SEARCH · Search NASA
Results for “false data”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration
The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time
Forced Power Systems Oscillations Due to Cyberattacks: Threats, Detection and Partial Mitigation
Forced oscillations in power systems can be caused by misconfigured controllers at generator stations. They can also be caused by cyberattacks against the exciters or governors. This paper explores the effects of forced oscillations from cyberattacks on generator excitation and governor systems and the effectiveness of a novel control system for a static var compensator in mitigating those oscillations to enhance transmission system resilience. A brief overview of oscillations, especially forced oscillations, within power systems is presented, along with an overview of cyberattacks on power systems. This paper also examines and implements FACTS devices to partially mitigate the forced oscillations created by cyberattacks by reducing the magnitude of the oscillations caused by the attack. The proposed approach is more effective against attacks targeting exciters.
Attack Power System State Estimation by Implicitly Learning the Underlying Models
Not Available
Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP-SAIL)
The Characterization of Orography-Influenced Riming and Secondary Ice Production and Their Effects on Precipitation Rates Using Radar Polarimetry and Doppler Spectra (CORSIPP) project was conducted to help improve the understanding of precipitation formation in orographically influenced terrain. Special focus is put on the two processes of riming and secondary ice production and their external drivers. Two instruments, a polarimetric W-band simultaneous transmission simultaneous reception (STSR) Doppler cloud radar manufactured by Radiometer Physics GmbH (RPG, instrument type RPG-FMCW-94-DP), from now on named LIMRAD94, and the video in situ snowfall sensor (VISSS), were deployed at the U. S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) site in Gothic, Colorado between November 2022 and June 2023 during the second SAIL winter. Note that the exact dates of data availability differ between the instruments. Both instruments arrived at Gothic on November 2, 2022, 09:20 local time. VISSS, described by Maahn et al., is equipped with two camera systems with telecentric lenses. The two cameras are at a 90° angle to each other. This configuration allows for size-independent measurements by capturing images of hydrometeors from two sides at a high frame rate of 250 Hz. With a minimum detection size of 200 μm, VISSS provides valuable insights into particle size, number, shape, complexity, and fall velocity. The VISSS was deployed on the grassland next to the ARM facility with the amazing help of the ARM employees on site. The setup started on November 2, 2022, and was finished on November 5, 2022, without major problems. VISSS measurements were started on November 6, 2022. LIMRAD94 was installed on a scaffolding platform near Orehouse (Gothic) on November 9, 2022, with the great help of RMBL staff. LIMRAD94 was mounted on a cold temperature scanner prototype. After a short test of the setup on November 9, 2022, the digital control of the scanner elevation stopped working for (at that time) unknown reasons. All attempts to resolve the problem failed. This malfunction made it impossible to operate LIMRAD94 in scanning mode. The scanner was then manually moved to zenith pointing mode and between November 10 and November 15, 2022, vertical observations for polarimetric calibration were performed. On November 15, 2022, after the polarimetric calibration was applied, the scanner was manually moved to 40° elevation with azimuthal view towards the Ka-band ARM Zenith Radar (KAZR) and measurements were continued at constant elevation. Investigation of the scanner malfunction on February 6, 2023, by Benn Schmatz revealed a disengagement between the cogwheel of the elevation motor and the cogwheel moving the scanner in elevation. This mechanical issue was temporarily solved by re-engaging the cogwheels. This made the scanner operational again for about four weeks, until mechanical force disengaged the cogwheels again on March 15, 2023. This repeated scanner failure remained undetected for about three weeks until April 8, 2023; during this time the scanner was stuck at 72° elevation. However, the radar software continued to produce data files falsely indicating that the scanner was still operational. After the scanner failure was noticed, scanning was stopped again, and we returned to constant elevation measurements. On May 15, 2023, the cogwheels of the elevation motor were secured with additional screws sent by the manufacturer. At some point in May, the cogwheels of the azimuth motor were also disengaged by mechanical force, which still allowed for range height indicator (RHI) but no plan position indicator (PPI) scans in the last weeks of the campaign. The azimuth motor was repaired in Germany after the end of the campaign. Throughout the campaign, RMBL and ARM staff kept the radar and the VISSS free of snow.
Visualizing Parallel Computer System Performance
Parallel computer systems are among the most complex of man's creations, making satisfactory performance characterization difficult. Despite this complexity, there are strong, indeed, almost irresistible, incentives to quantify parallel system performance using a single metric. The fallacy lies in succumbing to such temptations. A complete performance characterization requires not only an analysis of the system's constituent levels, it also requires both static and dynamic characterizations. Static or average behavior analysis may mask transients that dramatically alter system performance. Although the human visual system is remarkedly adept at interpreting and identifying anomalies in false color data, the importance of dynamic, visual scientific data presentation has only recently been recognized Large, complex parallel system pose equally vexing performance interpretation problems. Data from hardware and software performance monitors must be presented in ways that emphasize important events while eluding irrelevant details. Design approaches and tools for performance visualization are the subject of this paper.
Improved Measurement of Coherence in Presence of Instrument Noise
A method for correcting measured coherence spectra for the effect of incoherent instrument noise has been developed and demonstrated. Coherence measurements are widely used in engineering and science to determine the extent to which two signals are alike. The signals may come from two different sources or from the same source at different times. The coherence of time-lagged signals from a single source is an excellent indication of the effective lifetime of the signal components as a function of their frequency. Unfortunately, incoherent instrument noise will bias the measurement to lower values and may lead the user of the data to false conclusions about the longevity of significant features. The new method may be used whenever both the signal and noise power spectra are known and the noise is incoherent both with the signal and with itself at the applicable time delays. It provides a corrected coherence spectrum given the measured coherence and power spectra. For powerlaw signal spectra and instrumental white noise, the correction formula takes a particularly simple and explicit form. Since many geophysical signals exhibit powerlaw behavior and most instrument noise spectra approach white noise, the simplified form should be widely applicable in meteorology, oceanography, geology, and planetary geophysics.
Age-dating volcanic and alluvial surfaces with multipolarization data
A false-color multipolarization version of one of the images of Owens Valley area acquired by the JPL Synthetic Aperture Radar (SAR) is given. A geologic map of the alluvial fans there (Gillespie, 1982) is also given for comparison. In general, brightness in the multipolarization images can be seen to be inversely proportional to the age of the surfaces. A more detailed investigation of the relationship between backscatter and age of the surfaces was undertaken with calibrated aircraft SAR data. The quantitative relationship between backscatter coefficient and age for the three polarizations is shown. The straight lines connecting the measured data points imply a steady-state process, although the process or processes leading to this relationship may have operated at rates that varied with climate fluctuations, such as the glacial ages. It is expected that the relationship between radar brightness and age is a consistent one, and that with the wider availability of calibrated radar backscatter data, these relationships can be less well-known areas. The effect of variable such as past climate fluctuations, tectonic disturbance, and rock type must be understood before extension beyond the Mojave Desert region can be attempted.
False lock performance in polarity-type Costas receivers in the presence of periodic data patterns
The authors address the false-lock performance of receivers which use polarity-type Costas loops for the carrier recovery of unbalanced quadrature phase-shift keyed (QPSK), asynchronous QPSK or binary PSK (BPSK) signals in the presence of periodic data patterns. The potential false-lock frequencies are first identified. Expressions for both true-lock and false-lock components are also derived, thereby allowing numerical evaluation of various key parameters for cases of practical interest.
MIJAMP
Here, we develop MIJAMP (MIJAMP Is Just A MethylBED Parser), a software package that was developed to discover methylated motifs from the output of ONT’s Modkit or other data in the methylBED format. MIJAMP employs a human-driven refinement strategy that empirically validates all motifs against genome-wide methylation data, thus eliminating false, under-, or overexplained motifs. MIJAMP can also report methylation data on a specific, user-defined motif.
False lock in quadriphase receivers with unequal I- and Q-channel data rates
Results are presented concerning the noise-free false-lock problem in quadriphase receivers with unequal I-channel and Q-channel data rates. It is shown that false lock may occur when the incoming carrier frequency and the loop VCO (voltage-controlled oscillator) frequency differ by an amount that is a linear combination of a quarter of I-channel and Q-channel data rates. General expressions for the false-lock performance of quadriphase receivers are given for random as well as periodic data patterns. Specific closed-form expressions for the false-lock margin are are derived when the arm filters of the quadriphase receivers are single-pole Butterworth filters, and the format of the random data is NRZ (nonreturn-to-zero). Numerical evaluations of false-lock margin as a function of the product of 3-dB arm-filter bandwidth and symbol duration are carried out for random data using various arm filters and for different periodic I-chanel and Q-channel data patterns.
Windowing artefacts likely account for recent claimed detection of oscillating cosmic scale factor
ABSTRACT Using the Pantheon data set of Type Ia supernovae, a recent publication (R20 in this work) reports a 2σ detection of oscillations in the expansion history of the Universe. The study conducted by R20 is wholly worthwhile. However, we demonstrate that there is a $\gt 10{{\ \rm per\ cent}}$ chance of statistical fluctuations in the Pantheon data producing a false oscillatory signal larger than the oscillatory signal that R20 report. Their results are a less than 2σ detection. Applying the R20 methodology to simulated Pantheon data, we determine that these oscillations could arise due to analysis artefacts. The uneven spacing of Type Ia supernovae in redshift space and the complicated analysis method of R20 impose a structured throughput function. When analysed with the R20 prescription, about $11{{\ \rm per\ cent}}$ of artificial ΛCDM data sets produce a stronger oscillatory signal than the actual Pantheon data. Our results underscore the importance of understanding the false ‘signals’ that can be introduced by complicated data analyses.
Bit Grooming: statistically accurate precision-preserving quantization with compression, evaluated in the netCDF Operators (NCO, v4.4.8+)
Abstract. Geoscientific models and measurements generate false precision (scientifically meaningless data bits) that wastes storage space. False precision can mislead (by implying noise is signal) and be scientifically pointless, especially for measurements. By contrast, lossy compression can be both economical (save space) and heuristic (clarify data limitations) without compromising the scientific integrity of data. Data quantization can thus be appropriate regardless of whether space limitations are a concern. We introduce, implement, and characterize a new lossy compression scheme suitable for IEEE floating-point data. Our new Bit Grooming algorithm alternately shaves (to zero) and sets (to one) the least significant bits of consecutive values to preserve a desired precision. This is a symmetric, two-sided variant of an algorithm sometimes called Bit Shaving that quantizes values solely by zeroing bits. Our variation eliminates the artificial low bias produced by always zeroing bits, and makes Bit Grooming more suitable for arrays and multi-dimensional fields whose mean statistics are important. Bit Grooming relies on standard lossless compression to achieve the actual reduction in storage space, so we tested Bit Grooming by applying the DEFLATE compression algorithm to bit-groomed and full-precision climate data stored in netCDF3, netCDF4, HDF4, and HDF5 formats. Bit Grooming reduces the storage space required by initially uncompressed and compressed climate data by 25–80 and 5–65 %, respectively, for single-precision values (the most common case for climate data) quantized to retain 1–5 decimal digits of precision. The potential reduction is greater for double-precision datasets. When used aggressively (i.e., preserving only 1–2 digits), Bit Grooming produces storage reductions comparable to other quantization techniques such as Linear Packing. Unlike Linear Packing, whose guaranteed precision rapidly degrades within the relatively narrow dynamic range of values that it can compress, Bit Grooming guarantees the specified precision throughout the full floating-point range. Data quantization by Bit Grooming is irreversible (i.e., lossy) yet transparent, meaning that no extra processing is required by data users/readers. Hence Bit Grooming can easily reduce data storage volume without sacrificing scientific precision or imposing extra burdens on users.
Toward artifact-free data in Hadamard transform-based double multiplexing of ion mobility-Orbitrap mass spectrometry
The integration of ion mobility spectrometry (IMS) with trap-based mass spectrometer (MS) such as Orbitrap using the dual gate approach suffers from low duty cycle. Efforts to improve the duty cycle involve the utilization of Hadamard transform based double multiplexing which significantly improve the signal to noise ratio and duty cycle of the ion mobility – Orbitrap mass spectrometry (IM – Orbitrap MS) platform. However, significant fluctuations in ion intensity and the temporal shifts in the encoded data give rise to artifacts and noise in the demultiplexed data which significantly reduce the data quality and negate the benefits of multiplexing. We propose a new approach that identifies the true IM peaks and helps in eliminating the artifacts in the demultiplexed data leading to a decrease in false positives in subsequent data processing. The algorithm takes an analytical approach to first identify the position of the IM peak in the temporal domain, and then demultiplex and identify the true data making it easier for subsequent data processing. After the application of the algorithm, the quality of the IM-Orbitrap MS measurements was greatly improved because of the reduction in artifacts.
Application of Principal Component Analysis to Electrochemical Reprocessing PM and NMAC
In this report, data from an electrorefiner (ER) for nuclear fuel reprocessing is evaluated for process monitoring (PM) conclusions. This data comes from tests performed at the Idaho National Laboratory in 2022. Multivariate approaches utilizing methods of Principal Component Analysis (PCA) is applied. This is based off established work in process monitoring for fault detection in industrial facilities. This report will discuss the background, methods, and results of the application and some of the conclusions and applications that can be drawn from them. PCA is applied to two different electrorefiner (ER) operations that occurred at Idaho National Laboratory between August and October 2022. The first operation occurred with little incident while the second had several noted faults in the equipment in operational logs. The data from the first run was used to train the data for “normal” operations and applied to both sets of data to determine when operations were in an “off-normal” condition and identify where the fault occurs through PCA. PCA was able to identify off-normal events and identify the cause for off-normal operations. These identified off-normal events matched with the events and their causes in the operational logs. However, small amounts of variance in the data led to false detection of “off-normal” events. Thus, careful selection of training data and a-posteriori conclusions based off operator assessments will both be required for application of PCA to PM applications. This work demonstrated that multivariate approaches and latent variables are applicable to pyroprocessing PM applications and can be further expanded in future work as quality variables such as salt concentration from sensors and sampling become available.
ASTROMETRY.NET: BLIND ASTROMETRIC CALIBRATION OF ARBITRARY ASTRONOMICAL IMAGES
We have built a reliable and robust system that takes as input an astronomical image, and returns as output the pointing, scale, and orientation of that image (the astrometric calibration or World Coordinate System information). The system requires no first guess, and works with the information in the image pixels alone; that is, the problem is a generalization of the 'lost in space' problem in which nothing-not even the image scale-is known. After robust source detection is performed in the input image, asterisms (sets of four or five stars) are geometrically hashed and compared to pre-indexed hashes to generate hypotheses about the astrometric calibration. A hypothesis is only accepted as true if it passes a Bayesian decision theory test against a null hypothesis. With indices built from the USNO-B catalog and designed for uniformity of coverage and redundancy, the success rate is >99.9% for contemporary near-ultraviolet and visual imaging survey data, with no false positives. The failure rate is consistent with the incompleteness of the USNO-B catalog; augmentation with indices built from the Two Micron All Sky Survey catalog brings the completeness to 100% with no false positives. We are using this system to generate consistent and standards-compliant meta-data for digital and digitized imaging from plate repositories, automated observatories, individual scientific investigators, and hobbyists. This is the first step in a program of making it possible to trust calibration meta-data for astronomical data of arbitrary provenance.
The influence of false color infrared display on training field identification
The overall success of large-scale crop inventories of agricultural regions using Landsat multispectral scanner data is highly dependent upon the labeling of training data by analyst/photointerpreters. The principal analyst tool in labeling training data is a false color infrared composite of Landsat bands 4, 5, and 7. In this paper, this color display is investigated and its influence upon classification errors is partially determined.