Search NASASearch

SEARCH · Search NASA

Results for “flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium

Techno-Economic Viability of Flexible Dispatch of Unconventional Geothermal Systems

Flexible geothermal operations could boost project returns through the allocation of improved power purchase agreements and/or exploitation of power price arbitrage opportunities. In this study, we investigated the techno-economic feasibility of variable flow rate control and time-of-day pricing in closed-loop geothermal systems. We considered U-shaped multilateral system configurations and modeled a variety of technical system parameters. These designs were simulated using a slender-body theory (SBT) model for transient heat transfer and fluid flow. This subsurface model was integrated into the flexible geothermal economic model (FGEM) tool to evaluate the overall flexible geothermal system techno-economics. Future hourly ambient temperature conditions were based on the Sup3rCC dataset. Published datasets were used for future hourly wholesale electricity prices. We analyzed four operating strategies: 1) baseload operation, 2) seasonal dispatch (high flow rate during summer and nominal flow rate during the rest of the year), 3) net generation maximization by varying flow rate to maximize net power output, and 4) revenue maximization by varying flow rate to maximize revenue. We ran all four scenarios for a multiloop configuration with 12 lateral passes, 7-km vertical depth and 87-km total drilling length. Furthermore, we assumed a 60 degrees C/km geothermal gradient and ambient temperature and wholesale electricity prices for New Mexico as a typical state location. The nominal flow rate was set to 80 kg/s. When considering drilling costs of $1,000/m and a discount rate of 7%, the generation maximization scenario resulted in the lowest levelized cost of electricity (LCOE) of ~$150/MWh. When considering project return on investment (ROI), defined as lifetime net income divided by upfront capital costs, all flexible operation scenarios performed better than the base case scenario. The highest ROI of 80% was obtained with the revenue maximization scenario. With drilling costs of $200/m and a discount rate of 5%, the generation maximization scenario resulted in LCOE of $49/MWh.

flexible geothermal

Bilayer Electron Transport Layers for High–Performance Rigid and Flexible Perovskite Solar Cells

While great progress is being made in achieving high power conversion efficiency (PCE), durability, and reliability in rigid and flexible n–i–p perovskite solar cells (PSCs), there is still room for improvement. Among myriad ways this can be achieved, one way is to improve the processing and quality of electron transport layers (ETLs) used in PSCs. To that end, here we explore the use of SnO 2 /TiO 2 bilayer ETLs in both rigid and flexible PSCs. In the case of rigid PSCs, chemical bath deposition (CBD) is used where the bilayer architecture affords the CBD of high-quality ETL, which results in PSCs with up to 25.13% PCE and operational stability T 80 (80% of initial PCE retained) of 2220 h under 1-sun continuous illumination with maximum power-point tracking. In the case of flexible PSCs, once again, the bilayer architecture allows us to fabricate high-quality ETL using spin coating, which results in PSCs with up to 22.54% PCE and excellent mechanical durability, withstanding 20 000 bending cycles with ≈92% of the initial PCE retained. Mechanisms underlying the enhanced performance and stability/durability of rigid and flexible PSCs that use SnO 2 /TiO 2 bilayer ETLs are elucidated. Furthermore, this approach could be extended to other ETL systems for PSCs for further improvements in PCE, durability, and reliability.

14 SOLAR ENERGY

Machine Learning Interatomic Potentials for Modeling Framework Flexibility and Water Uptake in NbOFFIVE-1-Ni Metal–Organic Framework

Metal–organic frameworks (MOFs), with their distinctive porous structures and tunable chemical properties, have shown immense promise in the separation and storage of gases. Currently, the accurate simulation of their adsorptive properties remains challenging, especially for systems where the molecules fit very tightly into the pores. Traditional simulation methods often approximate the frameworks as rigid and do not account for the framework flexibility seen in materials such as NbOFFIVE-1-Ni. First-principles molecular dynamics (FPMD) simulations offer the desired accuracy in modeling this flexibility but are limited by their extensive computational demands, rendering them impractical for long simulations. Conversely, classical force field-based simulations offer computational efficiency but lack the necessary accuracy. Here, to break this accuracy-efficiency trade-off, we have developed machine learning interatomic potentials trained on energies and forces from FPMD to model the framework flexibility of NbOFFIVE-1-Ni in the presence of water over nanosecond time scales. Furthermore, by integrating MLIP-driven molecular dynamics (MLIP-MD) with grand canonical Monte Carlo (GCMC) simulations, we further incorporated framework flexibility into adsorption predictions, yielding water adsorption isotherms that better align with experimental data compared to those of conventional GCMC simulations. These advances offer new opportunities for the design and optimization of MOFs in gas storage and separation applications.

adsorption

Torsional Flexibility Tuning of Hexa-Carboxylate Ligands to Unlock Distinct Topological Access to Zirconium Metal–Organic Frameworks

Zirconium-based metal–organic frameworks (Zr-MOFs) exhibit remarkable structural diversity and functionality. However, uncovering new topological types within this family remains a considerable challenge today. Herein, we report two new hexa-topic ligands designed through the introduction of torsional flexibility, which enable the construction of two Zr-MOFs featuring rare network topologies. The (4,4′,4″,4‴,4‴′,4‴′′-((2-carboxybenzene-1,3,5-triyl)tris(9H-carbazole-9,3,6-triyl))hexabenzoic acid ligand (BTCH)) was obtained by replacing the rigid triptycene core in the H6PET-1 ligand (4,4′,4″,4‴,4‴′,4‴′′-(9,10-dihydro-9,10-[1,2]benzenoanthracene-2,3,6,7,14,15-hexayl)hexabenzoic acid) with a benzene-tricarbazole unit. Owing to its torsionally flexible core that allows rotational freedom to the arms, this ligand directs the construction of NU-2620 (NU represents Northwestern University), a Zr-MOF with 8-connected Zr6 clusters and the rare nuh topology. Further flexibilization of the carbazole units to benzene rings yielded the even more torsionally flexible 5′,5‴-bis(4-carboxyphenyl)-5″-(4,4″-dicarboxy-[1,1′:3′,1″-terphenyl]-5′-yl)-[1,1′:3′,1″:3″,1‴:3‴,1‴′-quinquephenyl]-4,4‴′-dicarboxylic acid ligand (CCTT), which forms NU-2630 featuring 6-connected clusters and the pcu topology. Both frameworks exhibit good chemical stability, prompting evaluation of their performance in CO2 photoreduction catalysis. Under low-concentration CO2 conditions, NU-2620 displays markedly higher catalytic activity than its benzene-based analogue, NU-2630, thanks to the abundance of photoactive carbazole units within its structure. These results demonstrate that introducing torsional flexibility in high-connected linkers can unlock access to new topologies and accelerates the reticular expansion of Zr-MOFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

A bending test protocol for characterizing the mechanical performance of flexible photovoltaics

Flexible photovoltaics (PV) represents a promising research field with great potential for wearable, portable, and indoor applications. Significant progress has been made in recent years, with flexible emerging PV reporting power conversion efficiency (PCE) over 24%. Yet, there is a need for a unifying protocol to assess PV performance, compare research results, and evaluate the state- of-the-art achievements in flexible PV. In this paper, a consensus protocol is presented for measuring PCE over 1,000 bending cycles under 1% strain. Moreover, several good practice guidelines are proposed including bending procedures, flexibility testing with and without encapsulation, and ambient conditions during testing (e.g., temperature, humidity, illumination). Notably, the importance of uniform application of bending radius and the testing of parallel and perpendicular orientations of bending axis with respect to the direction of the electric current are emphasized. These recommendations aim to promote consistency in device comparison and allow for better reproducibility.

Fukuda, Kenjiro

Shadow molecular dynamics for flexible multipole models

Shadow molecular dynamics provide an efficient and stable atomistic simulation framework for flexible charge models with long-range electrostatic interactions. Shadow molecular dynamics simulations are driven by approximate “shadow” Born–Oppenheimer potentials for which the exact charges and forces are directly accessible without relying on costly (and approximate) iterative solvers. While previous implementations have been limited to atomic monopole charge distributions, we extend this approach to flexible multipole models. We derive detailed expressions for the shadow energy functions, potentials, and force terms, explicitly incorporating monopole–monopole, dipole–monopole, and dipole–dipole interactions. In our formulation, both atomic monopoles and atomic dipoles are treated as extended dynamical variables alongside the propagation of the nuclear degrees of freedom. We demonstrate that introducing the additional dipole degrees of freedom preserves the stability and accuracy previously seen in monopole-only shadow molecular dynamics simulations. In addition, we present a shadow molecular dynamics scheme where the monopole charges are held fixed while the dipoles remain flexible. Our extended shadow dynamics provide a framework for stable, computationally efficient, and versatile molecular dynamics simulations involving long-range interactions between flexible multipoles. This is of particular current interest in combination with machine-learned interatomic potentials, including long-range electrostatic interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION

Investigation of the Effect of Framework Flexibility on Adsorption in SIFSIX-3-Cu using a Machine-Learned Force Field

Metal-organic frameworks (MOFs) are a promising class of adsorbents. The performance of MOF sorbents relies on high selectivity and low regeneration energy. This work focuses on the use of machine learned force fields (MLFFs) to model adsorption in a flexible MOF, SIFSIX-3-Cu. A DeePMD-based MLFF was trained to reproduce DFT (PBE+D3) energies, forces, and stresses, using an iterative sampling scheme combining sampling based on molecular dynamics, Monte Carlo, and geometry optimization to capture both attractive and repulsive regions of the potential energy surface. Flexibility of the MOF was explicitly included in this model. Hybrid Monte Carlo/molecular dynamics (MC/MD) simulations using the MLFF predicted adsorption isotherms in good agreement with experimental data for a range of pressures (40 Pa – 104 Pa) in contrast to rigid models, which overpredict CO2 adsorption at low pressures. The improvement was the result of a description of the variability of fluorine-fluorine diagonal distances at adsorption sites. This detailed description of flexibility afforded by the MLFF resulted in more accurate predictions adsorption isotherms when compared to the experimentally measured values. These results underscore the importance of including framework flexibility when modeling adsorption phenomena in MOFs, particularly for low pressure applications and provide a robust procedure for training MLFF models for MOFs.

Atomistic Simulation

Rigid-body motion extracted from total motion of a flexible body

Control system eliminates or reduces flexibility effects on the manual and automatic control of large flexible vehicles. It extracts rigid-body and flexible-body motion and adapts well when a flexible-body frequency coincides or nearly coincides with the control mode frequency.

Howard, J. C.

Stability and CMG wobble damping of flexible, spinning space stations.

Consideration of the uncontrolled vehicle stability and control moment gyro (CMG) wobble damping of two typical modular-spinning-space-station configurations. General stability trends are established as a function of structural parameters. Results of investigations using a unique CMG wobble damping concept are presented, and requirements are formulated. Modifications to the basic control law required as a result of structural flexibility are described. The majority of the analyses were performed with the aid of a digital simulation of the flexible body dynamics. The description of the vehicles, the flexible body simulation, and the CMG wobble damping concept are presented. Previously established theory is supported insofar as the stabilization and control problems associated with a minimum inertia type spinning spacecraft are shown to be significantly greater than those of a maximum inertia vehicle. For example, the maximum inertia configuration investigated is stable for all structural flexibility conditions studied, while the stability of the minimum inertia configuration is dependent upon the distribution of energy dissipating material throughout the structure.

Berman, H.

Deployable flexible ventral fins for use as an emergency spin recovery device in aircraft

A flexible fin device for mounting on an aircraft to effect spin recovery is described. The device may be selectively deployed to provide a triangular planform of flexible material to provide spin recovery, and retracted for compact storage during non-use. A single flexible fin may be deflected in a specific direction depending on direction of spin rotation, or two flexible fins forming an inverted V configuration may be used. The device is mounted on the underbody of the aircraft.

Burk, S. M., Jr.

Attitude control of a spinning flexible spacecraft

The dynamics of rotational motion of a spinning orbiting spacecraft consisting of two rigid bodies connected by a flexible joint and arbitrary number of flexible appendages (two of which are flexible massless booms having masses on their tips) is analyzed. Active attitude control is provided by momentum exchange devices (e.g. control moment gyroscopes) or a mass expulsion system. The linearized equations of motion describing the vehicle are presented, and a large scale digital simulation that has been developed at the Marshall Space Flight Center is presented. A simplified model of the geometrically complex vehicle is selected to make it analytically tractable. The simplified model consists of a single rigid core body with two attached flexible massless booms having tip masses. The states of the vehicle are defined as small perturbations about its steady-state spin. An analysis is performed to determine the domain of stability.

Seltzer, S. M.

Flexible bulb large storage box hydrogen maser

The principal limitation on the accuracy of the hydrogen maser as a primary frequency standard has been the irreproducibility of the frequency shift caused by collisions of the radiating atoms with the walls of the vessel containing them. The flexible bulb-large storage box hydrogen maser allows correction for this wall shift within a single device, sidestepping the reproducibility problem, and reducing the frequency error from the wall shift to the level imposed by the device's stability. The principles of the device are discussed including the flexible bulb technique and the complications caused by a multiple region storage bulb. The stability of the device is discussed including a comparison with an ordinary hydrogen maser. Data is presented from a working flexible bulb-large storage box hydrogen maser demonstrating the feasibility of the device and showing some of its operating characteristics. The flexibility of the device is demonstrated by showing how the device's added degrees of freedom allow measurement of parameters unmeasurable in an ordinary hydrogen maser.

Reinhardt, V.

A vector-dyadic development of the equations of motion for N-coupled flexible bodies and point masses

The equations of motion for a system of coupled flexible bodies, rigid bodies, point masses, and symmetric wheels were derived. The equations were cast into a partitioned matrix form in which certain partitions became nontrivial when the effects of flexibility were treated. The equations are shown to contract to the coupled rigid body equations or expand to the coupled flexible body equations all within the same basic framework. Furthermore, the coefficient matrix always has the computationally desirable property of symmetry. Making use of the derived equations, a comparison was made between the equations which described a flexible body model and those which described a rigid body model of the same elastic appendage attached to an arbitrary coupled body system. From the comparison, equivalence relations were developed which defined how the two modeling approaches described identical dynamic effects.

Frisch, H. P.

Development of flexible rotor balancing criteria

Several studies in which analytical procedures were used to obtain balancing criteria for flexible rotors are described. General response data for a uniform rotor in damped flexible supports were first obtained for plain cylindrical bearings, tilting pad bearings, axial groove bearings, and partial arc bearings. These data formed the basis for the flexible rotor balance criteria presented. A procedure by which a practical rotor in bearings could be reduced to an equivalent uniform rotor was developed and tested. It was found that the equivalent rotor response always exceeded to practical rotor response by more than sixty percent for the cases tested. The equivalent rotor procedure was then tested against six practical rotor configurations for which data was available. It was found that the equivalent rotor method offered a procedure by which balance criteria could be selected for practical flexible rotors, using the charts given for the uniform rotor.

Walter, W. W.