Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat exchanger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Air Circulation and Heat Exchange Under Reduced Pressures

Heat exchange rates decrease non-linearly with reductions in atmospheric pressure. This decrease creates risk of thermal stress (elevated leaf temperatures) for plants under reduced pressures. Forced convection (fans) significantly increases heat exchange rate under almost all pressures except below ~ 10 kPa. Plant cultivation techniques under reduced pressures will require forced convection. The cooling curve technique is a reliable means of assessing the influence of environmental variables like pressure and gravity on gas exchange of plant. These results represent the extremes of gas exchange conditions for simple systems under variable pressures. In reality, dense plant canopies will exhibit responses in between these extremes. More research is needed to understand the dependence of forced convection on atmospheric pressure. The overall thermal balance model should include latent and radiative exchange components.

Rygalov, V.↗

Sensitivity analysis of design parameters in RowWise borehole layout for ground heat exchangers

Ground source heat pump systems offer a promising pathway toward energy-efficient building heating and cooling. The performance and cost-effectiveness of these systems heavily depend on the design of the ground heat exchanger (GHE), particularly the spatial placement of boreholes used in large commercial buildings. Among various borefield layout strategies, the RowWise approach generates and optimizes borehole configurations within irregular polygonal land boundaries, providing land-use efficiency and installation flexibility. While multiple geometric design parameters constrain the RowWise layout, their influence on the system thermal performance and total drilling requirements remains unclear. Thus, this study presents a sensitivity analysis of key design parameters influencing the RowWise layout of vertical borehole GHEs, including the perimeter spacing ratio, borehole spacing, borehole field rotation angle, and borehole length. GHEDesigner and Ray Tune are employed to generate and assess different RowWise configurations. A series of parametric simulations was conducted to quantify the impact of each parameter on geometric distribution, economic cost, and computational speed. The results provide critical insights into the sensitivity and relative importance of different design parameters of RowWise method, offering practical guidance for designers aiming to optimize GHE layouts by balancing thermal efficiency, land constraints, and economic feasibility.

Xu, Dikai [Purdue University]↗

Visualization of Two-phase Flow Maldistribution in Brazed Plate Heat Exchangers

Brazed plate heat exchangers (BPHEs) are widely used in refrigeration and HVAC applications, but are susceptible to two-phase flow maldistribution especially when operated as evaporators. Existing visualization approaches are either limited to idealized conditions or suffer from poor optical transparency. This paper presents a novel visualization method in which one edge of a BPHE, parallel to the refrigerant inlet or outlet port, is removed by wire electrical discharge machining and replaced with a flat, transparent plate. The planar geometry allows the use of optically and infrared (IR)-transparent materials, enabling both high-speed videography and IR thermography of the two-phase flow at the channel entrances and exits. Preliminary tests with R134a and R1234ze(Z) at saturation temperatures between 5 °C and 15 °C demonstrate that distinct two-phase flow patterns in the inlet header can be clearly identified and differentiated under realistic operating conditions. Potentials of optical flow analysis of high-speed videos are shown to provide objective, quantitative indicators for flow regime characterization and comparison. IR imaging of the outlet port reveals non-uniform temperature distributions at the channel exits, providing independent evidence of maldistribution across the channel stack. Limitations of IR temperature accuracy due to the spectral properties of the sapphire window are discussed, and directions for improvement are identified.

Hausherr, Carsten [Technical University of Berlin ↗

Direct contact droplet heat exchangers for thermal management in space

A liquid droplet heat exchanger for space applications is described which transfers heat between a gas and a liquid metal dispersed into droplets. The ability of the droplet heat exchanger to transfer heat between two media in direct contact over a wide temperature range circumvents many of the material limitations of conventional tube-type heat exchangers and does away with complicated plumbing systems and their tendency toward single point failure. Droplet heat exchangers offer large surface to volume ratios in a compact geometry, very low gas pressure drop, and high effectiveness. The application of the droplet heat exchanger in a high temperature Brayton cycle is discussed to illustrate its performance and operational characteristics.

Bruckner, A. P.↗

IMPACT OF SOIL TEMPERATURE VARIATION ON PERFORMANCE MODELING OF A NOVEL SHALLOW BORE GROUND HEAT EXCHANGER

A novel shallow bore (< 6 m deep) ground heat exchanger is proposed to substitute the conventional vertical bore ground heat exchanger (> 60 m deep) for ground source heat pump systems. A series of simulations were carried out to evaluate the impacts of the vertical soil temperature profile on the performance of the shallow bore ground heat exchanger in response to thermal loads of a ground source heat pump system, with various lengths of the shallow bore ground heat exchanger and ground thermal properties. The results indicate that the vertical soil temperature profile has a noticeable influence on the thermal response of the shallow bore ground heat exchanger. Moreover, for shallow bore ground heat exchangers with the same volume and buried depth, the one with greater length and narrower diameter has lower tank water temperature fluctuations over the year due to relatively more stable soil temperature, and the larger surface to volume ratio.

Shi, Liang↗

High Temperature Composite Heat Exchangers

High temperature composite heat exchangers are an enabling technology for a number of aeropropulsion applications. They offer the potential for mass reductions of greater than fifty percent over traditional metallics designs and enable vehicle and engine designs. Since they offer the ability to operate at significantly higher operating temperatures, they facilitate operation at reduced coolant flows and make possible temporary uncooled operation in temperature regimes, such as experienced during vehicle reentry, where traditional heat exchangers require coolant flow. This reduction in coolant requirements can translate into enhanced range or system payload. A brief review of the approaches and challengers to exploiting this important technology are presented, along with a status of recent government-funded projects.

Eckel, Andrew J.↗

Metal hydride heat exchanger and method of use

A heat exchanger incorporates a metal hydride heat exchanger and mitigates the fluid mixing process, and thus greatly improves the heat transfer efficiency and heat recovery processes. The metal hydride heat exchanger has a container for the metal hydride that has a large aspect ratio. A plurality of high aspect container for the metal hydride may be coupled with a manifold.

Bahar, Bamdad↗

System for fast draining of an airfan heat exchanger and methods of using the same

A system for draining an airfan heat exchanger includes an airfan heat exchanger including a housing, a pressurized gas source fluidly coupled to the airfan heat exchanger and configured to hold a purging gas at a predetermined pressure, and a controller configured to control delivery of the purging gas to the airfan heat exchanger. The pressurized gas source is configured to provide a flow of the purging gas to the airfan heat exchanger and thereby drain water held in the airfan heat exchanger. The purging gas to the airfan will cause the airfan to drain quickly avoiding potential damage to the airfan from freezing of the water during cold weather.

Jahnke, Fred C.↗

Evaluating Microchannel Heat Exchanger Lifetime for Concentrating Solar Power Applications FY24Q4 (RPPR-1)

Microchannel heat exchanger technology is being pursued for next generation CSP concepts for primary power cycle heat addition and power cycle heat recuperation due to the high heat transfer coefficients and pressure containment advantages of small sCO 2 channels. The economics of future CSP plants as dictated by the SETO 2020 or 2030 targets depend on a heat exchanger with a 30-year lifetime (resisting creep, fatigue, corrosion, erosion) and operational characteristics such as fast ramping and the ability to withstand thermal shock. However, the lifetime and operational limits of microchannel heat exchangers operating at high-temperatures, particularly those constructed from high-nickel alloys, are not well known. This uncertainty has resulted in heat exchanger vendors not being able to accurately forecast heat exchanger lifetime as required by customers, specify operational limits as required by process engineers to prevent premature heat exchanger failure, or overdesign heat exchanger which leads to higher cost than necessary. Our goal is to evaluate heat exchanger lifetime and operational limits for the manufacturing and prototype design for next-generation CSP heat exchanger technology through a combination of collecting experimental data and modeling studies.

14 SOLAR ENERGY↗

Counterflow Regolith Heat Exchanger

A problem exists in reducing the total heating power required to extract oxygen from lunar regolith. All such processes require heating a great deal of soil, and the heat energy is wasted if it cannot be recycled from processed material back into new material. The counterflow regolith heat exchanger (CoRHE) is a device that transfers heat from hot regolith to cold regolith. The CoRHE is essentially a tube-in-tube heat exchanger with internal and external augers attached to the inner rotating tube to move the regolith. Hot regolith in the outer tube is moved in one direction by a right-hand - ed auger, and the cool regolith in the inner tube is moved in the opposite direction by a left-handed auger attached to the inside of the rotating tube. In this counterflow arrangement, a large fraction of the heat from the expended regolith is transferred to the new regolith. The spent regolith leaves the heat exchanger close to the temperature of the cold new regolith, and the new regolith is pre-heated close to the initial temperature of the spent regolith. Using the CoRHE can reduce the heating requirement of a lunar ISRU system by 80%, reducing the total power consumption by a factor of two. The unique feature of this system is that it allows for counterflow heat exchange to occur between solids, instead of liquids or gases, as is commonly done. In addition, in variants of this concept, the hydrogen reduction can be made to occur within the counterflow heat exchanger itself, enabling a simplified lunar ISRU (in situ resource utilization) system with excellent energy economy and continuous nonbatch mode operation.

Zubrin, Robert↗

Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers

The objective of this study is to experimentally evaluate two residential split heat pumps using low-GWP refrigerants, i.e., R452B and R454B, and compare the results against R410A. In this work, each heat pump used the same model of two-speed scroll compressor, the same indoor blower and outdoor fan. However, they were distinguished by the indoor and outdoor heat exchanger types: tube-fin heat exchangers (TFHXs) in one case, and microchannel heat exchangers (MCHXs) in the other. The two heat pumps were extensively evaluated following the test conditions for two-speed SEER (cooling seasonal energy efficiency rating)/HSPF (heating seasonal performance factor) ratings.In general, these results show that R452B and R454B are good replacement candidates for R410A for heat pump using tube-fin heat exchangers and microchannel heat exchangers. R452B and R454B led to lower capacities. In the TFHX heat pump, on average, compared to the performance of R410A, the cooling capacity of R452B is 96%; the heating capacity of R452B is 91%; the cooling capacity of R454B is 95%, the heat capacity of R454B is 89%. In the MCHX heat pump, the cooling capacity of R452B is 97%; the heating capacity of R452B is 97%; the cooling capacity of R454B is 98%, the heat capacity of R454B is 97%. With respect to cooling and heating seasonal performances, in the TFHX heat pump, the SEERs of R452B and R454B are 1.5% lower than R410A. HSPFs of the three refrigerants are identical. In the MCHX heat pump, R454B has 7% higher SEER, and R452B has 2% higher SEER than R410A; in heating mode, R454B has the same HSPF as R410A, while R452B is 4% more efficient. The compressor lubricant overheating issue of R452B and R454B, at low ambient heating condition, high stage, should be noticed.

42 ENGINEERING↗

A bi-directional two-phase/two-phase heat exchanger

This paper describes the design and test of a heat exchanger that transfers heat from one two-phase thermal loop to another with very small drops in temperature and pressure. The heat exchanger condenses the vapor in one loop while evaporating the liquid in the other without mixing of the condensing and evaporating fluids. The heat exchanger is bidirectional in that it can transfer heat in reverse, condensing on the normally evaporating side and vice versa. It is fully compatible with capillary pumped loops and mechanically pumped loops. Test results verified that performance of the heat exchanger met the design requirements. It demonstrated a heat transfer rate of 6800 watts in the normal mode of operation and 1000 watts in the reverse mode with temperature drops of less than 5 C between two thermal loops.

Ku, Jentung↗

Phase Change Material Heat Exchanger Life Test

Low Lunar Orbit (LLO) poses unique thermal challenges for the orbiting space craft, particularly regarding the performance of the radiators. The emitted infrared (IR) heat flux from the lunar surface varies drastically from the light side to the dark side of the moon. Due to the extremely high incident IR flux, especially at low beta angles, a radiator is oftentimes unable to reject the vehicle heat load throughout the entire lunar orbit. One solution to this problem is to implement Phase Change Material (PCM) Heat Exchangers. PCM Heat Exchangers act as a "thermal capacitor," storing thermal energy when the radiator is unable to reject the required heat load. The stored energy is then removed from the PCM heat exchanger when the environment is more benign. Because they do not use an expendable resource, such as the feed water used by sublimators and evaporators, PCM Heat Exchangers are ideal for long duration Low Lunar Orbit missions. The Advanced Thermal Control project at JSC is completing a PCM heat exchanger life test to determine whether further technology development is warranted. The life test is being conducted on four nPentadecane, carbon filament heat exchangers. Fluid loop performance, repeatability, and measurement of performance degradation over 2500 melt-freeze cycles will be performed and reported in the current document.

Lillibridge, Sean↗

Online Lead/Water Heat Exchanger Sensor/System Feasibility-PNNL (Final Report)

On-line structural health corrosion monitoring in advanced lead fast reactor heat exchangers and molten salt reactor heat exchangers is desirable for detecting tube degradation prior to leaks that may allow mixing of heat exchanger fluids or release of radiological contamination beyond the design containment boundary. This program, On-Line Lead/Water Heat Exchanger Sensor/System Feasibility – PNNL 76092, demonstrates feasibility for an ultrasonic torsional wave mode sensor attached to the outside of a long (30.5-m) heat exchanger tube in the stagnant flow area where the tube joins a heat exchanger plenum and where it is possible to protect a sensor and cable from high-force flows. The sensor must be cable connected to a monitoring instrument near the heat exchanger. The sensor and cable management approach for periodic in-service inspection will be impractical to implement on existing heat exchangers; rather permanently mounted sensors must be installed in conjunction with heat exchanger fabrication. Previous work has shown low-temperature lead zirconate titanate (PZT) piezoceramic sensors are able to detect anomalies of interest in 3.0-m long tubes. These sensors have hereby been extended to a 30.5-m long tube more representative of commercial power heat exchanger designs. The program will continue to investigate higher temperature piezoelectric ceramics and long-term performance of high temperature adhesives and sealants and mechanical pressure coupling for 350-500 °C lead reactor environments and higher temperature (700 °C) molten salt environments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of Condensing Ice Heat Exchangers for MTSA Technology Development

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal, carbon dioxide (CO2) and humidity control for a Portable Life Support Subsystem (PLSS). Metabolically-produced CO2 present in the ventilation gas of a PLSS is collected using a CO2-selective adsorbent via temperature swing adsorption. The temperature swing is initiated through cooling to well below metabolic temperatures. Cooling is achieved with a sublimation heat exchanger using water or liquid carbon dioxide (L CO2) expanded below sublimation temperature when exposed to low pressure or vacuum. Subsequent super heated vapor, as well as additional coolant, is used to further cool the astronaut. The temperature swing on the adsorbent is then completed by warming the adsorbent with a separate condensing ice heat exchanger (CIHX) using metabolic heat from moist ventilation gas. The condensed humidity in the ventilation gas is recycled at the habitat. The water condensation from the ventilation gas represents a significant source of potential energy for the warming of the adsorbent bed as it represents as much as half of the energy potential in the moist ventilation gas. Designing a heat exchanger to efficiently transfer this energy to the adsorbent bed and allow the collection of the water is a challenge since the CIHX will operate in a temperature range from 210K to 280K. The ventilation gas moisture will first freeze and then thaw, sometimes existing in three phases simultaneously.

Padilla, Sebastian↗

A heat exchanger computational procedure for temperature-dependent fouling

A novel heat exchanger computational procedure is described which provides a means of rapidly calculating the distributions of fluid and wall temperatures, deposit formation, and pressure loss at various points in a heat exchanger. The procedure is unique in that it is capable of treating wide variations in heat exchanger geometry without recourse to restrictive assumptions concerning heat exchanger type (e.g., co-flow, counterflow, cross flow devices, etc.). The analysis has been used extensively to predict the performance of cross-counterflow heat exchangers in which one fluid behaves as a perfect gas (e.g., air) while the other fluid is assumed to be a distillate fuel. The model has been extended to include the effects on heat exchanger performance of time varying inflow conditions. Heat exchanger performance degradation due to deposit formation with time can be simulated, making this procedure useful in predicting the effects of temperature-dependent fouling.

Chiappetta, L. M.↗

A Comparative Evaluation and Selection of High-Temperature Heat Exchangers for Application to Integrated Energy Systems

The following report aims to create a refined and well-structured method for comparatively evaluating heat exchanger technologies for integrated energy systems that caters customers’ specific needs while meeting engineering requirements. For the evaluation, this study elevates previous evaluation metrics, enhances the knowledge base via literature and market surveys, and identifies the figures of merit with robust rationales to enhance the quality of decisions made throughout the proposed heat exchanger evaluation process. The heat exchanger designs evaluated as part of the case study are shell and tube heat exchangers, printed circuit heat exchangers, plate heat exchangers, spiral heat exchangers, and heat pipe heat exchangers. The information presented in this report is meant for industries interested in making a preliminary screening process to identify the most suitable heat exchanger design for their application of interest.

42 ENGINEERING↗

A Comparative Evaluation and Selection of High-Temperature Heat Exchangers for Application to Integrated Energy Systems

The following report aims to create a refined and well-structured method for comparatively evaluating heat exchanger technologies for integrated energy systems that caters customers’ specific needs while meeting engineering requirements. For the evaluation, this study elevates previous evaluation metrics, enhances the knowledge base via literature and market surveys, and identifies the figures of merit with robust rationales to enhance the quality of decisions made throughout the proposed heat exchanger evaluation process. The heat exchanger designs evaluated as part of the case study are shell and tube heat exchangers, printed circuit heat exchangers, plate heat exchangers, spiral heat exchangers, and heat pipe heat exchangers. The information presented in this report is meant for industries interested in making a preliminary screening process to identify the most suitable heat exchanger design for their application of interest.

42 - ENGINEERING↗