Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development and Testing of a High Level Axial Array Duct Sound Source for the NASA Flow Impedance Test Facility

In this report both a frequency domain method for creating high level harmonic excitation and a time domain inverse method for creating large pulses in a duct are developed. To create controllable, high level sound an axial array of six JBL-2485 compression drivers was used. The pressure downstream is considered as input voltages to the sources filtered by the natural dynamics of the sources and the duct. It is shown that this dynamic behavior can be compensated for by filtering the inputs such that both time delays and phase changes are taken into account. The methods developed maximize the sound output while (i) keeping within the power constraints of the sources and (ii) maintaining a suitable level of reproduction accuracy. Harmonic excitation pressure levels of over 155dB were created experimentally over a wide frequency range (1000-4000Hz). For pulse excitation there is a tradeoff between accuracy of reproduction and sound level achieved. However, the accurate reproduction of a pulse with a maximum pressure level over 6500Pa was achieved experimentally. It was also shown that the throat connecting the driver to the duct makes it difficult to inject sound just below the cut-on of each acoustic mode (pre cut-on loading effect).

Johnson, Marty E.↗

Friction Factor Characterization for High-Porosity Random Fiber Regenerators

NASA Glenn Research Center, the Department of Energy (DOE), and Stirling Technology Company (STC) of Kennewick, Washington are developing a Stirling convertor for a high-efficiency Stirling Radioisotope Power System to provide electric power for NASA Space Science Missions. STC is developing the 55-We Technology Demonstration Convertor (TDC) under contract to DOE. Steady-flow tests were completed to determine the friction factor for the high-porosity regenerators that are used in the TDC. STC fabricated a flow test fixture and three random fiber regenerator test samples, one each at approximately 80, 88, and 96 percent porosities. The flow tests were then completed by the NASA Glenn Flow Calibration Laboratory, and the data reduced to Reynolds number and friction factor. The results showed that the 80 and 88 percent porosity samples had similar characteristics while the 96 percent porosity sample had significantly higher friction factors for given Reynolds numbers compared to the samples with lower porosities. Comparisons were also made between the test data and existing correlations. STC used this data to derive a modified regenerator friction factor correlation for use in the Stirling design code GLIMPS for porosities greater than 88 percent. Using this new correlation, the final optimized regenerator design porosity was reduced from 96 to 90 percent.

Thieme, Lanny G.↗

Oscillating flow loss test results in Stirling engine heat exchangers

The results are presented for a test program designed to generate a database of oscillating flow loss information that is applicable to Stirling engine heat exchangers. The tests were performed on heater/cooler tubes of various lengths and entrance/exit configurations, on stacked and sintered screen regenerators of various wire diameters and on Brunswick and Metex random fiber regenerators. The test results were performed over a range of oscillating flow parameters consistent with Stirling engine heat exchanger experience. The tests were performed on the Sunpower oscillating flow loss rig which is based on a variable stroke and variable frequency linear drive motor. In general, the results are presented by comparing the measured oscillating flow losses to the calculated flow losses. The calculated losses are based on the cycle integration of steady flow friction factors and entrance/exit loss coefficients.

Koester, G.↗

Inlet Acoustic Data from a High Bypass Ratio Turbofan Rotor in an Internal Flow Component Test Facility

In February 2017, aerodynamic and acoustic testing was completed on a scale-model high bypass ratio turbofan rotor, R4, in an internal flow component test facility. The objective of testing was to determine the aerodynamic and acoustic impact of fan casing treatments designed to reduce noise. The baseline configuration consisted of the R4 rotor with a hardwall fan case. Data are presented for a baseline acoustic run with fan exit instrumentation removed to give a clean acoustic configuration.

Turbofan↗

Inlet Acoustic Data from a High Bypass Ratio Turbofan Rotor in an Internal Flow Component Test Facility: Supplemental Data Files

In February 2017, aerodynamic and acoustic testing was completed on a scale-model high bypass ratio turbofan rotor, R4, in an internal flow component test facility. The objective of testing was to determine the aerodynamic and acoustic impact of fan casing treatments designed to reduce noise. The baseline configuration consisted of the R4 rotor with a hardwall fan case. Data are presented for a baseline acoustic run with fan exit instrumentation removed to give a clean acoustic configuration.

Bozak, Richard F.↗

Hybrid laminar flow control tests in the Boeing Research Wind Tunnel

The hybrid laminar flow control (HLFC) concept has undergone wind tunnel testing at near full-scale Reynolds number on an infinite wing of 30-deg sweep on which boundary-layer suction was furnished over the first 20 percent of chord of the upper surface. Depending on the external pressure distribution, the HLFC extended the laminarity of the boundary layer as far back as 45 percent of chord; this corresponds to a transition Reynolds number of about 11 million. The maximum chordwise extent of laminar run was found to be insensitive to the suction level over a wide range.

Parikh, P. G.↗

Development and Testing of the Europa Mission's Venturi Flow Meter

NASA's Marshall Space Flight Center (MSFC), in collaboration with NASA's Goddard Space Flight Center (GSFC), Fox Valve Development Corp. and Oxford Lasers, is developing a set of venturi flow meters for use on the Europa Mission's propulsion subsystem. The requirement for the venturi flow meters' throat diameters is approximately 0.040". An early risk reduction activity conducted by MSFC revealed that a venturi flow meter produced by FOX with a throat diameter near 0.040" had much higher pressure loss than venturi flow meters with larger throat diameters and venturis of similar throat diameter size but with no pressure taps (i.e. venturis with a throat length to diameter ratio of zero). In response, a series of venturi flow meters was fabricated and flow tested to gain insight into pressure recovery as it is affected by pressure port diameter, throat length and diffuser angle in an effort to improve the performance of a venturi flow meter. This presentation provides a summary of the venturi flow meter development activity including: a description of the test's objectives, a detailed description of each venturi configuration, a description of the manufacturing processes of the venturis, and observations from the test data. A summary of the current development activities will also be given, as well as the current development path forward. Ultimately, the knowledge gained through the fabrication and testing of these venturis provides guidance to design a flight venturi flow meters with pressure recoveries that is acceptable for the Europa flight application.

Diaz, C. E.↗

Further results of natural laminar flow flight test experiments

Flight test experiments were conducted to measure the extent and nature of natural laminar flow on a smoothed test region of a swept-wing business jet wing. Surface hot film anemometry and sublimating chemicals were used for transition detection. Surface pressure distributions were measured using pressure belts. Engine noise was monitored by a microphone attached to the wing surface to study possible acoustic effects on stability of the laminar boundary layer. Side-slip conditions were flown to simulate changes in effective wing sweep. Flight instrumentation and ground data analysis techniques and a method for measuring intermittency of turbulence are described. Correlation was obtained between the hot film gage signals and chemicals for transition detection. Cross-flow vortices were observed for some flight conditions. Results of spectral and statistical analysis of the hot film signals for various flight test conditions are presented.

Wentz, W. H., Jr.↗

Flow Visualization Tests of a 0.004-scale Space Shuttle Vehicle 2A Model (no. 13-OTS) in the MSFC 14-inch Trisonic Wind Tunnel (IS6A)

Documented are representative photographs of surface flow patterns, created by oil flow and shadowgraph techniques, obtained during wind tunnel tests of an 0.004-scale version of the 2A SSV orbiter. The purpose of this test series was to obtain flow visualization photographs to aid in interpretation of test IS1 aero-noise data. The test was conducted at nominal Mach numbers from 0.6 to 3.48. The orbiter was run in proximity to the external tank and solid rocket boosters at angles of attack from -5 deg to +9 deg at 0 deg angle of sideslip.

Hawthorne, P. J.↗

Advanced Control Surface Seal Development for Future Space Vehicles

NASA's Glenn Research Center (GRC) has been developing advanced high temperature structural seals since the late 1980s and is currently developing seals for future space vehicles as part of the Next Generation Launch Technology (NGLT) program. This includes control surface seals that seal the edges and hinge lines of movable flaps and elevons on future reentry vehicles. In these applications, the seals must operate at temperatures above 2000 F in an oxidizing environment, limit hot gas leakage to protect underlying structures, endure high temperature scrubbing against rough surfaces, and remain flexible and resilient enough to stay in contact with sealing surfaces for multiple heating and loading cycles. For this study, three seal designs were compared against the baseline spring tube seal through a series of compression tests at room temperature and 2000 F and flow tests at room temperature. In addition, canted coil springs were tested as preloaders behind the seals at room temperature to assess their potential for improving resiliency. Addition of these preloader elements resulted in significant increases in resiliency compared to seals by themselves and surpassed the performance of the baseline seal at room temperature. Flow tests demonstrated that the seal candidates with engineered cores had lower leakage rates than the baseline spring tube design. However, then the seals were placed on the preloader elements, the flow rates were higher as the seals were not compressed as much and therefore were not able to fill the groove as well. High temperature tests were also conducted to assess the compatability of seal fabrics against cermaic matrix composite (CMC) panels anticipated for use in next generation launch vehicles. These evaluations demonstrated potential bonding issues between the Nextel fabrics and CMC candidates.

DeMange, Jeffrey J.↗

Advanced Control Surface Seal Development for Future Space Vehicles

NASA s Glenn Research Center (GRC) has been developing advanced high temperature structural seals since the late 1980's and is currently developing seals for future space vehicles as part of the Next Generation Launch Technology (NGLT) program. This includes control surface seals that seal the edges and hinge lines of movable flaps and elevons on future reentry vehicles. In these applications, the seals must operate at temperatures above 2000 F in an oxidizing environment, limit hot gas leakage to protect underlying structures, endure high temperature scrubbing against rough surfaces, and remain flexible and resilient enough to stay in contact with sealing surfaces for multiple heating and loading cycles. For this study, three seal designs were compared against the baseline spring tube seal through a series of compression tests at room temperature and 2000 F and flow tests at room temperature. In addition, canted coil springs were tested as preloaders behind the seals at room temperature to assess their potential for improving resiliency. Addition of these preloader elements resulted in significant increases in resiliency compared to the seals by themselves and surpassed the performance of the baseline seal at room temperature. Flow tests demonstrated that the seal candidates with engineered cores had lower leakage rates than the baseline spring tube design. However, when the seals were placed on the preloader elements, the flow rates were higher as the seals were not compressed as much and therefore were not able to fill the groove as well. High temperature tests were also conducted to asses the compatibility of seal fabrics against ceramic matrix composite (CMC) panels anticipated for use in next generation launch vehicles. These evaluations demonstrated potential bonding issues between the Nextel fabrics and CMC candidates.

DeMange, J. J.↗

CFD Simulations of the AEDC H3 Arc-Jet Flow: Mach 3.3 Nozzle, Flow Surveys, Wedge Models

This paper reports computational simulations and analysis of tests in a high enthalpy arc-jet facility at Arnold Engineering Development Center. These tests were conducted using wedge models placed in a free jet downstream of a 4.5-inch diameter contoured Mach 3.3 nozzle in the H3 facility. For calibration of test conditions, one wedge calibration plate instrumented with an array of pressure and coaxial thermocouple heat flux gages, one stagnation pressure probe and two null-point heat flux calorimeters were used. The pitot pressure and null-point probe measurements give experimental surveys of the test flow, providing assessment of the flow uniformity and valuable data for flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle, into the test box and over the wedge models, and comparisons with the experimental measurements. Several issues related to testing are considered: test flow characterization, prediction of surface quantities for three wedge models, effects of model shape change and test article recession, and prediction of surface quantities for the test articles with two circular cavities. These simulations take into account non-uniform total enthalpy profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the wedge model flowfields.

Arc-jet testing↗

Standardization of carbon-phenolic composite test methodology

The objective of this study was to evaluate the residual volatiles, filler content, and resin flow test procedures for carbon-phenolic prepreg materials. The residual volatile test procedure was rewritten with tighter procedure control which was then evaluated by round robin testing by four laboratories on the same rolls of prepreg. Results indicated that the residual volatiles test was too operator and equipment dependent to be reliable, and it was recommended that the test be discontinued. The resin flow test procedures were rewritten with tighter procedure control, and it is now considered to be an acceptable test. It was recommended that the filler content determination be made prior to prepregging.

Hall, W. B.↗