Search NASA⌕ Search

SEARCH · Search NASA

Results for “heliostats”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Wind Loading on CSP Collectors

The project significantly enhanced the community's understanding of the fundamental physics drivers underlying the wind-loading experienced by concentrating solar power (CSP) collector structures (i.e., parabolic troughs and heliostats) as well as their support structures. This project had two overarching objectives: (1) detailed measurements to characterize the prevailing wind conditions and resulting operational loads on collector structures, and (2) development and validation of a computationally efficient, high-fidelity modeling tool capable of predicting wind-loading in deep-array installations. Over three years, we conducted comprehensive at-scale field measurements of the atmospheric turbulent wind conditions, and the resulting wind loads on parabolic troughs and heliostats. Two at-scale measurement campaigns yielded first-of-its-kind, high-resolution, long-term datasets that are used to characterize the complex flow field and wind loading on parabolic-troughs and heliostats in operational power plants. The high-resolution measurements collected during these campaigns were used to validate the high-fidelity computational models developed at NREL. These open-source computationally efficient models were shown to be accurate in predicting wind-driven loads on collectors without the need for a large supercomputer.

14 SOLAR ENERGY↗

Improvements in Mirror Surface Measurement with Reflected Computer Vision Targets

Over the last several years, NREL has been developing a system to measure large optical surfaces of heliostat mirrors by reflecting computer vision targets. An advantage of this system, called Reflected Target Nonintrusive Assessment (ReTNA), is that it lends itself well to stitching together many images, each reflecting only part of a larger heliostat. In the last few months, this was taken to a new extreme, with a small target (<5m2) being used to measure a >25m2 long focal length heliostat. These measurements were compared with traditional fringe deflectometry methods, which require a >50m2 target, and photogrammetry. The strengths, weaknesses and limitations of ReTNA are discussed. An estimated uncertainty in this new measurement is presented, along with software improvements and a new wireless data collection system. A bill of materials for this measurement system is presented, which has been designed to use all low-cost, off-the-shelf components. Finally, the next steps for future ReTNA development are presented. Overall, ReTNA can be a valuable optics measurement system, complimentary to existing measurement techniques available for large reflective surfaces.

14 SOLAR ENERGY↗

Metrology and Standards Gaps and FY27 Work Focusing on Impact

This work focuses on the Heliostat Consortium (HelioCon) optical measurements and characterization, testing and modeling capabilities and infrastructure at NLR and Sandia supporting heliostat technology research, development, validation, and deployment in relevant industries. The development of standards in HelioCon requires a collective effort across the global heliostat community of industry, researchers, academia and other stakeholders.

14 SOLAR ENERGY↗

Development of the Generation 3 Particle Pilot Plant Falling Particle Receiver

A falling particle receiver (FPR) has been designed to integrate with the G3P3-USA pilot plant currently being constructed at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories. This receiver integrates several innovative design features including a converging tunnel (SNOUT), an optimized cavity geometry, and a multistage “catch-and-release” trough. Details about the integration of these features and the final G3P3-USA FPR design and construction are described. Ray-tracing models of the FPR utilizing the NSTTF heliostat field are developed leveraging previous modeling efforts using SolTrace. Models demonstrate that at least 1.5 MWth of incident radiative energy can be provided to the FPR on a clear day throughout a typical year in Albuquerque, NM. Spillage fluxes around the periphery of the aperture are within acceptable bounds for the majority of the year. Intercept factors are computed for each utilized heliostat at the Vernal equinox to provide guidance to heliostat operators during operation of the system.

Mills, Brantley↗

Field Deployable Mirror Soiling Detection Based on Polarimetric Imaging

Heliostat mirror soiling is one of the significant factors for reduced optical efficiency of Concentrated Solar Power (CSP) fields. However, it remains challenging to determine the mirror soiling patterns across the large area of the CSP field. Here we propose a fast and field deployable inspection method to measure the heliostat mirror soiling levels based on polarization images in regular daylight settings without additional light sources. Under sunny and clear sky conditions, we have demonstrated accurate measurement of reflection efficiency (error ~1%) for mirrors with different soiling levels.

14 SOLAR ENERGY↗

Effect of Quartz Aperture Covers on the Fluid Dynamics and Thermal Efficiency of Falling Particle Receivers

Falling particle receivers are an emerging technology for use in concentrating solar power systems. In this paper, quartz half-shells are investigated for use as full or partial aperture covers to reduce receiver thermal losses. Quartz half-shell aperture covers offer the ability to minimally interfere with incoming solar radiation from the heliostat field while obstructing thermal radiation and advection from leaving the receiver cavity. The fluid dynamics and heat transfer of a receiver subdomain and surrounding air are modeled using ANSYS®FLUENT We compare the percentage of total incident solar power lost due to conduction through the receiver walls, advective losses through the aperture, and radiation exiting the aperture. Contrary to expected outcomes, results show that quartz aperture covers can increase radiative losses and result in modest to nonexistent reductions in advective losses. The increased radiative losses are driven by elevated quartz half-shell temperatures and have the potential to be mitigated by active cooling and/or material selection. Quartz half-shell total transmissivity was measured experimentally using a radiometer and the National Solar Thermal Test Facility heliostat field with values up to 0.97 ± 0.01. Quartz half-shell aperture covers did not yield expected efficiency gains in numerical results due to increased radiative losses, but efficiency improvement in some numerical results and the performance of quartz half-shells subject to concentrated solar radiation suggest that quartz half-shell aperture covers should be investigated further.

14 SOLAR ENERGY↗

BCS (CSP Beam Characterization System) [SWR-23-13]

The Beam Characterization System (BCS) is an image-processing tool for estimating heliostat tracking errors. A large mirror, or heliostat, reflects the sun onto a distant target. A carefully calibrated camera then takes an image of this target to capture the shape of the reflected beam. The software kit hosts a series of scripts to identify key features and run analysis on the captured images.

Kesseli, Devon↗

SOFAST CAD Layout Tool Overview and User Guide (Document Version 1.0)

Concentrating solar mirrors need to have correct geometry to accurately focus sunlight onto a receiver. SOFAST is a tool created at Sandia National Laboratories which measures a mirror’s surface normal at a dense sampling of points, enabling evaluation of a given mirror’s expected performance. SOFAST supports general mirrors, including concentrating solar heliostats, troughs, and dishes. The examples presented in this report predominantly focus on heliostats.

14 SOLAR ENERGY↗

National Solar Thermal Test Facility: Operations & Maintenance Report

The NSTTF O&M Project continues the operation and maintenance activities of the existing critical capabilities and infrastructure at the NSTTF. This project is to support and assure the success of Solar Heat for Industrial Process in the United States and the larger global community by ensuring the NSTTF is a safe and operational facility. The primary goal of this project will be to maintain the solar tower and heliostat field while also allowing NSTTF staff to improve processes for operations and maintenance. This includes expanding our preventative maintenance program, inventory systems, and our data sharing capabilities. Additionally, this will support an outreach program with regular seminars, sharing of data, and the release of open-source software to support heliostat metrology

14 SOLAR ENERGY↗

AATTENUATION—The Atmospheric Attenuation Model for CSP Tower Plants: A Look-Up Table for Operational Implementation

Attenuation of solar radiation between the receiver and the heliostat field in concentrated solar power (CSP) tower plants can reduce the overall system performance significantly. The attenuation varies strongly with time and the average attenuation at different sites might also vary strongly from each other. If no site specific attenuation data is available, the optimal plant design cannot be determined and rough estimations of the attenuation effect are required leading to high uncertainties of yield analysis calculations. The attenuation is caused mainly by water vapor content and aerosol particles in the lower atmospheric layer above ground. Although several on-site measurement systems have been developed during recent years, attenuation data sets are usually not available to be included during the plant project development. An Atmospheric Attenuation (AATTENUATION) model to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity, and barometric pressure measurements was developed and validated by the authors earlier. The model allows the accurate estimation of attenuation for sites with low attenuation and gives an estimation of the attenuation for less clear sites. However, the site-dependent coefficients of the AATTENUATION model had to be developed individually for each site of interest, which required time-consuming radiative transfer simulations, considering the exact location and altitude, as well as the pre-dominant aerosol type at the location. This strongly limited the application of the model despite its typically available input data. In this manuscript, a look-up table (LUT) is presented which enables the application of the AATTENUATION model at the site of interest without the necessity to perform the according complex radiative transfer calculations for each site individually. This enables the application of the AATTENUATION model for virtually all resource assessments for tower plants and in an operational mode in real time within plant monitoring systems around the world. The LUT also facilitates the generation of solar attenuation maps on the basis of long-term meteorological data sets which can be considered during resource assessment for CSP tower plant projects. The LUTs are provided together with this manuscript as supplementary files. The LUT for the AATTENUATION model was developed for a solar zenith angle (SZA) grid of 1°, an altitude grid of 100 m, 7 different standard aerosol types and the standard AFGL atmospheres for mid-latitudes and the tropics. The LUT was tested against the original version of the AATTENUATION model at 4 sites in Morocco and Spain, and it was found that the additional uncertainty introduced by the application of the LUT is negligible. With the information of latitude, longitude, altitude above mean sea level, DNI, relative humidity (RH), ambient temperature (Tair), and barometric pressure (bp), the attenuation can be now derived easily for each site of interest.

14 SOLAR ENERGY↗

Investigation of Flux Spreading in a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating

Concentrating solar thermal power (CSP) technology development has recently focused on increasing the operating temperatures to accommodate high efficiency power cycles and thermochemical processes. Inert solid particles as heat transfer media enable solar receivers to operate above 700 degrees Celsius resulting in increased system thermal efficiency compared to the conventional molten salt based CSP system. An open-cavity falling-particle solar receiver that can efficiently heat particles by direct heating from concentrated solar radiation faces challenges with large particle losses from wind and unable to support thermochemical reactions. A light-trapping, planar cavity reiver (LTPCR) where particles are indirectly heated can significantly minimize the particle losses during the operation, support thermochemical reactions, and offer scalability potential. The LTPCR features an array of vertical planar receiver/absorber panels arranged within a cavity configuration. Concentrated solar radiation from heliostats is focused onto the receiver walls, where heat is indirectly transferred to solid particles flowing inside the receiver channels. Heat transfer occurs through direct contact between the receiver panel walls and particles, and can be enhanced by fluidizing particles with air. This fluidization increases particle-wall contact and extends particle residence time, maximizing heat transfer efficiency. The unique vertical planar receiver structure originated from a near-blackbody tubular light absorber, effectively distributing the incoming solar beam spread across the panel walls and trapping light. This flux spreading effect, driven by cosine projection, converts high incident solar flux into a lower, more uniform heat flux on the panel walls. This redistribution enhances heat transfer efficiency between particle-wall or reaction gases-wall, while preventing localized overheating of the receiver panel. Indirect planar cavity solar receivers completely separate solid particles from the ambient environment that can greatly reduce the thermal losses in heated particles resulting in high efficiency at high temperatures above 700 degrees Celsius. This design ensures no particle losses to the environment during the operation while open-cavity designs can experience significant particle losses from wind. An experimental investigation was conducted to observe flux spreading on the receiver panel wall. A lab-scale prototype planar receiver, fabricated using Haynes 230 alloy, was tested under direct concentrated solar radiation using the high-flux solar furnace (HFSF) facility at NREL. The experiment was performed under normal peak radiative heat fluxes ranging from 800 to 1900 kW/m2. A temperature distribution on the panel wall was measured using a thermal imaging camera (FLIR A 6600). To prevent overheating at the receiver front tip, prism-shaped heat shields (Zircar UNIFROM C1) were placed in front of the receiver, and their influence on flux spreading was also studied. Absorbed flux distribution on the panel wall was modeled using SolTrace. The total solar power and flux distributions delivered from HFSF were determined based on the heliostat mirror optical properties, direct normal irradiance (DNI) on the on-sun testing days, peak flux measurement during the on-sun testing, and shutter/attenuator settings Due to the large incident angles of the solar beam on the panel wall, the angular optical properties of Haynes 230 alloy and Zircar heat shields were incorporated into the model. This flux distribution model was then integrated into a computational fluid dynamics (CFD) simulation to predict the receiver panel wall temperature, which was compared with the experimental measurements. Both prediction and measurements identified a temperature hotspot at the backside of the panel, indicating that the incident solar beam can fully reach to the rear of the receiver. The heat shields positioned at the front of the receiver effectively reduced the excessive temperature rise at the receiver front tip. Overall, the temperature was well distributed over the panel wall, with a minor hotspot at the back of the receiver. The model slightly overpredicted the temperature, possibly due to discrepancies in optical properties of the panel and an underprediction of thermal loss in the receiver. The advancement of the particle LTPCR offers a viable alternative to open-cavity receivers by addressing particle loss issues. Additionally, it presents a pathway for enabling solar thermochemical processes, extending CSP technology beyond power generation to fuel and chemical production.

14 SOLAR ENERGY↗

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP↗

Advancements in reflected target nonintrusive assessment (ReTNA) for large optical surface measurement

Reflected computer vision targets are a powerful tool for measurement of mirror surface shape, with several important advantages over traditional fringe deflectometry methods. This method was first presented in 2021 and has undergone significant improvement and demonstration since. We describe a new baseline system using reflected computer vision targets, and present results from a large-scale measurement campaign conducted on both commercial heliostats and test mirrors in the laboratory. Calibration of the measurement system with photogrammetry allows for accurate measurement without careful control of target shape or camera position. Overall, the results show that a baseline setup using this method achieves measurement uncertainties in the slope error root-mean-square less than ±0.11 milliradian due to a series of repeatability conditions, varying sample position, rotation, lighting, camera settings, and system rebuild and recalibration. We present a detailed description of the setup, the results generated by this measurement tool, repeated measurement results, and the strengths and limitations of this metrology system.

14 SOLAR ENERGY↗

Techno-Economic Analysis of CSP Incorporating sCO2 Brayton Power Cycles: Trade-Off Between Cost and Performance

Concentrating solar power (CSP) plants, thanks to the implementation of cost-competitive thermal energy storage, represent a dispatchable zero-emission alternative to traditional fossil fuel power plants. Next generation solar towers are expected to adopt high temperature receivers (>700 degrees C) coupled to sCO2-based power blocks, which optimal design is generally pushed towards the maximum cycle efficiency, often neglecting the economic impact with the justification that the main share of the capital cost is represented by the heliostat field. As result, the scientific literature lacks in comprehensive studies on techno-economic evaluation of CSP+sCO2 power plants addressing the important correlation that exists between system cost and performances. This work provides a preliminary techno-economic analysis of a solar power tower comparing four different cycle configurations for the sCO2 power block. Results have been reported on a Pareto front, highlighting the tradeoff between the plant investment cost and the solar-to-electricity plant efficiency. The trends of the optimization variables and cycle results have been reported to give useful insights about proper assumptions for the sCO2 power block design. The recompressed cycle with intercooling resulted as the most promising configuration and it has been further analyzed through a comparison of different solutions on the Pareto front. The cost breakdown of the sCO2 power block has been reported to highlight which components have the greatest impact on the overall plant cost and how they vary along the optimal solutions front. Eventually, the optimization has been repeated introducing a correlation to compute the turbomachinery isentropic efficiencies, to investigate their effect on the techno- economic analysis.

concentrated solar power↗

Chapter 4: Solar Collectors for CSP

The following sections are included in the chapter: Parabolic Trough Concentrating Collectors; Heliostats; Dish; Linear Fresnel; Advanced Concepts - Metasurfaces; Acknowledgment; References.

heliostats↗

NLR CSP Optical Facilities: Illuminating the Path Forward Through Innovation and Impact: Agreement 38490

This initiative is a multi-faceted project at the National Laboratory of the Rockies (NLR) aimed at strengthening its Concentrating Solar Power (CSP) Optical Facilities to advance the development of low-cost, high-performance materials for solar and other applications. The project's strategy is built on three pillars: strategic stakeholder engagement, diligent facility maintenance and utilization, and the development of new research capabilities. The overarching goal is to ensure the facilities remain state-of-the-art resources for industry and academia, thereby accelerating the conversion of concentrated sunlight into energy. A key driver of the project is an international Advisory Board, which provides critical guidance on research priorities and industry needs, leading to new collaborations and secured funding. This external engagement, combined with proactive outreach to industry partners, ensures the lab's work remains aligned with real-world challenges, including materials durability and performance certification. Significant efforts in facility maintenance have addressed challenges with aging infrastructure. Notable achievements include the complete refurbishment of the hail-damaged Ultra-Accelerated Weathering System (UAWS) and the successful replacement of a failing 15-year-old Lambda 1050 spectrophotometer with a new-generation model, substantially upgrading material characterization capabilities. These maintenance activities were complemented by achieving a prestigious ISO 9001:2015 certification for the Advanced Optical Materials Labs, formally recognizing the quality and reliability of NLR's measurement capabilities. Despite these successes, challenges remain, including high demand for the High Flux Solar Furnace (HFSF) and intermittent failures of other key instruments. The project has delivered major advancements in research techniques and capabilities. At the Flatirons campus, a new indoor laboratory, was established to house advanced deflectometry and photogrammetry systems for heliostat characterization. For on-sun testing, a novel, actively cooled turning mirror was developed for the HFSF, enabling more realistic testing of particle receivers and components. A collaboration with Virginia Tech successfully demonstrated the high-temperature durability of a new solar absorber coating through extensive cyclic testing. Concurrently, new modeling took place to better predict material degradation on rough, fractal surfaces. In summary, this project has systematically enhanced NLR's CSP Optical Facilities through strategic upgrades, rigorous maintenance, and stakeholder-guided research. By overcoming equipment failures, budgetary constraints, and logistical hurdles, the project has reinforced NLR's role as a central hub for CSP innovation and materials testing. Future work will focus on securing diverse funding, expanding collaborations, and continuing to provide the critical infrastructure needed to accelerate the development and deployment of next-generation technologies.

14 SOLAR ENERGY↗

Improvements in Optical Surface Measurement Using Reflected Computer Vision Targets

Since 2021, NREL has been developing a system to measure heliostats by measuring the deflection of printed computer vision targets, called the Reflected Target Non-intrusive Assessment (ReTNA) [6], [7]. While this system will have lower resolution than a fringe deflectometry system, it has several important advantages that make it a complimentary technology: 2D surface slope measurement can be generated from a single image, it can operate in ambient lighting, target points can be directly located in 3D space with photogrammetry allowing for a non-flat target, and it's well suited to using a smaller target, and multiple images to measure larger optical surfaces. ReTNA has undergone several significant changes and improvements, described below. This talk will summarize new system layouts designed for commercial use, new computer vision algorithms used to automate the analysis process and validation campaigns for the ReTNA software.

computer vision↗

Dynamic optimization and economic evaluation of flexible heat integration in a hybrid concentrated solar power plant

Hybridization of concentrated solar power (CSP) plants provides flexibility in operation that can drastically improve the solar-to-electric (STE) efficiency and levelized cost of electricity (LCOE) relative to standalone CSP plants. Flexible heat integration (FHI) is a novel concept where the collection and integration of CSP within a power plant is modified relative to the amount of solar energy available. FHI improves the thermal efficiency of a hybrid solar tower steam Rankine cycle power plant but leads to increased pumping needs due to continuously elevated molten salt flow rates through the collection system, which can negatively impact STE efficiency. The present work is carried out to maximize the STE efficiency of a hybrid CSP plant utilizing FHI by employing a dynamic optimization framework where a genetic algorithm optimizes the operation of the plant over a given solar irradiance profile. The study concerns a plant hypothetically located in Salt Lake City, Utah. Here, the optimization results confirm the accuracy of a predictive heuristic where the preferred operation of the plant can be estimated relative to local peaks in the incident power generated by the heliostat collection field. The optimized FHI operation demonstrates a yearly STE efficiency of 13.8%, whereas the equivalent base-level hybrid and solar-only plants exhibit solar efficiencies of 13.4% and 11.2%, respectively. Economic analysis shows that FHI reduces yearly natural gas costs, leading to a $\$0.5$/MWh reduction in LCOE relative to the base-level hybrid configuration. Overall, the results show that hybrid FHI schemes exhibit economic benefits along with observed thermodynamic improvements.

14 SOLAR ENERGY↗