Search NASA⌕ Search

SEARCH · Search NASA

Results for “heating demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗

Climate-Water-Electricity Interactions in the U.S. Under Alternative Decarbonized Futures

The U.S. electric sector is rapidly evolving, with widespread renewable energy deployment, building and transport electrification, and nuanced decarbonization policies. Climate change influences the supply and demand for electricity by altering water resources for cooling and hydropower, thermal plant efficiencies, and heating and cooling demand. This research combines global climate model data, asset-level water and streamflow modeling, and electric sector capacity expansion modeling to study climate-water-electricity interactions across myriad future climate and electricity scenarios that consider electrification and decarbonization using renewable, hydrogen, carbon capture, and nuclear technologies. Multi-model integration leads to insights into power-water sector interactions and their impacts on grid economics and environmental outcomes.

climate change↗

Heating and Cooling Energy Modeling of 3D-Printed Concrete Construction of Residential Buildings [Slides]

3D printed concrete construction (C3DP) is an emerging technology that comes with the associated benefits of high thermal mass walls. We investigated using BEopt software the heating and cooling energy use of a single story C3DP-constructed house. We then compared the heating/cooling energy use of the C3DP house against the corresponding energy use in a traditional timber (wood) frame construction (WFC), as well as a concrete masonry unit (CMU) construction. Both peak energy use for heating and cooling (Btu), as well as base energy use for both heating and cooling (MMBtu/yr) of the C3DP design were compared against the WFC and CMU baseline construction of identical geometries and orientations across all eight climate zones defined in the International Energy Conservation Code (IECC). The BEopt models for all three constructions (C3DP, WFC, and CMU) were built to comply with the 2018 IECC code. Results indicate that C3DP construction has significant heating and cooling energy benefits in certain climate zones, with the highest peak cooling energy savings (9% compared to WFC, and 5% compared to CMU) in the IECC Climate Zone 1 in the month of July. The peak heating and cooling energy demand reduction of C3DP were found to be more significant than the base heating and cooling energy demand in all IECC climate zones. The 2018 IECC compliance-related U-Factor adjustments of all models also resulted in more peak energy savings of the C3DP design in the cooling-dominated climate zones (climate zones 1 and 2), moderate energy savings in moderate climate zones (climate zones 3, 4, and 6), and little to no change in energy savings in very cold climates (climate zones 7 and 8).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Pilgrim Hot Springs: GEOPHIRES Inputs and Outputs for Direct-Use Geothermal District Heating and Cooling

This dataset includes files for a techno-economic analysis conducted using the GEOPHIRES simulator to examine the feasibility of expanding a larger district heating site in a remote location: Pilgrim Hot Springs, Alaska. Files included here are GEOPHIRES inputs and outputs for five different scenarios with varying demand, cycle, and system design characteristics to analyze. Also included is the link to the GEOPHIRES GitHub, as well as a link to the dataset that contains the energy modelling used to determine the heating demand for the district. For a list of the differences between scenarios, see the included "Input Overview.txt" file. Fields included in the input files are: subsurface technical parameters, surface technical parameters, financial parameters, capital and O&M parameters, as well as simulation parameters. The output files are case reports that summarize all equipment, reservoir characteristics, costs, and heating profiles.

15 GEOTHERMAL ENERGY↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct Electricity from Heat: A Solution to Assist Aircraft Power Demands

A thermionic device produces an electrical current with the application of a thermal gradient whereby the temperature at one electrode provides enough thermal energy to eject electrons. The system is totally predicated on the thermal gradient and the work function of the electrode collector relative to the emitter electrode. Combined with a standard thermoelectric device high efficiencies may result, capable of providing electrical energy from the waste heat of gas turbine engines.

Goldsby, Jon C.↗

Residential solar-heating system

Complete residential solar-heating and hot-water system, when installed in highly-insulated energy-saver home, can supply large percentage of total energy demand for space heating and domestic hot water. System which uses water-heating energy storage can be scaled to meet requirements of building in which it is installed.

Source record↗

Validation and moisture content sensitivity analysis of cross-laminated timber wall assemblies in EnergyPlus

Cross-laminated timber buildings are becoming more common in North America, with many numerical studies showing potential energy savings. However, no studies have validated any EnergyPlus heat transfer algorithms or quantified their accuracy in simulating CLT in building envelopes. This study empirically validates the heat flux predictions for each of EnergyPlus's heat transfer algorithms (Conduction Transfer Functions (CTF), Effective Moisture Penetration Depth (EMPD), Conduction Finite Difference (CondFD), and Heat and Moisture Transfer (HAMT)) for two different CLT ply thicknesses with both summer and winter boundary conditions measured in controlled lab experiments. It also evaluates the model sensitivity of heat flux and heating and cooling loads to moisture content. The 1D validation shows that the HAMT model is the most accurate among all algorithms. All EnergyPlus's heat flux predictions are accurate independent of CLT plate thickness for summer conditions. However, the three constant property algorithms (CTF, EMPD, and CondFD) underpredict heat flux throughout the whole day during winter conditions. The 1D sensitivity analysis indicates that elevated moisture content can increase peak heat fluxes through the material by up to 20 %. Finally, the whole building model sensitivity analysis shows increased heating load and slight cooling load variation due to increased moisture content when using constant property models. The analysis shows significantly lower peak thermal demand (7 % lower heating and 6 % lower cooling) and monthly thermal load (8 % less cooling and 6 % less heating) predictions when using HAMT vs a constant property model.

42 ENGINEERING↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

A dynamic volumetric heat source model for laser additive manufacturing

Melt pool scale models of laser powder bed fusion (LPBF) offer insights into the process-structure-property relationships in additive manufacturing (AM). These models often neglect physical phenomena such as vapor cavity formation and fluid mechanics to reduce computational demands. Instead, volumetric heat source models are used to represent the effects that these phenomena have on the predicted melt pool dimensions. Generally, the dimensions and effective absorption of the volumetric heat source are calibrated to reproduce melt pool dimensions observed in metallographic cross sections taken from single-track experiments on bare plate. However, the transient nature of LPBF often deviates the melt pool dimensions from the assumed steady-state conditions of single-track experiments, motivating the need for a volumetric heat source model that more generally considers the dynamic relationship between melt pool shape and laser-material interactions. Here, we introduce a two-parameter volumetric heat source model that integrates several existing models into a generalized mathematical expression, providing independent control over the radial heat distribution via the parameter k and the volumetric shape of the heat source via the parameter m. This parameterization enables the calibration of melt pool shape predictions through simultaneous adjustment of these parameters, while keeping the radial heat source dimensions consistent with the experimental spot size (D4σ) and constraining the heat source depth and absorption to physically derived expressions for cavities. Consequently, the proposed volumetric heat source model adapts to changes in the local melt pool conditions due to scanning strategy and part geometry by dynamically adjusting the heat source depth and absorption. We demonstrate the capabilities of the proposed model through comparisons with a collection of experiments from the Additive Manufacturing Benchmark (AMBench).

36 MATERIALS SCIENCE↗

Solar energy system performance evaluation. Seasonal report for Colt Pueblo, Pueblo, Colorado

The Colt-Pueblo solar energy system, designed to provide space heating and hot water preheating, is described and its operational performance for a 12 month period from February 1979 through January 1980 is evaluated. The space heating subsystem met 31 percent of the measured space heating load which was close to the expected 34 percent solar fraction. Although the hot water solar fraction was 79 percent, the overall energy saving capability was reduced because of the low hot water demand. The measured heating subsystem performance would have improved considerably if the uncontrolled losses primarily from transport piping could have been reduced to an inconsequential level. Fossil energy savings of 70.31 million BTUs are estimated.

Source record↗

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]↗

The Urban Heat Island Pilot Project (UHIPP)

Urban heat islands increase the demand for cooling energy and accelerate the formation of smog. They are created when natural vegetation is replaced by heat-absorbing surfaces such as building roofs and walls, parking lots, and streets. Through the implementation of measures designed to mitigate the urban heat island, communities can decrease their demand for energy and effectively "cool" the metropolitan landscape. Measures to reverse the urban heat island include afforestation and the widespread use of highly reflective surfaces. To demonstrate the potential benefits of implementing these measures, EPA has teamed up with NASA and LBNL to initiate a pilot project with three U.S. cities. As part of the pilot, NASA is using remotely-sensed data to quantify surface temperature, albedo, the thermal response number and NDVI vegetation of each city. To pursue these efforts, more information is needed about specific characteristics of several different cities. NASA used the Advanced Thermal and Land Applications Sensor (ATLAS) to obtain high spatial resolution (10 m pixel resolution) over each of the three pilot cities (Baton Rouge, Sacramento, and Salt Lake City). The goal of the UHIPP is to use the results from the NASA/LBNL analysis, combined with knowledge gained through working with various organizations within each pilot city to identify the most effective means of implementing strategies designed to mitigate the urban heat island, These "lessons learned" will be made available and used by cities across the U.S. to assist policy makers and others within various communities to analyze their own urban heat islands and determine which, if any, measures can be taken to help save energy and money, and to prevent pollution. The object of this session is for representatives from each of the pilot cities to present their results of the study and share the experience of working with these data in managing their urban landscape.

Luvall, Jeff↗

The Empirical Effect of Fleet Optimization on Synchronization and Rebound Effects in Heat Pump Water Heaters

Demand response is a growing concept in light of the internet of things and an increasing need for grid flexibility. Water heaters are one of the preferred devices for providing demand response for grid services and peak management due to their capability to store energy. The efficient use of water heaters for demand response requires consideration of the associated load effects such as synchronization of device schedules and rebound effect. These effects present a significant challenge. Despite the importance of the mentioned effects for water heater queuing and scheduling, there has been no effort to quantify and empirically validate their impact. This study attempts to address this gap by offering two methods - Ward clustering and Euclidean K-means - to evaluate the extent of synchronization in a fleet of 42 water heaters in Atlanta, GA. Using the aforementioned methods on the measured data, we find evidence of convergence of water heater loads as a result of optimization compared to an idle period and analyzed their impact.

demand response↗

Optimal operations of a nuclear-based integrated energy system: A mixed integer program approach

A nuclear-based integrated energy system (IES), consisting of multiple carbon-free energy generation and conversion technologies to meet heterogeneous end-use demands, offers a promising approach to decarbonizing the U.S. economy. Operating such an IES is challenging due to its complexity and the diverse end-use demands, such as heating and electricity. This paper aims to address the optimal operation of an IES composed of a small modular reactor (SMR), a steam manifold, a balance of plant (BOP), a high-temperature steam electrolysis (HTSE) system, a district heating (DH) network, and electrical grids. We formulate the system’s operation as a mixed integer linear programming (MILP) problem to maximize net revenues from sales of electricity and hydrogen. To evaluate the efficacy of the proposed model, we conduct a 24-hour simulation considering day-ahead (DA) electricity prices from CAISO and a varying DH demand profile with hourly resolution. The simulation results show that our model effectively optimizes the operation by selling electricity during on-peak periods and purchasing electricity for hydrogen production during off-peak periods, while satisfying operating constraints within the IES.

08 HYDROGEN↗

Techno-Economic Analysis and Market Potential of Geological Thermal Energy Storage (GeoTES) Charged With Solar Thermal and Heat Pumps

In this project, we developed a techno-economic analysis (TEA) model that can be used to evaluate the viability of a proposed Geological Thermal Energy Storage (GeoTES) design. This MATLAB-based model integrates distinct subsystem models for the reservoir, wells, power cycle, and solar field to capture their distinct characteristics. It applies this approach in simulating GeoTES storage and dispatch operations for durations ranging from hourly to seasonal. Using cases studies based on GeoTES designs provided by industry partners - Premier Resource Management (PRM) and EarthBridge Energy - we validated the TEA model estimations of system performance and costs (such as thermal and electrical power/energy inflow and outflow, capital costs, and levelized costs of energy and storage) for both concentrating solar thermal (CST) and Carnot Battery (CB) pairings with GeoTES (CST-GeoTES and CB-GeoTES). For the CST-GeoTES case, the model was validated against the proposed system designed by PRM. It showed good agreement with PRM's estimations when well and pump costs derived from PRM's estimations were used. When GETEM-based costs were used, there was a slight overprediction due to GETEM's project/site agnostic assumption of these costs. From a sensitivity analysis perspective, the levelized cost of electricity (LCOE) of the CST-GeoTES case was most sensitive to well flow rate and the charging temperature. An optimal design scenario resulted in an LCOE of 0.11 $\$$/kWhe. CST-GeoTES can also provide a source of heat to meet seasonal demands. With 12-hour and 24-hour levelized cost of heat (LCOH) of 0.018 $\$$/kWhth and 0.022 $\$$/kWhth, respectively, CST-GeoTES could be competitive in the California market with an average industrial price of natural gas in California between 0.041-0.047 $\$$/kWhth. The levelized cost of storage (LCOS) for CST-GeoTES depends on the energy storage duration. Although the LCOS is relatively higher for shorter durations (e.g., ~0.50 $\$$/kWhe for 1 hour of storage), it is an order of magnitude lower (0.06 $\$$/kWhe) for longer storage durations and competitive with lithium-ion batteries (beyond 12 hours of storage) and molten-salt thermal energy storage (beyond 32 hours). Energy. Three options were explored and applied to the EarthBridge case study: (1) A Carnot Battery design using R125 working fluid with both hot and cold storage; (2) A Carnot Battery design using R125 working fluid with only hot storage; (3) A Carnot Battery using a commercially available heat pump with carbon dioxide (CO2) working fluid and hot storage only. The CB-GeoTES with cold storage only had a slight (round-trip) efficiency advantage over the system without (43.4% vs. 42.8%). This is because the cold storage is limited by the freezing point of water, so the cold storage is not much colder than the environment. The system using commercially available technologies was the least efficient - partly because different cycles were used in the heat pump (CO2) and heat engine (binary cycle) which leads to some inefficiencies. Using the commercially available design, the levelized cost of energy (LCOS) from the model (0.10 $\$$/kWhe) was higher than that estimated by EarthBridge (0.068 $\$$/kWhe). This is because of the low round-trip (38.7%) efficiency of the commercially available design. Sensitivity analysis reveals that the model is most sensitive to electricity price. Including electricity price in the TEA for CB-GeoTES leads to an increase in LCOS from the base value to 0.25 $\$$/kWhe. To determine storage sites suitable for GeoTES, we gathered and analyzed geological, petrophysical, and geophysical data of oil and gas reservoir and aquifers in California and Texas. We down-selected possible sites based on cut-off values for site characteristics (e.g., reservoir temperature, formation thickness, permeability, porosity, depth, and brine salinity) and preliminary costs. Using this approach, the Carrizo-Wilcox, Yegua-Jackson, and Dockum brackish aquifers in Texas were identified as having the highest suitability. Similarly, in the central California region, the White Wolf, Belridge South Tulare, and Belridge South Reef Ridge were the most suitable. Going further, we assessed the storage potential in the selected sites. To do this we developed distributions of reservoir characteristic data and applied a Monte Carlo-based analysis to account for intrinsic uncertainty in the acquired data. The analysis revealed that the Carrizo-Wilcox aquifer had the highest storage potential with a mean capacity of 554 TWhth (i.e., 63 TWhe). The estimated capacity serves as an upper limit of storage potential given that not all fields in the basin will be developed. We participated in multiple outreach activities including conference presentations, panel session discussions, and the facilitation of a GeoTES workshop at the NREL Golden campus.

15 GEOTHERMAL ENERGY↗

Nexus of electrification and energy efficiency retrofit of commercial buildings at the district scale

Rapid electrification of buildings at the district scale is needed for cities to achieve climate change mitigation goals. However, most electrification studies focus on either the single building level or the city/region building stock level, and depend on the slow and uncertain process of requesting personally identifiable customer energy usage data from utilities. To answer a key question facing local policymakers: “Where can electrification proceed at scale without first upgrading the grid?” this study aims to quantify and inform building electrification impacts at the district scale using detailed building energy modeling and based on public records datasets. We explore how energy efficiency retrofits can help mitigate increased peak electric demand, and quantify impacts to energy use and carbon emissions. Building energy models of a baseline, and scenarios of simple electrification, energy retrofits, and electrification in combination with retrofits were created and simulated for 54 commercial buildings in two contiguous districts of San Francisco. A simple electrification scenario increased annual electricity consumption but reduced annual site energy usage by 15% to 17%, mainly due to replacing inefficient gas furnaces and boilers with more efficient heat pumps. Peak demand increased 7.4% for Fisherman's Wharf (e.g. within the capacity of the existing power grid), while the Design District showed a marginal decrease. Annual carbon emissions were reduced by 46% and 37%. Combining electrification with efficiency upgrades reduced peak demand by 26% and 40%, and annual carbon emissions by 63% and 64% for the two districts. Furthermore, these results indicate that impacts of electrification depend on the mix of building uses within a district, and coupling electrification with energy efficiency upgrades is an effective strategy to decarbonize buildings while maintaining or reducing the peak electric demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗