Search NASA⌕ Search

SEARCH · Search NASA

Results for “fire test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Identifying Characteristics of Wildfire Towers and Troughs

Wildfire behavior is dictated by the complex interaction of numerous physical phenomena including dynamic ambient and fire-induced winds, heat transfer, aerodynamic drag on the wind by the fuel and combustion. These phenomena create complex feedback effects between the fire and its surroundings. In this study, we aim to study the mechanisms by which buoyant flame dynamics along with vortical motions and instabilities control wildfire propagation. Specifically, this study employs a suite of simulations conducted with the physics-based coupled fire-atmosphere behavior model (FIRETEC). The simulations are initialized with a fire line and the fires are allowed to propagate on a grass bed, where the fuel heights and wind conditions are varied systematically. Flow variables are extracted to identify the characteristics of the alternating counter-rotational vortices, called towers and troughs, that drive convective heat transfer and fire spread. These vortices have previously been observed in wildfires and laboratory fires, and have also been observed to arise spontaneously in FIRETEC due to the fundamental physics incorporated in the model. However, these past observations have been qualitative in nature and no quantitative studies can be found in the literature which connected these coherent structures fundamental to fire behavior with the constitutive flow variables. To that end, a variety of state variables are examined in the context of these coherent structures under various wind profile and grass height conditions. Identification of various correlated signatures and fire-atmosphere feedbacks in simulations provides a hypothesis that can be tested in future observational or experimental efforts, potentially assisting experimental design, and can aid in the interpretation of data from in situ detectors.

54 ENVIRONMENTAL SCIENCES↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Benchmarking MELCOR's NAC Package to ABCOVE Tests AB5 and AB6

This report presents analyses of the AB5 and AB6 ABCOVE sodium spray fire experiments with the MELCOR code. This code simulates the progression of accident events for analysis and auditing purposes of nuclear facilities during accident conditions. Historically, the ABCOVE experiments have contributed to the validation of aerosol physics and related phenomena. Given advancements in sodium-cooled reactor designs, characterization of the sodium spray combustion may further the review and validation of newly incorporated sodium properties and physics packages, namely, the sodium equations of state (EOS) and the sodium combustion (NAC) package within MELCOR. By analyzing the AB5 and AB6 experiments with and without the NAC package, sodium specificity for spray combustion and aerosol formation as well as speciation of the combustion products are reviewed with the new packages. This effort provides code users with a demonstration of the current code capabilities. This report provides the current best practices for the NAC package as well as a discussion of any issues observed while performing the presented analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Degradation and Accelerated Recovery of Surface Passivation in n+, p+, and Intrinsic Poly-Si/SiOx Passivating Contacts for Silicon Solar Cells

We report on the degradation and recovery of surface passivation of fired poly-Si/SiOx passivating contacts with hydrogen containing Al2O3 during annealing in the dark and under illumination. Upon firing to a peak temperature of 670 degrees C, the iVoc for symmetric test structures with n+, p+, and intrinsic poly-Si/SiOx contacts decreases due to a loss of surface passivation. Upon further annealing over the temperature range of 200-350 degrees C in the dark, depending on the type of doping, the surface passivation either shows further degradation followed by recovery, or direct recovery to the initial iVoc. Annealing at higher temperatures and/or higher illumination intensities accelerates the kinetics for both degradation and recovery processes. We show that the degradation and recovery processes are thermally activated and proceed identically in subsequent firing and annealing steps showing their cyclic nature. We present a series reaction model to explain the kinetics of degradation and recovery processes for n+ and intrinsic poly-Si/SiOx contacts. By fitting the model's rate expressions to the data, the determined effective activation energy barriers for degradation and recovery for n+ poly-Si/SiOx contacts in the dark are 1.24 and 1.51 eV, which are lowered under 7.5 Suns illumination to 0.76 and 1.15 eV, respectively.

14 SOLAR ENERGY↗

MARVEL 90% Final Design Report

This document provides documentation of the Microreactor Applications Research Validation and Evaluation Project’s (MARVEL) 90% Final Design, as required by U.S. Department of Energy (DOE) Standard-1189, “Integration of Safety into the Design Process." Per DOE-STD-1189-2016, the 90% Final Design documentation focuses on design completion, at a level capable of supporting procurement, construction, testing, and operation. At this phase, the design organization finalizes the hazards and accident analyses, Fire Hazard Analysis (FHA), security vulnerability assessments, and other supporting analyses for design completion. The objective of this report is to provide a high-level summary of the design thus far and provide references including, but not limited to, the following design deliverables: • Complete final drawings, specifications and commercial grade dedications that may be released for bid and/or construction. • Clearly defined testing plans for the safety and functionality of all subsystems. • Quality Assurance Program for Design, Testing and Procurement. • Software Quality Assurance Plan. • Code of Record (COR), applicable design requirements including codes and standards. • Final design that meets all the requirements stipulated in the COR. • Final design review, consisting of final validation of comment resolution from previous reviews, and a review of any additional developments since the last review. • Updated Safety Design Strategy. • Hazard Analysis. • Fire Hazard Analysis. • Accident analysis. • Security vulnerability assessment. • Current and detailed cost estimate. • Current construction schedule, and • Risk & Opportunities Assessment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A High-Voltage High-Current Benchtop Test Stand for Solid-State Switch Testing at the SNS

Solid-state switches already replaced thyratrons in the SNS extraction kicker power supplies, offering improved efficiency and reliability. However, recent supply chain disruptions, combined with a self-firing issue, led us to explore alternative solutions. A vendor-developed MOS-Gated Thyristor switch was introduced but ultimately failed during testing. To investigate the failure and assess possible improvements, a benchtop test stand was constructed to evaluate the performance of a single stage board. This test stand features a Pulse Forming Network (PFN) that operates at 6 kV and 6 kA, with a repetition rate exceeding 60 Hz, simulating real operational conditions. By utilizing this setup, we seek to gain a better understanding of the failure mechanisms, refine the switch designs, and ultimately develop a more reliable alternative for the extraction kicker power supplies.

Bullman, Austin [ORNL]↗

Cooperative Education

M-3 Focused Experiments is a group at Los Alamos National Lab (LANL) and is under the Dynamic Experiments Division. Their work surrounds the diagnostics and study of explosives and their interaction with materials. The data collected is used to better understand the erratic nature of explosions and high velocity projectiles. Through better comprehension of this science, the overall national security will be improved while innovations are made along the way. Despite the strong drive for research and development, the lab holds safety above all else and constantly updates procedures to protect LANL employees and their environment. At any time, there are multiple projects going on at once within the team and I am tasked with assisting the Firing Site Leaders and various research diagnosticians in any way possible with the setup, testing, and execution of data collection for each experiment. Such data includes velocity, fragmentation characteristics, and the spread of energy across the material to name a few. During my summer employment with the lab, my main goal is to maintain a questioning attitude and learn as much possible about the research and development side of science and engineering. Throughout the duration of the Co-op, many experiments will take place at specially designed firing sites which is where I will be spending most of my time.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Release of Contaminants from Burning Liquids and Solids

This report details model development, theory, and a literature review focusing on the emission of contaminants on solid substrates in fires. This is the final report from a 2-year Nuclear Safety Research and Development (NSRD) project. The work represents progress towards a goal of having modeling and simulation capabilities that are sufficiently mature and accurate that they can be utilized in place of physical tests for determining safe handling practices. At present, the guidelines for safety are largely empirically based, derived from a survey of existing datasets. This particular report details the development, verification and calibration of a number of code improvements that have been implemented in the SIERRA suite of codes, and the application of those codes to three different experimental scenarios that have been subject of prior tests. The first scenario involves a contaminated PMMA slab, which is exposed to heat. The modeling involved a novel method for simulating the viscous diffusion of the particles in the slab. The second scenario involved a small pool fire of contaminated combustible liquid mimicking historical tests and finds that the release of contaminants has a high functionality with the height of the liquid in the container. The third scenario involves the burning of a contaminated tray of shredded cellulose. A novel release mechanism was formulated based on predicted progress of the decomposition of the cellulose, and while the model was found to result in release that can be tuned to match the experiments, some modifications to the model are desirable to achieve quantitative accuracy.

54 ENVIRONMENTAL SCIENCES↗

Recovery of DNA from fired and unfired cartridge casings: comparison of two DNA collection methods

For over 10 years, various studies have attempted to increase the recovery of DNA from ammunition by modifying the DNA collection, extraction, purification, and amplification procedures, with varying levels of success. This study focused on the “soaking” method of Montpetit & O’Donnell [1] and the “rinse-and-swab" method of Bille et al. [2]. First, testing for the presence of exogenous DNA, 210 boxed cartridges (brass, steel, and nickel-plated) from nine manufacturers were swabbed and DNA was extracted, concentrated, and quantified. Extracts that quantified > 0 ng/µL (44 of 210) were amplified and genotyped with GlobalFiler™. Of those, only one extract yielded two alleles indicating that the manufacturing and packaging of ammunition was virtually DNA free. Next, to obtain a baseline comparison of two DNA collection methods on a non-metallic substrate and identify a suitable number of cells to spot on cartridges, different DNA input amounts of primary human adult epidermal keratinocytes (HEKa) were tested. Thereafter, 300 brass and 300 nickel-plated, cartridges were spotted with HEKa cells containing ~5 ng of DNA, fired or unfired, and processed with either method. Finally, five methods representing hybrids of the soaking and rinse-and-swab methods were tested to determine if variations of those methods could be used to increase DNA yield and recovery. The results show that the soaking method consistently yielded more DNA than the rinse-and-swab method from a non-metallic substrate. However, the comparison study demonstrated that both methods performed comparably for cartridges. On average, the soaking method recovered 0.25 ng of DNA (5.1% recovery) and the rinse-and-swab method recovered 0.28 ng (5.8% recovery). However, average recoveries were significantly different among three analysts and considerable variation in yields were observed, possibly due to storage time. Furthermore, consistent with prior reports, the DNA recovered from brass casings was only 16% of that recovered from nickel-plated casings and the average yield of DNA from fired casings was reduced to 67% of unfired casings. Moreover, DNA extracts from brass or nickel-plated casings did not appear to contain amplification inhibitors and only 30/596 appeared severely degraded. Finally, both the published rinse-and-swab and soaking methods yielded more DNA than all modifications of the two methods. Overall, both methods yielded equivalent DNA quantities. Additionally, recovery of DNA from any given cartridge casing may be dependent on storage time as well as the skill, proficiency, and experience of the analyst and may reflect stochastic effects, particularly for casings containing low copy and/or degraded DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Foam Degradation Model during Thermal Hypothetical Accident Conditions

Current practice in Safety Analysis Report for Packaging (SARP) thermal analysis for hypothetical accident conditions (HAC) of packages is to not explicitly model the consequence to the foam impact limiting material, but instead to make conservative estimates of those consequences and begin calculations from that point. This approach is typically used for the foam regression distance, which is the thickness of the degraded foam layer after the 30-minute fire event. Estimates for regression distance can come directly from package burn test results or from correlations based on one-dimensional testing by the foam manufacturer. In either case, this is a subjective process, and although it can be used to produce a conservative result, it is a significant approximation in the analysis. This paper describes testing and refinement of a simplified foam regression model. Comparisons are made against available data from laboratory experiments. Model refinements were tested until satisfactory agreement was achieved. The final modeling approach was then compared with post-test inspection results from HAC burn test data. A new model with an effective thermal conductivity based on foam to char density variation was shown successful in representing laboratory-scale foam thermal degradation experiments and full-scale burn tests of a current package. This model offers a technically defensible and predictive approach for modeling thermal degradation of rigid polyurethane insulation in transport packages.

36 MATERIALS SCIENCE↗

Development and Reliability of Screen-Printable Fire-Through Cu Paste for Passivated Contact Solar Cells

We present the development of copper (Cu) paste which has been screen printed on Selective Emitter-Passivated Emitter Rear Contact (SE-PERC) solar cells. This paste can also be applied to Tunnel Oxide Passivated Contact (TOPCON) solar cells due to its fire-through nature. Champion PERC cells have achieved ....efficiency with ...parameters . Accelerated testing to investigate reliability performance of the SE- PERC mini-modules were carried out in damp heat chamber with 85oC and 85% humidity. The devices were found to be operational even after 1,500 hours. Devices with screen printed Ag contacts on the front side have been studied in parallel to the Cu contacts for comparison.

copper paste↗

Final Report on Aerosol Pretreatment Technology Performance and Benchmarking

Solvent-based post-combustion CO 2 capture (PCC) technology remains one of the leading methods to combat global CO 2 emissions produced from large-scale coal-fired power production. Advanced solventbased PCC technology has made significant improvements in design and performance that reduce capital and operating costs to enable its commercial use. Key to low cost, manageable logistics, and environmentally safe operation of solvent-based PCC technology are minimal solvent losses from the process through the treated gas stream exiting PCC plant absorbers. High flue gas aerosol particle concentrations (>10 5 particles/cm 3 ) for particles in the range of 70-200 nm have been shown to cause significant amine solvent losses for solvent-based PCC processes through several mechanisms including absorption of solvent and water into growing aerosol particles. Flue gas aerosol pretreatment technology is the only realistic and economically attractive method to reduce very high aerosol particle concentrations (>10 7 particles/cm 3 ) to enable solvent-based PCC for existing power plants lacking sufficient particle removal systems, such as baghouses. The overall goal of this project was to design, construct, independently test, and evaluate three flue gas aerosol pretreatment technologies identified to significantly reduce high aerosol particle concentrations (>10 7 particles/cm 3 ) in the 70-200 nm particle size range: (1) a novel, high-velocity water injection spray concept developed by RWE and tested by Linde, (2) an innovative electrostatic precipitator (ESP) device with optimized operating conditions developed by Washington University in St. Louis (WUSTL), and (3) a non-regenerative sorbent-based filter technology developed by InnoSepra for SO x and NO x removal from coal-fired power plant flue gas. Each technology has been validated with tests on 500-1000 scfm of actual coal-fired flue gas and evaluated in terms of particle removal efficiency (%), cost competitiveness, and environmental impact. Aerosol measurements were performed upstream and downstream of each aerosol reduction unit during independent testing of each technology using advanced instrumentation and analytical methods provided by WUSTL. To perform aerosol measurements, isokinetic probes were inserted into flanged pipes attached to the flue gas piping, and a small suction pump was used to sample gas containing aerosol particles. Aerosol particle number concentrations (# particles/cm 3 ) and size distributions were then measured using a scanning mobility particle sizer (SMPS, TSI Inc.) for very fine particles (<1,000 nm) and a particle counter manufactured by GRIMM for particles larger than 1,000 nm. This report summarizes the aerosol removal performance results from pilot scale testing of each technology. Performance results have been benchmarked against pre-defined targets and other flue gas aerosol pretreatment technologies with documented performance. Linde Gas North America LLC has been the prime contractor to DOE responsible for overall project management and provided the design for the high-velocity water spray-based aerosol removal technology based on a design concept developed by the German utility company RWE.

20 FOSSIL-FUELED POWER PLANTS↗

Grid Resilient, Self-Powered, Fuel Flexible, High Efficiency Heating System (Final Report)

The Grid Independent High Efficiency System (GIHES) delivers a heating system that operates free from the power grid and provides ultra-low emissions and high efficiency heating for residential and commercial buildings. The project demonstrated two weeks of continuous grid independent operation of a storage water heater equipped with a powered damper. The Thermoelectric Generator (TEG) integrated GIHES technology revolutionizes heating systems to provide grid resilient hot water production, while delivering significant value to the end user by eliminating impacts of power interruption and enhancing comfort, convenience and productivity. The system maximizes the thermal-to-electric conversion efficiency by optimizing location and orientation of the TEGs and durability while lowering system costs. The TEGs generate enough power to charge a battery and run the storage water heater unit with a powered damper uninterrupted by providing the required parasitic electrical power for start-up, shutdown and during idling. Several TEGs were analytically and experimentally evaluated based on the size, surface area and the power being generated before designing and fabricating a complete multi-TEG assembly for integration with the water heater. The GIHES technology can be extended to boilers, furnaces and tankless water heaters and integrated with heat pump to further increase the overall equipment efficiency. The technology has the potential to reduce the amount of dispatch power and peak power plant operation. An advanced burner was designed, developed and 3D printed for fuel flexible operation. The burner was designed to enable tighter integration with TEGs for potentially higher TEG output, should this be necessary. A bench-scale test rig to perform testing of a 200,000 Btu/h burner and capable of handling up to 10% H2 (by volume) was setup at GTI’s laboratory with appropriate safety and controls to ensure smooth and safe operation. Testing of the 3D burner showed < 5 ppm NOx emissions can be achieved for the entire firing range and with different levels of hydrogen blends with natural gas. The burner will enable a more integrated TEG-burner module design for improved system performance, should this be required in the future. Techno-economic analysis (TEA) of the TEG integrated with the water heaters was performed. The testing data and the power output were used to develop the TEA. The analysis for the storage unit with damper showed that the TEG integrated system costs $95. This is much lower than a one-time charge needed to wire and install dedicated power. Discussions with TEG manufacturers and OEM’s will provide more detailed information and methods to further lower these costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bench scale development of a hybrid membrane-absorption CO 2 capture process (Final Report)

This final technical report describes work conducted for the Department of Energy (DOE) on the development of a bench-scale hybrid membrane-absorption carbon dioxide (CO 2 ) capture system for coal-fired power plant applications (Cooperative Agreement number DE-FE0013118). The work was conducted by Membrane Technology and Research, Inc. (MTR) with major support from the University of Texas at Austin (UT Austin) from April 1, 2013 through September 30, 2018. The overall goal of this project was to evaluate two variations of a hybrid membrane-absorption capture system combining the MTR air-swept PolarisTM membrane technology, which enriches flue gas to ~20% CO 2 , with UT Austin’s absorption-based advanced flash stripper (AFS) using piperazine (PZ), to determine the superior hybrid variant and to assess the potential of hybrid capture systems to achieve a lower cost-of-capture, compared to NETL’s reference amine-based capture plant. This project included the evaluation, development and testing of a hybrid membrane-absorption CO 2 capture system for coal-fired power plant applications using the MTR high-gas-flow, low-pressure-drop membrane contactor. The ability of the membrane contactor to enrich coal-fired flue gas from its normal content of ~13% CO 2 into a smaller volume of gas containing 20-25% CO 2 – with minimal energy input – could reduce the cost of the final concentration process, regardless of whether it is absorption, adsorption, cryogenic, or membrane-based. In this project, we are evaluating the feasibility of a hybrid system combining the MTR sweep membrane technology with the UT Austin piperazine-based advanced flash stripper (PZAS) capture system.

20 FOSSIL-FUELED POWER PLANTS↗

Bench-Scale Development of a Hybrid Membrane-Absorption CO 2 Capture Process

This final technical report describes work conducted for the Department of Energy (DOE) on the development of a bench-scale hybrid membrane-absorption carbon dioxide (CO 2 ) capture system for coal-fired power plant applications (Cooperative Agreement number DE-FE0013118). The work was conducted by Membrane Technology and Research, Inc. (MTR) with major support from the University of Texas at Austin (UT Austin) from April 1, 2013 through September 30, 2018. The overall goal of this project was to evaluate two variations of a hybrid membrane-absorption capture system combining the MTR air-swept Polaris TM membrane technology, which enriches flue gas to ~20% CO 2 , with UT Austin’s absorption-based advanced flash stripper (AFS) using piperazine (PZ), to determine the superior hybrid variant and to assess the potential of hybrid capture systems to achieve a lower cost-of-capture, compared to NETL’s reference amine-based capture plant. This project included the evaluation, development and testing of a hybrid membrane-absorption CO 2 capture system for coal-fired power plant applications using the MTR high-gas-flow, lowpressure- drop membrane contactor. The ability of the membrane contactor to enrich coal-fired flue gas from its normal content of ~13% CO 2 into a smaller volume of gas containing 20-25% CO 2 – with minimal energy input – could reduce the cost of the final concentration process, regardless of whether it is absorption, adsorption, cryogenic, or membrane-based. In this project, we are evaluating the feasibility of a hybrid system combining the MTR sweep membrane technology with the UT Austin piperazine-based advanced flash stripper (PZAS) capture system.

99 GENERAL AND MISCELLANEOUS↗

NSRC makes vital vintage films accessible to today's weapons researchers

A few years ago, archivists at the Lab’s National Security Research Center (NSRC) rediscovered 65 special reels of nitrate motion picture film among the 20,000 film reels in the NSRC’s collections. Because nitrate film stock was discontinued in 1951, they realized that the films contained footage from the Lab’s earliest days of nuclear testing. However, nitrate film is highly toxic and flammable. Confirming this hunch would have to wait until the NSRC team devised a strategy for safely preserving and digitizing the reels. Now, after many months of planning and collaboration with LANL fire safety and industrial hygiene teams, the reels – which include footage from Operation Sandstone, Operation Ivy, and the Trinity test – have been digitized by the NSRC archivist team and are accessible to today’s researchers.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Measurement of Convective Heat Transfer Coefficients With Supercritical CO 2 Using the Wilson-Plot Technique

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in a smooth tube and compares the results with published correlations for validation. The paper also describes the Heat Exchange and Experimental Testing (HEET) rig recently designed and built at the U.S. Department of Energy’s (DoE’s) National Energy Technology Laboratory (NETL) in Morgantown, WV. Here, the Wilson-plot technique used for measuring the heat transfer coefficients is described along with the data reduction process. The Wilson-plot technique was chosen as the basis for the design of NETL’s HEET rig. Advantages of the Wilson-plot technique include the (1) ability to measure high convective heat transfer coefficients accurately, (2) ability to measure average heat transfer coefficient for complicated heat exchange geometries like those produced using additive manufacturing, (3) ability to measure heat transfer coefficients on both sides of a heat exchanger independently, and (4) simplicity of experimental setup. Capabilities of the HEET rig include pressure to 24 MPa (3500 psig), temperature to 538 °C (1000 °F), mass flow rate to 1.5 kg/s (3 lb/s), and Re to 500,000. The rig is designed to operate with pure CO 2 or a mixture of CO 2 and up to 10% N2 by volume to study the impact of gas mixtures typical of direct-fired sCO 2 power cycles on the convective heat transfer and pressure drop. Preliminary tests in the HEET rig were performed with smooth stainless-steel tube and pure CO 2 , and the results were compared with published correlations for Nusselt number (Nu) and friction factor. Over a Reynolds number (Re) range from 58,000 to 228,000, measured Nu was compared to predictions using the Dittus and Boelter equation (Kreith and Bohn, 1993, “Principles of Heat Transfer, West Publishing Company”) within 5% and measured friction factors were compared to predictions using the McAdams correlation (“McAdams, 1954, “Heat Transmission,” 3rd ed., McGraw Hill, New York)” for smooth tube to be within 5%.

42 ENGINEERING↗