Search NASA⌕ Search

SEARCH · Search NASA

Results for “gating grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

134 records · Page 8

Life cycle greenhouse gas emissions of hydrogen fuel production from chlor-alkali processes in the United States

By-product hydrogen from chlor-alkali processes can help meet the increasing demand for hydrogen fuel in early fuel cell electric vehicle markets (e.g., California) in the U.S. Hydrogen produced from chlor-alkali plants is typically combusted for process heat on site, vented to the atmosphere (i.e., wasted), or sold to the external merchant hydrogen market. Whether it is combusted, vented, or sold as a commodity, relevant information is lacking as to the life-cycle environmental benefits or trade-offs of using by-product hydrogen from chlor-alkali plants. A life-cycle analysis framework was employed to evaluate well-to-gate greenhouse gas (GHG) emissions associated with by-product hydrogen from chlor-alkali processes in comparison with hydrogen from the conventional centralized natural gas steam methane reforming (central SMR) pathway. U.S.-specific, plant-by-plant, and up-to-date chlor-alkali production characteristics were incorporated into the analysis. In addition to the venting and combustion scenarios, to deal with the multi-functionality of the chlor-alkali processes that simultaneously produce chlorine, sodium hydroxide, and hydrogen, two different co-product allocation strategies were adopted mass allocation and market value allocation. It was estimated that by-product hydrogen production from chlor-alkali processes creates 1.3-9.8 kg CO 2 e/kg H 2 of life-cycle GHG emissions on average, which is 20-90% less than the conventional central SMR pathway. The results vary with co-product treatment scenarios, regional electric grid characteristics, on-site power generation, product prices, and hydrogen yield. Despite the variations in the results, it was concluded that the life-cycle GHG emission reduction benefits of using by-product hydrogen from chlor-alkali processes are robust. In conclusion, with a diverse set of scenario analyses, the study developed a comprehensive and detailed life-cycle GHG emissions inventory of the chlor-alkali by-product hydrogen pathway and quantified sensitivity indices in the context of different assumptions and input parameter values.

08 HYDROGEN↗

Advanced Power Electronics and Electric Machines

The advanced power electronics and electric machines (APEEM) research group at the National Renewable Energy Laboratory (NREL) has developed world-class experimental and modeling capabilities for designing and evaluating efficient and reliable power electronics and electric machines thermal management systems. They also design, fabricate and characterize advanced power electronics packaging, and are developing state-of-health monitoring techniques. These researchers deliver safe, reliable, high performing, power-dense components that allow seamless integration between renewable energy sources, electric transportation, and the grid, helping to make widespread electric vehicle (EV) adoption and greenhouse gas emissions reduction more feasible. This document outlines the group's major capabilities in the areas of power electronics; module development and characterization; thermal modeling and management; thermomechanical reliability analysis of devices, modules, inverters/converters, and electric machines; physics-of-failure-based reliability analysis; and microelectronics. It also overviews the group's state-of-the-art equipment for fluid-based thermal management; thermal measurement & characterization; thermomechanical reliability analysis; micro- and power electronics measurement & characterization; and prototype fabrication, as well as the group's world-class modeling and simulation capabilities.

advanced gate drivers↗

Controller-Hardware-in-the-Loop Test Bed for Fast-Switching SiC-Based 50-kW PV Inverter

The recent advent of wideband gap power semiconductor devices will lay the path to the future power converters. These devices provide the advantage of high switching speed and lower losses. The high cost and high switching speeds of these devices provide a challenge in the development and validation of the fast switching inverter controls with accuracy of that of a hardware setup. In this paper an FPGA real-time simulator-based controller-hardware-in-the-loop (CHIL) testbed is used to verify the low-level and advanced inverter controls fast switching wide bandgap-based string photovoltaic inverter. The paper also includes development of the CHIL testbed, which is run at a time-step of 500 ns in order to implement 20 kHz switching frequency. The developed CHIL testbed is validated through experimental results from a three-phase, 50 kW, 480 VLLrms SiC devices based inverter.

14 SOLAR ENERGY↗

Aeroflex Technology as Class-Y Demonstrator

Modern space field programmable gate array (FPGA) devices with increased functional density and operational frequency, such as Xilinx Virtex 4 (V4) and S (V5), are packaged in non-hermetic ceramic flip chip forms. These next generation space parts were not qualified to the MIL-PRF-38535 Qualified Manufacturer Listing (QML) class-V when they were released because class-V was only intended for hermetic parts. In order to bring Xilinx V5 type packages into the QML system, it was suggested that class-Y be set up as a new category. From 2010 through 2014, a JEDEC G12 task group developed screening and qualification requirements for Class-Y products. The Document Standardization Division of the Defense Logistics Agency (DLA) has completed an engineering practice study. In parallel with the class-Y efforts, the NASA Electronic Parts and Packaging (NEPP) program has funded JPL to study potential reliability issues of the class-Y products. The major hurdle of this task was the absence of adequate research samples. Figure 1-1 shows schematic diagrams of typical structures of class-Y type products. Typically, class-Y products are either in ceramic flip chip column grid array (CGA) or land grid array (LGA) form. In class-Y packages, underfill and heat spread adhesive materials are directly exposed to the spacecraft environment due to their non-hermeticity. One of the concerns originally raised was that the underfill material could degrade due to the spacecraft environment and negatively impact the reliability of the package. In order to study such issues, it was necessary to use ceramic daisy chain flip chip package samples so that continuity of flip chip solder bumps could be monitored during the reliability tests. However, none of the commercially available class-Y daisy chain parts had electrical connections through flip chip solder bumps; only solder columns were daisy chained, which made it impossible to test continuity of flip chip solder bumps without using extremely costly functional parts. Among space parts manufacturers who were interested in producing class-Y products, Aeroflex Microelectronic Solutions-HiRel had been developing assembly processes using their internal R&D classy type samples. In early 2012, JPL and Aeroflex initiated a collaboration to study reliability of the Aeroflex technology as a class-Y demonstrator.

Suh, Jong-ook↗

Miniature Ion-Mobility Spectrometer

The figure depicts a proposed miniature ion-mobility spectrometer that would be fabricated by micromachining. Unlike prior ion-mobility spectrometers, the proposed instrument would not be based on a time-of-flight principle and, consequently, would not have some of the disadvantageous characteristics of prior time-of-flight ion-mobility spectrometers. For example, one of these characteristics is the need for a bulky carrier-gas-feeding subsystem that includes a shutter gate to provide short pulses of gas in order to generate short pulses of ions. For another example, there is need for a complex device to generate pulses of ions from the pulses of gas and the device is capable of ionizing only a fraction of the incoming gas molecules; these characteristics preclude miniaturization. In contrast, the proposed instrument would not require a carrier-gas-feeding subsystem and would include a simple, highly compact device that would ionize all the molecules passing through it. The ionization device in the proposed instrument would be a 0.1-micron-thick dielectric membrane with metal electrodes on both sides. Small conical holes would be micromachined through the membrane and electrodes. An electric potential of the order of a volt applied between the membrane electrodes would give rise to an electric field of the order of several megavolts per meter in the submicron gap between the electrodes. An electric field of this magnitude would be sufficient to ionize all the molecules that enter the holes. Ionization (but not avalanche arcing) would occur because the distance between the ionizing electrodes would be less than the mean free path of gas molecules at the operating pressure of instrument. An accelerating grid would be located inside the instrument, downstream from the ionizing membrane. The electric potential applied to this grid would be negative relative to the potential on the inside electrode of the ionizing membrane and would be of a magnitude sufficient to generate a moderate electric field. Positive ions leaving the membrane holes would be accelerated in this electric field. The resulting flux of ions away from the ionization membrane would create a partial vacuum that would draw more of the gas medium through the membrane. The figure depicts a filter electrode and detector electrodes located along the sides of a drift tube downstream from the accelerator electrode. These electrodes would apply a transverse AC electric field superimposed on a ramped DC electric field. The AC field would effect differential transverse dispersal of ions. At a given instant of time, the trajectories of most of the ions would be bent toward the electrodes, causing most of the ions to collide with the electrodes and thereby become neutralized. The DC field would partly counteract the dispersive effect of the AC field, straightening the trajectories of a selected species of ions; the selection would vary with the magnitude of the applied DC field. The straightening of the trajectories of the selected ions would enable them to pass into the region between the detector electrodes. Depending on the polarity of the voltage applied to the detector electrodes, the electric field between the detector electrodes would draw the selected ions to one of these electrodes. Hence, the current collected by one of the detector electrodes would be a measure of the abundance of ions of the selected species. The ramping of the filter- electrode DC voltage would sweep the selection of ions through the spectrum of ionic species.

Hartley, Frank T.↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters

Smart inverters (SIs) have demonstrated their potential to provide grid services for both transmission and distribution systems. One of these grid services, distribution network voltage regulation by SIs, has the potential to improve network voltage regulation through controlling the reactive and active power output of the SIs. Voltage regulation by SIs will be distributed and might be better suited to controlling local conditions to complement traditional voltage-regulating assets, e.g., tap-changing transformers, capacitor banks, and line voltage regulators. There is a gap in the literature on comparing the SI response characteristics when the SIs are controlled by a local controller or external control signals. This paper presents an experimental study to characterize SI reactive power regulation responses to two different control methods: autonomous control and remote dispatch. We found that SI reactive power regulation responses exhibit important differences between these methods in terms of delays and ramp rate. Finally, power-hardware-in-the-loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL test results show that the SI response characteristics for autonomous control and remote dispatch need to be considered when planning for distribution network voltage regulation using SIs.

autonomous control↗

Research, Development and Demonstration of Peak Load Reduction on Distribution Feeders Using Distributed Energy Resources for the City of Fort Collins

This project titled “Research, Development and Demonstration of Peak Load Reduction on Distribution Feeders Using Distributed Energy Resources for the City of Fort Collins” evolved in response to the Department of Energy’s (DOE) Funding Opportunity Announcement (FOA) Number DE-PS26-07NT43119. Also referred to as the Fort Collins Renewable and Distributed System Integration (RDSI) Project, the effort was undertaken by a diverse group of local government, higher education and business organizations; and was driven by three overarching goals: I. Fulfill the requirements of the DOE FOA’s Area of Interest 2: Renewable and Distributed System Integration; most notably, to demonstrate the ability to reduce electric system distribution feeder peak load by 15% or more through the coordinated use of Distributed Energy Resources (DER). II. Advance the expertise, technologies and infrastructure necessary to support the long term vision of the Fort Collins Zero Energy District (FortZED) and move towards creating a zero energy district in the Fort Collins “Old Town” area. III. Further the goals of the City of Fort Collins Energy Policy, including the development of a Smart Grid-enabled distribution system in Fort Collins, expanded use of renewable energy, increased energy conservation, and peak load reduction. Through the collaborative efforts of the partner organizations, the Fort Collins RDSI project was successful in achieving all three of these goals. This report is organized into two distinct sections corresponding to the two phases of the project: • Part 1: Feeder Peak Load Reduction and the FortZED Initiative. • Part 2: Forming and Operating Utility Microgrids and Managing Load and Production Variability The original project scope addressed the Part 1 feeder peak load reduction. That work took place from 2009 through 2011 and was largely complete when the project scope was amended to include a demonstration of microgrid operations. While leveraging the assets, partner relationships, and lessons learned from Part 1, Part 2 was managed and executed as a distinct and substantially independent sub-project during the spring and summer of 2013. Both Parts 1 and 2 of the overall RDSI project can be viewed as cohesive stand-alone bodies of work and are presented as such within this report. In addition to the narratives, this document includes two Appendices that were compiled to supplement information about the various aspects of activities performed during Parts 1 and 2 of the project. Moreover, these Appendices are organized (as outlined below) so as to directly relate to the narratives in Part 1 and 2 of this report. • Appendix - Part 1: describes the roles of each project participant in regards to the feeder peak load reduction effort, and • Appendix - Part 2: deals with the microgrid research/demonstration.

14 SOLAR ENERGY↗

Development of the United States GReenhouse Gas and Air Pollutants Emissions System (GRA 2 PES)

In the U.S., emissions of greenhouse gases and air pollutants are often developed independently. Here, we describe the GReenhouse gas And Air Pollutants Emissions System (GRA 2 PES), which provides gridded emissions of fossil-fuel carbon dioxide (ffCO 2 ) and 93 air quality (AQ) species for 17 combustion and non-combustion sectors at 4 km × 4 km spatial resolution across the contiguous US. We find that the AQ emissions most spatially correlated with ffCO 2 are nitrogen oxides (NO x , ρ = 0.67), followed by sulfur dioxide (SO 2 , ρ = 0.51), carbon monoxide (CO, ρ = 0.44), and fine particulate matter (PM 2.5 , ρ = 0.38). We evaluate GRA 2 PES ffCO 2 emissions with an ensemble of publicly available regional and global inventories at national (Normalized Mean Bias (NMB) = +1.4%), state (NMB = +1.5%, R 2 = 0.98), and urban (NMB = +11.5%, R 2 = 0.97) scales. Nationally, the differences of publicly available inventories from the ensemble average range from −10.0% to +5.7%, and consistency diverges at state and urban scales. We simulate GRA 2 PES ffCO 2 in a particle dispersion model and compare to measurements of radiocarbon ( 14 C)-derived ffCO 2 collected in Los Angeles (August 2021), with results suggesting that GRA 2 PES ffCO 2 may be low by 19% for this city, but well within model-observation differences for other publicly available inventories (−43% to +94%). GRA 2 PES AQ/ffCO 2 ratios converted to concentration space generally agree with field observations (NMB = +4%, log R 2 = 0.90). Lastly, we present a method by which to utilize GRA 2 PES to derive AQ emission fluxes from ffCO 2 emissions.

Lyu, Congmeng [National Oceanic and Atmospheric Ad↗