Search NASA⌕ Search

SEARCH · Search NASA

Results for “high enthalpy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A High Angle of Attack Inviscid Shuttle Orbiter Computation

An accurate description of the aerothermal environment is required to minimize the weight of the Thermal Protection System required on the leeside of winged reentry vehicles. The inability of ground-test facilities to reproduce the high enthalpy, separated flow present during reentry flight conditions, coupled with the prohibitive expense of flight tests, leads to the use of an analytical method - namely Computational Fluid Dynamics (CFD) - to describe the flow. While the ultimate goal of this work is to accurately predict the leeside flow and its associated thermal environment, an essential and reasonable first step towards that goal is a comparison of pressure predictions by a code with wind-tunnel data. Until such CFD pressure predictions agree with wind-tunnel test cases, there is little hope of accurately predicting the thermal environment at flight conditions. Thus, the objective of this study is to compare the pressure distributions predicted by inviscid, perfect gas CFD to Shuttle Orbiter wind-tunnel data and to address any significant issues encountered during the computation. While flight data is available for the Shuttle Orbiter, a wind-tunnel case is chosen for this study to allow a tractable problem for preliminary investigation. A wind-tunnel case allows the perfect gas assumption for the flow chemistry. This provides a significant computational savings over a several species finite-rate chemistry model which would be necessary if high-temperature effects present at flight conditions were to be included. In addition, by concentrating on the surface pressures, the analysis need only consider inviscid flow for general evaluation of the code capability. This further reduces the computational expense due to the absence of viscous terms and the associated decrease in the number of points required for the computational grid. Previous computational efforts (such as STEIN and HALIS) have been directed toward the windward surface quantities, primarily due to restrictions in treating either the winged geometry or its associated subsonic regions at high angle of attack. The code used for this study, the LAURA (Langley Aerothermodynamic Upwind Relaxation Algorithm) code of Gnoffo, represents a state-of-the-art code for computing the flow over complex configurations at hypersonic speeds. In the study, the LAURA code is applied to a wind-tunnel condition to initiate the assessment of the code's ability to predict the flow over a relatively complex hypersonic vehicle at high angles of attack. This presentation is used to highlight the pertinent results of a more detailed investigation of the inviscid calculation over the Shuttle Orbiter with the LAURA code.

William L. Kleb↗

Aerothermodynamic Measurements in Hypersonic Non-Equilibrium Flows

High enthalpy arc-jets are unique facilities particularly suited for simulating complex flows in the aerospace field, such as the aerothermodynamics of a re-entry vehicle. Arc-jets are often used to evaluate important design factors such as heat shield materials and vehicle design. Characterization of these facilities is important, as studies often match specific in-flight environments during experiments. Due to the complex environment produced by an arc-jet, with effects such as thermodynamic and chemical non-equilibrium occurring in the flow, characterization experiments are significantly more difficult than in traditional blow-down wind tunnels. The current work aims to characterize an arc-jet facility in terms of flow temperature, velocity and unsteadiness, in a spatially-resolved analysis. To achieve this goal, a non-intrusive imaging technique called “planar laser-induced fluorescence” was performed in the NASA Langley Hypersonic Materials Environ-mental Test System arc-jet facility. The experimental data was analyzed to produce the quantitative measurements in multiple regions of the flow around a blunt body sample. A quasi-1D low fidelity solver was created to numerically simulate the flow to investigate non-equilibrium effects occur-ring outside the imaging region in the arc-jet nozzle. Unsteadiness in the test section was minimized by analyzing a subset of data assessing the gas injection location. Radial velocity, rotational temperature and translational temperature measurements are provided that can be used to validate future high-fidelity computational studies. The temperature measurements revealed rotational non-equilibrium potentially occurring in the flow. This work provides a methodology for characterizing arc-jet facilities, identifying and correcting sources of systematic error, and estimating the uncertainty associated with the quantitative measurements.

laser induced fluorescence↗

Characterization of the NASA Langley Arc Heated Scramjet Test Facility Using NO PLIF

The nitric oxide planar laser-induced fluorescence (NO PLIF) imaging was used to characterize the air flow of the NASA Langley Arc Heated Scramjet Test Facility (AHSTF) configured with a Mach 6 nozzle. The arc raises the enthalpy of the test gas in AHSTF, producing nitric oxide. Nitric oxide persists as the temperature drops through the nozzle into the test section. NO PLIF was used to qualitatively visualize the flowfield at different experimental conditions, measure the temperature of the gas flow exiting the facility nozzle, and visualize the wave structure downstream of the nozzle at different operating conditions. Uniformity and repeatability of the nozzle flow were assessed. Expansion and compression waves on the free-jet shear layer as the nozzle flow expands into the test section were visualized. The main purpose of these experiments was to assess the uniformity of the NO in the freestream gas for planned experiments, in which NO PLIF will be used for qualitative fuel-mole-fraction sensitive imaging. The shot-to-shot fluctuations in the PLIF signal, caused by variations in the overall laser intensity as well as NO concentration and temperature variations in the flow was 20-25% of the mean signal, as determined by taking the standard deviation of a set of images obtained at constant conditions and dividing by the mean. The fluctuations within individual images, caused by laser sheet spatial variations as well as NO concentration and temperature variations in the flow, were about 28% of the mean in images, determined by taking standard deviation within individual images, dividing by the mean in the same image and averaged over the set of images. Applying an averaged laser sheet intensity correction reduced the within-image intensity fluctuations to about 10% suggesting that the NO concentration is uniform to within 10%. There was no significant difference in flow uniformity between the low and high enthalpy settings. While not strictly quantitative, the temperature maps show qualitative agreement with the computations of the flow.

Kidd, F. Gray, III↗

Aerothermodynamic Measurements of Hypersonic Non-Equilibrium Flows

High enthalpy arc-jets are unique facilities particularly suited for producing complex flows in the aerospace field, such as the aerothermodynamics of a re-entry vehicle. Arc-jets are often used to evaluate important design factors that include heat shield materials and vehicle design. Characterization of these facilities is important, as studies often aim to match specific in-flight environments during experiments. Due to the complex environment produced by an arc-jet, with effects such as thermodynamic and chemical non-equilibrium occurring in the flow, characterization experiments are significantly more difficult than in conventional blow-down wind tunnels. The current work aims to characterize an arc-jet facility through spatially-resolved measurements of flow unsteadiness, temperature, and velocity. To achieve this goal, a non-intrusive imaging technique called “planar laser-induced fluorescence” was performed in the NASA Langley Hypersonic Materials Environmental Test System arc-jet facility. The experimental data was analysed to produce the quantitative measurements in multiple regions of the flow around a blunt body specimen. A three-temperature low fidelity numerical solver was created to simulate the flow in order to investigate thermal non-equilibrium effects occurring outside the imaging region in the arc-jet nozzle. Unsteadiness in the test section of the arc-jet was minimized by analyzing a subset of data assessing the gas injection configuration. Radial velocity, rotational temperature and translational temperature measurements are provided that can be used to validate future computational studies. The temperature measurements revealed rotational non-equilibrium occurring behind the bow-shock near the specimen surface. Computational results show the facility is capable of producing thermal non-equilibrium flow in the arc-jet nozzle. This work provides the first experimental and computational evidence of thermal trans-rotational non-equilibrium occurring in multiple regions of this arc-jet facility. Significant improvements to the methodology are also identified as recommendations for future arc-jet characterization studies.

Laser induced fluorescence↗

Design and performance of the Ames electric-arc shock tunnel

A high enthalpy shock tunnel using arc-heated helium as the driver gas was designed for gas dynamic research at total stream energies from 7,000 to 35,000 j/g. The arc driver was found to be a relatively efficient energy converter. Tailored shock Mach numbers from 11.5 to 14.6 in air were demonstrated. A nozzle calibration with a total stream enthalpy of 18,600 j/g of air gave test times of 1.5 to 2.0 m sec at flow Mach numbers from 16 to 24.

Reller, J. O., Jr.↗

Wall boundary equations with slip and catalysis for multicomponent, nonequilibrium gas flows

Boundary equations obtained for a low Reynolds number, high enthalpy gas flow in regions of velocity slip and temperature jump are presented. The formulation treats, through a first-order distribution function used to include multicomponent diffusion, a multicomponent gas mixture that may be in nonequilibrium with finite-rate catalytic recombination occurring on the wall. In the boundary equations, which are obtained for use in flow-field calculations applicable to low-density flow regimes, a simplified gas/wall interaction is assumed wherein individual atoms or molecules either reflect specularly off the wall or stick and are fully accommodated. Fluxes in terms of evaluated integrals over the distribution function and integrals necessary for determining fluxes are given.

Scott, C. D.↗

Decomposition of nitric oxide in a hot nitrogen stream to synthesize air for hypersonic wind tunnel combustion testing

A clean source of high enthalpy air was obtained from the exothermic decomposition of nitric oxide in the presence of strongly heated nitrogen. A nitric oxide jet was introduced into a confined coaxial nitrogen stream. Measurements were made of the extent of mixing and reaction. Experimental results are compared with one- and two-dimensional chemical kinetics computations. Both analyses predict much lower reactivity than was observed experimentally. Inlet nitrogen temperatures above 2400 K were sufficient to produce experimentally a completely reacted gas stream of synthetic air.

Zumdieck, J. F.↗

Helical screw expander evaluation project

A one MW helical rotary screw expander power system for electric power generation from geothermal brine was evaluated. The technology explored in the testing is simple, potentially very efficient, and ideally suited to wellhead installations in moderate to high enthalpy, liquid dominated field. A functional one MW geothermal electric power plant that featured a helical screw expander was produced and then tested with a demonstrated average performance of approximately 45% machine efficiency over a wide range of test conditions in noncondensing, operation on two-phase geothermal fluids. The Project also produced a computer equipped data system, an instrumentation and control van, and a 1000 kW variable load bank, all integrated into a test array designed for operation at a variety of remote test sites. Data are presented for the Utah testing and for the noncondensing phases of the testing in Mexico. Test time logged was 437 hours during the Utah tests and 1101 hours during the Mexico tests.

Mckay, R.↗

Analysis of flow dynamics through small diameter gas sampling systems

The removal of gas material through a capillary opening in a surface is analyzed. The gas, from which the sample is removed, is moving past the surface at supersonic velocities. A variety of possible conditions of temperature, pressure and composition are discussed in an effort to emulate conditions that might be found at the surface of a vehicle traversing the altitude range 100-50 km, or might exist at the surface of a model in the stream of a high enthalpy wind tunnel. Aspects discussed include: (1) the throughput of the capillary for conditions of different lengths and different L/a (length/radius) ratios; (2) the total throughput when the surface in question contains many hundreds of these capillaries; (3) the effect of the capillaries upon the composition of the analyzed gas; (4) the effect of the capillary or capillaries upon the gas stream itself; and (5) the implications of the calculations upon the possible implementation of this type of device as an inlet for a mass spectrometer to be developed for analyzing the upper atmosphere.

Brown, K. G.↗