ChemCam on MSL 2009: first laser induced breakdown spectrometer for space science

ChemCam is one of the 10 instrument suites on the Mars Science Laboratory, a martian rover being built by Jet Propulsion Laboratory, for the next NASA mission to Mars (MSL 2009). ChemCam is an instrument package consisting of two remote sensing instruments: a Laser-Induced Breakdown Spectrometer (LIBS) and a Remote Micro-Imager (RMI). LIBS provides elemental compositions of rocks and soils, while the RMI places the LIBS analyses in their geomorphologic context. Both instruments rely on an autofocus capability to precisely focus on the chosen target, located at distances from the rover comprised between 1 and 9 m for LIBS, and 2 m and infinity for RMI. ChemCam will help determine which samples, within the vicinity of the MSL rover, are of sufficient interest to use the contact and in-situ instruments for further characterization. It will provide valuable analyses of samples that are inaccessible to contact and in-situ instruments, and of a much larger number of samples than can be done with this kind of instrument. ChemCam also has a capability to provide passive spectroscopy data of rocks and soils on Mars. ChemCam hardware consists of a Mast Unit (MU), provided by France, and a Body Unit (BU) built and tested in the USA. The Flight Model of the MU is assembled, tested and now available in the USA, while the BU is currently being assembled and tested. Both will be connected by the end of year '08 for end-to-end functional and performance tests, before delivery to JPL and assembly on the MSL rover. Launch is scheduled for October 09. After describing the concept of ChemCam, this presentation focuses on its French part, Mast Unit. The results presented show that Mast Unit is able to generate a plasma and collect its light, over the full applicable ranges of distances and temperatures on Mars.

47 OTHER INSTRUMENTATION↗

FY23 Drone RFID (Final Report)

The Drone RFID project successfully completed proof-of-concept testing to demonstrate the potential of a drone-based inventory system for high value remote materials at Los Alamos National Laboratory. Multiple drone platforms were procured, flight authorizations were received, and the vehicles were flown demonstrating what was initially perceived as the most difficult part of the project, successfully flying drones at the lab. Three commercial RFID inventory systems were also purchased, and ground testing performed to determine their suitability. Ultimately, one system was chosen for flight testing and successfully demonstrated the drone's ability to execute inventory with great potential for a relatively low-cost implementation.

42 ENGINEERING↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Improving SGP4 Orbit Determination with New State Estimation Algorithm

The Simplified General Perturbations 4 Model (SGP4) is a well-known tool for performing satellite orbit determination. However, uncertainties and inaccuracies in the initial state inputs (required by SGP4) degrade the performance of the propagator. We present a new state estimation algorithm that allows for independent computation of these initial inputs using Unscented Kalman Filtering and GPS data from a satellite. The algorithm is tested on real flight data and demonstrates a notable performance improvement over the standard method of orbit determination using SGP4.

97 MATHEMATICS AND COMPUTING↗

Retrieval of Aerosol Optical Depth in Vicinity of Broken Clouds from Reflectance Ratios: Case Study

A recently developed reflectance ratio (RR) method for the retrieval of aerosol optical depth (AOD) is evaluated using extensive airborne and ground-based data sets collected during the Cloud and Land Surface Interaction Campaign (CLASIC) and the Cumulus Humilis Aerosol Processing Study (CHAPS), which took place in June 2007 over the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Southern Great Plains site. A detailed case study is performed for a field of single-layer shallow cumuli observed on June 12, 2007. The RR method is applied to retrieve the spectral values of AOD from the reflectance ratios measured by the MODIS Airborne Simulator (MAS) for two pairs of wavelengths (660 and 470 nm and 870 and 470 nm) collected at a spatial resolution of 0.05 km. The retrieval is compared with an independent AOD estimate from three ground-based Multi-filter Rotating Shadowband Radiometers (MFRSRs). The interpolation algorithm that is used to project MFRSR point measurements onto the aircraft flight tracks is tested using AOD derived from NASA Langley High Spectral Resolution Lidar (HSRL). The RR AOD estimates are in a good agreement (within 5%) with the MFRSR-derived AOD values for the 660-nm wavelength. The AODs obtained from MAS reflectance ratios overestimate those derived from MFRSR measurements by 15-30% for the 470-nm wavelength and underestimate the 870-nm AOD by the same amount.

54 ENVIRONMENTAL SCIENCES↗

Super Strypi HWIL 6DOF (Hardware-In-Loop six-degree-of-freedom) Rev. 2175

The Super Strypi HWIL is a six degree-of-freedom (6DOF) simulation for the Super Strypi Launch Vehicle. The simulation is used to test the NGC flight software including the navigation software. Aerodynamic and propulsive forces, mass properties, ACS (attitude control system) parameters are defined in input files. Output parameters are saved to a Matlab mat file.

Gilkey, Jeff C.↗

Quantifying Turbine-Level Risk to Golden Eagles Using a High-Fidelity Updraft Model and a Stochastic Behavioral Model

To minimize the effects of wind farms on Golden Eagle (Aquila chrysaetos) populations while enabling sustainable development of renewable energy resources, it is important to understand how eagles interact with atmospheric flows, terrain features, and anthropogenic structures. Models that predict migratory flight paths provide one tool that helps us grasp how the location of wind farms may influence interactions and impacts on migrating Golden Eagles. The current state-of-the-art in predicting migratory flight paths uses a deterministic fluid-flow analogy to predict eagle trajectory using only an orographic updraft potential computed from topographical features. This model does not take into account variables, such as thermal updrafts and time varying atmospheric conditions that are known to influence migratory behavior. In this work, we improve on the model with the objective of developing tools that advance our understanding of how atmospheric flows and terrain features affect migratory eagle behavior and their interactions with wind farms. Specifically, we 1) incorporate both orographic and thermal updraft information in simulating eagle flight paths; 2) incorporate stochasticity into eagle travel patterns to better capture the influence of exogenous factors on, and the inherent stochasticity of eagle behavior; 3) consider spatio-temporal atmospheric data at wind-farm-scale when computing updraft potential; and 4) account for how atmospheric conditions and the direction of migration change seasonally and how these changes affect eagle migratory flight behavior. We tested the model using a 50km by 50km region with 50 m resolution in the western United States. We simulated 900 independent, probabilistic eagle tracks during southerly and northerly migration, assuming eagles solely rely on orographic updrafts. The preliminary results indicate that the inclusion of finer resolution atmospheric data allows for the inclusion of realistic conditions that an eagle experiences. The stochasticity in eagle tracks provides a platform to include uncertainty in eagle decision making and help produce robust eagle presence maps. We will deploy updraft and downdraft velocities computed using a high-fidelity, wind farm scale, computational fluid dynamics solver under development at National Renewable Energy Laboratory. This work is a first step in the development of a predictive and generalizable eagle behavior model at the wind farm scale that does not rely on empirical data collection. Although the current model is intended for migratory eagles, we will extend and refine this model to inform the development of additional behavioral modes, including resident eagle behavior. This modeling approach improves our ability to understand eagle use of the landscape at a fine scale, and it is our hope that this work will ultimately help advance strategies that minimize the impact of wind development on Golden Eagle populations.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Calculating system reliability with SRFYDO

SRFYDO is a process for estimating reliability of complex systems. Using information from all applicable sources, including full-system (flight) data, component test data, and expert (engineering) judgment, SRFYDO produces reliability estimates and predictions. It is appropriate for series systems with possibly several versions of the system which share some common components. It models reliability as a function of age and up to 2 other lifecycle (usage) covariates. Initial output from its Exploratory Data Analysis mode consists of plots and numerical summaries so that the user can check data entry and model assumptions, and help determine a final form for the system model. The System Reliability mode runs a complete reliability calculation using Bayesian methodology. This mode produces results that estimate reliability at the component, sub-system, and system level. The results include estimates of uncertainty, and can predict reliability at some not-too-distant time in the future. This paper presents an overview of the underlying statistical model for the analysis, discusses model assumptions, and demonstrates usage of SRFYDO.

97 MATHEMATICS AND COMPUTING↗

Testing a new NIF neutron time-of-flight detector with a bibenzyl scintillator on OMEGA

A new neutron time-of-flight (nTOF) detector with a bibenzyl crystal as a scintillator has been designed and manufactured for the National Ignition Facility (NIF). This detector will replace a nTOF20-Spec detector with an oxygenated xylene scintillator currently operational on the NIF to improve the areal-density measurements. In addition to areal density, the bibenzyl detector will measure the D-D and D-T neutron yield and the ion temperature of indirect- and direct-drive-implosion experiments. The design of the bibenzyl detector and results of tests on the OMEGA Laser System are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tests and Calibration of the NIF Neutron Time of Flight Detectors

The National Ignition Facility (NIF) Neutron Time of Flight (NTOF) diagnostic will measure neutron yield and ion temperature in all NIF campaigns in DD, DT, and THD* implosions. The NIF NTOF diagnostic is designed to measure neutron yield from 109 to 2 x 1019. The NTOF consists of several detectors of varying sensitivity located on the NIF at about 5 m and 20 m from the target. Production, testing, and calibration of the NIF NTOF detectors have begun at the Laboratory for Laser Energetics (LLE). Operational tests of the NTOF detectors were performed on several facilities including the OMEGA laser at LLE and the Titan laser at Lawrence Livermore National Laboratory (LLNL). Neutron calibrations were carried out on the OMEGA laser. Results of the NTOF detectors tests and calibration will be presented. *(D = deuterium, T = tritium, H = hydrogen)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First flight performance of the Micro-X microcalorimeter X-ray sounding rocket

The flight of the Micro-X sounding rocket on July 22, 2018, marked the first operation of transition-edge sensors and their superconducting quantum interference device readouts in space. Here, the instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia A supernova remnant. Although a rocket pointing malfunction led to no time on-target, data from the flight were used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared with ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Thermal Simulator Testing: Thermal Analysis and Test Results

Work at the NASA Marshall Space Flight Center seeks to develop high fidelity, electrically heated thermal simulators that represent fuel elements in a nuclear reactor design to support non-nuclear testing applicable to the potential development of a space nuclear power or propulsion system. Comparison between the fuel pins and thermal simulators is made at the outer fuel clad surface, which corresponds to the outer sheath surface in the thermal simulator. The thermal simulators that are currently being tested correspond to a liquid metal cooled reactor design that could be applied for Lunar surface power. These simulators are designed to meet the geometric and power requirements of a proposed surface power reactor design, accommodate testing of various axial power profiles, and incorporate imbedded instrumentation. This paper reports the results of thermal simulator analysis and testing in a bare element configuration, which does not incorporate active heat removal, and testing in a water-cooled calorimeter designed to mimic the heat removal that would be experienced in a reactor core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

General-Purpose Heat Source Radioisotope Thermoelectric Generator Flight Unit 5 Refurbished (GPHS-RTG F5R) Electrically Heated Thermal Vacuum Testing

Idaho National Laboratory (INL) has been tasked with the evaluation and refurbishment of the General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. This paper describes the testing of F5R in the thermal vacuum chamber and evaluation of the data demonstrating the generator meets updated Cassini-Huygens requirements. The generator produced 260 We of power at the specified 4100 Wth heat source inventory. This power exceeded the power requirement for 250 We , confirming system integrity and demonstrating that the generator is capable of potential NASA missions.

30 - DIRECT ENERGY CONVERSION↗

AMS Thermal Cooling System (Final Report)

The Alpha Magnetic Spectrometer (AMS) is a U.S. Department of Energy-sponsored particle physics experiment on the International Space Station (ISS). AMS is exploring some of the most fundamental questions in physics such as understanding dark matter, antimatter, the origin of cosmic rays and their characteristics as well as searching for new physics phenomena in the universe. It has recorded more than 200 billion cosmic rays since its launch in May 2011. Over time, anomalies associated with the dedicated cooling system of the AMS Silicon Tracker system were observed, leading to the discovery of progressive deterioration in the functioning of the cooling system's four redundant pumps. The Tracker is crucial to the scientific mission of AMS, as it is the only subdetector that can distinguish matter from antimatter. This report details the successful program of work for the installation of the Upgraded Tracker Thermal Pump System (UTTPS) on AMS. This program included: identifying the root cause of deterioration in the original pumps; design, production, testing, and integration of the new UTTPS cooling system; launch of the UTTPS to ISS; installation of the UTTPS in AMS across a series of four complex extra-vehicular activities (EVAs); and establishment of a dedicated Flight Simulator Laboratory to test the performance of the UTTPS under various thermal conditions. This program was critical to the success of the AMS experiment, and its successful completion will enable AMS to continue taking data through 2030.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A design for a compact time-of-flight mass spectrometer

The design of a prototype, compact time-of-flight (TOF) mass spectrometer (MS) is described. The system primarily consists of an ion acceleration/focusing/steering assembly (AFSA), an 8 cm field-free region, a 4 cm, dual-stage reflectron and a miniature microchannel plate detector. Consequently, the resulting flight length of the system is 12 cm. The system has been designed with the capability to sample directly from atmosphere at ambient pressures. This is accomplished through the use of an electrodynamic ion funnel, housed in an intermediate-vacuum chamber that is coupled to the inlet of the TOF chamber. TOF spectra were obtained using noble gases (Ar, Kr and Xe) as test chemicals. These measured flight times were used to probe the performance of the instrument. A temporal resolution (tflight/Δt) of approximately 125, acquired using 129Xe+, has been measured for the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Timing Counters for PSEC: MOU for Testing at MTEST

This is a memorandum of understanding between the Fermi National Accelerator Laboratory (Fermilab) and University of Chicago, Argonne National Laboratory (ANL), Saclay/lRFU and the University of Hawaii experimenters who have committed to participate in beam tests to be carried out during the 2008 Meson Test Beam Facility program. The memorandum is intended solely for the purpose of providing a budget estimate and a work allocation for Fermilab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties; however, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to negotiate the appropriate amendments to this memorandum if adjustments are required. The experimenters require beam time at Fermilab during the 2008 Meson Test Beam Run to test time-of-flight particle detectors with the ultimate goal of achieving 1 psec timing resolution. Proposed applications are: diffractive Higgs production background reduction at the LHC; measuring the momentum of muons before and after a 6D cooling setup as proposed by the MANX experiment; particle identification at a Super-B factory, LHC detector upgrades, possible third generation Tevatron Collider flavor experiments, precision kaon measurements, and astro-particle experiments. In addition, the development and testing of the associated electronics and timing algorithms may be directly applicable to advances in medical imaging. Much more information can be found at the PSEC web site, at http://hep.uchicago.edu/psec/.

43 PARTICLE ACCELERATORS↗

ECR-GDM Thruster for Fusion Propulsion

The concept of the Gasdynamic Mirror (GDM) device for fusion propulsion was proposed by and Lee (1995) over a decade ago and several theoretical papers has supported the feasibility of the concept. A new ECR plasma source has been built to supply power to the GDM experimental thruster previously tested at the Marshall Space Flight Center (MSFC). The new plasma generator, powered by microwaves at 2.45 or 10 GHz. is currently being tested. This ECR plasma source operates in a number of distinct plasma modes, depending upon the strength and shape of the local magnetic field. Of particular interest is the compact plasma jet issuing form the plasma generator when operated in a mirror configuration. The measured velocity profile in the jet plume is bimodal, possibly as a result of the GDM effect in the ECR chamber of the thruster.