Search NASA⌕ Search

SEARCH · Search NASA

Results for “functional fault models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

136 records · Page 8

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Kinetic-controlled transformations of group-III arsenide nanocubes

Tracking the structural evolution of colloidal nanocrystals (NCs) facilitates the mechanistic studies of their materials chemistry. NC engineering via phase transformation reveals the chemical and physical determinants that drive lattice-scale dynamic processes such as cation exchange. Here, in this study, we employed NCs to demonstrate the cation exchange process from Cu 3 As to InAs and GaAs within nanocubes. The symmetry conversion in unit cells from cubic Cu 3 As to hexagonal InAs and GaAs can be described using a schematic cellular automaton model, which suggests a simplified cube-to-sphere transition. The strong covalent characteristics of III–V materials highlight the kinetic control that navigates the tailorable transformation through either an isotropic trajectory, leading to hollow structures, or a topotaxial trajectory, with abundant stacking faults. The reconstruction of complex covalent bonds is envisioned as the foundation for the synthesis of NCs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Advanced control sequences and FDD technology. Just shiny objects, or ready for scale?

Innovations in commercial building control sequences (ASHRAE guideline 36) and fault detection and diagnostics (FDD) technology have the potential to transform existing building operational efficiency by realizing whole-building level savings on the order of 15% and higher. However, several technical and market barriers related to up-front estimation of achievable savings, verifying implementation, and ensuring persistence are slowing down their adoption as a core offering through diverse owner-funded initiatives and rate-payer funded programs. This paper describes a suite of solutions to overcome these barriers to program delivery of advanced HVAC controls integrated with FDD energy management and information system (EMIS) technology. First, the Guideline 36 conformance test offers an automated method to confirm correct sequence implementation by the manufacturer, before field deployment. A successful test of a controller was conducted using a new manufacturer-independent hardware-in-the-loop testbed demonstrating the viability and scalability of this approach. Second, the Guideline 36 energy savings calculator uses modeling paired with high-level user inputs to estimate building-specific savings potential, target cost effective implementation and minimize uncertainty. Initial results indicate the baseline control sequences significantly impact energy savings, however, as much as 50% savings may be possible for the worst-case baseline scenario. Third, a functional specification provides minimum recommended EMIS-FDD capabilities, and best practices to integrate the technology into organizational practice and ensure that advanced control sequences provide persistent savings.

Pritoni, Marco↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cross-slip and easy-glide CRSS in titanium: Theoretical predictions and in-situ TEM measurements

This study investigates the mechanics of prismatic and first-order pyramidal $\langle$a$\rangle$ slip in titanium (Ti), elucidating the physics of easy-glide and cross-slip through a combination of theory and experiments. Screw-character prismatic (Pr) dislocations in Ti are of particular interest because their complex cores can be stable or unstable, leading to activation by either cross-slip or planar glide. To investigate these mechanisms, site-specific micro tensile samples were prepared using focused ion beam (FIB) milling and mounted on a push-to-pull (PTP) device for in-situ transmission electron microscopy (TEM) tensile testing. The in-situ experiments provide direct observations of the onset of dislocation motion and the precise determination of the critical resolved shear stress (CRSS) for the activated mechanisms, and its evolution with load cycling. A comprehensive theory has been developed to predict the CRSS values for easy glide, cross-slip, and multiplication of dislocations. Predicted critical stresses for pyramidal (π)-to-Pr and reverse cross-slip agree closely with the experimental measurements. The latter cross-slip stress is a factor of two higher than that of unobstructed planar slip. The model accounts for overlapping dislocation cores and employs a Wigner-Seitz based cell to evaluate misfit energies. By combining ab initio density functional theory (DFT) with anisotropic elasticity, the framework identifies minimum energy pathways for dislocation glide, which can be intermittent and zig-zag. A simplified expression utilizing (π) and Pr Schmid factor ratios is proposed for critical stress corresponding to (π)-to-Pr cross-slip transition. The results are strongly dependent on crystal orientation, underscoring non-Schmid behavior. Overall, this study explores key critical stress parameters essential for informing higher-scale simulations of plasticity in Ti.

Critical stress↗

Protection System Validation Using Post-Event Anomaly Classification with Machine Learning

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Asymmetric equilibrium core structures of pyramidal-II < c + a > dislocations in ten hexagonal-close-packed metals

The structures of pyramidal-II < c + a > dislocations, one of the most important defects in structural hexagonal-close-packed (HCP) metals, have not been fully characterized for many of the HCP metals in use today. Here, we employ ab initio informed phase-field dislocation dynamics to determine the minimum energy structure of pyramidal {1¯1¯22} < 11¯23 > dislocations in ten HCP metals, including Be, Co, Mg, Re, Ti, Zn, Cd, Hf, Y, and Zr. As input for the simulations, we calculate, using first-principles density functional theory, the {1¯1¯22} generalized stacking fault energy (GSFE) curves for all ten metals. From these calculations, it is found that magnetism in Co is necessary for achieving a local minimum in the GSFE curve. We observe in simulations that edge and screw character dislocations split into two partials separated by a low-energy intrinsic stacking fault. The splitting distance is shown to scale inversely with the local minimum energy normalized by the product of its shear modulus and Burgers vector. Interestingly, some HCP metals exhibit an asymmetric structure, with either unequal partial Burgers vectors or widths, in contrast to the symmetric configuration expected from linear elastic dislocation theory. We explain these structures by properties of the local maxima in their GSFE curves. Metals with larger degrees of elastic anisotropy result in dislocations with larger splitting distances than would be expected under the commonly used assumption of elastic isotropy. Furthermore, these findings on the sizes and asymmetry in the structures of pyramidal-II < c + a > dislocations are fundamental to understanding how these dislocations glide and interact or react with other defects when these metals are mechanically strained.

36 MATERIALS SCIENCE↗

Refining Processing Engines from SAPHIRE: Initialization of Fault Tree/Event Tree Solver

SAPHIRE has been extensively employed for over 35 years to model risk-important systems and quantify risk models. As a well-established and thoroughly documented Probabilistic Risk Assessment (PRA) tool, SAPHIRE has continuously tracked computational trends and received regular updates. Despite its ongoing evolution, there remains a need for further enhancements, particularly in dealing with the quantification of exceptionally large models. These improvements could take the form of algorithmic advancements, harnessing the power of parallel computing, and exploring the potential benefits of cloud computing solutions. Considering these aspirations, the notion of a remote solve option was introduced and subsequently evolved into a dedicated project within the SAPHIRE development team. A significant outcome of this initiative is SAPHSOLVE, an engine extracted from the SageRisk API designed specifically for remote solving capabilities. The ongoing project is nearing its culmination, marked by a series of discoveries that have brought undocumented aspects to light. Among these revelations is the intricacy of the input and output format for the SAPHSOLVE engine. This document serves the crucial purpose of meticulously delineating the precise formats for both input and output, as they form an indispensable foundation. The importance of documenting these formats cannot be overstated, as it is a pivotal step in facilitating rigorous testing and comparison. Whether it involves scrutinizing SAPHSOLVE results against those of the internal integrated solver or other external solvers, the ability to construct models or transform existing ones into a compatible SAPHSOLVE format is imperative. Chapter 1 offers a succinct introduction to both SAPHIRE and SAPHSOLVE, followed by Chapter 2 which outlines the roadmap for enhancing SAPHSOLVE. The core of this report is Chapter 3, which intricately elucidates the intricacies of the input and output file formats. To provide a tangible illustration of these formats, a rudimentary example has been compiled and is available in Appendix. SAPHSOLVE represents a novel external solving mechanism developed by the SAPHIRE team, although it has not yet reached the full spectrum of capabilities possessed by SAPHIRE's internal solver. However, the SAPHIRE team has set a comprehensive course for incorporating the functionalities of SAPHSOLVE. A comprehensive outlook on the future of SAPHSOLVE is expounded upon in Chapter 4.

97 MATHEMATICS AND COMPUTING↗

Jefferson Laboratory C100 Superconducting Radio-Frequency Cavity Fault Data, 2020

The dataset was created to train machine learning models for the task of identifying the (1) cavity and (2) fault type from C100-type cryomodules at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), thereby replacing the time-consuming efforts of a subject matter expert. Superconducting radio-frequency (SRF) cavity trips represent a significant source of accelerator downtime. Real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type would give control room operators valuable feedback for corrective action planning. The anticipated benefit is increased beam-on-target time for users and provides performance metrics that can be used to improve future cavity designs. A series of 17 RF signals are recorded for each of the 8 cavities in a C100 cryomodule every time a cavity trips. These time-series signals are written to file using a specially designed data acquisition system. The dataset represents fault events recorded during Continuous Electron Beam Accelerator Facility (CEBAF) beam operations between January 18, 2019 and March 9, 2020. The following filtering steps were applied to collected data; (1) only 4 of the 17 signals per cavity are retained (GMES, GASK, CRFP, DETA2) (2) only events with data from each of the eight cavities in the cryomodule are kept, (3) only events that were sampled at 5 kHz were kept, (4) events from cryomodule 0L04 were neglected, (5) events occurring between February 4, 3PM and February 5, 12PM were neglected. As a result of preprocessing, the dataset is comprised of 2,375 unique events. The full dataset is comprised of three files: features.csv, cavity_labels.csv, fault_labels.csv. Each instance in faults.csv includes a timestamp (“date_time”), a label for the cryomodule which experienced the trip (“zone_label”), and 192 features (“feature_1”, “feature_2”... “feature_192”). The features correspond to 6 autoregressive features for each of 4 signals per cavity for each of the 8 cavities (6 × 4 signals/cavity × 8 cavities/cryomodule = 192). To deal with the large variation of signal amplitudes, time-series standardization via the z-score (standard score) function was applied prior to computing the features. For each instance, there is an associated label for the (1) cavity which faulted first (cavity_labels.csv) and (2) the type of fault that caused the trip (fault_labels.csv). The cavity identification can take values of [0, 1, 2, 3, 4, 5, 6, 7, 8] and the fault type can take values of [‘Microphonics’, ‘Quench_100ms’, ‘Controls_Fault’, ‘E_Quench’, ‘Quench_3ms’, ‘Single_Cav_Turn_Off’ , ‘Heat_Riser_Choke’, ‘Multi_Cav_Turn_Off’].

43 PARTICLE ACCELERATORS↗

Specifying Calibration of Environmental Sensors

The emergence of the Internet of Things is resulting in an increased ability of devices and systems to share data and is generating increasing interest in integrating sensors into a variety of devices deployed in the built environment. The value of such data is a function of how the data can be used. Data-producing devices and systems that enable valuable use-cases in turn can be seen as more valuable. Lighting systems are particularly interesting platforms for integrated sensors. Both indoor and outdoor lighting devices are becoming more connected, and their location is often ideally suited for hosting environmental sensors that can characterize the properties of indoor or outdoor spaces in ways that support a wide variety of use cases, from improving air quality to supporting fault diagnostics and prediction. The value of environmental-sensor-driven use-cases and the lighting systems that house them is dependent to some degree on sensor accuracy. Environmental sensors utilize a wide variety of sensing techniques or technologies and have varying accuracy. More-accurate, laboratory-grade products or reference standards are often used to characterize, refine, calibrate, adjust, and monitor devices that are deployed, or are intended to be deployed, in physical spaces of interest. Sensors or reference standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user and use-case requirements. This paper provides guidance for evaluating the performance of environmental sensors so as to ensure that they meet user or use-case needs. It describes best practices that have been developed for a) calibrating sensors to ensure some known level of accuracy, and b) determining whether calibration-laboratory accreditation meets user or use-case needs. Excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently have sensors calibrated or who have new or changing needs for sensor calibration, rationale is provided for why a specification might be used to request calibration services that meet specific needs. Commercially available calibration-service providers that are accredited for environmental-sensor calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of environmental-sensor test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

42 ENGINEERING↗