Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Time evolution and asymmetry of a laser produced blast wave

Studies of a blast wave produced from carbon rods and plastic spheres in an argon background gas have been conducted using the Vulcan laser at the Rutherford Appleton Laboratory. A laser of 1500 J was focused onto these targets, and rear-side observations of an emission front were recorded using a fast-framing camera. The emission front is asymmetrical in shape and tends to a more symmetrical shape as it progresses due to the production of a second shock wave later in time, which pushes out the front of the blast wave. Plastic spheres produce faster blast waves, and the breakthrough of the second shock is visible before the shock stalls. The results are presented to demonstrate this trend, and similar evolution dynamics of experimental and simulation data from the FLASH radiation-hydrodynamics code are observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Verification of Doppler coherence imaging for 2D ion velocity measurements on DIII-D

Coherence Imaging Spectroscopy (CIS) has emerged as a powerful tool for investigating complex ion phenomena in the boundary of magnetically confined plasma devices. The combination of Fourier-transform interferometry and high-resolution fast-framing cameras has made it possible to make sensitive velocity measurements that are also spatially resolved. However, this sensitivity makes the diagnostic vulnerable to environmental effects including thermal drifts, vibration, and magnetic fields that can influence the velocity measurement. Additionally, the ability to provide an absolute calibration for these geometries can be impacted by differences in the light-collection geometry between the plasma and reference light source, spectral impurities, and the presence of thin-films on in-vessel optics. This work discusses the mitigation of these effects and demonstration that environmental effects result in less than 0.5 km/s error on the DIII-D CIS systems. A diagnostic comparison is used to demonstrate agreement between CIS and traditional spectroscopy once tomographic artifacts are accounted for.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of shock-front separation in multi-ion-species collisional plasma shocks

We observe shock-front separation and species-dependent shock widths in multi-ion-species collisional plasma shocks, which are produced by obliquely merging plasma jets of a He/Ar mixture (97% He and 3% Ar by initial number density) on the plasma liner experiment. Visible plasma emission near the He-I 587.6-nm and Ar-II 476.5–514.5-nm lines is simultaneously recorded by splitting a single visible image of the shock into two different fast-framing cameras with different narrow bandpass filters (589 ± 5 nm for observing the He-I line and 500 ± 25 nm for the Ar-II lines). For conditions in these experiments (pre-shock ion and electron densities ≈5×10 14 cm –3 , ion and electron temperatures of ≈2.2 eV, and relative plasma-merging speed of 22 km/s), the observationally inferred magnitude of He/Ar shock-front separation and the shock widths themselves are <1 cm, which correspond to ~50 post-shock thermal ion–ion mean free paths. These experimental length scales are in reasonable qualitative and quantitative agreement with results from 1D multi-fluid simulations using the CHICAGO code. However, we note there are differences between the experimentally inferred and simulation-predicted ionization states and line emission intensities, particularly in the post-shock region. Overall, the experimental and simulation results are consistent with theoretical predictions that the lighter He ions diffuse farther ahead within the overall shock front than the heavier Ar ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatio-temporal ion temperature and velocity measurements in a Z pinch using fast-framing spectroscopy

Ion Doppler spectroscopy (IDS) is a diagnostic technique that measures plasma ion temperature and velocity without perturbing the plasma with a physical probe. The ZaP-HD Flow Z-Pinch Experiment at the University of Washington uses this technique to resolve radial temperature and velocity profiles of a Z-pinch plasma. The pinch lifetime is approximately 100 ms, therefore diagnostics capable of sub-microsecond resolution are required to measure the evolution of temperature and velocity profiles. The previous IDS diagnostic system was only capable of collecting a single measurement during a plasma pulse. Here, an improved system has been developed to measure radially-resolved ion temperature and velocity for the entire Z-pinch lifetime. A Kirana 05M ultra-fast framing camera and SIL ultraviolet intensifier are used to record up to 100 spectra per plasma pulse. The temperature is computed from Doppler broadening of the carbon-III (229.687 nm) impurity ion radiation and the velocity from the Doppler shift of carbon-III. Measurements are able to resolve the evolution of the ion temperature and velocity over the course of a plasma pulse. The diagnostic has significantly reduced the number of pulses required and provides a more coherent measurement of plasma dynamics than the previous system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle balance of deuterium during deuterium shattered pellet injection shutdown in DIII-D

A particle balance analysis was conducted during a deuterium (D 2 ) shattered pellet injection-induced plasma shutdown on the DIII-D tokamak to determine why less than 20% of the pellet material is assimilated into the core plasma by the mid-current quench (CQ). Initially, most of the D 2 is injected as frozen shards and ionized upon entering the vessel. During the thermal quench, ionized particles move to the divertors and subsequently to the center post (CP) walls, where they rapidly recycle and partially accumulate as neutrals without assimilating into the core plasma. In contrast, the particle flux to the outer midplane walls is negligible, despite being accompanied by hot plasma with electron temperatures exceeding 100 eV. During mid-CQ, volume recombination effects, although not large enough to impact overall particle balance, were significant enough to require accounting for accurate interpretation of fast-framing camera D-alpha signals and the estimation of the CP wall particle flux. In addition, toroidal asymmetries, observed in measurements of toroidal electron density perturbations and the phase of magnetohydrodynamic modes, are present throughout the shutdown and can account for a discrepancy in the assimilation rate for up to 50% of the observed D 2 particle inventory. These sources and sinks of particles and fluxes were identified using absolutely calibrated D-alpha brightness and Langmuir probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axisymmetric oscillations at L–H transitions in JET: M-mode

L to H transition studies at JET have revealed an n = 0, m = 1 magnetic oscillation starting immediately at the L to H transition (called M-mode for brevity). While the magnetic oscillation is present a weak ELM-less H-mode regime is obtained, with a clear increase of density and a weak electron temperature pedestal. It is an intermediate state between L and H-mode. In ICRH heated plasmas or low density NBI plasmas the magnetic mode and the pedestal can remain steady (with small oscillations) for the duration of the heating phase, of order 10 s or more. The axisymmetric magnetic oscillation has period ~0.5–2 ms, and poloidal mode number m = 1: it looks like a pedestal localised up/down oscillation, although it is clearly a natural oscillation of the plasma, not driven by the position control system. Electron cyclotron emission, interferometry, reflectometry and fast Li beam measurements locate the mode in the pedestal region. Dα, fast infrared camera and Langmuir probe measurements show that the mode modulates heat and particle fluxes to the target. The mode frequency appears to scale with the poloidal Alfvén velocity, and not with sound speed (i.e. it is not a geodesic acoustic mode). A heuristic model is proposed for the frequency scaling of the mode. We discuss the relationship between the M-mode and other related observations near the L–H transition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental studies and simulations of hydrogen pellet ablation in the stellarator TJ-II

Plasma core fuelling is a key issue for the development of steady-state scenarios in large magnetically-confined fusion devices, in particular for helical-type machines. At present, cryogenic pellet injection is the most promising technique for efficient fuelling. Here, pellet ablation and fuelling efficiency experiments, using a compact pellet injector, are carried out in electron cyclotron resonance and neutral beam injection heated plasmas of the stellarator TJ-II. Ablation profiles are reconstructed from light emissions collected by silicon photodiodes and a fast-frame camera system, under the assumptions that such emissions are loosely related to the ablation rate and that pellet radial acceleration is negligible. In addition, pellet particle deposition and fuelling efficiency are determined using density profiles provided by a Thomson scattering system. Furthermore, experimental results are compared with ablation and deposition profiles provided by the HPI2 pellet code, which is adapted here for the stellarators Wendelstein 7-X (W7-X) and TJ-II. Finally, the HPI2 code is used to simulate ablation and deposition profiles for pellets of different sizes and velocities injected into relevant W7-X plasma scenarios, while estimating the plasmoid drift and the fuelling efficiency of injections made from two W7-X ports.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-fidelity simultaneous detection of a trapped-ion qubit register

Qubit state detection is an important part of a quantum computation. As number of qubits in a quantum register increases, it is necessary to maintain high fidelity detection to accurately measure the multi-qubit state. Here we present experimental demonstration of high-fidelity detection of a multi-qubit trapped ion register with average single qubit detection error of 4.2(1.5) ppm and a 4-qubit state detection error of 17(2) ppm, limited by the decay lifetime of the qubit, using a novel single-photon-sensitive camera with fast data collection, excellent temporal and spatial resolution, and low instrumental crosstalk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure retrieval from four-dimensional scanning transmission electron microscopy: Statistical analysis of potential pitfalls in high-dimensional data

Four-dimensional (4D) scanning transmission electron microscopy is one of the most rapidly growing modes of electron microscopy imaging. The advent of fast pixelated cameras and the associated data infrastructure have greatly accelerated this process. Yet conversion of the 4D datasets into physically meaningful structure images in real space remains an open issue. In this work, we demonstrate that it is possible to systematically create filters that will affect the apparent resolution or even qualitative features of the real-space structure image, reconstructing artificially generated patterns. As initial efforts, we explore statistical model selection algorithms, aiming for robustness and reliability of estimated filters. This statistical model selection analysis demonstrates the need for regularization and cross validation of inversion methods to robustly recover structure from high-dimensional diffraction datasets.

36 MATERIALS SCIENCE↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast time-of-flight camera based surface registration for radiotherapy patient positioning

Purpose: This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. Methods: A novel preregistration algorithm, based on translation and rotation-invariant features representing surface structures, was developed. Using these features, corresponding three-dimensional points were computed in order to determine initial registration parameters. These parameters became a robust input to an accelerated version of the iterative closest point (ICP) algorithm for the fine-tuning of the registration result. Distance calibration and Kalman filtering were used to compensate for ToF-camera dependent noise. Additionally, the advantage of using the feature based preregistration over an ''ICP only'' strategy was evaluated, as well as the robustness of the rigid-transformation-based method to deformation. Results: The proposed surface registration method was validated using phantom data. A mean target registration error (TRE) for translations and rotations of 1.62 {+-} 1.08 mm and 0.07 deg. {+-} 0.05 deg., respectively, was achieved. There was a temporal delay of about 65 ms in the registration output, which can be seen as negligible considering the dynamics of biological systems. Feature based preregistration allowed for accurate and robust registrations even at very large initial displacements. Deformations affected the accuracy of the results, necessitating particular care in cases of deformed surfaces. Conclusions: The proposed solution is able to solve surface registration problems with an accuracy suitable for radiotherapy cases where external surfaces offer primary or complementary information to patient positioning. The system shows promising dynamic properties for its use in gating/tracking applications. The overall system is competitive with commonly-used surface registration technologies. Its main benefit is the usage of a cost-effective off-the-shelf technology for surface acquisition. Further strategies to improve the registration accuracy are under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-158: Experimental Investigation of Proton Radiography Based On Time-Resolved Dose Measurements

Purpose: To use proton radiography for i) in-vivo range verification of the brain fields of medulloblastoma patients in order to reduce the exit dose to the cranial skin and thus the risk of permanent alopecia; ii) for performing patient specific optimization of the calibration from CT-Hounsfield units to proton relative stopping power in order to minimize uncertainties of proton rang Methods: We developed and tested a prototype proton radiography system based on a single-plane scintillation screen coupled with a fast CCD camera (1ms sampling rate, 0.29x0.29 mm{sup 2} pixel size, 30×30 cm{sup 2} field of view). The method is based on the principle that, for passively scattered beams, the radiological depth of any point in the plateau of a spread-out Bragg-Peak (SOBP) can be inferred from the time-pattern of the dose rate measurements. We performed detector characterization measurements using complex-shape homogeneous phantoms and an Alderson phanto Results: Detector characterization tests confirmed the robustness of the technique. The results of the phantom measurements are encouraging in terms of achievable accuracy of the water equivalent thickness. A technique to minimize the degradation of spatial resolution due to multiple Coulomb scattering is discussed. Our novel radiographic technique is rapid (100 ms) and simultaneous over the whole field. The dose required to produce one radiograph, with the current settings, is ∼3 cG Conclusion: The results obtained with this simple and innovative radiography method are promising and motivate further development of technique. The system requires only a single-plane 2D dosimeter and it uses the clinical beam for a fraction of second with low dose to the patient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical observation of shock waves and cavitation bubbles in high intensity laser-induced shock processes

We report an experimental study of the temporal and spatial dynamics of shock waves, cavitation bubbles, and sound waves generated in water during laser shock processing by single Nd:YAG laser pulses of nanosecond duration. A fast ICCD camera (2 ns gate time) was employed to record false schlieren photographs, schlieren photographs, and Mach-Zehnder interferograms of the zone surrounding the laser spot site on the target, an aluminum alloy sample. We recorded hemispherical shock fronts, cylindrical shock fronts, plane shock fronts, cavitation bubbles, and phase disturbance tracks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond laser electronic excitation tagging for quantitative velocity imaging in air

Time-accurate velocity measurements in unseeded air are made by tagging nitrogen with a femtosecond-duration laser pulse and monitoring the displacement of the molecules with a time-delayed, fast-gated camera. Centimeter-long lines are written through the focal region of a {approx}1 mJ, 810 nm laser and are produced by nonlinear excitation and dissociation of nitrogen. Negligible heating is associated with this interaction. The emission arises from recombining nitrogen atoms and lasts for tens of microseconds in natural air. It falls into the 560 to 660 nm spectral region and consists of multiple spectral lines associated with first positive nitrogen transitions. The feasibility of this concept is demonstrated with lines written across a free jet, yielding instantaneous and averaged velocity profiles. The use of high-intensity femtosecond pulses for flow tagging allows the accurate determination of velocity profiles with a single laser system and camera.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Can YAG screen accept LEReC bunch train?

LEReC RF diagnostic beamline is supposed to accept 250 us long pulse trains of 1.6 MeV – 2.6 MeV (kinetic energy) electrons. This beamline is equipped with YAG profile monitor. Since we are interested in observing only the last macro bunch in the train, one of the possibilities is to install a fast kicker and a dedicated dump upstream of the YAG screen (and related diagnostics equipment). This approach is expensive and challenging from engineering point of view. Another possibility is to send the whole pulse train to the YAG screen and to use a fast gated camera (such as Imperex B0610 with trigger jitter under 60ns) to observe the image from the last pulse only. In this paper we study the feasibility of the last approach.

43 PARTICLE ACCELERATORS↗

LA-43-S-CT Post Shot

LA-43-S-CT was conducted on 12/14/15to verify the performance of the HE/Armature system intended for use in a new configuration of Ranchero Flux Compression Generators (FCGs). Subsystem tests preceded this experiment, and a synopsis of the issues explored in these is presented. The system was viewed by two fast framing cameras, an array of PDV probes, and an electronic streak camera that provide very good time and space resolution for motion of the armature during expansion. The test is described in very good detail, and the result is that the armature system is adequate for use in the Ranchero 43-S system for future physics tests.

Ranchero↗

Time Delay from Corona to Breakdown

This report describes measurements of the time delay between the onset of corona and complete electrical breakdown between a point and a plane in dry air near atmospheric pressure as a function of the distance between the point and the plane. The large variation in these time delays is representative of the stochastic nature of electrical breakdown and the many possible phenomena that occur between the initiation and completion of electrical breakdown, including initiation without complete electrical breakdown. The purpose of this work is to provide data which will be accurately modeled when a model contains the appropriate mechanisms with the proper priorities to describe this fundamental electrical breakdown configuration. The acquisition of these measurements completes a level three milestone for the WSEAT program which sponsors this research. Also included in this report is a description of our plans to “automate” the experimental procedure, protect the high sensitivity fast-gated camera, and add diagnostics and new experimental techniques to the test facility. This will provide measurements of the time delay distributions with improved statistics and additional experimental information about the processes that occur during electrical breakdown.

42 ENGINEERING↗

Evaluation of a fiber-coupled x-ray diffraction detector for dynamic compression experiments

The long-term x-ray diffraction (XRD) detector scheme compatible with Z-containment experiments will involve conversion of the diffracted x-rays to optical light, which will be transported away from the Z-Dynamic Materials Properties (DMP) load and detected on a fast-gated camera. In this so-called DIffraction SCintillator Optic (DISCO) scheme , the scintillator is coupled to a long, coherent imaging fiber bundle using a custom lens system with high numerical aperture. In addition, the DISCO diagnostic incorporates time-gating to allow measurement only during the short time window of the x-ray pulse in which XRD occurs, thereby significantly reducing unwanted background generated by the Z-DMP load. Dynamic compression experiments were performed at the Chama target chamber to evaluate the DISCO diagnostic . Specifically, a Zr sample was laser-shocked with the Chaco laser while the Z-Beamlet (ZBL) laser was used to generate x-rays, which enabled time-gated 6.7-keV XRD patterns from the compressed Zr sample to be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗