Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

RHEGAL: Resistive heating gas enclosure loadframe for in situ neutron scattering

In situ neutron scattering is a powerful tool to reveal materials atomic structural response such as phase transformation, lattice straining, and texture under external stimuli. The advent of a high flux neutron source such as the Spallation Neutron Source (SNS) allows fast measurement in even non-equilibrium conditions, i.e., phase transformation in steels. However, the commercial fast heating apparatus such as commercial physical simulation equipment is not designed for in situ neutron scattering, which limits its application to in situ materials research by using neutrons. Here we present a resistive heating gas enclosure loadframe (RHEGAL) for non-equilibrium phase transformation studies by using in situ neutron scattering, which takes the advantage of high flux neutron sources like SNS. RHEGAL enables fast resistive heating of metal samples to 1200 °C at a rate up to 60 °C/s in an inert atmosphere. It provides both horizontal and vertical positions for scattering optimization. The mechanical loading capability also allows in situ high temperature tension above the oxidation temperature limit. The optimized translucent neutron scattering window by silicon allows both reflection and transmission measurements, making this equipment applicable for neutron diffraction, small angle scattering, and imaging. Furthermore, to demonstrate the fast heating capability, the phase transformations of an example of advanced high strength steel heated at 3 °C/s and 30 °C/s were measured with the VULCAN engineering diffractometer, and the different phase transformation kinetics by neutron diffraction were presented.

47 OTHER INSTRUMENTATION↗

PtychoNet: Fast and High Quality Phase Retrieval for Ptychography

Ptychography is a coherent diffractive imaging method that captures multiple diffraction patterns of a sample with a set of shifted localized illuminations (“probes”). The reconstruction problem, known as “phase retrieval”, is typically solved by iterative algorithms. In this paper, we propose PtychoNet, a deep learning based method to perform phase retrieval for ptychography in a non-iterative manner. We devise a generative network to encode a full ptychography scan, reverse the diffractions at each scanning point and compute the amplitude and phase of the object. We demonstrate successful reconstructions using PtychoNet as well as recovering fine features in the case of extreme sparse scanning where conventional iterative methods fail to give recognizable features.

97 MATHEMATICS AND COMPUTING↗

Crystal structures of orthorhombic, hexagonal, and cubic compounds of the Sm{sub (x)}Yb{sub (2−x)}TiO{sub 5} series

A series of single phase compounds with nominal stoichiometry Sm{sub (x)}Yb{sub (2−x)}TiO{sub 5} (x=2, 1.4, 1, 0.6, and 0) have been successfully fabricated to generate a range of crystal structures covering the most common polymorphs previously discovered in the Ln{sub 2}TiO{sub 5} series (Ln=lanthanides and yttrium). Four of the five samples have not been previously fabricated in bulk, single phase form so their crystal structures are refined and detailed using powder synchrotron and single crystal x-ray diffraction, neutron diffraction and transmission electron microscopy. Based on the phase information from diffraction data, there are four crystal structure types in this series; orthorhombic Pnma, hexagonal P6{sub 3}/mmc, cubic (pyrochlore-like) Fd-3m and cubic (fluorite-like) Fm-3m. The cubic materials show modulated structures with variation between long and short range ordering and the variety of diffraction techniques were used to describe these complex crystal structure types. - Graphical abstract: A high resolution image of the compound Sm{sub 0.6}Yb{sub 1.4}TiO{sub 5} showing contrast from lattice fringes and the corresponding fast Fourier transform (FFT) of the HREM image with pyrochlore related diffraction spots marked “P” and fluorite marked “F”. The crystal is oriented down the [1 1 0] zone axis based on the Fd-3m structure. The ideal crystal structure (no vacancies) of the cubic, pyrochlore-like (Sm{sub 0.6}Yb{sub 1.4}TiO{sub 5}). - Highlights: • First fabrication of bulk single-phase material with stoichiometry Sm{sub 2}TiO{sub 5}. • Systematic study of crystal structure types within Ln{sub 2}TiO{sub 5} series (Ln=lanthanides). • A novel technique using IFFT of HREM images to study cubic structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Luminescence characteristics of Xe{sub 2}Cl excimer molecules under pumping the dense Xe-CCl{sub 4} gas mixtures with a pulsed electron beam

Temporal and spectral characteristics of the luminescence of dense Xe-CCl{sub 4} gas mixtures of different composition, excited by a 5-ns pulsed electron beam, were measured. The energy of the electrons amounted to 150 keV and the electron beam current pulse amplitude was 5 A. The gas mixtures were used containing Xe (38-700 Torr) and CCl{sub 4} (0.03-0.3 Torr). The studies were performed within the wavelength range 200-1200 nm using a MAYA-2000Pro diffraction grating spectrometer and a RIGOL DS 5022 ME fast digital oscilloscope. The luminescence lifetimes of the excimer molecules XeCl* (band with {lambda}{sub max} = 308 nm) and Xe{sub 2}Cl* (band with {lambda}{sub max} = 486 nm) were measured, as well as the constants of quenching by the components of the gas mixture for Xe{sub 2}Cl* molecules. A model of plasma-chemical processes for dense Xe-CCl{sub 4} gas mixtures with a very low content of the CCl{sub 4} donor is proposed. It is shown that in such 'poor' mixtures Xe{sub 2}Cl* molecules are mainly produced as a result of recombination of the Xe{sub 2}{sup +} and Cl{sup -} ions. (active media)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of pressure cycling and compression rate on the bcc-hcp transition in an FeNi alloy

Here, we investigate the body-centered cubic (bcc) to hexagonal close-packed (hcp) phase transition in Fe-10wt. %Ni alloy, combining pressure cycling and fast compression with time-resolved synchrotron x-ray diffraction in a dynamic diamond anvil cell. Three pressure cycles were conducted with compression rates ranging from 0.1 to nearly 10 3 GPa/s. During the first cycle with the slowest compression, the observed orientations in the bcc and hcp phases are consistent with the Burgers mechanism, followed by c-axis rotation of the hcp phase consistent with {$10$ $\bar{1}2$} twinning. During the following cycles with fast compression at 10 2 –10 3 GPa/s, the hcp phase exhibits negligible c-axis rotation with a nearly constant c/a ratio of ∼1.61 up to ∼30 GPa, indicating suppression of plastic deformation (especially, twinning) due to sample confinement from the gasket. Notably, the onset pressure of the transition decreases with additional pressure cycling and faster compression, which normally leads to over-pressurization. This suggests that defects or shear induced from the pressure cycling reduces the transition kinetics even during fast compression. These insights into the deformation and transition behavior in an FeNi alloy under multiple dynamic loading cycles can offer guidance for future design of advanced structural alloys and improve our understanding of planetary core processes.

FeNi alloy↗

In-line holography and coherent diffractive imaging with x-ray waveguides

A Fresnel coherent diffraction imaging experiment with hard x rays is here presented, using two planar crossed waveguides as optical elements, leading to a virtual pointlike source. The coherent wave field obtained with this setup is used to illuminate a micrometric single object having the shape of a butterfly. A digital two-dimensional in-line holographic reconstruction of the unknown object at low resolution (200 nm) has been obtained directly via fast Fourier transform (FFT) of the raw data. The object and its twin image are well separated because suitable geometrical conditions are satisfied. A good estimate of the incident wave field phase has been extracted directly from the FFT of the raw data. A partial object reconstruction with 50 nm spatial resolution was achieved by fast iterative phase retrieval, the major limitation for a full reconstruction being the nonideal structure of the guided beam. The method offers a route for fast and reliable phase retrieval in x-ray coherent diffraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fast two-stage algorithm for non-negative matrix factorization in smoothly varying data

This article reports the study of algorithms for non-negative matrix factorization (NMF) in various applications involving smoothly varying data such as time or temperature series diffraction data on a dense grid of points. Utilizing the continual nature of the data, a fast two-stage algorithm is developed for highly efficient and accurate NMF. In the first stage, an alternating non-negative least-squares framework is used in combination with the active set method with a warm-start strategy for the solution of subproblems. In the second stage, an interior point method is adopted to accelerate the local convergence. The convergence of the proposed algorithm is proved. The new algorithm is compared with some existing algorithms in benchmark tests using both real-world data and synthetic data. Furthermore, the results demonstrate the advantage of the algorithm in finding high-precision solutions.

interior point method↗

Fast helicity switching of x-ray circular polarization at beamline P09 at PETRA III

At the resonant scattering and diffraction beamline P09 at PETRA III/DESY, polarization manipulation in the X-ray energy range 3-13 keV is possible using wave-plates. Recently, fast flipping of circular polarization helicity using the Raspberry Pi controlled FPGA (PiLC) device developed at DESY and dedicated piezo-electric flippers has been commissioned. Functionality of the PiLC for XMCD and first XMCD measurements at the Fe K-and Dy-L{sub 3} absorption edges are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HYBRID simulations of diffraction-limited focusing with Kirkpatrick-Baez mirrors for a next-generation In Situ hard X-ray nanoprobe

Next-generation hard X-ray nanoprobe beamlines such as the In Situ Nanoprobe (ISN) beamline being planned at the Advanced Photon Source aim at providing very high spatial resolution while also enabling very high focused flux, to study complex materials and devices using fast, multidimensional imaging across many length scales. The ISN will use diffractive optics to focus X-rays with a bandpass of ΔE/E = 10 –4 into a focal spot of 20 nm or below. Reflective optics in Kirkpatrick-Baez geometry will be used to focus X-rays with a bandpass as large as ΔE/E = 10 –2 into a focal spot of 50 nm. Diffraction-limited focusing with reflective optics is achieved by spatial filtering and use of a very long, vertically focusing mirror. Furthermore, to quantify the performance of the ISN beamline, we have simulated the propagation of both partially and fully coherent wavefronts from the undulator source, through the ISN beamline and into the mirror-based focal spot. Simulations were carried out using the recently developed software “HYBRID.”

43 PARTICLE ACCELERATORS↗

Reaching the Diffraction Limit - Differential Speckle and Wide-Field Imaging for the WIYN Telescope

Speckle imaging allows telescopes to achieve diffraction limited imaging performance. The technique requires cameras capable of reading out frames at a very fast rate, effectively 'freezing out' atmospheric seeing. The resulting speckles can be correlated and images reconstructed that are at the diffraction limit of the telescope. These new instruments are based on the successful performance and design of the Differential Speckle Survey Instrument (DSSI).The instruments are being built for the Gemini-N and WIYN telescopes and will be made available to the community via the peer review proposal process. We envision their primary use to be validation and characterization of exoplanet targets from the NASA, K2 and TESS missions and RV discovered exoplanets. Such targets will provide excellent follow-up candidates for both the WIYN and Gemini telescopes. We expect similar data quality in speckle imaging mode with the new instruments. Additionally, both cameras will have a wide-field mode and standard SDSS filters. They will be highly versatile instruments and it is that likely many other science programs will request time on the cameras. The limiting magnitude for speckle observations will remain around 13-14th at WIYN and 16-17th at Gemini, while wide-field, normal CCD imaging operation should be able to go to much fainter, providing usual CCD imaging and photometric capabilities. The instruments will also have high utility as scoring cameras for telescope engineering purposes, or other applications where high time resolution is needed. Instrument support will be provided, including a software pipeline that takes raw speckle data to fully reconstructed images.

detector↗

Time-resolved x-ray diffraction techniques for bulk polycrystalline materials under dynamic loading

We have developed two techniques for time-resolved x-ray diffraction from bulk polycrystalline materials during dynamic loading. In the first technique, we synchronize a fast detector with loading of samples at strain rates of ∼10{sup 3}–10{sup 4} s{sup −1} in a compression Kolsky bar (split Hopkinson pressure bar) apparatus to obtain in situ diffraction patterns with exposures as short as 70 ns. This approach employs moderate x-ray energies (10–20 keV) and is well suited to weakly absorbing materials such as magnesium alloys. The second technique is useful for more strongly absorbing materials, and uses high-energy x-rays (86 keV) and a fast shutter synchronized with the Kolsky bar to produce short (∼40 μs) pulses timed with the arrival of the strain pulse at the specimen, recording the diffraction pattern on a large-format amorphous silicon detector. For both techniques we present sample data demonstrating the ability of these techniques to characterize elastic strains and polycrystalline texture as a function of time during high-rate deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silver chlorobromide nanocubes with significantly improved uniformity: synthesis and assembly into photonic crystals

Silver chlorobromide (AgClxBr1-x, 0 < x < 1) nanocubes with a highly uniform size, morphology, and crystallinity have been successfully synthesized through a co-precipitation of Ag+ ions with both Cl- and Br- ions in ethylene glycol containing polyvinyl pyrrolidone at mild temperatures. Compositions of the synthesized nanocubes can be easily tuned by controlling the molar ratio of Cl- to Br- ions in the reaction solutions. The size of the nanocubes is determined by varying a number of parameters including the molar ratio of Cl- to Br- ions, injection rate of Ag+ ions, and reaction temperature. The real-time formation of colloidal AgClxBr1-x nanocubes has been monitored, for the first time, by in situ highenergy synchrotron X-ray diffraction. The time-resolved results reveal that a fast injection rate of Ag+ ions is critical for the formation of AgClxBr1-x nanocubes with a highly pure face-centered cubic crystalline phase. The improved uniformity of the AgClxBr1-x nanocubes is beneficial for assembling them into order superlattices (e.g., photonic crystals) even by simply applying centrifugation forces. The stop band of the resulting photonic crystals can be easily tuned from the ultraviolet to the infrared region by using AgClxBr1-x nanocubes with different sizes. The variation of the dielectric constant of AgClxBr1-x associated with the change of the relative concentration of halide ions provides an additional knob to tune the optical properties of photonic crystals.

36 MATERIALS SCIENCE↗

Design and performance of a versatile curved-crystal spectrometer for high-resolution spectroscopy in the tender x-ray range

A complete in-vacuum curved-crystal x-ray emission spectrometer in Johansson geometry has been constructed for a 2-6 keV energy range with sub natural line-width energy resolution. The spectrometer is designed to measure x-ray emission induced by photon and charged particle impact on solid and gaseous targets. It works with a relatively large x-ray source placed inside the Rowland circle and employs position sensitive detection of diffracted x-rays. Its compact modular design enables fast and easy installation at a synchrotron or particle accelerator beamline. The paper presents main characteristics of the spectrometer and illustrates its capabilities by showing few selected experimental examples.

43 PARTICLE ACCELERATORS↗

The development of laser-plasma interaction program LAP3D on thousands of processors

Modeling laser-plasma interaction (LPI) processes in real-size experiments scale is recognized as a challenging task. For explorering the influence of various instabilities in LPI processes, a three-dimensional laser and plasma code (LAP3D) has been developed, which includes filamentation, stimulated Brillouin backscattering (SBS), stimulated Raman backscattering (SRS), non-local heat transport and plasmas flow computation modules. In this program, a second-order upwind scheme is applied to solve the plasma equations which are represented by an Euler fluid model. Operator splitting method is used for solving the equations of the light wave propagation, where the Fast Fourier translation (FFT) is applied to compute the diffraction operator and the coordinate translations is used to solve the acoustic wave equation. The coupled terms of the different physics processes are computed by the second-order interpolations algorithm. In order to simulate the LPI processes in massively parallel computers well, several parallel techniques are used, such as the coupled parallel algorithm of FFT and fluid numerical computation, the load balance algorithm, and the data transfer algorithm. Now the phenomena of filamentation, SBS and SRS have been studied in low-density plasma successfully with LAP3D. Scalability of the program is demonstrated with a parallel efficiency above 50% on about ten thousand of processors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time X-ray Diffraction: Applications to Materials Characterization

With the high speed growth of materials it becomes necessary to develop measuring systems which also have the capabilities of characterizing these materials at high speeds. One of the conventional techniques of characterizing materials was X-ray diffraction. Film, which is the oldest method of recording the X-ray diffraction phenomenon, is not quite adequate in most circumstances to record fast changing events. Even though conventional proportional counters and scintillation counters can provide the speed necessary to record these changing events, they lack the ability to provide image information which may be important in some types of experiment or production arrangements. A selected number of novel applications of using X-ray diffraction to characterize materials in real-time are discussed. Also, device characteristics of some X-ray intensifiers useful in instantaneous X-ray diffraction applications briefly presented. Real-time X-ray diffraction experiments with the incorporation of image X-ray intensification add a new dimension in the characterization of materials. The uses of real-time image intensification in laboratory and production arrangements are quite unlimited and their application depends more upon the ingenuity of the scientist or engineer.

Rosemeier, R. G.↗