Search NASA⌕ Search

SEARCH · Search NASA

Results for “explosives detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A numerical study of shock waves generated through laser ablation of explosives

Shock waves resulting from irradiation of energetic materials with a pulsed ultraviolet laser source have been shown to be an effective indicator for explosives detection. In this study, the features of shock wave propagation are explored theoretically. The initial stage of the shock motion is simulated as a one-dimensional process. As the nonlinear wave expands to form a blast wave, a system of conservation equations, simplified to the Euler equations, is employed to model wave propagation. The Euler equations are solved numerically by the 5th order weighted essentially non-oscillatory finite difference scheme with the time integration carried out using the 3rd order total variation diminishing Runge Kutta method. The numerical results for the shock wave evolution are compared with those obtained from experiments with a meltcast 2,6-dinitrotoluene sample. The calculations lay a theoretical foundation for a recently investigated technique for photoacoustically sensing explosives using a vibrometer.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Passive Infrared Hyperspectral Imaging for Standoff Detection of Tetryl Explosive Residue on a Steel Surface

A commercial imaging FTIR spectrometer that operates between 850 and 1300 cm{sup -1} was used to passively image a galvanized steel plate stained with a residue of the explosive tetryl (2,4,6,N-tetranitro-N-methylaniline). The tetryl was coated onto the plate in a 30 cm diameter spot with an areal dosage of 90 {mu}g tetryl/cm{sup 2}. The stain on the plate was easily detected at standoff distances of 14 and 31 m by examining the hyperspectral data cubes using maximum autocorrelation factors and a slight modification to a generalized least squares target detection algorithm. End-member extraction showed good comparison in a few key bands between the target end-member and laboratory reflectance spectra; however, significant differences were also observed

36 MATERIALS SCIENCE↗

Progress on detection of liquid explosives using ultra-low field MRI

Nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) methods are widely used in medicine, chemistry and industry. Over the past several years there has been increasing interest in performing NMR and MRI in the ultra-low field (ULF) regime, with measurement field strengths of 10-100 microTesla and pre-polarization fields of 30-50 mTesla. The real-time signal-to-noise ratio for such measurements is about 100. Our group at LANL has built and demonstrated the performance of SQUID-based ULF NMR/MRI instrumentation for classification of materials and detection of liquid explosives via their relaxation properties measured at ULF, using T{sub 1}, and T{sub 2}, and T{sub 1} frequency dispersion. We are also beginning to investigate the performance of induction coils as sensors. Here we present recent progress on the applications of ULF MR to the detection of liquid explosives, in imaging and relaxometry.

42 ENGINEERING↗

Mass Spectrometer Containing Multiple Fixed Collectors

A miniature mass spectrometer that incorporates features not typically found in prior mass spectrometers is undergoing development. This mass spectrometer is designed to simultaneously measure the relative concentrations of five gases (H2, He, N2, O2, and Ar) in air, over the relative-concentration range from 10(exp -6) to 1, during a sampling time as short as 1 second. It is intended to serve as a prototype of a product line of easy-to-use, portable, lightweight, highspeed, relatively inexpensive instruments for measuring concentrations of multiple chemical species in such diverse applications as detecting explosive or toxic chemicals in air, monitoring and controlling industrial processes, measuring concentrations of deliberately introduced isotopes in medical and biological investigations, and general environmental monitoring. The heart of this mass spectrometer is an integral combination of a circular cycloidal mass analyzer, multiple fixed ion collectors, and two mass-selective ion sources. By circular cycloidal mass analyzer is meant an analyzer that includes (1) two concentric circular cylindrical electrodes for applying a radial electric field and (2) a magnet arranged to impose a magnetic flux aligned predominantly along the cylindrical axis, so that ions, once accelerated into the annulus between the electrodes, move along circular cycloidal trajectories. As in other mass analyzers, trajectory of each ion is determined by its mass-to-charge ratio, and so ions of different species can be collected simultaneously by collectors (Faraday cups) at different locations intersected by the corresponding trajectories (see figure). Unlike in other mass analyzers, the installation of additional collectors to detect additional species does not necessitate increasing the overall size of the analyzer assembly.

Moskala, Robert↗

The signature of the central engine in the weakest relativistic explosions: GRB 100316D

We present late-time radio and X-ray observations of the nearby sub-energetic gamma-ray burst (GRB)100316D associated with supernova (SN) 2010bh. Our broad-band analysis constrains the explosion properties of GRB 100316D to be intermediate between highly relativistic, collimated GRBs and the spherical, ordinary hydrogen-stripped SNe. We find that ∼10{sup 49} erg is coupled to mildly relativistic (Γ = 1.5-2), quasi-spherical ejecta, expanding into a medium previously shaped by the progenitor mass-loss with a rate of M-dot ∼ 10{sup −5} M{sub ⊙} yr{sup −1} (for an assumed wind density profile and wind velocity v{sub w} = 1000 km s{sup –1}). The kinetic energy profile of the ejecta argues for the presence of a central engine and identifies GRB 100316D as one of the weakest central-engine-driven explosions detected to date. Emission from the central engine is responsible for an excess of soft X-ray radiation that dominates over the standard afterglow at late times (t > 10 days). We connect this phenomenology with the birth of the most rapidly rotating magnetars. Alternatively, accretion onto a newly formed black hole might explain the excess of radiation. However, significant departure from the standard fall-back scenario is required.

79 ASTRONOMY AND ASTROPHYSICS↗

Source Term Estimation of Radioxenon Released from the Fukushima Dai-ichi Nuclear Reactors Using Measured Air Concentrations and Atmospheric Transport Modeling

Systems designed to monitor airborne radionuclides released from underground nuclear explosions detected radioactive fallout from the Fukushima Daiichi nuclear accident in March 2011. Atmospheric transport modeling (ATM) of plumes of noble gases and particulates were performed soon after the accident to determine plausible detection locations of any radioactive releases to the atmosphere. We combine sampling data from multiple International Modeling System (IMS) locations in a new way to estimate the magnitude and time sequence of the releases. Dilution factors from the modeled plume at five different detection locations were combined with 57 atmospheric concentration measurements of 133-Xe taken from March 18 to March 23 to estimate the source term. This approach estimates that 59% of the 1.24×1019 Bq of 133-Xe present in the reactors at the time of the earthquake was released to the atmosphere over a three day period. Source term estimates from combinations of detection sites have lower spread than estimates based on measurements at single detection sites. Sensitivity cases based on data from four or more detection locations bound the source term between 35% and 255% of available xenon inventory.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Impacts of future nuclear power generation on the international monitoring system

Many countries are considering nuclear power as a means of reducing greenhouse gas emissions, and the IAEA (IAEA, 2022) has forecasted nuclear power growth rates up to 224% of the 2021 level by 2050. Nuclear power plants release trace quantities of radioxenon, an inert gas that is also monitored under international agreements as a signature of nuclear weapons tests. To better understand how nuclear energy growth (and resulting Xe emissions) could affect this global nonproliferation architecture, we modeled daily releases of radioxenon isotopes used for nuclear explosion detection in the International Monitoring System (IMS) that is part of the Comprehensive Nuclear Test-Ban Treaty: 131m Xe, 133 Xe, 133m Xe, and 135 Xe to examine the change in the number of radioxenon detections as compared to the 2021 detection levels. If a 40-station IMS network is used, the detections of 133 Xe in 2050 would range from 82% for the low-power scenario to 195% for the high-power scenario, compared to the detections in 2021. If an 80-station IMS network is used, the detections of 133 Xe in 2050 would range from 83% of the 2021 detection rate for the low-power scenario to 209% for the high-power scenario. Essentially no detections of 131m Xe and 133m Xe are expected. The high growth scenario could lead to a six-fold increase in 135 Xe detections, but the total number of detections is still small (on the order of 1 detection per day in the entire network).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Exploring the MeV sky with a combined coded mask and Compton telescope: the Galactic Explorer with a Coded aperture mask Compton telescope (GECCO)

The sky at MeV energies is currently poorly explored. Here we present an innovative mission concept that builds upon the heritage of past and current missions improving the sensitivity and, very importantly, the angular resolution. This consists in combining a Compton telescope and a coded-mask telescope. We delineate the motivation for such a concept and we define the scientific goals for such a mission. The Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO) is a novel concept for a next-generation telescope covering hard X-ray and soft gamma-ray energies. The potential and importance of this approach that bridges the observational gap in the MeV energy range are presented. With the unprecedented angular resolution of the coded mask telescope combined with the sensitive Compton telescope, a mission such as GECCO can disentangle the discrete sources from the truly diffuse emission. Individual Galactic and extragalactic sources are detected. This also allows to understand the gamma-ray Galactic center excess and the Fermi Bubbles, and to trace the low-energy cosmic rays, and their propagation in the Galaxy. Nuclear and annihilation lines are spatially and spectrally resolved from the continuum emission and from sources, addressing the role of low-energy cosmic rays in star formation and galaxy evolution, the origin of the 511 keV positron line, fundamental physics, and the chemical enrichment in the Galaxy. Such an instrument also detects explosive transient gamma-ray sources, which, in turn, enables identifying and studying the astrophysical objects that produce gravitational waves and neutrinos in a multi-messenger context. By looking at a poorly explored energy band it also allows discoveries of new astrophysical phenomena.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonlinear electromagnetic interactions in energetic materials

We study the scattering of electromagnetic waves in anisotropic energetic materials. Nonlinear light-matter interactions in molecular crystals result in frequency-conversion and polarization changes. Applied electromagnetic fields of moderate intensity can induce these nonlinear effects without triggering chemical decomposition, offering a mechanism for the nonionizing identification of explosives. We use molecular-dynamics simulations to compute such two-dimensional THz spectra for planar slabs made of pentaerythritol tetranitrate and ammonium nitrate. Finally, we discuss third-harmonic generation and polarization-conversion processes in such materials. These observed far-field spectral features of the reflected or transmitted light may serve as an alternative tool for standoff explosive detection.

36 MATERIALS SCIENCE↗

Visible/Near-Infrared Hyperspectral Sensing of Solids under Controlled Environmental Conditions

We describe the use of a wind tunnel for conducting controlled passive hyperspectral imaging experiments. Passive techniques are potentially useful for detecting explosives, solid-phase chemicals and other materials of interest from a distance so as to provide operator safety. The Pacific Northwest National Laboratory operates a wind tunnel facility that can generate and circulate artificial atmospheres to control lighting, humidity, temperature, aerosol burdens, and obscurants. We will present recent results describing optimized sensing of solids over tens of meters distance using both visible and near-infrared cameras, as well as the effects of certain environmental parameters on data retrieval.

99 GENERAL AND MISCELLANEOUS↗

Fiber Delivery of mid-IR lasers

Fiber optics for the visible to near infrared (NIR) wavelength regimes (i.e. = 0.42 {mu}m) have proven to be extremely useful for a myriad of applications such as telecommunications, illumination, and sensors because they enable convenient, compact, and remote delivery of laser beams. Similarly, there is a need for fiber optics operating at longer wavelengths. For example, systems operating in the mid-IR regime (i.e., = 314 {mu}m) are being developed to detect trace molecular species with far-reaching applications, such as detecting explosives on surfaces, pollutants in the environment, and biomarkers in the breath of a patient. Furthermore, with the increasing availability of quantum cascade lasers (QCLs) which are semiconductor lasers that operate in the mid-IR regime additional uses are rapidly being developed. Here, we describe the development of hollow-core fibers for delivery of high-quality mid-IR laser beams across a broad spectral range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle/Ray Interaction Simulation Manager (PRISM) Assessment Report

The Particle/Ray Interaction Simulation Manager (PRISM) is a software tool developed by Triple Ring Technologies (TRT), http://www.tripleringtech.com/, under a Small Business Innovation Research Award from the Department of Homeland Security (DHS) to investigate the utility of simulations in X-ray-based explosive detection systems. The PRISM tool is intended to provide a standardized and intuitive user interface to control and configure realistic simulations of X-ray imaging systems. It includes a command-line interface that enables the user to configure simulated X-ray radiography and computed tomography (CT) systems. It allows the import of computer-aided design (CAD) models of objects and it supports Monte Carlo simulation engines such as GEANT4. PRISM is designed to simulate realistic X-ray projection images including scatter, noise, and various detector effects such as quantum efficiency, lag, and veiling glare. At the request of DHS, the authors assessed PRISM’s capabilities to simulate data generated by a Micro-CT test-bed system (MCT-TB) housed at the Lawrence Livermore National Laboratory (LLNL). This document describes the results of that assessment.

42 ENGINEERING↗

Dose Measurement on Microfocus Computed Tomography Scanner

This Standard Operating Procedure (SOP) outlines the steps for measuring dose in x-ray computed tomography (CT) scans [1] on the MicroCT (MCT) system at the High Explosives Application Facility (HEAF) and other systems relevant to the Livermore Explosives Detection Program (LEDP). These systems include: the DHS LLNL MCT in HEAF, aka HEAFCAT, DHS LLNL MCT Testbed (TB) in B327, and the MCTs at TRMG, HEX2, HMEX, CBX, and IPMO, as described in Section 4.

42 ENGINEERING↗

General seismology

Seismological instrumentation, earthquake and nuclear explosion detection, and engineering construction applications

RECORDING INSTRUMENT↗

Miniature Reversal Electron-Attachment Detector

Miniature reversal electron-attachment detector (miniREAD) enables direct injection of air or vapor at atmospheric pressure from monitored area into mass-spectrometric instrument to detect explosives, narcotics, or other substances, vapors of which suspected of being present in low concentrations. In comparison with older reversal electron-attachment detector, miniREAD simpler in design; more rugged; and easier to build, repair, and maintain. In addition, probably more sensitive.

Chutjian, Ara↗