Search NASA⌕ Search

SEARCH · Search NASA

Results for “gamma correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

MODELING THE HARD TeV SPECTRA OF BLAZARS 1ES 0229+200 AND 3C 66A WITH AN INTERNAL ABSORPTION SCENARIO

We study the applicability of the idea of internal absorption of {gamma}-rays produced through synchrotron radiation of ultrarelativistic protons in highly magnetized blobs to 1ES 0229+200 and 3C 66A, the two TeV blazars which show unusually hard intrinsic {gamma}-ray spectra after being corrected for the intergalactic absorption. We show that for certain combinations of reasonable model parameters, even with quite modest energy requirements, the scenario allows a self-consistent explanation of the non-thermal emission of these objects in the keV, GeV, and TeV energy bands.

79 ASTRONOMY AND ASTROPHYSICS↗

Validity of the Wannier threshold law for angular correlation width in double photoionization of atoms

We calculated using the ab initio method the three-fold differential cross section of a single-photon double photoionization of helium at equal energy sharing and derived the Gaussian width parameter {gamma}, describing the angular interelectron correlations, for the total electron energy E ranging from 0.1 to 100 eV. The results are in perfect agreement with experimental data. Contrary to common expectations, the results demonstrate that the Wannier threshold law for the Gaussian width parameter {gamma}{proportional_to}E{sup 1/4} is not correct at energies attainable in modern experiments. It is shown that the {gamma} dependence on the energy is much better described by the modified threshold law, obtained by Kazansky and Ostrovsky [J. Phys. B 26, 2231 (1993)]. Also, we explored the Gaussian width parameter for double photoionization of targets with strongly asymmetrical initial-state configuration: the atomic hydrogen negative ion H{sup -} and the helium atom in the 2s {sup 1}S and 3s {sup 1}S excited states. We found that the Gaussian width dependence on the total ejected electron energy for these targets has a maximum at low energies. We also show that the correlation parameter dependence on the interelectron angle for these targets is essentially non-Gaussian and has a number of peaks equal to the number of the initial-state radial nodes, which provide new facilities for the qualitative analysis of the electron structure of the target atom.

74 ATOMIC AND MOLECULAR PHYSICS↗

GAMMA-RAY BURSTS ARE OBSERVED OFF-AXIS

We constrain the jet opening angle and, for the first time, the off-axis observer angle for gamma-ray bursts in the Swift-XRT catalog by using the ScaleFit package to fit afterglow light curves directly to hydrodynamic simulations. The ScaleFit model uses scaling relations in the hydrodynamic and radiation equations to compute synthetic light curves directly from a set of high-resolution two-dimensional relativistic blast wave simulations. The data sample consists of all Swift-XRT afterglows from 2005 to 2012 with sufficient coverage and a known redshift, 226 bursts in total. We find that the jet half-opening angle varies widely but is commonly less than 0.1 rad. The distribution of the electron spectral index is also broad, with a median at 2.30. We find the observer angle to have a median value of 0.57 of the jet opening angle over our sample, which has profound consequences for the predicted rate of observed jet breaks and affects the beaming-corrected total energies of gamma-ray bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

Higgs phenomenology in warped extra dimensions with a fourth generation

We study a warped extra-dimension scenario where the standard model fields lie in the bulk, with the addition of a fourth family of fermions. We concentrate on the flavor structure of the Higgs couplings with fermions in the flavor anarchy ansatz. Even without a fourth family, these couplings will be generically misaligned with respect to the standard model fermion mass matrices. The presence of the fourth family typically enhances the misalignment effects and we show that one should expect them to be highly nonsymmetrical in the (34) intergenerational mixing. The radiative corrections from the new fermions and their flavor-violating couplings to the Higgs affect negligibly known experimental precision measurements such as the oblique parameters and Z{yields}bb or Z{yields}{mu}{sup +}{mu}{sup -}. On the other hand, {Delta}F=1, 2 processes, mediated by tree-level Higgs exchange, as well as radiative corrections to b{yields}s{gamma} and {mu}{yields}e{gamma} put some generic pressure on the allowed size of the flavor-violating couplings. But more importantly, these couplings will alter the Higgs decay patterns as well as those of the new fermions, and produce very interesting new signals associated to Higgs phenomenology in high energy colliders. These signals might become very important indirect signals for these type of models as they would be present even when the KK mass scale is high and no heavy KK particle is discovered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Discovery of a transient MeV range gamma-ray source

The University of California, San Diego (UCSD)/MIT hard X-ray and gamma-ray instrument on the HEAO 1 surveyed the region near the Galactic center 3 times during its lifetime in 1977-1979. During the 1977 September-October scan, a gamma-ray source was detected south of the Galactic center. The source was below the threshold sensitivity in the spring and fall of 1978. The source was detected with the medium energy phoswich scintillation counters which operated over the 80 keV-2 MeV range, had an area of 42 sq cm each, and a 17 deg FWHM aperture. The error box for the source is centered on l = 2.4 deg, b = -12.2 deg, with a 90% confidence error circle of approximately 3.5 deg radius. The flux in the 333-635 keV range was (1.89 +/- 0.29) x 10(exp -5) photons/(sq cm s keV) and was constant within statistics during the 1 month period the source was in the field of view. The spectrum can be characterized as a Gaussian in the range 300 less than or = E less than or = 650 keV, with a FWHM of 249 +/- 51 keV centered on 461 +/- 22 keV. The flux of this broad Gaussian is (6.6 +/- 1.1) x 10(exp -3) photons/(sq cm s). The source is tentatively identified with the 5.57 hr period low-mass X-ray-emitting binary system 1H 1822-371. Assuming this is correct, the ratio of gamma-ray to X-ray luminosity during the outburst was about 5; at a distance of 8 kpc, the gamma ray luminosity is 4 x 10(exp 37) ergs. The emission may be interpreted as a positron-pair plasma ejected from a compact object, possibly a black hole, and annihilating in a thick accretion disk surrounding the object.

Briggs, M. S.↗

ILLUMINATING THE DARKEST GAMMA-RAY BURSTS WITH RADIO OBSERVATIONS

We present X-ray, optical, near-infrared (IR), and radio observations of gamma-ray bursts (GRBs) 110709B and 111215A, as well as optical and near-IR observations of their host galaxies. The combination of X-ray detections and deep optical/near-IR limits establish both bursts as ''dark''. Sub-arcsecond positions enabled by radio detections lead to robust host galaxy associations, with optical detections that indicate z {approx}< 4 (110709B) and z Almost-Equal-To 1.8-2.9 (111215A). We therefore conclude that both bursts are dark due to substantial rest-frame extinction. Using the radio and X-ray data for each burst we find that GRB 110709B requires A{sub V}{sup host}{approx}>5.3 mag and GRB 111215A requires A{sub V}{sup host}{approx}>8.5 mag (assuming z = 2). These are among the largest extinction values inferred for dark bursts to date. The two bursts also exhibit large neutral hydrogen column densities of N{sub H,{sub int}} {approx}> 10{sup 22} cm{sup -2} (z = 2) as inferred from their X-ray spectra, in agreement with the trend for dark GRBs. Moreover, the inferred values are in agreement with the Galactic A{sub V} -N{sub H} relation, unlike the bulk of the GRB population. Finally, we find that for both bursts the afterglow emission is best explained by a collimated outflow with a total beaming-corrected energy of E{sub {gamma}} + E{sub K} Almost-Equal-To (7-9) Multiplication-Sign 10{sup 51} erg (z = 2) expanding into a wind medium with a high density, M Almost-Equal-To (6-20) Multiplication-Sign 10{sup -5} M{sub Sun} yr{sup -1} (n Almost-Equal-To 100-350 cm{sup -3} at Almost-Equal-To 10{sup 17} cm). While the energy release is typical of long GRBs, the inferred density may be indicative of larger mass-loss rates for GRB progenitors in dusty (and hence metal rich) environments. This study establishes the critical role of radio observations in demonstrating the origin and properties of dark GRBs. Observations with the JVLA and ALMA will provide a sample with sub-arcsecond positions and robust host associations that will help to shed light on obscured star formation and the role of metallicity in GRB progenitors.

79 ASTRONOMY AND ASTROPHYSICS↗

Finite-Q^2 Corrections to Parity-Violating DIS

Parity-violating deep inelastic scattering (PVDIS) has been proposed as an important new tool to extract the flavor and isospin dependence of parton distributions in the nucleon. We discuss finite-$Q^2$ effects in PVDIS asymmetries arising from subleading kinematical corrections and longitudinal contributions to the $\gamma Z$ interference. For the proton, these need to be accounted for when extracting the $d/u$ ratio at large $x$. For the deuteron, the finite-$Q^2$ corrections can distort the effects of charge symmetry violation in parton distributions, or signals for physics beyond the standard model. We further explore the dependence of PVDIS asymmetries for polarized targets on the $u$ and $d$ helicity distributions at large $x$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analytic model of the γ -surface deviation and influence on the stacking fault width between partial dislocations

The stacking fault width (R$_{eq}$) between partial dislocations within an FCC crystalline lattice characterizes the onset of numerous plastic flow mechanisms, as well as the relationship between material strength and grain size. Continuum models traditionally consider a complete unit of dislocation slip ( b ) along the $\langle{110}$$\rangle$ direction distributed between two discrete partial dislocations, each with a fixed partial Burgers vector ( b p ), which bound a stacking fault. Across the stacking fault, the vectorial slip is assumed to be constant, yielding a constant intrinsic stacking fault energy density, $\gamma$$_{isf}$ Here, we demonstrate that the vectorial displacement path taken in accomplishing a complete unit of slip (b) deviates from the expected displacement path containing the local minima, $\gamma$$_{isf}$ leading to a correction in the nominally derived stacking fault width. The magnitude of the correction depends on both the net orientation of the dislocation within the lattice, and also the degree of relaxation of each partial Burgers vector along the $\langle{\bar{1}12}$$\rangle$ direction. We derive a simple analytic model for the corrected stacking fault width, explicitly accounting for the deviation, by introducing a variable ξ (0 < ξ < 1), which governs the magnitude of each partial dislocation component along the $\langle{\bar{1}12}$$\rangle$ direction. Significantly, our model predicts a correction to R$_{eq}$ of ~$\mathscr{O}$ (|b|) for the nominally screw dislocation, and has no noticeable influence on nominally edge dislocations. We apply our model towards computing the stacking fault width of several FCC metals, and demonstrate excellent agreement both with our own numerical data as well as that obtained from ab initio and Molecular Statics (MS) methods within the literature. Lastly, the results from this study demonstrate that, upon judicious application, discrete linear elastic models are successful in reproducing elastic interactions as computed from higher fidelity models on the spatial scale of metallic dislocation cores.

36 MATERIALS SCIENCE↗

Updated constraints on primordial black hole evaporation

The Hawking evaporation process, leading to the production of detectable particle species, constrains the abundance of light black holes, presumably of primordial origin. Here, we reconsider and correct constraints from soft gamma-ray observations, including of the gamma-ray line, at 511 keV, produced by electron-positron pair-annihilation, where positrons originate from black hole evaporation. First, we point out that the INTEGRAL detection of the Large Magellanic Cloud provides one of the strongest bounds attainable with present observations; and that future MeV gamma-ray telescopes, such as GECCO, will greatly enhance such constraints. Second, we discuss issues with previous limits from the isotropic flux at 511 keV and we provide updated, robust constraints from recent measurements of the diffuse Galactic soft gamma-ray emission and from the isotropic soft gamma-ray background.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-600: Patient Specific IMRT Verification Using a Phosphor-Screen Based Geometric QA System: A Preliminary Study

Purpose: Raven QA (JPLC, MD) is a unified and comprehensive quality assurance system for QA of TG-142, which use a phosphor screen, a mirror system and a camera. It is to test if this device can be used for IMRT QA dosimetry. Methods: A lung IMRT case is used deliver dose to Raven QA. Accuracy of dose distribution of 5cm slab phantom using Eclipse planning system (Varian) has been confirmed both from a Monte Carlo Simulation and from a MapCheck (SunNuclear) measurement. Geometric distortion and variation of spatial dose response are corrected after background subtraction. A pin-hole grid plate is designed and used to determine the light scatter in the Raven QA box and the spatial dose response. Optic scatter model was not applied in this preliminary study. Dose is normalized to the response of the 10×10 field and the TMR of 5cm depth was considered. Results: Time to setup the device for IMRT QA takes less than 5 minutes as other commercially available devices. It shows excellent dose linearity and dose rate independent, less than 1 %. Background signal, however, changes for different field sizes. It is believed to be due to inaccurate correction of optic scatter. Absolute gamma (5%, 5mm) passing rate was higher than 95%. Conclusion: This study proves that the Raven QA can be used for a patient specific IMRT verification. Part of this study is supported by the Maryland Industrial Partnership Grant.

61 RADIATION PROTECTION AND DOSIMETRY↗

Collection, analysis, and archival of LDEF activation data

Samples intentionally placed aboard the LDEF and samples obtained from the LDEF structure were studied at NASA Marshall and seven national labs to determine the radioactivity produced in orbit. The gamma ray spectra from these studies have provided information concerning the type and quantity of radioactive nuclei produced by various activating particles. The gamma ray spectra, the resulting activation, and the experimental arrangements are being collected at Marshall and Eastern Kentucky Univ. for review, further analysis, and future archival. An overview of this process and the type of information that will be available for future reference is given. This information includes the samples studied, the location of the samples on LDEF, the amount and type of covering material, the types of detector systems, the format of the gamma ray spectra, and the corrections for geometry, self-absorption, detector efficiency, and background needed to obtain accurate specific activations (activation per kilogram) of material. Plans are given as to the archival of the data for such future reference and how other scientific investigators or spacecraft designers can access the data.

Laird, C. E.↗

Ten Year Ozone Profile Record From Suomi NPP OMPS Limb Profiler

In this study, we evaluate a decadal ozone profile record derived from Suomi NPP Ozone Mapping and Profiler Suite (OMPS) Limb Profiler (LP). The data from OMPS LP were re-processed with the new retrieval algorithm from 2012 to present. The new reprocessing includes adjustments in both Level 1 and Level 2 algorithms. The sensor’s altitude registration, updates in radiometric calibrations, under-sampling and stray light corrections were addressed in Level 1 processing. The new retrieval algorithm (version 2.7) combines measurements from UV and VIS parts of the spectra to retrieve a single vertical ozone profile between 12.5 km (or cloud tops) and 57.5 km, unlike to previous version 2.5 where ozone profiles were retrieved independently from UV and VIS. To improve ozone retrievals in the Upper Troposphere Lower Stratosphere (UTLS) region, we implemented a new aerosol correction that assumes a gamma-function particle size distribution. In addition, ozone and nitrogen dioxide cross sections and climatologies were updated. We discuss sensitivity of the ozone retrievals to implemented changes in Level 1 and Level 2 algorithms. We focus our analysis on evaluation of the stability of the 10-year record from OMPS LP. We show results from the internal methods for characterizing the stability of the LP altitude registration and compare the LP reflectivity and ozone with the similar quantities measured by OMPS nadir sensors. Finally, we will show results from comparisons with independent satellite (MLS and SAGE III) and ozone sonde measurements.

Ozone↗

The impact of low-Z and high-Z metal implants in IMRT: A Monte Carlo study of dose inaccuracies in commercial dose algorithms

Purpose: The aim of the study was to evaluate the dosimetric impact of low-Z and high-Z metallic implants on IMRT plans. Methods: Computed tomography (CT) scans of three patients were analyzed to study effects due to the presence of Titanium (low-Z), Platinum and Gold (high-Z) inserts. To eliminate artifacts in CT images, a sinogram-based metal artifact reduction algorithm was applied. IMRT dose calculations were performed on both the uncorrected and corrected images using a commercial planning system (convolution/superposition algorithm) and an in-house Monte Carlo platform. Dose differences between uncorrected and corrected datasets were computed and analyzed using gamma index (Pγ{sub <1}) and setting 2 mm and 2% as distance to agreement and dose difference criteria, respectively. Beam specific depth dose profiles across the metal were also examined. Results: Dose discrepancies between corrected and uncorrected datasets were not significant for low-Z material. High-Z materials caused under-dosage of 20%–25% in the region surrounding the metal and over dosage of 10%–15% downstream of the hardware. Gamma index test yielded Pγ{sub <1}>99% for all low-Z cases; while for high-Z cases it returned 91% < Pγ{sub <1}< 99%. Analysis of the depth dose curve of a single beam for low-Z cases revealed that, although the dose attenuation is altered inside the metal, it does not differ downstream of the insert. However, for high-Z metal implants the dose is increased up to 10%–12% around the insert. In addition, Monte Carlo method was more sensitive to the presence of metal inserts than superposition/convolution algorithm. Conclusions: The reduction in terms of dose of metal artifacts in CT images is relevant for high-Z implants. In this case, dose distribution should be calculated using Monte Carlo algorithms, given their superior accuracy in dose modeling in and around the metal. In addition, the knowledge of the composition of metal inserts improves the accuracy of the Monte Carlo dose calculation significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging

Purpose: Electronic portal imaging devices (EPIDs) have been studied and used for pretreatment and in-vivo dosimetry applications for many years. The application of EPIDs for dosimetry in arc treatments requires accurate characterization of the mechanical sag of the EPID and gantry during rotation. Several studies have investigated the effects of gravity on the sag of these systems but each have limitations. In this study, an easy experiment setup and accurate algorithm have been introduced to characterize and correct for the effect of EPID and gantry sag during arc delivery. Methods: Three metallic ball bearings were used as markers in the beam: two of them fixed to the gantry head and the third positioned at the isocenter. EPID images were acquired during a 360 deg. gantry rotation in cine imaging mode. The markers were tracked in EPID images and a robust in-house developed MATLAB code was used to analyse the images and find the EPID sag in three directions as well as the EPID + gantry sag by comparison to the reference gantry zero image. The algorithm results were then tested against independent methods. The method was applied to compare the effect in clockwise and counter clockwise gantry rotations and different source-to-detector distances (SDDs). The results were monitored for one linear accelerator over a course of 15 months and six other linear-accelerators from two treatment centers were also investigated using this method. The generalized shift patterns were derived from the data and used in an image registration algorithm to correct for the effect of the mechanical sag in the system. The Gamma evaluation (3%, 3 mm) technique was used to investigate the improvement in alignment of cine EPID images of a fixed field, by comparing both individual images and the sum of images in a series with the reference gantry zero image. Results: The mechanical sag during gantry rotation was dependent on the gantry angle and was larger in the in-plane direction, although the patterns were not identical for various linear-accelerators. The reproducibility of measurements was within 0.2 mm over a period of 15 months. The direction of gantry rotation and SDD did not affect the results by more than 0.3 mm. Results of independent tests agreed with the algorithm within the accuracy of the measurement tools. When comparing summed images, the percentage of points with Gamma index <1 increased from 85.4% to 94.1% after correcting for the EPID sag, and to 99.3% after correction for gantry + EPID sag. Conclusions: The measurement method and algorithms introduced in this study use cine-images, are highly accurate, simple, fast, and reproducible. It tests all gantry angles and provides a suitable automatic analysis and correction tool to improve EPID dosimetry and perform comprehensive linac QA for arc treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Large mass expansion in two-loop QCD corrections of paracharmonium decay

We calculate the two-loop QCD corrections to paracharmonium decays {eta}{sub c}{yields}{gamma}{gamma} and {eta}{sub c}{yields}gg involving light-by-light scattering diagrams with light quark loops. Artificial large mass expansion and convergence improvement techniques are used to evaluate these corrections. The obtained corrections to the decays {eta}{sub c}{yields}{gamma}{gamma} and {eta}{sub c}{yields}gg account for -1.25% and -0.73% of the leading order contribution, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements

Purpose: Four-dimensional computed tomography (4DCT) can be used to make measurements of pulmonary function longitudinally. The sensitivity of such measurements to identify change depends on measurement uncertainty. Previously, intrasubject reproducibility of Jacobian-based measures of lung tissue expansion was studied in two repeat prior-RT 4DCT human acquisitions. Difference in respiratory effort such as breathing amplitude and frequency may affect longitudinal function assessment. In this study, the authors present normalization schemes that correct ventilation images for variations in respiratory effort and assess the reproducibility improvement after effort correction.Methods: Repeat 4DCT image data acquired within a short time interval from 24 patients prior to radiation therapy (RT) were used for this analysis. Using a tissue volume preserving deformable image registration algorithm, Jacobian ventilation maps in two scanning sessions were computed and compared on the same coordinate for reproducibility analysis. In addition to computing the ventilation maps from end expiration to end inspiration, the authors investigated the effort normalization strategies using other intermediated inspiration phases upon the principles of equivalent tidal volume (ETV) and equivalent lung volume (ELV). Scatter plots and mean square error of the repeat ventilation maps and the Jacobian ratio map were generated for four conditions: no effort correction, global normalization, ETV, and ELV. In addition, gamma pass rate was calculated from a modified gamma index evaluation between two ventilation maps, using acceptance criterions of 2 mm distance-to-agreement and 5% ventilation difference.Results: The pattern of regional pulmonary ventilation changes as lung volume changes. All effort correction strategies improved reproducibility when changes in respiratory effort were greater than 150 cc (p < 0.005 with regard to the gamma pass rate). Improvement of reproducibility was correlated with respiratory effort difference (R = 0.744 for ELV in the cohort with tidal volume difference greater than 100 cc). In general for all subjects, global normalization, ETV and ELV significantly improved reproducibility compared to no effort correction (p = 0.009, 0.002, 0.005 respectively). When tidal volume difference was small (less than 100 cc), none of the three effort correction strategies improved reproducibility significantly (p = 0.52, 0.46, 0.46 respectively). For the cohort (N = 13) with tidal volume difference greater than 100 cc, the average gamma pass rate improves from 57.3% before correction to 66.3% after global normalization, and 76.3% after ELV. ELV was found to be significantly better than global normalization (p = 0.04 for all subjects, and p = 0.003 for the cohort with tidal volume difference greater than 100 cc).Conclusions: All effort correction strategies improve the reproducibility of the authors' pulmonary ventilation measures, and the improvement of reproducibility is highly correlated with the changes in respiratory effort. ELV gives better results as effort difference increase, followed by ETV, then global. However, based on the spatial and temporal heterogeneity in the lung expansion rate, a single scaling factor (e.g., global normalization) appears to be less accurate to correct the ventilation map when changes in respiratory effort are large.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗