Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast reactors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Feasibility of Lead Fast Reactor Heat Exchanger Tube Online Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, wedges vs. direct application of piezoelectric sensors, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Impact of nuclear data covariance libraries on uncertainty quantification of sodium cooled fast reactor simulation

Uncertainty quantification in core modelling to assess reactor performance is a regular practice to identify design safety limits. Best-estimate plus uncertainty (BEPU) methods are commonly used to propagate uncertainties to core responses from input parameters, characterized by variance-covariance libraries. This study evaluates the impact of different covariance libraries on the uncertainty associated with core safety parameters and their propagation through reactor transient modelling for a metallic core (ABR-1000). The COMAC-1.0, COMMARA-2.0, and COMMARA-2.1 covariance libraries are used to propagate nuclear data uncertainties to neutron feedback coefficients using the Generalized Perturbation Theory, then through transient safety analyses to establish the confidence interval for safety performance of the reactor using stochastic sampling. The considered transients include Unprotected Transient Over Power and Unprotected Loss Of Flow. Most influential nuclide and reaction pairs in different variance-covariance libraries are identified and their impact on the uncertainty of safety parameters are evaluated. Significant differences were observed between uncertainties from COMAC compared to COMMARA libraries. Uncertainties from COMMARA libraries were consistently larger than COMAC for all cases. For structure, coolant density feedback coefficients and control rod worth, total nuclear data uncertainties were approximately 50% larger for COMMARA than COMAC. Differences were also observed in identification of top contributors of uncertainty in terms of reaction-cross sections. For instance, largest contribution to total uncertainty of radial expansion coefficient from COMMARA-2.0 and 2.1 originates from Na{sup 23} P1 Elastic cross section (0.81%) but from Pu{sup 239} Fission (0.53%) with COM C-1.0. Such differences are evaluated in this research for all quantities of interest. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status of the NEAMS and ARC neutronic fast reactor tools integration to the NEAMS Workbench

The Workbench initiative was launched in FY-2017 within the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program to facilitate the transition from conventional tools to high-fidelity tools. The Workbench provides a common user interface for model creation, real-time validation, execution, output processing, and visualization for integrated codes. The integration of the Argonne Reactor Computation (ARC) suite of codes into the NEAMS Workbench was initiated in FY-2017.

97 MATHEMATICS AND COMPUTING↗