Search NASASearch

SEARCH · Search NASA

Results for “flexure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Strain-energy-release rate analysis of the end-notched flexure specimen using the finite-element method

Two-dimensional finite-element analysis of the end-notched flexure specimen was performed using 8-node isoparametric, parabolic elements to evaluate compliance and mode II strain energy release rates, G sub II. The G sub II values were computed using two different techniques: the virtural crack-closure technique (VCCT) and the rate of change of compliance with crack length (compliance derivative method). The analysis was performed for various crack-length-to-semi-span (a/L) ratios ranging from 0.2 to 0.9. Three material systems representing a wide range of material properties were analyzed. The compliance and strain energy release rates of the specimen calculated with the present finite-element analysis agree very well with beam theory equations including transverse shear. The G sub II values calculated using the compliance derivative method compared extremely well with those calculated using the VCCT. The G sub II values obtained by the compliance derivative method using the top or bottom beam deflections agreed closely with each other. The strain energy release rates from a plane-stress analysis were higher than the plane-strain values by only a small percentage, indicating that either assumption may be used in the analysis. The G sub II values for one material system calculated from the finite-element analysis agreed with one solution in the literature and disagreed with the other solution in the literature.

Salpekar, S. A.

Effect of axial impact on the static flexure of graphite/epoxy beams

Graphite-epoxy beams were subjected to an eccentric axial impact load in a drop tower test fixture in order to study their large displacement flexural behavior. The time history of the transient axial load exhibited a large magnitude occurring just after impact, which was many times greater than the static failure load. The damage caused by this peak dynamic load was measured by the reduction in energy absorption of the impacted beam relative to a virgin beam in static tests. For the thirty-ply specimens, the amount of damage increased with increasing axial stiffness.

Sensmeier, M. D.

Strain energy release rate analysis of the end-notched flexure specimen using the finite-element method

Two-dimensional finite-element analysis of the end-notched flexure specimen was performed using 8-node isoparametric, parabolic elements to evaluate compliance and mode II strain energy release rates, G sub II. The G sub II values were computed using two different techniques: the virtual crack-closure technique (VCCT) and the rate of change of compliance with crack length (compliance derivative method). The analysis was performed for various crack-length-to-semi-span (a/L) ratios ranging from 0.2 to 0.9. Three material systems representing a wide range of material properties were analyzed. The compliance and strain energy release rates of the specimen calculated with the present finite-element analysis agree very well with beam theory equations including transverse shear. The G sub II values calculated using the compliance derivative method compared extremely well with those calculated using the VCCT. The G sub II values obtained by the compliance derivative method using the top or bottom beam deflections agreed closely with each other. The strain energy release rates from a plane-stress analysis were higher than the plane-strain values by only a small percentage, indicating that either assumption may be used in the analysis. The G sub II values for one material system calculated from the finte-element analysis agreed with one solution in the literature and disagreed with the other solution in the literature.

Salpekar, S. A.

Reliability analysis of structural ceramics subjected to biaxial flexure

The reliability of alumina disks subjected to biaxial flexure is predicted on the basis of statistical fracture theory using a critical strain energy release rate fracture criterion. Results on a sintered silicon nitride are consistent with reliability predictions based on pore-initiated penny-shaped cracks with preferred orientation normal to the maximum principal stress. Assumptions with regard to flaw types and their orientations in each ceramic can be justified by fractography. It is shown that there are no universal guidelines for selecting fracture criteria or assuming flaw orientations in reliability analyses.

Chao, Luen-Yuan

Study of flexural rigidity of weavable powder-coated towpreg

An effort has been made to weave powder-impregnated tow into a two-dimensional preform, controlling process variables to obtain high flexural rigidity in the warp direction and greater flexibility in the fill direction. The resulting prepregs have been consolidated into laminates with LaRC-TPI matrices. Complementary SEM and DSC studies have been performed to deepen understanding of the relationship between tow flexibility and heat treatment. Attention is also given to the oven temperature and residence time variables' effects on power/fiber fusion.

Hirt, Douglas E.

Measurement of multiaxial ply strength by an off-axis flexure test

An off-axis flexure (OAF) test was performed to measure ply strength under multiaxial stress states. This test involves unidirectional off-axis specimens loaded in bending, using an apparatus that allows these anisotropic specimens to twist as well as flex without the complications of a resisting torque. A 3D finite element stress analysis verified that simple beam theory could be used to compute the specimen bending stresses at failure. Unidirectional graphite/epoxy specimens with fiber angles ranging from 90 deg to 15 deg have combined normal and shear stresses on their failure planes that are typical of 45 deg plies in structural laminates. Tests for a range of stress states with AS4/3501-6 specimens showed that both normal and shear stresses on the failure plane influenced cracking resistance. This OAF test may prove to be useful for generating data needed to predict ply cracking in composite structures and may also provide an approach for studying fiber-matrix interface failures under stress states typical of structures.

Crews, John H., Jr.

Damage mechanisms in three-dimensional woven reinforced ceramic matrix composites under tensile and flexural loading at room and elevated temperatures

Three-dimensional Nicalon SiC/SiC matrix composites made through a chemical vapor infiltration process were studied under tensile and flexural loading at 23, 1200, and 1550 C in air. In situ damage accumulation monitoring NDE techniques were utilized to identify failure mechanisms in these materials. The effectiveness and durability of a chemical vapor deposition SiC surface coating were also evaluated in severe oxidizing environment. Results show that the failure response was very similar for the 23 and 1200 C specimens, while at 1550 C there were significant changes in both the composite mechanical behavior and the matrix microstructure. Extensive fiber pull-out was observed only in the 1550 C specimen. It is also found that the SiC surface coating can protect the composite up to the critical matrix cracking strength.

Chulya, Abhisak

Modeling of the flexural behavior of ceramic-matrix composites

This paper examines the effects of matrix cracking and fiber breakage on the flexural behavior of ceramic composite beams. A model has been proposed to represent the damage evolution of the beam, of which the matrix fracture strain is smaller than that of the fibers. Close form solutions of the critical loads for the initiation of matrix cracking and fiber breakage in the tension side of the beam have been found. The effects of thermal residual stresses and fiber/matrix debonding have been taken into account. The initial deviation of the load-deflection curve from linearity is due to matrix cracking, while fiber breakages are responsible for the drop in the load carrying capacity of the beam. The proportional limit as well as the nonlinear behavior of the beam deflection have been identified. The growth of the damaged zone has also been predicted. A three-point bending case is given as a numerical example.

Kuo, Wen-Shyong

Flexure Test For Off-Axis Unidirectional Composites

Improved flexure test yields data on ply strength of off-axis unidirectional composite material. Rotatable end supports allow ends of specimen to twist freely. End supports apply only vertical loads, making simple three-point bending test. Ply-strength data provide basis for predicting onset of damage in composite structures and serve as measure of fiber-matrix adhesion.

Crews, John H., Jr.

Brush seal bristle flexure and hard-rub characteristics

The bristles of a 38.1-mm (1.5-in) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping,' and hot spots and streaks were found. With a smooth-plug rotor post-test leakage increased 30 percent over pretest leakage.

Hendricks, Robert C.

Extensional and flexural waves in a thin-walled graphite/epoxy tube

Simulated acoustic emission signals were induced in a thin-walled graphite/epoxy tube by means of lead breaks (Hsu-Nielsen source). The tube is of similar material and layup to be used by NASA in fabricating the struts of Space Station Freedom. The resulting waveforms were detected by broad band ultrasonic transducers and digitized. Measurements of the velocities of the extensional and flexural modes were made for propagation directions along the tube axis (0 degrees), around the tube circumference (90 degrees) and at an angle of 45 degrees. These velocities were found to be in agreement with classical plate theory.

Prosser, William H.

Flexure-torsion behavior of prismatic beams. I - Section properties via power series

The behavior of a tip-loaded cantilever beam with an arbitrary cross section is studied using Saint-Venant's semi-inverse method along with a power series solution for the out-of-plane flexure and torsion warping functions. The power series coefficients are determined by solving a set of variationally derived linear algebraic equations. For complex cross sections, the calculated coefficients represented a 'best-fit approximation' to the exact warping function. The resulting warping functions are used to determine the cross-sectional properties (torsion constant, shear correction factors, shear deformation coefficients, and shear center location). A new linear relation is developed for locating the shear center, where the twist rate is zero about the line of shear centers. Moreover, the kinematic relations for a new fully compatible one-dimensional beam theory are developed. Numerical results are presented first to verify the approach and second to provide section data on NACA four-series airfoils not currently found in the literature.

Kosmatka, J. B.

Scale effects in the response and failure of fiber reinforced composite laminates loaded in tension and in flexure

The feasibility of using scale model testing for predicting the full-scale behavior of flat composite coupons loaded in tension and beam-columns loaded in flexure is examined. Classical laws of similitude are applied to fabricate and test replica model specimens to identify scaling effects in the load response, strength, and mode of failure. Experiments were performed on graphite-epoxy composite specimens having different laminate stacking sequences and a range of scaled sizes. From the experiments it was deduced that the elastic response of scaled composite specimens was independent of size. However, a significant scale effect in strength was observed. In addition, a transition in failure mode was observed among scaled specimens of certain laminate stacking sequences. A Weibull statistical model and a fracture mechanics based model were applied to predict the strength scale effect since standard failure criteria cannot account for the influence of absolute specimen size on strength.

Jackson, Karen E.

Propagation of flexural mode AE signals in GR/EP composite plates

A Fourier phase technique has been used to measure the dispersion of the flexural plate mode in graphite-epoxy composite laminates. Classical plate theory is shown to be of limited value in predicting the dispersion of this mode because it assumes that the effects of shear deformation and rotatory inertia are negligible. Higher-order plate theory, which includes these effects, gives much better agreement with measured values.

Prosser, W. H.

Wind-tunnel Investigations on Flexural-torsional Wing Flutter

For the purpose of testing the theory of an oscillating airfoil of two degrees of freedom, a wing was mounted in the wind tunnel between two walls in such a manner that it could execute vertical (flexural) oscillations as well as torsional oscillations about an arbitrary axis parallel to the span. It was possible to vary the inertia and elasticity parameters and also to increase artificially the negligibly small natural damping of the system. The oscillations were recorded to a strongly magnified scale. The experimentally determined critical (or flutter) velocities fully agree with the theoretical ones of Wagner and Kussner within the limits of computational and measuring accuracy. An extremely narrow wing without end walls (three dimensional problem) showed the same oscillations as one with end walls (two-dimensional problem).

Voigt, H

Brush seal bristle flexure and hard-rub characteristics

The bristles of a 38.1-mm (1.5-in.) diameter brush seal were flexed by a tapered, 40-tooth rotor operating at 2600 rpm that provided sharp leading-edge impact of the bristles with hard rubbing of the rotor lands. Three separate tests were run with the same brush accumulating over 1.3 x 10(exp 9) flexure cycles while deteriorating 0.2 mm (0.008 in.) radially. In each, the test bristle incursion depth varied from 0.130 to 0.025 mm (0.005 to 0.001 in.) or less (start to stop), and in the third test the rotor was set 0.25 mm (0.010 in.) eccentric. Runout varied from 0.025 to 0.076 mm (0.001 to 0.003 in.) radially. The bristles wore but did not pull out, fracture, or fragment. Bristle and rotor wear debris were deposited as very fine, nearly amorphous, highly porous materials at the rotor groove leading edges and within the rotor grooves. The land leading edges showed irregular wear and the beginning of a convergent groove that exhibited sharp, detailed wear at the land trailing edges. Surface grooving, burnishing, 'whipping', and hot spots and streaks were found. With a smooth-plug rotor, post-test leakage increased 30 percent over pretest leakage.

Hendricks, Robert C.

Mode 1 and Mode 2 Analysis of Graphite/Epoxy Composites Using Double Cantilever Beam and End-Notched Flexure Tests

The critical strain energy release rates associated with debonding of the adhesive bondlines in graphite/epoxy IM6/3501-6 interlaminar fracture specimens were investigated. Two panels were manufactured for this investigation; however, panel two was layed-up incorrectly. As a result, data collected from Panel Two serves no real purpose in this investigation. Double Cantilever Beam (DCB) specimens were used to determine the opening Mode I interlaminar fracture toughness, G1(sub c), of uni-directional fiber re-inforced composites. The five specimens tested from Panel One had an average value of 946.42J/sq m for G1(sub c) with an acceptable coefficient of variation. The critical strain energy release rate, G2(sub c), for initiation of delamination under inplane shear loading was investigated using the End-Notched Flexure (ENF) Test. Four specimens were tested from Panel One and an average value of 584.98J/sq m for G2(sub c) was calculated. Calculations from the DCB and ENF test results for Panel One represent typical values of G1(sub c) and G2(sub c) for the adhesive debonding in the material studied in this investigation.

Hufnagel, Kathleen P.

Evaluation of Relative Sensitivity of SAW and Flexural Plate Wave Devices for Atmospheric Sensing

The objective of this project is to evaluate the suitability of the ultrasonic flexural plate wave (FPW) device as the detector in a gas chromatograph (GC). Of particular interest is the detection of nitrous oxide (N2O). From experimental results we conclude analyte detection is achieved through two mechanisms: changes in gas density, and mass loading of the device membrane due to the sorption of gas molecules. Reducing the dead volume of the FPW chamber increased the FPW response. A comparison of the FPW response to that of the surface acoustic wave (SAW) detector provided with the GC (made by MSI, Microsensor Technologies, Inc.), shows that for unseparated N2O in N2, the FPW exhibits a sensitivity that is at least 550 times greater than that of the SAW device. A Porapak Q column was found to separate N2O from its carrier gas, N2 or He. With the Porapak Q column, a coated FPW detected 1 ppm N2O in N2 or He, with a response magnitude of 7 Hz. A coated SAW exhibited a response of 25 Hz to pure N2O. The minimal detectable N2O concentrations of the sensors were not evaluated.

White, Richard M.