Search NASA⌕ Search

SEARCH · Search NASA

Results for “flight experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Cloud Droplet Measurement System for the ARM Tethered Balloon System (TBS) Field Campaign Report

The Mesa Photonics' cloud droplet measurement system (CDMS) performs in situ measurement of droplet size distribution and droplet number density in clouds. These characteristics are important cloud microphysical properties that are critical input parameters for atmospheric models and are also useful for proper calibration and validation of performance of other atmospheric measurement instrumentation. This small campaign was the first project (out of two) that involved integration of the CDMS into the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s tethered balloon system (TBS) and its initial testing at the ARM Southern Great Plains (SGP) atmospheric observatory. The follow-up campaign (AFC07016) involved testing of the CDMS under relevant conditions at the third ARM Mobile Facility (AMF3) at Oliktok Point, Alaska and making in situ measurements in clouds. The goal of this small field campaign was to deploy the CDMS on the ARM TBS, demonstrate its integrity and compatibility with the TBS, and test the wireless telecommunication system in preparation for subsequent in-cloud measurements at ARM’s North Slope of Alaska (NSA) observatory at Utqiagvik (formerly Barrow). The specific technical objectives included: (1) Integration of the Mesa Photonics' CDMS into the ARM TBS, (2) testing of the wireless telecommunication system of the CDMS, (3) evaluating the data acquisition software and image processing algorithms especially under high-background-illumination conditions, and (4) testing the ruggedness of the instrument's optical alignment and other performance characteristics. All objectives have been successfully met. The mounting hardware was designed and built mostly at Sandia National Laboratories (SNL), which allowed reliable mounting of the CDMS on the TBS and co-locating the CDMS with other instruments. The field tests were performed by the principal investigator (PI) in collaboration with the TBS operational crew led by D. Dexheimer. The field testing demonstrated good compatibility of the CDMS with the TBS. During the TBS flights, the crew did not experience any operational issues with the CDMS. The instrument demonstrated reliable operational characteristics, including sufficient battery life and good thermal management. The wireless telecommunication system has been successfully tested at TBS flight altitudes of up to 1000 m. During all flights, the CDMS raw data were wirelessly transmitted to the ground station and processed in real time. The ruggedness of the instrument's optical alignment was evaluated by performing calibration of the CDMS (using Mesa Photonics' fixed-size monodisperse droplet generator) before and after the campaign. The calibration was stable within the instrument's measurement precision. In summary, the campaign demonstrated good compatibility of the Mesa Photonics' CDMS with the ARM TBS. The flight tests confirmed the mechanical integrity of the CDMS and stability of its optical layout, as well as reliability of the wireless telecommunication system. Successful completion of this campaign provided a solid basis for the next campaign (AFC07016, November 2020), that involved testing of the CDMS during in-cloud TBS flights at AMF3 at Oliktok Point.

54 ENVIRONMENTAL SCIENCES↗

On the instrument-dependent appearance of ion dissociation events in atom probe tomography mass spectra

The successful application of atom probe tomography (APT) relies on the accurate interpretation of the mass spectrum (i.e. m/z histogram) from a sample. Some materials yield mass spectra that are amenable to a straightforward peak assignment/ranging, however, there are many materials that produce mass spectra with features that defy simple interpretation. One such example is Ga 2 O 3 which yields mass spectra containing several broad and difficult to interpret features. Herein, we study the GaO 2+ → O 1+ + Ga 1+ dissociation and we explain how this dissociation process gives rise to broad and previously unassigned features in the mass spectrum. Trajectory simulations are performed for the dissociation reaction utilizing realistic electrostatic models and compared to experiments using commercially available straight flight and reflectron based local electrode (LE) APT instruments. It is shown that the appearance of these features is strongly dependent on the specific design of the time-of-flight (ToF) mass analyzer. Additionally, we explore how various experimental parameters can affect the appearance of the dissociation process in the one-dimensional (1D) mass spectrum and in the two-dimensional (2D) correlation histogram. While the focus of this work is on a particular dissociation process related to Ga 2 O 3 , the understanding gained in the course of these simulations and experiments should be applicable to the interpretation of dissociation processes in other materials.

47 OTHER INSTRUMENTATION↗

Implosion shape control of high-velocity, large case-to-capsule ratio beryllium ablators at the National Ignition Facility

Experiments at the National Ignition Facility (NIF) show that the implosion shape of inertial confinement fusion ablators is a key factor limiting performance. To achieve more predictable, shape tunable implosions, we have designed and fielded a large 4.2 case-to-capsule ratio target at the NIF using 6.72 mm diameter Au hohlraums and 1.6 mm diameter Cu-doped Be capsules. Simulations show that at these dimensions during a 10 ns 3-shock laser pulse reaching 275 eV hohlraum temperatures, the plasma flow from the hohlraum wall and ablator is not significant enough to impede beam propagation. Experiments measuring the shock symmetry and in-flight shell symmetry closely matched the simulations. Most notably, in two experiments, we demonstrated symmetry control from negative to positive Legendre P2 space by varying the inner to total laser power cone fraction by 5% below and above the predicted symmetric value. In conclusion, some discrepancies found in 1st shock arrival times that could affect agreement in late time implosion symmetry suggest hohlraum and capsule modeling uncertainties do remain, but this target design reduces sensitivities to them.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of the Parity of the Neutral Pion via Its Four-Electron Decay

We present a new determination of the parity of the neutral pion via the double Dalitz decay {pi}{sup 0}{yields}e{sup +}e{sup -}e{sup +}e{sup -}. Our sample, which consists of 30 511 candidate decays, was collected from K{sub L}{yields}{pi}{sup 0}{pi}{sup 0}{pi}{sup 0} decays in flight at the KTeV-E799 experiment at Fermi National Accelerator Laboratory. We confirm the negative {pi}{sup 0} parity and place a limit on scalar contributions to the {pi}{sup 0}{yields}e{sup +}e{sup -}e{sup +}e{sup -} decay amplitude of less than 3.3% assuming CPT conservation. The {pi}{sup 0}{gamma}*{gamma}* form factor is well described by a momentum-dependent model with a slope parameter fit to the final state phase-space distribution. Additionally, we have measured the branching ratio of this mode to be B({pi}{sup 0}{yields}e{sup +}e{sup -}e{sup +}e{sup -})=(3.26{+-}0.18)x10{sup -5}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of the plasma density in the FTU tokamak by a pulsed time-of-flight X-wave refractometer

On-line control over the plasma density in tokamaks (especially, in long-term discharges) requires reliable measurements of the averaged plasma density. For this purpose, a new method of density measurements-a pulsed time-of-flight plasma refractometry-was developed and tested in the T-11M tokamak. This method allows one to determine the averaged density from the measured time delay of nanosecond microwave pulses propagating through the plasma. For an O-wave, the measured time delay is proportional to the line-averaged density and is independent of the density profile (f>>f{sub p}) {tau}{sub o} {approx} k{sub o} 1/f{sup 2} {integral}{sub l} N(x)dx. Here, f is the frequency of the probing wave, f{sub p} is the plasma frequency, l= 4 a is the path length for two-pass probing in the equatorial plane, a is the plasma minor radius, k{sub O} and k{sub X} are numerical factors, f{sub c} is the electron-cyclotron frequency at the axis of the plasma column, and f{sub p}>>f{sub c}, f. Measurements of the time delay provide the same information as plasma interferometry, though they do no employ the effect of interference. When the conditions f{sub p}>>f{sub c}, f are not satisfied, the measured time delay depends on the shape of the density profile. In this case, in order to determine the average density regardless of the density profile, it is necessary to perform simultaneous measurements at several probing frequencies in order to determine the average density. In ITER (Bt {approx} 5T), a spectral window between the lower and upper cutoff frequencies in the range of 50-100 GHz can be used for pulsed time-of-flight X-wave refractometry. This appreciably simplifies the diagnostics and eliminates the problem of the first mirror. In this paper, the first results obtained in the FTU tokamak with a prototype of the ITER pulsed time-of-flight refractometer are presented. The geometry and layout of experiments similar to the planned ITER experiments are described. The density measured by pulsed time-of-flight refractometry is shown to agree well with the results obtained in FTU with a two-frequency scanning IR interferometer. The results obtained are analyzed, and the future experiments are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Addressing the Amorphous Content Issue in Quantitative Phase Analysis: The Certification of NIST Standard Reference Material 676a

A non-diffracting surface layer exists at any boundary of a crystal and can comprise a mass fraction of several percent in a finely divided solid. This has led to the long-standing issue of amorphous content in standards for quantitative phase analysis (QPA). NIST standard reference material (SRM) 676a is a corundum ({alpha}-Al{sub 2}O{sub 3}) powder, certified with respect to phase purity for use as an internal standard in powder diffraction QPA. The amorphous content of SRM 676a is determined by comparing diffraction data from mixtures with samples of silicon powders that were engineered to vary their specific surface area. Under the (supported) assumption that the thickness of an amorphous surface layer on Si was invariant, this provided a method to control the crystalline/amorphous ratio of the silicon components of 50/50 weight mixtures of SRM 676a with silicon. Powder diffraction experiments utilizing neutron time-of-flight and 25 keV and 67 keV X-ray energies quantified the crystalline phase fractions from a series of specimens. Results from Rietveld analyses, which included a model for extinction effects in the silicon, of these data were extrapolated to the limit of zero amorphous content of the Si powder. The certified phase purity of SRM 676a is 99.02% {+-} 1.11% (95% confidence interval). This novel certification method permits quantification of amorphous content for any sample of interest, by spiking with SRM 676a.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Versatile attosecond beamline in a two-foci configuration for simultaneous time-resolved measurements

We present our attoline which is a versatile attosecond beamline at the Ultrafast Laser Physics Group at ETH Zurich for attosecond spectroscopy in a variety of targets. High-harmonic generation (HHG) in noble gases with an infrared (IR) driving field is employed to generate pulses in the extreme ultraviolet (XUV) spectral regime for XUV-IR cross-correlation measurements. The IR pulse driving the HHG and the pulse involved in the measurements are used in a non-collinear set-up that gives independent access to the different beams. Single attosecond pulses are generated with the polarization gating technique and temporally characterized with attosecond streaking. This attoline contains two target chambers that can be operated simultaneously. A toroidal mirror relay-images the focus from the first chamber into the second one. In the first interaction region a dedicated double-target allows for a simple change between photoelectron/photoion measurements with a time-of-flight spectrometer and transient absorption experiments. Any end station can occupy the second interaction chamber. A surface analysis chamber containing a hemispherical electron analyzer was employed to demonstrate successful operation. Simultaneous RABBITT measurements in two argon jets were recorded for this purpose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring higher-order moments of neutron-time-of-flight data for cryogenic inertial confinement fusion implosions on OMEGA

Ion temperatures serve as an important diagnostic for inertial confinement fusion (ICF) implosions. In direct-drive ICF experiments on OMEGA, neutron-time-of-flight (nTOF) data are used to infer the ion temperature of the fusing plasma produced in the implosion experiment. The analysis of the nTOF data requires an assumption about the shape of the underlying source signal. Since the source nTOF signal is a near-replica of the neutron energy spectrum, an ideal Gaussian shape, corresponding to the neutron energy spectrum of a uniform temperature plasma, is routinely employed. However, spatial and temporal variations of the ion temperature in the plasma give rise to higher-order moments, which were first described by Munro [Nucl. Fusion 56, 036001 (2016)]. In this work, we show a simpler alternative analysis to derive moments of the neutron energy spectrum for a plasma with variations in ion temperature. We also present a revised analysis of measured nTOF signals that uses a model with an additional degree of freedom to take into account the effect of ion temperature variations on the shape of the spectrum. Compared to presently used nTOF analysis, the revised analysis yields on average ≈2× more accurate fits to the data and up to 15% higher ion temperatures for cryogenic experiments. As a result, we quantify the ion temperature inflation caused by radially symmetric fluid flows, which are present even in a symmetric implosion, and which serve as a lower bound on the ion temperature inflation in real implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heating experiments of the Tagish Lake meteorite: Investigation of the effects of short-term heating on chondritic organics

We present in this study the effects of short-term heating on organics in the Tagish Lake meteorite and how the difference in the heating conditions can modify the organic matter (OM) in a way that complicates the interpretation of a parent body's heating extent with common cosmothermometers. The kinetics of short-term heating and its influence on the organic structure are not well understood, and any study of OM is further complicated by the complex alteration processes of the thermally metamorphosed carbonaceous chondrites—potential analogues of the target asteroid Ryugu of the Hayabusa2 mission—which had experienced posthydration, short-duration local heating. In an attempt to understand the effects of short-term heating on chondritic OM, we investigated the change in the OM contents of the experimentally heated Tagish Lake meteorite samples using Raman spectroscopy, scanning transmission X-ray microscopy utilizing X-ray absorption near edge structure spectroscopy, and ultraperformance liquid chromatography fluorescence detection and quadrupole time of flight hybrid mass spectrometry. Our experiment suggests that graphitization of OM did not take place despite the samples being heated to 900 °C for 96 h, as the OM maturity trend was influenced by the heating conditions, kinetics, and the nature of the OM precursor, such as the presence of abundant oxygenated moieties. Although both the intensity of the 1s-σ* exciton cannot be used to accurately interpret the peak metamorphic temperature of the experimentally heated Tagish Lake sample, the Raman graphite band widths of the heated products significantly differ from that of chondritic OM modified by long-term internal heating.

Chan, Queenie H. S.↗

Gallium oxide semiconductor-based large volume ultrafast radiation hard spectroscopic scintillators

We report on the development of the first-ever inorganic radiation-hard moisture-insensitive large volume spectroscopic semiconductor-based scintillator with less than 2 ns decay time and light yields as high as 8000 ph/MeV. Despite extensive research into scintillator materials, the quest for an ideal scintillator combining ultrafast decay times (akin to BaF 2 and Yb-doped scintillators such as Lu 2 O 3 :Yb), high light yields (exceeding 2000 photons per MeV), spectroscopic capabilities, and exceptional radiation hardness remain unfulfilled. In this study, we demonstrate and report for the first time the viability of large-volume (up to 20 mm thickness) gallium oxide (β-Ga 2 O 3 ) semiconductor-based scintillators for applications requiring these properties. These β-Ga 2 O 3 scintillators were grown using the fast turnaround (~2 days) crucible-free optical float zone (FZ) technique. The high light yield and ultrafast decay time of these high-purity n-type semiconductors with free carrier concentration of 6 × 10 17 cm –3 are attributed to native defects, specifically oxygen vacancies (V O ) and gallium–oxygen vacancy pairs (V Ga –V O ), generated during optimized FZ growth. The ultrafast decay, along with high light yield, enables excellent timing resolution and high count rate detection for applications like time-of-flight positron emission tomography, physics experiments, and nuclear safety. The radiation hardness of these devices has been documented in a separate publication.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pr{sup 3+}-doped fluoro-oxide lithium glass as scintillator for nuclear fusion diagnostics

Experimental results are presented on the neutron scintillating properties of a custom-designed Pr3+(praseodymium)-doped lithium (Li) glass. Luminescence was observed at 278 nm wavelength, originating from the 5d-4f transition. Time-resolved measurements yielded about 20 ns decay times for ultraviolet and x-ray excitation while much faster decay times of about 6 ns were observed for alpha particle and neutron excitation. Actual time-of-flight data in laser fusion experiments at the GEKKO XII facility of the Institute of Laser Engineering, Osaka University reveal that it can clearly discriminate fusion neutrons from the much stronger x-rays signals. This material can promise improved accuracy in future scattered neutron diagnostics.

36 MATERIALS SCIENCE↗

Mixing in ICF implosions on the National Ignition Facility caused by the fill-tube

The micrometer-scale tube that fills capsules with thermonuclear fuel in inertial confinement fusion experiments at the National Ignition Facility is also one of the implosion's main degradation sources. It seeds a perturbation that injects the ablator material into the center, radiating away some of the hot-spot energy. This paper discusses how the perturbation arises in experiments using high-density carbon ablators and how the ablator mix interacts once it enters the hot-spot. Both modeling and experiments show an in-flight areal-density perturbation and localized x-ray emission at stagnation from the fill-tube. Simulations suggest that the fill-tube is degrading an otherwise 1D implosion by ~2×, but when other degradation sources are present, the yield reduction is closer to 20%. Characteristics of the fill-tube assembly, such as the through-hole size and the glue mass, alter the dynamics and magnitude of the degradation. Overall, these aspects point the way toward improvements in the design, some of which (smaller diameter fill-tube) have already shown improvements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of magnetic field on laser-produced barium plasmas: Spectral and dynamic behaviour of neutral and ionic species

The expansion dynamics and spectral behaviour of plasma produced by a Nd:YAG laser (λ=1.064 μm, pulse width: 8 ns) from barium target and expanding in 0.45 T transverse magnetic field in vacuum (10⁻⁵Torr pressure) are investigated using time-of-flight optical emission spectroscopy. The experiments are carried out at various laser fluences from 12 to 31 J/cm². The temporal profiles of neutral (Ba I 553.5 and 577.7 nm) lines are temporally broadened, while that of ionic (Ba II 413.0 and 455.4 nm) lines show strong confinement in the presence of a magnetic field. In the absence of magnetic field, the temporal profile of Ba I 553.5 nm is exactly reproduced by fitting with two Shifted Maxwell Boltzmann (SMB) Distribution components, while in the presence of a magnetic field the profile could only be fitted with three components. The field enhanced and field induced SMB components of neutral profile are correlated with populations of ground state, metastable states, and long-lived Rydberg states present in the barium plasma, while SMB components of ionic lines are explained on the basis of the presence of super-elastic collisions among the excited species in the plasma. The spatial variation of electron temperature and temporal variation of electron density are deduced and correlated to the different collisional processes in the barium plasma. The ionic profiles show efficient confinement in the presence of a magnetic field at higher fluences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental comparison of time-of-flight mass analysis with magnetic mass analysis

A series of experiments was carried out in which both a magnetic analyzer (mass separator) and a time-of-flight (TOF) spectrometer were used for ion charge/mass spectral analysis of the ion beam formed by a dc Bernas ion source made for semiconductor implantation. The TOF analyzer was a detachable device that provides rapid analysis of charge-to-mass composition of moderate energy ion beams. The magnetic analyzer was a massive device using a 90 deg.-sector bending magnet with radius of the central orbit of 35 cm. Comparison of these two methods for measuring ion beam composition shows good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

pathSQE : an automated workflow for single-crystal inelastic neutron scattering data processing and analysis

Inelastic neutron scattering (INS) experiments utilizing modern time-of-flight spectrometers enable the comprehensive mapping of the energy (E)- and momentum (Q)-resolved dynamical structure factor of single crystals, probing both the lattice and magnetic excitations. Yet, the large size and complexity of four-dimensional INS data are challenging current analysis workflows, often resulting in an underutilization of the measured information. To help address this issue, this paper introduces new software interfaced with the Mantid framework, pathSQE, designed to streamline the processing, analysis and interpretation of 4D single-crystal INS data. By automating key tasks such as 1D/2D slicing, symmetrization, Brillouin zone folding, data visualization, prioritization and filtering, and comparisons with simulations, pathSQE facilitates and accelerates INS data analysis workflows. Here, this paper outlines the features and implementation and provides several illustrations of the use of pathSQE on data collected on single crystals using direct-geometry time-of-flight spectrometers at the Spallation Neutron Source, including Ge, FeSi, MnO and SnS single-crystal measurements on the ARCS, HYSPEC and CNCS neutron spectrometers. Beyond streamlining post-experiment data processing, pathSQE establishes an automated and modular processing pipeline that could support future real-time experiment steering.

36 MATERIALS SCIENCE↗