaker system and a modal model of a device under test was developed. These models were then analytically coupled using LaGrange multiplier frequency based substructuring to estimate their coupled frequency response functions. The coupled frequency response functions were used to predict electrical inputs required to meet a given test specification. These input requirements were finally compared to a validation test using the specification and setup. Input requirements estimated using the substructuring estimated frequency response functions showed significant error. However, results using an ideal frequency response function showed very little error. These results indicate that with a better method of experimental dynamic substructuring employed it would be possible to accurately predict shaker capability for a given test configuration prior to setup.

42 ENGINEERING↗

Modeling and Simulation of Xe-100-type Pebble Bed Gas-Cooled Reactor with SCALE

The US Department of Energy (DOE) announced the Advanced Reactor Demonstration Program (ARDP) to accelerate the deployment of advanced reactor concepts. Awardees of ARDP funds are expected to demonstrate the operation of an advanced reactor within 7 years of receiving the award. X-Energy’s advanced reactor concept, the Xe-100, was selected as one of two advanced reactor concepts to receive funding to demonstrate the operation of its high-temperature gas-cooled pebble-bed reactor before the end of this decade. As a result of this push to bring advanced reactors to maturation and commercialization, transition and deployment scenario studies are being performed under the Systems Analysis and Integration (SA&I) campaign within the DOE Office of Nuclear Energy (DOE-NE) to evaluate the transition of the current US commercial fleet of light-water reactors (LWRs) to a future fleet of advanced reactors consisting of a mix of ARDP type reactor concepts and advanced LWRs. To accurately evaluate the front- and back-end resource requirements, it is important to perform reactor physics calculations to determine the discharge burnup and isotopic content, fuel residence time, as well as other parameters. For this purpose, a summer project funded by the SA&I campaign allowed for the setup of SCALE models for full-core Xe-100 type high-temperature gas-cooled pebble-bed reactor and a Xe-100 type slice using publicly available information. The core-averaged equilibrium compositions and zone-wise equilibrium compositions for the slice and 3D models, respectively, were obtained following an iterative depletion method developed by Bostelmann et al. using SCALE’s reactor physics sequence TRITON. The slice model was used with TRITON to generate burnup-dependent cross section libraries at different temperatures which can be used with SCALE’s ORIGAMI code to rapidly determine fuel inventory and therefore to perform quick sensitivity studies on parameters such as the pebble location in the core. The SCALE/TRITON transport and depletion calculation for the Xe-100 type slice model indicates that the isotopic concentrations are in good agreement at 1,300 effective full power days (EFPD) for 235 U. An analysis of 236 U results match 239 Pu results would seem to indicate a typographical error in Mulder and Boyes wherein the reported results of 236 U and 239 Pu are reversed. In addition to SCALE/TRITON calculations, a new capability within SCALE/ORIGAMI for the simulation of pebble-bed reactors was used to study the burnup sensitivity with respect to the pebble pathway through the core. The SCALE/ORIGAMI results show that pebbles that travel closer to the reflector for the entire depletion history have a higher burnup than pebbles that travel through the middle of the core because of the higher thermal to fast flux ratio near the reflector. Consequently, a pebble’s burnup is strongly affected by the pebble’s pathway for each pass. Additional phenomena such as temperature distributions in the core and different travel times of the pebbles in the individual radial zones further affect the burnup distribution. The sensitivity of the discharge vector to the pebble pathways taken during each pass can be evaluated in the future using SCALE/ORIGAMI now that the SCALE inputs have been established.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of Weather Forecasting Products

Meteorological modeling plays a pivotal role in operational safety and emergency response at the Savannah River Site (SRS). This study focuses on verifying the Regional Atmospheric Modelling System (RAMS) Version 4.3 through Mean Bias Error (MBE) and Root Mean Square Error (RMSE) analyses of temperature, dew point, and wind speed over a decade. Using observed data from SRS, we assessed RAMS' accuracy, revealing seasonal biases and error trends. Results indicate RAMS' strengths in mild weather conditions but challenges during seasonal extremes and wind speed predictions due to measurement disparities. Future research aims to expand verification to other models and parameters, advocating for enhanced forecasting accuracy crucial for safeguarding personnel and community well-being.

42 ENGINEERING↗

Measuring Radioactivity from Fukushima Daiichi in New Mexico

On March 11, 2011, the Fukushima Daiichi nuclear power plant was damaged by the tsunami that followed the 'Great East Japan Earthquake,' and the reactor subsequently leaked radioactive material. In response, LANL augmented the routine ambient (AIRNET) and stack (Rad-NESHAP) measurements with three high-volume samplers: No.167 at the Old White Rock Fire Station; No.173 at the TA-49 gate, and No.211 at the Los Alamos Medical Center. Previous accidents, such as the Three-Mile-Island accident in 1979 and the Chernobyl accident in 1986, indicated that the most likely releases were (a) the noble gases: krypton and xenon; and (b) the volatile elements: cesium, tellurium, and iodine. At the latitude of Fukushima, the predominant winds across the Pacific Ocean are from west to east, and models predicted that the plume would arrive in the western US on about March 18. By this time the shorter-lived isotopes would have decayed. Therefore, the expected radionuclides were xenon-133, cesium-134, cesium-136, cesium-137, tellurium-132, iodine-131, and iodine-132. As expected, cesium-134, cesium-136, cesium-137, tellurium-132, iodine-131, and iodine-132 were all detected by all three high-volume samplers during March 17-21. The concentrations peaked during the March 24-28 period. After this, concentrations of all nuclides declined. In general, the concentrations were consistent with those measured by the EPA RadNet system and many other monitoring systems throughout the world. At the time of writing, preliminary results from the AIRNET and Rad-NESHAP systems are being reported. More detailed results are described in LA-UR-11-10304 and will be reported in full in the annual environmental report for 2011. All previous releases from nuclear reactors have been dominated by noble gases, primarily krypton and xenon, which are not measured by the high-volume samplers or the AIRNET system. However, in sufficient concentrations these and other fission products would be detected by NEWNET. Consistent with this possibility, all NEWNET detectors recorded an increase of 0.2 {micro}R/h from March 19-1, followed by an additional increase of 0.1 {micro}R/h on March 24 (Figure 1). The consistency of the NEWNET stations is indicated by the error bars, which represent the standard error of the mean of the individual stations. Over the next 10 days, the NEWNET readings declined with approximately the 5-day half life of xenon-133, returning to near normal levels on April 2. After this, any further decrease was masked by high radon concentrations on April 3, by a weather system that moved into New Mexico on April 4, and by rainfall on April 6-9. Furthermore, it is likely that all NEWNET detectors responded to a gradually increasing trend in terrestrial radiation during the month of March as the ground dried out. It is difficult to distinguish the hypothetical effects of xenon-133 from the fluctuations of radon decay products. However, at present we do not have an alternative hypothesis for the sharp increase that was observed in all NEWNET stations from March 19-21. Perhaps some of the increase was caused by radon or terrestrial radiation, in which case the observed increase is an upper limit to that caused by releases from Fukushima. LANL data are consistent with those of the EPA RadNet monitoring system. The EPA has repeatedly stated that 'The levels detected are far below levels of concern.'

CESIUM 134↗

Stillwater Hybrid Geo-Solar Power Plant Optimization Analyses

The Stillwater Power Plant is the first hybrid plant in the world able to bring together a medium-enthalpy geothermal unit with solar thermal and solar photovoltaic systems. Solar field and power plant models have been developed to predict the performance of the Stillwater geothermal / solar-thermal hybrid power plant. The models have been validated using operational data from the Stillwater plant. A preliminary effort to optimize performance of the Stillwater hybrid plant using optical characterization of the solar field has been completed. The Stillwater solar field optical characterization involved measurement of mirror reflectance, mirror slope error, and receiver position error. The measurements indicate that the solar field may generate 9% less energy than the design value if an appropriate tracking offset is not employed. A perfect tracking offset algorithm may be able to boost the solar field performance by about 15%. The validated Stillwater hybrid plant models were used to evaluate hybrid plant operating strategies including turbine IGV position optimization, ACC fan speed and turbine IGV position optimization, turbine inlet entropy control using optimization of multiple process variables, and mixed working fluid substitution. The hybrid plant models predict that each of these operating strategies could increase net power generation relative to the baseline Stillwater hybrid plant operations.

15 GEOTHERMAL ENERGY↗

The limits and challenges of error field correction for ITER

Significant progress has been made in interpreting the effects of non-axisymmetric 'error' fields on a plasma through ideal MHD stability and a dominant 'least stable' ideal mode through which the fields couple to the tearing resonant surface. However, in contrast to expectations from such theories, experiments have found limited success in correcting error fields, with single correction coil arrays giving benefits of between 0% and {approx}50% correction (in terms of improvement to a low density locked mode limit), dependent on the structure of the error and correcting fields. With additional coils up to {approx}70% is possible. It was unclear whether this represented an intrinsic stability or control limit, or higher order toroidal or poloidal harmonic effects. Thus, studies on the DIII-D tokamak explored correction of a proxy error field, using two differently structured coil arrays. This enabled the principles of error correction to be tested at high amplitudes and operational densities, with known pure n=1 fields. Results showed substantial residual effects from the corrected n=1 field, with improvements of only {approx}50% in the low density locked mode limit. This suggests that n=1 error fields must couple to more than one surface in the plasma, and this is conjectured to be through more than one ideal mode, thereby requiring precise correction. For ITER, updated predictions of field error have been obtained and compared with revised scalings for tearing mode thresholds, indicating 50% or better error field correction will be needed. This will likely require more than one well coupled correction coil array and sets a challenge for theory to model the behavior, in order to clarify the plasma response and braking mechanisms, and so the effectiveness of ITER's correction coils and the possible need for support from its edge localized mode control coils.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-C-BRE-01: KEYNOTE PRESENTATION - Emerging Frontiers in IMRT QA

As IMRT treatment processes advance and mature, so must the quality assurance processes being used to validate their delivery. In some respects, treatment delivery advancements (e.g. VMAT) have out-paced QA advancements. The purpose of this session is to describe new processes that are being implemented to bring IMRT QA up-to-date with the treatment delivery advances. It would explore emerging IMRT QA paradigms, including requirements-based IMRT QA which necessitates definition of delivery errors (e.g. patient dose error, leaf positioning error) and development of processes to ensure reliable error detection. Engineeringbased QA approaches, including use of IMRT treatment delivery process trees, fault tree analysis and failure modes effects analysis would be described. Approaches to detect errors such as (1) during treatment delivery validation using exit fluence detectors (e.g. EPIDs); (2) analysis of treatment delivery via use of machine parameter log files; (3) dose recalculation using (3a) treatment planning system; (3b) record-and-verify; or (3c) entrance and exit fluence measurement parameters would be explained. The relative advantages and disadvantages of each method would be discussed. Schemes for error classification and root cause analysis would be described – steps which are essential for future error prevention. For each QA method, testing procedures and results would be presented indicating the types of errors that can be detected, those that cannot be detected, and the reliability of the error detection method (for example determined via ROC analysis). For speakers, we are seeking to engage non-commercially biased experts. Those listed below are a sub-sample of possible qualified individuals.

60 APPLIED LIFE SCIENCES↗

Modeling forest site productivity using mapped geospatial attributes within a South Carolina Landscape, USA

Spatially explicit mapping of forest productivity is important to assess many forest management alternatives. We assessed the relationship between mapped variables and site index of forests ranging from southern pine plantations to natural hardwoods on a 74,000-ha landscape in South Carolina, USA. Mapped features used in the analysis were soil association, land use condition in 1951, depth to groundwater, slope and aspect. Basal area, species composition, age and height were the tree variables measured. Linear modelling identified that plot basal area, depth to groundwater, soils association and the interactions between depth to groundwater and forest group, and between land use in 1951 and forest group were related to site index (SI) (R 2 =0.37), but this model had regression attenuation. We then used structural equation modeling to incorporate error-in-measurement corrections for basal area and groundwater to remove bias in the model. We validated this model using 89 independent observations and found the 95% confidence intervals for the slope and intercept of an observed vs. predicted site index error-corrected regression included zero and one, respectively, indicating a good fit. With error in measurement incorporated, only basal area, soil association, and the interaction between forest groups and land use were important predictors (R2 =0.57). Thus, we were able to develop an unbiased model of SI that could be applied to create a spatially explicit map based primarily on soils as modified by past (land use and forest type) and recent forest management (basal area).

54 ENVIRONMENTAL SCIENCES↗

Evidence for Reduced, Carbon-rich Regions in the Solar Nebula from an Unusual Cometary Dust Particle

Geochemical indicators in meteorites imply that most formed under relatively oxidizing conditions. However, some planetary materials, such as the enstatite chondrites, aubrite achondrites, and Mercury, were produced in reduced nebular environments. Because of large-scale radial nebular mixing, comets and other Kuiper Belt objects likely contain some primitive material related to these reduced planetary bodies. Here, we describe an unusual assemblage in a dust particle from comet 81P/Wild 2 captured in silica aerogel by the NASA Stardust spacecraft. The bulk of this ∼20 μ m particle is comprised of an aggregate of nanoparticulate Cr-rich magnetite, containing opaque sub-domains composed of poorly graphitized carbon (PGC). The PGC forms conformal shells around tiny 5–15 nm core grains of Fe carbide. The C, N, and O isotopic compositions of these components are identical within errors to terrestrial standards, indicating a formation inside the solar system. Magnetite compositions are consistent with oxidation of reduced metal, similar to that seen in enstatite chondrites. Similarly, the core–shell structure of the carbide + PGC inclusions suggests a formation via FTT reactions on the surface of metal or carbide grains in warm, reduced regions of the solar nebula. Together, the nanoscale assemblage in the cometary particle is most consistent with the alteration of primary solids condensed from a C-rich, reduced nebular gas. The nanoparticulate components in the cometary particle provide the first direct evidence from comets of reduced, carbon-rich regions that were present in the solar nebula.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗