Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Fast helicity switching of x-ray circular polarization at beamline P09 at PETRA III

At the resonant scattering and diffraction beamline P09 at PETRA III/DESY, polarization manipulation in the X-ray energy range 3-13 keV is possible using wave-plates. Recently, fast flipping of circular polarization helicity using the Raspberry Pi controlled FPGA (PiLC) device developed at DESY and dedicated piezo-electric flippers has been commissioned. Functionality of the PiLC for XMCD and first XMCD measurements at the Fe K-and Dy-L{sub 3} absorption edges are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HYBRID simulations of diffraction-limited focusing with Kirkpatrick-Baez mirrors for a next-generation In Situ hard X-ray nanoprobe

Next-generation hard X-ray nanoprobe beamlines such as the In Situ Nanoprobe (ISN) beamline being planned at the Advanced Photon Source aim at providing very high spatial resolution while also enabling very high focused flux, to study complex materials and devices using fast, multidimensional imaging across many length scales. The ISN will use diffractive optics to focus X-rays with a bandpass of ΔE/E = 10 –4 into a focal spot of 20 nm or below. Reflective optics in Kirkpatrick-Baez geometry will be used to focus X-rays with a bandpass as large as ΔE/E = 10 –2 into a focal spot of 50 nm. Diffraction-limited focusing with reflective optics is achieved by spatial filtering and use of a very long, vertically focusing mirror. Furthermore, to quantify the performance of the ISN beamline, we have simulated the propagation of both partially and fully coherent wavefronts from the undulator source, through the ISN beamline and into the mirror-based focal spot. Simulations were carried out using the recently developed software “HYBRID.”

43 PARTICLE ACCELERATORS↗

Time-resolved x-ray diffraction techniques for bulk polycrystalline materials under dynamic loading

We have developed two techniques for time-resolved x-ray diffraction from bulk polycrystalline materials during dynamic loading. In the first technique, we synchronize a fast detector with loading of samples at strain rates of ∼10{sup 3}–10{sup 4} s{sup −1} in a compression Kolsky bar (split Hopkinson pressure bar) apparatus to obtain in situ diffraction patterns with exposures as short as 70 ns. This approach employs moderate x-ray energies (10–20 keV) and is well suited to weakly absorbing materials such as magnesium alloys. The second technique is useful for more strongly absorbing materials, and uses high-energy x-rays (86 keV) and a fast shutter synchronized with the Kolsky bar to produce short (∼40 μs) pulses timed with the arrival of the strain pulse at the specimen, recording the diffraction pattern on a large-format amorphous silicon detector. For both techniques we present sample data demonstrating the ability of these techniques to characterize elastic strains and polycrystalline texture as a function of time during high-rate deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silver chlorobromide nanocubes with significantly improved uniformity: synthesis and assembly into photonic crystals

Silver chlorobromide (AgClxBr1-x, 0 < x < 1) nanocubes with a highly uniform size, morphology, and crystallinity have been successfully synthesized through a co-precipitation of Ag+ ions with both Cl- and Br- ions in ethylene glycol containing polyvinyl pyrrolidone at mild temperatures. Compositions of the synthesized nanocubes can be easily tuned by controlling the molar ratio of Cl- to Br- ions in the reaction solutions. The size of the nanocubes is determined by varying a number of parameters including the molar ratio of Cl- to Br- ions, injection rate of Ag+ ions, and reaction temperature. The real-time formation of colloidal AgClxBr1-x nanocubes has been monitored, for the first time, by in situ highenergy synchrotron X-ray diffraction. The time-resolved results reveal that a fast injection rate of Ag+ ions is critical for the formation of AgClxBr1-x nanocubes with a highly pure face-centered cubic crystalline phase. The improved uniformity of the AgClxBr1-x nanocubes is beneficial for assembling them into order superlattices (e.g., photonic crystals) even by simply applying centrifugation forces. The stop band of the resulting photonic crystals can be easily tuned from the ultraviolet to the infrared region by using AgClxBr1-x nanocubes with different sizes. The variation of the dielectric constant of AgClxBr1-x associated with the change of the relative concentration of halide ions provides an additional knob to tune the optical properties of photonic crystals.

36 MATERIALS SCIENCE↗

Design and performance of a versatile curved-crystal spectrometer for high-resolution spectroscopy in the tender x-ray range

A complete in-vacuum curved-crystal x-ray emission spectrometer in Johansson geometry has been constructed for a 2-6 keV energy range with sub natural line-width energy resolution. The spectrometer is designed to measure x-ray emission induced by photon and charged particle impact on solid and gaseous targets. It works with a relatively large x-ray source placed inside the Rowland circle and employs position sensitive detection of diffracted x-rays. Its compact modular design enables fast and easy installation at a synchrotron or particle accelerator beamline. The paper presents main characteristics of the spectrometer and illustrates its capabilities by showing few selected experimental examples.

43 PARTICLE ACCELERATORS↗

The development of laser-plasma interaction program LAP3D on thousands of processors

Modeling laser-plasma interaction (LPI) processes in real-size experiments scale is recognized as a challenging task. For explorering the influence of various instabilities in LPI processes, a three-dimensional laser and plasma code (LAP3D) has been developed, which includes filamentation, stimulated Brillouin backscattering (SBS), stimulated Raman backscattering (SRS), non-local heat transport and plasmas flow computation modules. In this program, a second-order upwind scheme is applied to solve the plasma equations which are represented by an Euler fluid model. Operator splitting method is used for solving the equations of the light wave propagation, where the Fast Fourier translation (FFT) is applied to compute the diffraction operator and the coordinate translations is used to solve the acoustic wave equation. The coupled terms of the different physics processes are computed by the second-order interpolations algorithm. In order to simulate the LPI processes in massively parallel computers well, several parallel techniques are used, such as the coupled parallel algorithm of FFT and fluid numerical computation, the load balance algorithm, and the data transfer algorithm. Now the phenomena of filamentation, SBS and SRS have been studied in low-density plasma successfully with LAP3D. Scalability of the program is demonstrated with a parallel efficiency above 50% on about ten thousand of processors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BraggNN : fast X-ray Bragg peak analysis using deep learning

X-ray diffraction based microscopy techniques such as high-energy diffraction microscopy (HEDM) rely on knowledge of the position of diffraction peaks with high precision. These positions are typically computed by fitting the observed intensities in detector data to a theoretical peak shape such as pseudo-Voigt. As experiments become more complex and detector technologies evolve, the computational cost of such peak-shape fitting becomes the biggest hurdle to the rapid analysis required for real-time feedback in experiments. To this end, we propose BraggNN, a deep-learning based method that can determine peak positions much more rapidly than conventional pseudo-Voigt peak fitting. When applied to a test dataset, peak center-of-mass positions obtained from BraggNN deviate less than 0.29 and 0.57 pixels for 75 and 95% of the peaks, respectively, from positions obtained using conventional pseudo-Voigt fitting (Euclidean distance). When applied to a real experimental dataset and using grain positions from near-field HEDM reconstruction as ground-truth, grain positions using BraggNN result in 15% smaller errors compared with those calculated using pseudo-Voigt. Recent advances in deep-learning method implementations and special-purpose model inference accelerators allow BraggNN to deliver enormous performance improvements relative to the conventional method, running, for example, more than 200 times faster on a consumer-class GPU card with out-of-the-box software.

36 MATERIALS SCIENCE↗

High-Precision Time Delay Control with Continuous Phase Shifter for Pump-Probe Experiments Using Synchrotron Radiation Pulses

Brilliant pulsed x-ray synchrotron radiation (SR) is useful for pump-probe experiment such as time-resolved x-ray diffraction, x-ray absorption fine structure, and x-ray spectroscopy. For laser pump-SR x-ray probe experiments, short pulsed lasers are generally synchronized to the SR master oscillator controlling the voltage for acceleration of electron bunches in an accelerator, and the interval between the laser and the SR pulses is changed around the time scale of target phenomenon. Ideal delay control produces any time delay as keeping the time-precision and pointing-stability of optical pulses at a sample position. We constructed the time delay control module using a continuous phase shifter of radio frequency signal and a frequency divider, which can produce the delayed trigger pulses to the laser without degradation of the time precision and the pointing stability. A picoseconds time-resolved x-ray diffraction experiment was demonstrated at SPring-8 storage ring for fast lattice response by femtosecond pulsed laser irradiation, and suggested the possibility of accurate sound velocity measurement. A delay control unit operating with subpicosecond precision has also been designed for femtosecond pump-probe experiments using a free electron laser at SPring-8 campus.

43 PARTICLE ACCELERATORS↗

Kinetic protein crystallography: a tool to watch proteins in action

Many proteins function in the crystalline state, making crystallography a tool that, beside structure, can address mechanism. By initiating biological turnover in the crystal, transient structural species form, which may be filmed 'on the fly' by Laue diffraction or captured by trapping methods. These strategies are jointly referred to as 'kinetic crystallography'. In this article, we review the general concepts of kinetic crystallography in the context of the conformational energy landscape of a protein. Whereas Laue diffraction is best suited to the investigation of cyclic, ultra-fast and light-triggered reactions, trapping approaches, on the other hand, are applicable to a wider range of biological systems but require care to avoid artefacts. Complementary methods - mainly UV/visible single-crystal spectroscopy - have proven essential to design, interpret and validate kinetic crystallography experiments. Achievements in the field as well as remaining puzzling questions are considered through the examination of recently published work: real-time-resolved crystallography of dimeric haemoglobin based on pump-probe Laue diffraction, temperature-trapping crystallography of acetylcholinesterase based on photo- and radio-induced ligand cleavage, and lattice-trapping crystallography of superoxide reductase based on product soaking and the combined use of X-ray diffraction and Raman spectroscopy.

59 BASIC BIOLOGICAL SCIENCES↗

The Synthesis, Characterization, and Structure Solution of SSZ-56: An Extreme Example of Isomer Specficity in the Structure Direction of Zeolites

The synthesis, structure solution, and characterization of the novel zeolite SSZ-56 (Si54.7B1.3O112) are described. SSZ-56 is synthesized under hydrothermal conditions using the trans-fused ring isomer of N,N-diethyl-2-methyldecahydroquinolinium as a structure directing agent. The synthesis of SSZ-56 is sensitive to the isomeric purity of the structure-directing agent. The structure of SSZ-56 was determined from powder diffraction data with the FOCUS Fourier recycling method using peak intensities extracted with the fast iterative Patterson squaring (FIPS) method. SSZ-56 possesses a relatively complex structure with 14 tetrahedral atoms in the asymmetric unit of its topological symmetry. Rietveld refinement of synchrotron X-ray powder diffraction data in space group P21/m (a = 13.9483 (2), b = 19.8958 (1), c = 12.3613 (1)A, ? = 106.68 degrees) confirms the proposed model. SSZ-56 possesses a 12-ring channel system that is intersected by a 10-ring channel system. The two-dimensional projection along the b-axis is similar to the projection along the pores of zeolite beta (polymorph B), and the two-dimensional projection along the c-axis is similar to the projections along the straight 10-ring channels of zeolite ZSM-5.

43 PARTICLE ACCELERATORS↗

Fully automatic characterization and data collection from crystals of biological macromolecules

A fully automatic system has been developed that performs X-ray centring and characterization of, and data collection from, large numbers of cryocooled crystals without human intervention. Considerable effort is dedicated to evaluating macromolecular crystals at synchrotron sources, even for well established and robust systems. Much of this work is repetitive, and the time spent could be better invested in the interpretation of the results. In order to decrease the need for manual intervention in the most repetitive steps of structural biology projects, initial screening and data collection, a fully automatic system has been developed to mount, locate, centre to the optimal diffraction volume, characterize and, if possible, collect data from multiple cryocooled crystals. Using the capabilities of pixel-array detectors, the system is as fast as a human operator, taking an average of 6 min per sample depending on the sample size and the level of characterization required. Using a fast X-ray-based routine, samples are located and centred systematically at the position of highest diffraction signal and important parameters for sample characterization, such as flux, beam size and crystal volume, are automatically taken into account, ensuring the calculation of optimal data-collection strategies. The system is now in operation at the new ESRF beamline MASSIF-1 and has been used by both industrial and academic users for many different sample types, including crystals of less than 20 µm in the smallest dimension. To date, over 8000 samples have been evaluated on MASSIF-1 without any human intervention.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photo-induced refractive index and topographical surface gratings in functionalized nanocarbon solid film

We demonstrate that a single-walled carbon nanotube network noncovalently coupled with a pyrene-modified azo-benzene chromophore functions as a host matrix for a broad range of photo-orientation and photomechanical effects. The chromophore could be efficiently reoriented through repeated trans-cis-trans isomerization under linearly polarized 480 nm light, with Δn of 0.012 at 650 nm and fast characteristic rise-times of 0.12 s. Erasable phase diffraction gratings could also be written, with permanent surface relief gratings forming at sufficiently long irradiation times. In addition to demonstrating a mechanism for photo-manipulation of single-walled carbon nanotubes, these results show photo-orientation of chromophores in azo-functionalized single-walled carbon nanotube networks as a path towards the photosensitive tuning of the electrostatic environment of the nanotube.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchrotron applications of an amorphous silicon flat-panel detector.

A GE Revolution 41RT flat-panel detector (GE 41RT) from GE Healthcare (GE) has been in operation at the Advanced Photon Source for over two years. The detector has an active area of 41 cm x 41 cm with 200 {micro}m x 200 {micro}m pixel size. The nominal working photon energy is around 80 keV. The physical set-up and utility software of the detector system are discussed in this article. The linearity of the detector response was measured at 80.7 keV. The memory effect of the detector element, called lag, was also measured at different exposure times and gain settings. The modulation transfer function was measured in terms of the line-spread function using a 25 {micro}m x 1 cm tungsten slit. The background (dark) signal, the signal that the detector will carry without exposure to X-rays, was measured at three different gain settings and with exposure times of 1 ms to 15 s. The radial geometric flatness of the sensor panel was measured using the diffraction pattern from a CeO{sub 2} powder standard. The large active area and fast data-capturing rate, i.e. 8 frames s{sup -1} in radiography mode, 30 frames s{sup -1} in fluoroscopy mode, make the GE 41RT one of a kind and very versatile in synchrotron diffraction. The loading behavior of a Cu/Nb multilayer material is used to demonstrate the use of the detector in a strain-stress experiment. Data from the measurement of various samples, amorphous SiO{sub 2} in particular, are presented to show the detector effectiveness in pair distribution function measurements.

43 PARTICLE ACCELERATORS↗

SISGR - In situ characterization and modeling of formation reactions under extreme heating rates in nanostructured multilayer foils

Materials subjected to extreme conditions, such as very rapid heating, behave differently than materials under more ordinary conditions. In this program we examined the effect of rapid heating on solid-state chemical reactions in metallic materials. One primary goal was to develop experimental techniques capable of observing these reactions, which can occur at heating rates in excess of one million degrees Celsius per second. One approach that we used is x-ray diffraction performed using microfocused x-ray beams and very fast x-ray detectors. A second approach is the use of a pulsed electron source for dynamic transmission electron microscopy. With these techniques we were able to observe how the heating rate affects the chemical reaction, from which we were able to discern general principles about how these reactions proceed. A second thrust of this program was to develop computational tools to help us understand and predict the reactions. From atomic-scale simulations were learned about the interdiffusion between different metals at high heating rates, and about how new crystalline phases form. A second class of computational models allow us to predict the shape of the reaction front that occurs in these materials, and to connect our understanding of interdiffusion from the atomistic simulations to measurements made in the laboratory. Both the experimental and computational techniques developed in this program are expected to be broadly applicable to a wider range of scientific problems than the intermetallic solid-state reactions studied here. For example, we have already begun using the x-ray techniques to study how materials respond to mechanical deformation at very high rates.

36 MATERIALS SCIENCE↗

Texture Evolution in U-10Mo Nuclear Fuel Foils during Plasma Spray Coating with Zr

A uranium-molybdenum alloy clad in 6061 aluminum has the potential to lead to a wide application of low-enriched uranium fuels, replacing highly enriched uranium for research reactors. A Zr coating acts as a diffusion barrier between the fuel and the aluminum cladding. In this study, U-10Mo (mass %) was coated with Zr using a plasma spray technique recognized as a fast and economical coating method. Neutron time-of-flight diffraction was used to study the microstructure evolution by quantifying the phase fractions of involved phases as well as the texture evolution of U-10Mo and Zr during plasma spray coating with Zr. Quantitative texture analysis revealed that the texture was drastically changed for high coating temperatures, likely due to selective grain growth. Furthermore, the Zr coating showed a preferential orientation, which could be correlated with the initial texture of the uncoated U-10Mo. This could be explained by the epitaxial growth of the Zr on the U-10Mo substrate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗