Search NASA⌕ Search

SEARCH · Search NASA

Results for “fusion application”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Gamma-ray spectroscopy at MHz counting rates with a compact LaBr{sub 3} detector and silicon photomultipliers for fusion plasma applications

Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr{sub 3} scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The magnetic recoil spectrometer (MRSt) for time-resolved measurements of the neutron spectrum at the National Ignition Facility (NIF)

The next-generation magnetic recoil spectrometer for time-resolved measurements of the neutron spectrum has been conceptually designed for the National Ignition Facility. This spectrometer, called MRSt, represents a paradigm shift in our thinking about neutron spectrometry for inertial confinement fusion applications, as it will provide simultaneously information about the burn history and time evolution of areal density (ρR), apparent ion temperature (T{sub i}), yield (Y{sub n}), and macroscopic flows during burn. From this type of data, an assessment of the evolution of the fuel assembly, hotspot, and alpha heating can be made. According to simulations, the MRSt will provide accurate data with a time resolution of ∼20 ps and energy resolution of ∼100 keV for total neutron yields above ∼10{sup 16}. At lower yields, the diagnostic will be operated at a higher-efficiency, lower-energy-resolution mode to provide a time resolution of ∼20 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma Barodiffusion in Inertial-Confinement-Fusion Implosions: Application to Observed Yield Anomalies in Thermonuclear Fuel Mixtures

The observation of large, self-generated electric fields ({>=}10{sup 9} V/m) in imploding capsules using proton radiography has been reported [C. K. Li et al., Phys. Rev. Lett. 100, 225001 (2008)]. A model of pressure gradient-driven diffusion in a plasma with self-generated electric fields is developed and applied to reported neutron yield deficits for equimolar D{sup 3}He[J. R. Rygg et al., Phys. Plasmas 13, 052702 (2006)] and (DT){sup 3}He[H. W. Herrmann et al., Phys. Plasmas 16, 056312 (2009)] fuel mixtures and Ar-doped deuterium fuels [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The observed anomalies are explained as a mild loss of deuterium nuclei near capsule center arising from shock-driven diffusion in the high-field limit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion irradiation study of lithium silicates for fusion blanket applications

Here, this study reports on the microstructural and compositional evolutions, deuterium release and lithium loss behavior in lithium silicates. Pellets of biphasic Li 4 SiO 4 and Li 2 SiO 3 were fabricated using hot pressing of powders. Sequential irradiation with Si + , He + and D + ions was performed up to 773 K to emulate one-year 6 Li burnup in 6 Li 4 SiO 4 inside the SlimCS DEMO. Crystalline Li 4 SiO 4 phase was not observed in the irradiated depth region of all the samples in this study. In spite of full amorphization in the near-surface region, Li 2 SiO 3 irradiated to a high dose at 773 K remained crystalline in the damage peak region, suggesting that Li 2 SiO 3 is more irradiation resistant to amorphization than Li 4 SiO 4 . Radiolysis may be primarily responsible for silicate decomposition and amorphization. Data from this study also show that D release from the pellet is very efficient during ion irradiation at 773 K, which is accompanied with a significant Li loss. Thermal annealing for 10 min at 773 K for the room-temperature irradiated pellet leads to a nearly complete D release without an observable Li loss. A concept of Ni coating on tritium breeder materials is discussed with supporting data to minimize Li loss without a significant impact on tritium diffusion and release.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preface to the ISLA-7 Special Issue: Liquid Metals Applications for Fusion

Although most of the readers of this special issue of JoFE may already be familiar, briefly addressed in this work for completeness are some of the technical issues associated with the divertor which employs tungsten as the plasma-facing surface material brazed on a heat sink, perhaps made of copper alloys such as Glidcop, the thermal conductivity of which can be as high as ~365 W/mK.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multimodal super-resolution: discovering hidden physics and its application to fusion plasmas

Understanding complex physical systems often requires integrating data from multiple diagnostics, each with limited resolution or coverage. We present a machine learning framework that reconstructs synthetic high-temporal-resolution data for a target diagnostic using information from other diagnostics, without direct target measurements during the inference. This multimodal super-resolution technique improves diagnostic robustness and enables monitoring even in case of measurement failures or degradation. Applied to fusion plasmas, our method targets edge-localized modes (ELMs), which can damage plasma-facing materials. By reconstructing super-resolution Thomson Scattering data from complementary diagnostics, we uncover fine-scale plasma dynamics and validate the role of resonant magnetic perturbations (RMPs) in ELM suppression through magnetic island formation. The approach provides new observation supporting the plasma profile flattening due to these islands. Our results demonstrate the framework’s ability to generate high-fidelity synthetic diagnostics, offering a powerful tool for ELM control development in future reactors like ITER. The approach is broadly transferable to other domains facing sparse, incomplete, or degraded diagnostic data, opening new avenues for discovery.

Jalalvand, Azarakhsh [Princeton Univ., NJ (United ↗

Design of a digital multiradian phase detector and its application in fusion plasma interferometry

We discuss the circuit design of a digital multiradian phase detector that measures the phase difference between two 10 kHz square wave TTL signals and provides the result as a binary number. The phase resolution of the circuit is 1/64 period and its dynamic range is 256 periods. This circuit has been developed for fusion plasma interferometry with submillimeter waves on the ASDEX Upgrade tokamak. The results from interferometric density measurement are discussed and compared to those obtained with the previously used phase detectors, especially with respect to the occurrence of phase jumps. It is illustrated that the new phase measurement provides a powerful tool for automatic real-time validation of the measured density, which is important for feedback algorithms that are sensitive to spurious density signals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time evolution of negative ion profile in a large cesiated negative ion source applicable to fusion reactors

To understand the physics of the cesium (Cs) recycling in the large Cs-seeded negative ion sources relevant to ITER and JT-60SA with ion extraction area of 45-60 cm × 110-120 cm, the time evolution of the negative ion profile was precisely measured in JT-60SA where the ion extraction area is longitudinally segmented into 5. The Cs was seeded from the oven at 180 °C to the ion source. After 1 g of Cs input, surface production of the negative ions appeared only in the central segment where a Cs nozzle was located. Up to 2 g of Cs, the negative ion profile was longitudinally expanded over full ion extraction area. The measured time evolution of the negative ion profile has the similar tendency of distribution of the Cs atoms that is calculated. From the results, it is suggested that Cs atom distribution is correlated with the formation of the negative ion profile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiattribute probabilistic prostate elastic registration (MAPPER): Application to fusion of ultrasound and magnetic resonance imaging

Purpose: Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is better able to distinguish prostate cancer from benign tissue. However, MRI-guided biopsy requires special equipment and training and a longer procedure time. MRI-TRUS fusion, where MRI is acquired preoperatively and then aligned to TRUS, allows for advantages of both modalities to be leveraged during biopsy. MRI-TRUS-guided biopsy increases the yield of cancer positive biopsies. In this work, the authors present multiattribute probabilistic postate elastic registration (MAPPER) to align prostate MRI and TRUS imagery. Methods: MAPPER involves (1) segmenting the prostate on MRI, (2) calculating a multiattribute probabilistic map of prostate location on TRUS, and (3) maximizing overlap between the prostate segmentation on MRI and the multiattribute probabilistic map on TRUS, thereby driving registration of MRI onto TRUS. MAPPER represents a significant advancement over the current state-of-the-art as it requires no user interaction during the biopsy procedure by leveraging texture and spatial information to determine the prostate location on TRUS. Although MAPPER requires manual interaction to segment the prostate on MRI, this step is performed prior to biopsy and will not substantially increase biopsy procedure time. Results: MAPPER was evaluated on 13 patient studies from two independent datasets—Dataset 1 has 6 studies acquired with a side-firing TRUS probe and a 1.5 T pelvic phased-array coil MRI; Dataset 2 has 7 studies acquired with a volumetric end-firing TRUS probe and a 3.0 T endorectal coil MRI. MAPPER has a root-mean-square error (RMSE) for expert selected fiducials of 3.36 ± 1.10 mm for Dataset 1 and 3.14 ± 0.75 mm for Dataset 2. State-of-the-art MRI-TRUS fusion methods report RMSE of 3.06–2.07 mm. Conclusions: MAPPER aligns MRI and TRUS imagery without manual intervention ensuring efficient, reproducible registration. MAPPER has a similar RMSE to state-of-the-art methods that require manual intervention.

60 APPLIED LIFE SCIENCES↗

Novel Low-Cost Method of Manufacturing Nb 3 Sn Multifilamentary Superconductors with Multiple-Tin-Sources

In this project, we have successfully demonstrated a potentially economical Nb 3 Sn conductor manufacturing process for future fusion devices. This has been accomplished by replacing subelements having a tin core with subelements having a tin coating. In this Phase II program, we have successfully fabricated strand utilizing a novel conductor design approach and demonstrated a 50 meter cable that may be utilized for future fusion applications. Conductor critical current evaluation was performed of this strand and suggest that this approach may be a technically competitive approach for high field magnet applications such as future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗