Improving fission-product decay data for reactor applications: part I—decay heat

Effort has been expended to assess the relative merits of undertaking further decay-data measurements of the main fission-product contributors to the decay heat of neutron-irradiated fissionable fuel and related actinides by means of Total Absorption Gamma-ray Spectroscopy (TAGS - sometimes abbreviated to TAS) and Discrete Gamma-ray Spectroscopy (DGS). This review has been carried out following similar work performed under the auspices of OECD/WPEC-Subgroup 25 (2005–2007) and the International Atomic Energy Agency (2009, 2014), and various highly relevant TAGS measurements completed as a consequence of such assessments. Here, we present our recommendations for new decay-data evaluations, along with possible requirements for total absorption and discrete high-resolution gamma-ray spectroscopy studies that cover approximately 120 fission products and various isomeric states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectroscopic Analysis of Pu-bearing Compounds in Double-Walled Cells

Spectroscopic analysis of radiological materials has been historically limited to radiological labs with 11 older or less advanced scientific instrumentation. The development of double-walled cells (DWCs) at 12 the Savannah River National Laboratory (SRNL) has enabled Pu-bearing compounds to be removed 13 from radiological laboratories and studied in our radiologically clean spectroscopy lab with state-of14 the-art instrumentation. In this manuscript, we discuss the contributions of DWCs that have allowed 15 the application of Raman spectroscopy, diffuse reflectance infrared Fourier transform spectroscopy 16 (DRIFTS), diffuse reflectance spectroscopy (DRS) in the shortwave infrared, and gamma 17 spectroscopy at SRNL. Significant advances have been made in the understanding of thermal 18 decomposition of Pu(III) and Pu(IV) oxalates, the alpha-induced damage to the PuO2 crystal lattice, 19 and the effect of calcination temperatures to the quality of PuO2. These techniques have enabled 20 methods to conduct PuO2 age dating since last calcination and estimate the calcination temperature 21 with Raman and DRS. Additional spectroscopic information measured with DRIFTS has provided a 22 path to observe the evolution of carbon species with calcination temperature while gamma 23 spectroscopy provides information on age dating since last purification.

Villa-Aleman, Eliel↗

X-ray escape peaks in gamma-ray spectrum acquired by perovskite detector

The X-ray escape peaks are clearly visible in the high-resolution gamma spectra acquired by CsPbBr 3 , credit to the rapidly improving energy resolution of perovskite gamma detectors. But it also raises concerns. If this peak remains as significant as it is, perovskite gamma detectors would have very limited use in complex gamma spectrometry applications. This paper discusses the origin of the escape peaks in CsPbBr 3 detectors, benchmarked against Ge and CZT detectors. The Pb escape peak consists of four escape peaks that are merged together, while the Cs and Br escape peaks are hidden inside the photopeak of 137 Cs (662 keV). These combined effects either create a noticeable gamma peak observed to the left of the 662 keV photopeak when acquired using a high-resolution CsPbBr 3 detector or raise the left slope of the photopeak. We also explore potential methods to mitigate these peaks, such as applying anti-coincidence method. The height of the escape peaks diminishes as the detector volume increases but will not go away entirely. The relationship between the observed Pb escape peak and the detector's dimensions is demonstrated through Monte Carlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission Product Quantification and Burnup Analysis via Gamma Spectrometry of the AGR-5/6/7 TRISO Fuel Experiment

Five capsules containing varying configurations of TRISO fuel compacts were irradiated in the most recent Advanced Gas Reactor (AGR) TRISO test campaign, AGR-5/6/7. As part of the post-irradiation examination (PIE) of this work all the fuel compacts and capsule graphite holders were measured with the Precision Gamma Scanner (PGS) to determine isotopic activities and locations using gamma spectrometry. Measuring the compacts allowed for the comparison of physics model depletion calculations with the measured compact activity to validate models. These measurements also are used to find compacts of interest with low fission product retention that may be tested in subsequent PIE. Measurements of the holders can confirm fission product distribution and migration. Of the isotopes measured, Cs-137 and Cs-134 were used to estimate location of failed particles as well as determine a measured burnup estimation. Results from Capsule 1 compacts and the holder indicate many fuel particle failures occurred. There are high amounts of cesium in the holder near Stack 9 of Capsule 1 that corresponds to low fractions?measured-to-calculated (M/C) ratio?of cesium remaining in those compacts. All other capsules had cesium retention ratios near 1. The isotope 110mAg had less consistent results. Capsule 2 compacts exhibited a M/C of 0.20, much lower than anticipated for the temperatures these compacts underwent. Capsule 3 experienced much higher temperatures, >1300C and had an average M/C of 0.75. These are the opposite results than what was predicted by past AGR experiments for the relationship between temperature and isotope retention. Capsule 4 and 5 showed good fission product retention and agreement with the physics model predictions. The burnup results from the PGS measurements showed strong agreement between the physics models and the measured values. Using a ratio of Cs-134/Cs-137 to calculate the burnup match closely with the physics models. Additionally, the Cs-137 burnup results were less accurate but extremely close to the model results.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultra-low-level measurements of airborne fission products from the Fukushima Daiichi reactor accident using high volume collection systems at Savannah River National Laboratory

For this study, ultra-low-level measurements of radionuclides in air have been conducted at the Savannah River National Laboratory (SRNL) to determine the atmospheric concentration of fission products released following the Fukushima Daiichi reactor accident on March 11, 2011. Air filter samples were acquired from two high-volume collection systems (a traditional filter-based system and an electrostatic precipitator-based system) to monitor airborne radionuclide concentrations in the period covering from 2 weeks to 3 years after the disaster. The world-wide spread of low-level concentrations of airborne fission products from the Fukushima event provided a unique opportunity to demonstrate SRNL's electrostatic particle collection technology and other improvements in environmental monitoring developed at the Savannah River Site (SRS). Detecting and analyzing the release allowed a comprehensive test of SRS systems for monitoring environmental radioactivity. Gamma-ray-emitting fission products ( 131,132 I, 134,136,137 Cs, and 129,132 Te) and cosmogenic isotopes ( 7 Be and 22 Na) in air were detected and quantified by high-resolution gamma-ray spectroscopy at concentrations as low as 0.07 μBq per standard cubic meter (SCM) (50 mBq total 137 Cs), while plutonium content was quantified by thermal ionization mass spectrometry (TIMS) at concentrations as low as 6.5 × 10 –21 g/SCM (3.0 fg 239+240 Pu). Isotope concentrations measured at SRNL from gamma-ray spectroscopy were compared to independent measurements from Chapel Hill, NC, located approximately 370 km (230 mi) NE of SRNL. Meteorological modeling was also used to predict radionuclide transport from the location of release to both measurement locations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Characterization of the degradation of gamma-irradiated elastomers using Raman spectroscopy

This report presents key findings from Raman spectroscopic analysis of gamma-irradiated rubber samples extracted from a laminated lead-damped rubber (LDR) seismic isolation device. The samples were exposed to gamma radiation from a 60Co source in a Foss Therapy Services gamma irradiator, reaching absorbed doses up to 1600 kGy. A distinct threshold near 400 kGy was identified, beyond which significant spectral changes were observed. Two Raman peaks - at approximately 425 cm-1 and 2440 cm-1 - were tracked as a function of dose using Gaussian fitting. The 425 cm-1 peak, attributed to sulfur–sulfur (S–S) bond stretching (resulting from vulcanization of the rubber), exhibited a dose-dependent upshift, indicating radiation-induced crosslinking within the sulfur-based polymer network. Conversely, the 2440 cm-1 peak, likely associated with vibrational modes of additives or impurities, showed a downward shift with increasing dose, suggesting chain scission and degradation of non-rubber constituents. These results provide first-of-a-kind insights into the microstructural evolution of elastomers under high-dose gamma irradiation and establish a preliminary dose threshold for significant degradation. Future work will incorporate multi-modal characterization—including Fourier Transform Infrared (FTIR) spectroscopy, scanning electrom microscopy (SEM) of the rubber surface morphology, thermogravimetric analysis (TGA) to determine changes in thermal stability, and mechanical testing—to correlate molecular-level changes with macroscopic performance of these elastomers as damping media in seismic isolation devices. These findings are expected to provide regulatory guidance and design criteria for qualifying low-damping rubber seismic isolators in advanced nuclear reactor applications.

36 - MATERIALS SCIENCE↗

In-beam γ-ray spectroscopy of 37–42 P

The level schemes of the neutron-rich 37-42 P isotopes are investigated via in-beam gamma-ray spectroscopy following the fragmentation of a 45 Cl projectile beam at intermediate beam energies. Information on gamma-gamma coincidence relationships complemented by comparisons to shell-model calculations in the sd-pf model space were used to construct excitation level schemes for these neutron-rich nuclei. For the odd-mass 37,39 P isotopes, a level scheme is presented that appears essentially complete at low energies and exhausts the states predicted by the SDPF-MU shell-model Hamiltonian. In conclusion, simple Nilsson configurations are proposed for the low-lying excited states of 38,39,40,41 P from an analysis of the E2 transition matrix elements and moments calculated within the shell model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel methodology for gamma-ray spectra dataset procurement over varying standoff distances and source activities

The adoption of machine learning approaches for gamma-ray spectroscopy has received considerable attention in the literature. Many studies have investigated the deployment of various algorithm architectures to a specific task. However, little attention has been afforded to the development of the datasets leveraged to train the models. Such training datasets typically span a set of environmental or detector parameters to encompass a problem space of interest to a user. Variations in these measurement parameters will also induce fluctuations in the detector response, including expected pile-up and ground scatter effects. Fundamental to this work is the understanding that 1) the underlying spectral shape varies as the measurement parameters change and 2) the statistical uncertainties associated with two spectra impact their level of similarity. While previous studies attribute some arbitrary discretization to the measurement parameters for the generation of their synthetic training data, this work introduces a principled methodology for efficient spectral-based discretization of a problem space. A signal-to-noise ratio (SNR) respective spectral comparison measure and a Gaussian Process Regression (GPR) model are used to predict the spectral similarity across a range of measurement parameters. This innovative approach effectively showcased its capability by dividing a problem space, ranging from 5 cm to 100 cm standoff distances and 5 μCi–100 μCi of 137 Cs, into three unique combinations of measurement parameters. The findings from this work will aid in creating more robust datasets, which incorporate many possible measurement scenarios, reduce the number of required experimental test set measurements, and possibly enable experimental training data collection for gamma-ray spectroscopy.

data science↗

Optimization of an Energy Tuning Assembly for High Explosives Detection

The Portable Isotopic Neutron Spectroscopy (PINS) system, employs neutron-induced gamma-ray spectroscopy and provides a nondestructive method for high explosives detection. In standard operation it uses Californium-252 as a neutron source. Operating PINS with a deuterium-tritium (DT) neutron generator has some advantages over Cf-252, including lifetime and ability to produce high-energy inelastic scattering gamma rays. However, current systems using DT neutron generators suffer from a high environmental background and reduced ability to induce neutron capture, reducing spectral quality and limiting nitrogen sensitivity. Here, this study presents the development of an energy-tuning assembly (ETA) designed to optimize the DT neutron energy spectrum to increase nitrogen reaction rates in a target, thereby improving high explosive detection capabilities. A metaheuristic optimization framework, MultiGNOWEE, coupled with MCNP, was employed to generate two ETA configurations: a single-objective ETA, which maximizes nitrogen capture reactions, and a multi-objective ETA, which balances neutron capture and inelastic scattering. Simulations demonstrated the optimized configurations achieved up to a 10-fold improvement in nitrogen capture rates compared to the bare configuration. Experimental validation was conducted using a DT neutron generator and a high-purity germanium (HPGe) detector. Two prototype ETAs were constructed and assessed on a melamine simulant. Measurements demonstrated improved nitrogen detection for both prototype ETA configurations when compared to the standard system.

97 MATHEMATICS AND COMPUTING↗

HERMES-400 Microcalorimetry Measurements of Nuclear Fuel at Idaho National Laboratory

Microcalorimetry updates from HERMES-400 located at Idaho National Laboratory will be presented. In particular, the current outlook as well as future upgrades will be discussed. Data will be presented for Byron and TRISO particle fuel measurements highlighting improved energy resolution compared to traditional gamma-ray spectroscopy.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploring Gamma-Ray and Neutron Spectroscopy Missions to Mars Caves [Slides]

In this work, we investigate the sensitivity of active neutron detector systems in Mars caves using MCNP6 to model neutron transport in different cave geometries, compositions, and detectors to determine if active neutron measurements can be used to identify the hydration of cave walls vs floor vs ceilings, and to perform a concept study for potential future Mars cave missions in search of hydration and habitable regions.

79 ASTRONOMY AND ASTROPHYSICS↗

A cryogenic white light absorption spectroscopy setup with in situ gamma irradiation and thermo-optical annealing for optical fiber radiation-induced attenuation characterization

Silica optical fiber sensors offer a fast, distributed measurement solution in various cryogenic and radiation environments, such as magnets for fusion power. Under these conditions, light-absorbing point defects limit lifetime via radiation-induced attenuation (RIA). To support RIA kinetics prediction, we present an in situ, broadband absorption spectroscopy setup combining gamma irradiation with liquid nitrogen cooling. The apparatus enables continuous monitoring of narrowband RIA levels and the use of secondary optical annealing light sources, alongside broadband spectrum measurements to characterize RIA defects through spectrum decomposition. Initial results confirm the inevitable photobleaching effect of the probe light source, which must be accounted for. In addition, we report RIA kinetics during cycles of gamma irradiation at 77 K and isochronal thermal annealing steps from liquid nitrogen to room temperature, showcasing the setup’s ability to replicate real fiber operation scenarios. These instruments form an ideal platform to further study the kinetics of RIA coupled with thermal and optical annealing.

Absorption spectroscopy↗

Development and performance evaluation of a novel γ-γ coincidence analysis software

Processing of large amounts of data from a γ-γ coincidence system is a practical challenge in trace-level radionuclide measurements. Given the benefits and growing number of multidimensional gamma spectrometers worldwide, this is a major restriction in wide-spread applicability of coincidence techniques. This study demonstrates a novel γ-γ coincidence analysis software developed at Pacific Northwest National Laboratory, USA. The software utilizes advanced search techniques and Python libraries to readily identify coincidence signatures in the large data. Further, using both synthetic and experimental data, the study uncovers various strategies/libraries employed during software’s development. This work aims to provide a reference document in handling large data routinely encountered in trace-level measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

A technique using small, enriched uranium-aluminum alloy monitors to measure fission rates in fuel plate assembly reactors was developed at the Idaho National Laboratory Radiation Measurements Laboratory in support of Advanced Test Reactor Critical (ATR-C) Facility irradiations. Previous measurements were performed to determine the correlation between the beta-particle activity and the fission rate in the U-Al monitors following irradiation. The American Society for Testing and Materials (ASTM) has established a standard practice E704 for determining neutron fluence rate by radioactivation of depleted uranium by measuring the concentration of fission-products in irradiated uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of using a method adapted from the ASTM standard practice E704 was investigated for ATR-C irradiations and compared to the present method by analyzing a subset of 21 monitor wires using both methods. The resulting calculated fission rates agreed with an average standard deviation of 7.45%, within the average combined measurement error of 9.05%. Practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the sources of error for each method were investigated. Quality assurance measurements utilizing the modified ASTM standard method are recommended for future test irradiation, but gross-beta-particle counting remains the most practical solution for ATR-C fluence-rate determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗