Search NASA⌕ Search

SEARCH · Search NASA

Results for “error quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Statistical Error Analysis on White-Light Filter Ratio Experiments to Measure Electron Parameters

The Filter ratio technique to remotely measure electron temperature and speed using four color filters in visible light and a polarization camera was described in detail in four articles by Reginald et al., Solar physics, (2018, 2019a, 2019b, 2020). In these four articles we quantified the systematic error associated with using models of symmetric corona to interpret results from asymmetric corona. We also showed the criteria applied to select the bandwidths of filters, and the pros and cons of replacing the traditional linear polarizer with a polarization camera to measure pB. What started in 1990s as ground experiments conducted during total solar eclipses that lasted for a few minutes lead to a balloon borne experiment lasting eight hours in 2019 and will blossom into a space experiment on the International Space Station in 2023. Due to constraints on the bandwidths of the four filters, a successful mission requires quantification of the statistical error using Monte Carlo simulation to generate two feasibility profiles, which are unique to the design parameters of the coronagraph, to comprehend the feasibility to measure temperature and speed within the desired temporal and spatial resolutions. For the statistical error analysis, we use modeled K and F corona profiles, representative theoretical diffraction, scattering, and vignetting profiles, assumed efficiencies for lenses, mirrors, and polarizers, assumed detector properties on quantum efficiency, full well depth, dark noise, and read noise, and assumed instrument properties on aperture diameter, solid angle, and pixel resolution. We hope future white-light coronagraphs will exhibit capabilities to measure electron density, temperature, and speed.

Nelson Reginald↗

Spatial DIC Errors due to Pattern-Induced Bias and Grey Level Discretization

Digital image correlation (DIC) is an optical metrology method widely used in experimental mechanics for full-field shape, displacement and strain measurements. The required strain resolution for engineering applications of interest mandates DIC to have a high image displacement matching accuracy, on the order of 1/100th of a pixel, which necessitates an understanding of DIC errors. In this paper, we examine two spatial bias terms that have been almost completely overlooked. They cause a persistent offset in the matching of image intensities and thus corrupt DIC results. We name them pattern-induced bias (PIB), and intensity discretization bias (IDB). We show that the PIB error occurs in the presence of an undermatched shape function and is primarily dictated by the underlying intensity pattern for a fixed displacement field and DIC settings. The IDB error is due to the quantization of the gray level intensity values in the digital camera. In this paper we demonstrate these errors and quantify their magnitudes both experimentally and with synthetic images.

47 OTHER INSTRUMENTATION↗

Assessment of Planning Target Volume Margins for Intensity-Modulated Radiotherapy of the Prostate Gland: Role of Daily Inter- and Intrafraction Motion

Purpose: To determine planning target volume margins for prostate intensity-modulated radiotherapy based on inter- and intrafraction motion using four daily localization techniques: three-point skin mark alignment, volumetric imaging with bony landmark registration, volumetric imaging with implanted fiducial marker registration, and implanted electromagnetic transponders (beacons) detection. Methods and Materials: Fourteen patients who underwent definitive intensity-modulated radiotherapy for prostate cancer formed the basis of this study. Each patient was implanted with three electromagnetic transponders and underwent a course of 39 treatment fractions. Daily localization was based on three-point skin mark alignment followed by transponder detection and patient repositioning. Transponder positioning was verified by volumetric imaging with cone-beam computed tomography of the pelvis. Relative motion between the prostate gland and bony anatomy was quantified by offline analyses of daily cone-beam computed tomography. Intratreatment organ motion was monitored continuously by the Calypso (registered) System for quantification of intrafraction setup error. Results: As expected, setup error (that is, inter- plus intrafraction motion, unless otherwise stated) was largest with skin mark alignment, requiring margins of 7.5 mm, 11.4 mm, and 16.3 mm, in the lateral (LR), longitudinal (SI), and vertical (AP) directions, respectively. Margin requirements accounting for intrafraction motion were smallest for transponder detection localization techniques, requiring margins of 1.4 mm (LR), 2.6 mm (SI), and 2.3 mm (AP). Bony anatomy alignment required 2.1 mm (LR), 9.4 mm (SI), and 10.5 mm (AP), whereas image-guided marker alignment required 2.8 mm (LR), 3.7 mm (SI), and 3.2 mm (AP). No marker migration was observed in the cohort. Conclusion: Clinically feasible, rapid, and reliable tools such as the electromagnetic transponder detection system for pretreatment target localization and, subsequently, intratreatment target location monitoring allow clinicians to reduce irradiated volumes and facilitate safe dose escalation, where appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Intrafraction and Interfraction Tumor Motion Amplitude and Prediction Error for Different Liver Tumor Trajectories in Cyberknife Synchrony Tracking

To research the fiducial-based, real-time tracking intrafraction (during the fraction [intra-]) and interfraction (between fractions [inter-]) tumor respiration amplitude, motion trajectory, and prediction error and quantify their relationships for different types of motion trajectories during Cyberknife-based stereotactic ablation radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stochastic multiscale modeling for quantifying statistical and model errors with application to composite materials

This paper provides a coherent and efficient computational framework for stochastic multiscale analysis of material systems in the presence of parametric uncertainties and modeling errors. Uncertainty in those model parameters that are not deduced as upscaled quantities is attributed to an uncertainty “germ”. While such parameters can appear at any scale, they are predominant at the finest analysis scale. Additional uncertainties stemming from statistical estimation, attributed to lack of data and model error, are associated with each submodel contributing to the multiscale system. Here, a robust and efficient framework based on a generalized extended polynomial chaos expansion (gEPCE) is proposed to simultaneously propagate all these uncertainties in order to provide a probabilistic representation of specific quantities of interest (QoI). We characterize the full probability distribution of the QoI and the uncertainty in the failure probability pertaining to its tails. By combining gEPCE with kernel density estimation (KDE) and directional derivatives, we construct sensitivity measures that connect these statistical metrics of QoI to the various sources of uncertainty to assess their individual and combined impacts. An illustrative problem featuring three-point bending of a composite beam is investigated to demonstrate the presented approach.

36 MATERIALS SCIENCE↗

SU-C-BRD-01: Multi-Centre Collaborative Quality Assurance Program for IMRT Planning and Delivery: Year 3 Results

Purpose: A multi-centre quality assurance program was developed to enable quality improvement by coupling measurement of intensity modulated radiotherapy (IMRT) planning and delivery performance for site-specific planning exercises with diagnostic testing. The third year of the program specifically assessed the quality of spine stereotactic body radiotherapy (SBRT) planning and delivery amongst the participating centres. Methods: A spine SBRT planning exercise (24 Gy in 2 fractions) was created and completed by participants prior to an on-site visit. The delivery portion of the on-site visit included spine SBRT plan delivery and diagnostic testing, which included portal image acquisition for quantification of phantom positioning error and multi-leaf collimator (MLC) calibration accuracy. The measured dose was compared to that calculated in the treatment planning system (TPS) using 3%/2mm composite analysis and 3%/3mm gamma analysis. Results: Fourteen institutions participated, creating 17 spine SBRT plans (15 VMAT and 2 IMRT). Three different TPS, two beam energies (6 MV and 6 MV FFF), and four MLC designs from two linac vendors were tested. Large variation in total monitor units (MU) per plan (2494–6462 MU) and dose-volume parameters was observed. The maximum point dose in the plans ranged from 116–149% and was dependent upon the TPS used. Pass rates for measured to planned dose comparison ranged from 89.4–100% and 97.3–100% for 3%/2mm and 3%/3mm criteria respectively. The largest measured MLC error did Result in one of the poorer pass rates. No direct correlation between phantom positioning error and pass rates overall. Conclusion: Significant differences were observed in the planning exercise for some plan and dose-volume parameters based on the TPS used. Standard evaluation criteria showed good agreement between planned and measured dose for all participants, however on an individual plan basis, diagnostic tests were able to identify contributing factors for poorer results, when using more stringent evaluation criteria. Funding from Cancer Care Ontario is acknowledged.

60 APPLIED LIFE SCIENCES↗

Implementation of stacked ensemble machine learning for the detection of surrogate plutonium contamination in soil via LIBS

Supervised machine learning methods have demonstrated increased utility for the quantification of lanthanide and actinide elements in atomic spectroscopy applications. This study implements laser-induced breakdown spectroscopy (LIBS) for the identification of plutonium surrogate material (CeO 2 ) in soil matrices by training supervised machine learning methods on the recorded spectral data. A bagged ensemble using Random Forest yields the highest sensitivity predictions with a detection limit of 0.015 wt.% CeO 2 . However, high precision in Ce content prediction required the use of a stacked ensemble regression, which provided the superlative Ce quantification model with an error of 0.107% and a detection limit of 0.022 wt.%. Furthermore, the high performance of the stacked ensemble demonstrates its potential to enhance the accuracy and sensitivity of nuclear contaminant detection using field-deployable spectroscopic analyzers in real-world scenarios.

47 OTHER INSTRUMENTATION↗

An autonomous Nimbus Doppler positioning system

A single-pass Doppler positioning system was developed at the GSFC in support of the Nimbus-6 mission. The system was designed to satisfy the following requirements: compatibility with the PDP 11/70 minicomputer; single-pass recovery of up to 250 positions with a two-sigma accuracy of 5 km; high reliability with a minimum of human interaction; and near real-time responsiveness. The system consists of a numerical integrator which includes only the J2 term (earth flattening) of the earth's gravity field, an editing routine, a first guess algorithm, a least squares position recovery program, and a routine for generating a 95% confidence circle based on a computer covariance matrix. An analysis and quantification of the following error sources that limit system accuracy are presented: orbit error, radial aliasing, computational difficulties with overhead passes, oscillator drift, and ambiguity problems. Results of system reliability tests and sample outputs are included.

Garza-Robles, R.↗

A TWO-DIMENSIONAL METHOD OF MANUFACTURED SOLUTIONS BENCHMARK SUITE BASED ON VARIATIONS OF LARSEN'S BENCHMARK WITH ESCALATING ORDER OF SMOOTHNESS OF THE EXACT SOLUTION

The quantification of the discretization error associated with the spatial discretization of the Discrete Ordinate(DO) equations in multidimensional Cartesian geometries is the central problem in error estimation of spatial discretization schemes for transport theory as well as computer code verification. Traditionally fine mesh solutions are employed as reference, because analytical solutions only exist in the absence of scattering. This approach, however, is inadequate when the discretization error associated with the reference solution is not small compared to the discretization error associated with the mesh under scrutiny. Typically this situation occurs if the mesh of interest is only a couple of refinement levels away from the reference solution or if the order of accuracy of the numerical method (and hence the reference as well) is lower than expected. In this work we present a Method of Manufactured Solutions (MMS) benchmark suite with variable order of smoothness of the underlying exact solution for two-dimensional Cartesian geometries which provides analytical solutions aver- aged over arbitrary orthogonal meshes for scattering and non-scattering media. It should be emphasized that the developed MMS benchmark suite first eliminates the aforementioned limitation of fine mesh reference solutions since it secures knowledge of the underlying true solution and second that it allows for an arbitrary order of smoothness of the underlying ex- act solution. The latter is of importance because even for smooth parameters and boundary conditions the DO equations can feature exact solution with limited smoothness. Moreover, the degree of smoothness is crucial for both the order of accuracy and the magnitude of the discretization error for any spatial discretization scheme.

99 GENERAL AND MISCELLANEOUS↗

Embedded Model Error Representation for Bayesian Model Calibration

Model error estimation remains one of the key challenges in uncertainty quantification and predictive science. For computational models of complex physical systems, model error, also known as structural error or model inadequacy, is often the largest contributor to the overall predictive uncertainty. This work builds on a recently developed framework of embedded, internal model correction, in order to represent and quantify structural errors, together with model parameters,within a Bayesian inference context. We focus specifically on a Polynomial Chaos representation with additive modification of existing model parameters, enabling a non-intrusive procedure for efficient approximate likelihood construction, model error estimation, and disambiguation of model and data errors’ contributions to predictive uncertainty. The framework is demonstrated on several synthetic examples, as well as on a chemical ignition problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Separability of Mesh Bias and Parametric Uncertainty for a Full System Thermal Analysis

When making computational simulation predictions of multiphysics engineering systems, sources of uncertainty in the prediction need to be acknowledged and included in the analysis within the current paradigm of striving for simulation credibility. A thermal analysis of an aerospace geometry was performed at Sandia National Laboratories. Here, for this analysis, a verification, validation, and uncertainty quantification (VVUQ) workflow provided structure for the analysis, resulting in the quantification of significant uncertainty sources including spatial numerical error and material property parametric uncertainty. It was hypothesized that the parametric uncertainty and numerical errors were independent and separable for this application. This hypothesis was supported by performing uncertainty quantification (UQ) simulations at multiple mesh resolutions, while being limited by resources to minimize the number of medium and high resolution simulations. In conclusion, based on this supported hypothesis, a prediction including parametric uncertainty and a systematic mesh bias is used to make a margin assessment that avoids unnecessary uncertainty obscuring the results and optimizes use of computing resources.

42 ENGINEERING↗

Comparison of XSUSA and "Two-Step" Approaches for Full Core Uncertainty Quantification

While there are multiple sources of error that are introduced into the standard computational regime for simulating reactor cores, rigorous uncertainty analysis methods are available primarily for quantifying the effects of cross section uncertainties. Two methods for propagating cross section uncertainties through core simulators are the XSUSA statistical approach and the 'Two-Step' method. The XSUSA approach, which is based on the SUSA code package, is fundamentally a stochastic sampling method. Alternatively, the Two-Step method utilizes generalized perturbation theory in the first step and stochastic sampling in the second step. The consistency of these two methods in quantifying uncertainties in the multiplication factor and in the core power distribution will be examined in the framework of phase I-3 of the UAM Benchmark. Using the TMI core as a base model for analysis, the XSUSA and Two-Step methods are applied with certain limitations and the results are compared to those produced by other stochastic sampling-based codes. Based on the uncertainty analysis results, conclusions are made for which method is currently a more viable option for computing uncertainties in burnup and transient calculations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of XSUSA and 'two-step' approaches for full-core uncertainty quantification

While there are multiple sources of error that are introduced into the standard computational regime for simulating reactor cores, rigorous uncertainty analysis methods are available primarily for quantifying the effects of cross section uncertainties. Two methods for propagating cross section uncertainties through core simulators are the XSUSA statistical approach and the 'Two-Step' method. The XSUSA approach, which is based on the SUSA code package, is fundamentally a stochastic sampling method. Alternatively, the Two-Step method utilizes generalized perturbation theory in the first step and stochastic sampling in the second step. The consistency of these two methods in quantifying uncertainties in the multiplication factor and in the core power distribution will be examined in the framework of phase 1-3 of the UAM Benchmark. Using the TMI core as a base model for analysis, the XSUSA and Two-Step methods are applied with certain limitations and the results are compared to those produced by other stochastic sampling-based codes. Based on the uncertainty analysis results, conclusions are made for which method is currently a more viable option for computing uncertainties in burnup and transient calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Magnetic Resonance Imaging Assessment of Spinal Cord and Cauda Equina Motion in Supine Patients With Spinal Metastases Planned for Spine Stereotactic Body Radiation Therapy

Purpose: To assess motion of the spinal cord and cauda equina, which are critical neural tissues (CNT), which is important when evaluating the planning organ-at-risk margin required for stereotactic body radiation therapy. Methods and Materials: We analyzed CNT motion in 65 patients with spinal metastases (11 cervical, 39 thoracic, and 24 lumbar spinal segments) in the supine position using dynamic axial and sagittal magnetic resonance imaging (dMRI, 3T Verio, Siemens) over a 137-second interval. Motion was segregated according to physiologic cardiorespiratory oscillatory motion (characterized by the average root mean square deviation) and random bulk shifts associated with gross patient motion (characterized by the range). Displacement was evaluated in the anteroposterior (AP), lateral (LR), and superior-inferior (SI) directions by use of a correlation coefficient template matching algorithm, with quantification of random motion measure error over 3 separate trials. Statistical significance was defined according to P<.05. Results: In the AP, LR, and SI directions, significant oscillatory motion was observed in 39.2%, 35.1%, and 10.8% of spinal segments, respectively, and significant bulk motions in all cases. The median oscillatory CNT motions in the AP, LR, and SI directions were 0.16 mm, 0.17 mm, and 0.44 mm, respectively, and the maximal statistically significant oscillatory motions were 0.39 mm, 0.41 mm, and 0.77 mm, respectively. The median bulk displacements in the AP, LR, and SI directions were 0.51 mm, 0.59 mm, and 0.66 mm, and the maximal statistically significant displacements were 2.21 mm, 2.87 mm, and 3.90 mm, respectively. In the AP, LR, and SI directions, bulk displacements were greater than 1.5 mm in 5.4%, 9.0%, and 14.9% of spinal segments, respectively. No significant differences in axial motion were observed according to cord level or cauda equina. Conclusions: Oscillatory CNT motion was observed to be relatively minor. Our results support the importance of controlling bulk patient motion and the practice of applying a planning organ-at-risk margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extraction of the neutron F 2 structure function from inclusive proton and deuteron deep-inelastic scattering data

The available world deep-inelastic scattering (DIS) data on proton and deuteron structure functions F 2 p , F 2 d , and their ratios are leveraged to extract the free neutron F 2 n structure function, the F 2 n / F 2 p ratio, and associated uncertainties using the latest nuclear effect calculations in the deuteron. Special attention is devoted to the normalization of the proton and deuteron experimental datasets and to the treatment of correlated systematic errors, as well as the quantification of procedural and theoretical uncertainties. The extracted F 2 n dataset is utilized to evaluate the Q 2 dependence of the Gottfried sum rule and the nonsinglet F 2 p − F 2 n moments. To facilitate replication of our study, as well as for general applications, we provide a comprehensive DIS database including all recent Jefferson Lab 6 GeV measurements, the extracted F n 2 , a modified CTEQ-JLab global parton distribution function fit named CJ15nlo_mod, and grids with calculated proton, neutron, and deuteron DIS structure functions. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗