Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaporative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Co-treating flue gas desulfurized effluent and produced water enables novel waste management and recovery of critical minerals

Herein this study reports a novel approach of resource recovery from co-managing two geographically co-located and chemically complementary wastewaters using a pilot-scale treatment process. Designed to treat flue gas desulfurized (FGD) effluent from combustion powerplants and produced water (PW) from energy industries, the process consists of soda-ash softening, nanofiltration (NF), and reverse osmosis (RO). Recovered products are barite, calcite, and low-salinity water. Using field-collected waters, the results show that softening at pH 8.5 produces calcite (yield: 30 kg/m 3 treated water), a chemical used as SO ₂(g) scrubbers. NF treatment under an applied pressure of 3.5 MPa yields a permeate stream laden with monovalent ions (water recovery 60%) and a concentrate stream with a sulfate concentration 1.8 times of the feedwater concentration. Mixing the NF concentrate and PW at a volumetric ratio of 1.0 precipitates a high-density barite material (4.1 g/cm 3 , yield: ~7.5 kg/m 3 mixture) – a critical mineral commonly used as a weighting agent in drilling. The RO treatment recovers >64% water as the permeate, which can be readily used as cooling make-up water at the powerplants. The RO concentrate stream can be further processed in a thermal evaporative system for additional water recovery and brine production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fouling mechanism in airblast atomizers and its suppression for water desalination

A detailed experimental study is presented on fouling behavior of the anti-clogging perforated plate atomizer designed for high salinity applications, and compared with a conventional (plain-jet) airblast atomizer. Low-pressure regions around fast moving air in the outer layer of spray (as in conventional atomizers: plain-jet and prefilming) due to Venturi suction were identified as the root cause of atomizer clogging, as they facilitate salt accumulation on the atomizer surface from spray. Accordingly, severe atomizer fouling, and fluctuations in spray cone angle were observed in the conventional airblast atomizer over 2 h at 100°C air and 50°C saline (44° to 76° at 35,000 ppm, and 44° to 91° at 100,000 ppm). In this regard, the perforated plate atomizer provides a novel liquid-film airblast atomization by maintaining a liquid-annulus film (around the air outlet) as the outer layer of spray. Doing so we achieved nearly complete suppression of fouling, and spray cone angle fluctuations (28° ± 1° at 35,000 ppm, and 30° ± 1° at 100,000 ppm). Later, novel liquid-film atomization was adopted in the conventional airblast atomizer. While, the conventional airblast atomization needed atomizer cleaning/maintenance after 35 min for 175°C air and 65°C saline at 100,000 ppm, the liquid-film atomization showed no sign of fouling over 14 h. Hence, current work establishes a benchmark liquid-film airblast atomization mechanism in the anti-clogging perforated plate atomizer for complete suppression of fouling in airblast atomization. Furthermore, this extends the application of airblast atomizers from high evaporation jet engines to ZLD-HDH desalination systems, spraying, powder metallurgy, pharmaceuticals and hospitals, and spray drying and cooling.

42 ENGINEERING↗

Scalable and Resilient Etched Metallic Micro- and Nanostructured Surfaces for Enhanced Flow Boiling

Flow boiling and evaporation in tubes and channels occur in a wide variety of energy systems, such as refrigeration, air conditioning, power generation, electronics cooling, distillation, and purification. In this work, we demonstrate remarkably increased heat transfer coefficients of 270% during refrigerant flow boiling in scalable microstructured (~40 µm), industrial-scale (~1 m long) aluminum (Al) tubes, when compared to smooth unstructured Al tubes. To achieve scalable nanomanufacturing, we create highly conformal and durable structured surfaces by relying on hydrochloric acid Al etching. Flow boiling tests were conducted in 6.35 mm diameter Al tubes using R134a refrigerant as the working fluid. To benchmark our approach and to elucidate the effect of the structure length scale, we also fabricated ultrascalable boehmite (AlO(OH)) nanostructured (~300 nm) Al tubes, showing that etched microscale features are necessary and key to enhancement. Durability tests conducted using a 28 day long continual flow boiling experiment demonstrated negligible degradation of the etched surfaces. The scalable and cost-effective techniques used to create these durable, etched-Al microstructures may significantly reduce manufacturing cost when contrasted with current enhancement approaches such as extrusion, drawing, and welding.

36 MATERIALS SCIENCE↗

Hygroscopic cooling tower for waste water disposal

In various embodiments, the present invention relates to heat dissipation systems including a hygroscopic working fluid integrating waste water as makeup water. The present invention also relates to methods of using the same. The present invention also relates to hygroscopic cooling systems adapted to dispose of waste water by combining the waste water with a hygroscopic working fluid, precipitating impurities and evaporating the remaining water.

Martin, Christopher Lee↗

Hygroscopic cooling tower for waste water disposal

In various embodiments, the present invention relates to heat dissipation systems including a hygroscopic working fluid integrating waste water as makeup water. The present invention also relates to methods of using the same. The present invention also relates to hygroscopic cooling systems adapted to dispose of waste water by combining the waste water with a hygroscopic working fluid, precipitating impurities and evaporating the remaining water.

Martin, Christopher Lee↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

A mechanistic understanding of oxygen isotopic changes in the Western United States at the Last Glacial Maximum

At the Last Glacial Maximum (LGM), records suggest drier conditions in the northwest United States and wetter conditions in the southwest United States relative to present-day as well as widespread changes in the isotopic composition of water. However, the mechanisms responsible for these changes remain ambiguous. Here, we explore differences in western United States hydroclimate between the LGM and preindustrial with a water isotope tracer enabled Earth System Model. We then use proxy forward models to compare simulated and recorded δ 18 O in speleothems. We find that the pattern of hydroclimate response in the western United States at the LGM relates to a combination of 1) increased frequency and southward shifted wintertime extratropical cyclones in the North Pacific, 2) greater rainout of moisture as it moves over the continent, and 3) reduced evaporation in the cooler LGM climate. The simulated lower δ 18 O of precipitation at the LGM relates predominantly to an increase in cool season moisture removal efficiency, with a secondary contribution from relatively more cool season precipitation. Both surface temperatures and North American ice sheets contribute to these hydroclimate changes at the LGM. Comparisons between δ 18 O from proxy forward models and speleothem records in the western United States show general agreement at the LGM, with increasing depletion moving towards the continental interior. Finally, this study highlights the similarities and differences between hydrologic and δ 18 O changes at the LGM and emphasizes the utility of model-proxy comparison for interpretation.

54 ENVIRONMENTAL SCIENCES↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring the Limits of Cooling for Extreme Heat Flux Applications: Data Centers and Power Electronic

We developed an Extreme Heat Flux Micro-cooler (EHFµ-C) capable of removing heat flux of ~1 kW/cm 2 with a small temperature rise ~10°C. This represents greater than 10× reduction in thermal resistance compared to the state-of-the-art single-phase cooling technologies (~0.5 cm 2 -°C/W) that greatly increases the efficiency, resulting in improved performance and reliability for microprocessors and power electronics. The EHFµ-Cooler utilizes liquid wicking (no pump) and thin-film evaporation in a 30 µm thick wick porous microstructure such as copper inverse opal (CIO), silicon and AlN pin fins along with a 3D manifold (copper wiremesh and silicon) with liquid routing and vapor extraction channels achieving an unprecedented vapor quality ~ >0.9. The proposed EHFµ-Cooler significantly reduces device temperature, resulting in 25-50% improvement in reliability and device performance. Based on very conservative estimates, the total energy saving for data centers due to improved performance can be 6 billion kWh/year (>$300M). Better cooling, leading to more efficient, higher performance and more reliable power electronics, would save the nation 3 Quad of primary energy in 2030. Just for automotive application, a 10% increase in fuel efficiency for SiC-based power electronics equates to >20 million gallons of fuel savings annually. The proposed EHFµ-Cooler technology ensures the United States maintains its technological lead in high-performance computing and high-power electronics, while at the same time improving the energy efficiency, and as a result reducing energy-related emissions such as greenhouse gases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NUMERICAL INVESTIGATION OF FUEL PROPERTY EFFECTS ON MIXED-MODE COMBUSTION IN A SPARK-IGNITION ENGINE

In the present study, mixed-mode combustion of an E30 fuel in a direct-injection spark-ignition engine is numerically investigated at a fuel-lean operating condition using multidimensional computational fluid dynamics (CFD). A fuel surrogate matching Research Octane Number (RON) and Motor Octane Number (MON) of E30 is first developed using neural network based non-linear regression model. To enable efficient 3D engine simulations, a 164-species skeletal reaction mechanism incorporating NO, chemistry is reducedfrom a detailed chemical kinetic model. A hybrid approach that incorporates the G-equation model for tracking turbulentflame front, and the multi-zone well-stirred reactor model for predicting auto-ignition in the end gas, is employed to account for turbulent combustion interactions in the engine cylinder. Predicted in-cylinder pressure and heat release rate traces agree well with experimental measurements. The proposed modelling approach also captures moderated cyclic variability. Two different types of combustion cycles, corresponding to purely deflagrative and mixed-mode combustion, are observed. In contrast to the purely deflagrative cycles, mixed-mode combustion cycles feature early flame propagation followed by end-gas auto-ignition, leading to two distinctive peaks in heat release rate traces. The positive correlation between mixed-mode combustion cycles and early flame propagation is well captured by simulations. With the validated numerical setup, effects of NOx chemistry on mixed-mode combustion predictions are investigated. NOx chemistry is found to promote auto-ignition through residual gas recirculation, while the deflagrative flame propagation phase remains largely unaffected. Local sensitivity analysis is then performed to understand effects of physical and chemical properties of the fuel, i.e., heat of evaporation (HoV) and laminar flame speed (S-L). An increased HoV tends to suppress end-gas auto-ignition due to increased vaporization cooling, while the impact of HoV on flame propagation is insignificant. In contrast, an increased SL is found to significantly promote both flame propagation and auto-ignition. The promoting effect of SL on auto-ignition is not a direct chemical effect; it is rather caused by an advancement of the combustion phasing, which increases compression heating of the end gas.

detailed chemical kinetics↗

Journal paper

Laser technology is being widely studied for controlled energy deposition for a range of applications, including flow control, ignition, combustion, and diagnostics. The absorption and scattering of laser radiation by liquid droplets in aerosols affects propagation of the laser beam in the atmosphere, while the ignition and combustion characteristics in combustion chambers are influenced by the evaporation rate of the sprayed fuel. In this work, we present a mathematical model built on OpenFOAM for laser heating and evaporation of a single droplet in the diffusion-dominated regime taking into account absorption of the laser radiation, evaporation process, and vapor flow dynamics. The developed solver is validated against available experimental and numerical data for heating and evaporation of ethanol and water droplets. The two main regimes—continuous and pulsed laser heating—are explored. For continuous laser heating, the peak temperature is higher for larger droplets. For pulsed laser heating, when the peak irradiance is close to transition to the boiling regime, the temporal dynamics of the droplet temperature does not depend on the droplet size. With the empirical normalization of time, the dynamics of the droplet shrinkage and cooling are found to be independent of droplet sizes and peak laser intensities.

42 ENGINEERING↗

Volatile aldehyde emissions from “sub-ohm” vaping devices

"Sub-ohm" atomizers with reduced resistance can deliver more power than conventional electronic cigarettes. Typical battery outputs are 100 watts or more. These devices are particularly popular among young users, and can be a significant source of volatile carbonyls in the indoor environment. Emissions from next-generation sub-ohm vaping products were characterized by determining e-liquid consumption and volatile aldehydes emissions for several combinations of popular high-power configurations. Tests explored the effect of dilution air flow (air vent opening), puffing volume, and coil assembly configuration. The mass of liquid consumed per puff increased as the puff volume increased from 50 to 100 mL, then remained relatively constant for larger puff volumes up to 500 mL. This is likely due to mass transfer limitations at the wick and coil assembly, which reduced the vaporization rate at higher puff volumes. Carbonyl emission rates were systematically evaluated using a 0.15 Ω dual coil atomizer as a function of the puffing volume and dilution air flow, adjusted by setting the air vents to either 100% (fully open), 50%, 25%, or 0% (closed). The highest formaldehyde emissions were observed for the lowest puff volume (50 mL) when the vents 31 were closed (48 ng mg-1), opened at 25% (39 ng mg -1 ) and at 50% (32 ng mg -1 ).. By contrast, 50-mL puffs with 100% open vents, and puff volumes >100 mL for any vent aperture, generated formaldehyde yields of 20 ng mg -1 or lower, suggesting that a significant cooling effect resulted in limited carbonyl formation. Considering the effect of the coil resistance when operated at a voltage of 3.8 V, the amount of liquid evaporated per puff decreased as the resistance increased, in the order of 0.15 Ω > 0.25 Ω > 0.6 Ω consistent with decreasing aerosol temperatures measured at the mouthpiece. Three different configurations of 0.15 Ω coils (dual, quadruple and octuple) were evaluated, observing significant variability. No clear trend was found between carbonyl emission rates and coil resistance or configuration, with highest emissions corresponding to a 0.25 Ω dual coil atomizer. Carbonyl emission rates were compared with those determined using the same methodology for conventional e-cigarettes (lower power tank systems), observing overall lower yields for the sub-ohm devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗