Search NASA⌕ Search

SEARCH · Search NASA

Results for “high frequency instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The high-power helicon program at DIII-D: gearing up for first experiments

Helicon current drive, also called fast wave current drive in the lower hybrid range of frequencies, has long been regarded as a promising current drive tool for reactor grade plasmas. A newly installed MW-level system at DIII-D will be the first test of this technology in reactor-relevant plasmas, in the sense that full single-pass absorption is expected. A 30-module traveling wave antenna has been installed and optimized in-vessel in early 2020. The linear electromagnetic characteristics of the unloaded module array have been extensively tested both on the bench and in the vessel at instrumentation power levels. Excellent performance has been achieved, ~2% reflected power and ~1.5% dissipated power per module in air, in a 10 MHz band around 476 MHz. Stripline feeds on both ends of the antenna allow either co or counter current drive. The installation of a 1.2 MW klystron and associated high-power electronics was completed in Fall 2020. Commissioning of the antenna is ongoing. An important goal of this experiment is to validate the helicon current drive physics basis using an extensive set of new and upgraded diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EXPRES. I. HD 3651 as an Ideal RV Benchmark

The next generation of exoplanet-hunting spectrographs should deliver up to an order of magnitude improvement in radial velocity (RV) precision over the standard 1 m s{sup −1} state-of-the-art spectrographs. This advance is critical for enabling the detection of Earth-mass planets around Sun-like stars. New calibration techniques such as laser frequency combs and stabilized etalons ensure that the instrumental stability is well characterized. However, additional sources of error include stellar noise, undetected short-period planets, and telluric contamination. To understand and ultimately mitigate error sources, the contributing terms in the error budget must be isolated to the greatest extent possible. Here, we introduce a new high-cadence RV program, the Extreme Precision Spectrograph (EXPRES) 100 Earths Survey, which aims to identify rocky planets around bright, nearby G and K dwarfs. We also present a benchmark case: the 62 day orbit of a Saturn-mass planet orbiting the chromospherically quiet star, HD 3651. The combination of high eccentricity (0.6) and a moderately long orbital period ensures significant dynamical clearing of any inner planets. Our Keplerian model for this planetary orbit has a residual rms of 58 cm s{sup −1} over a ∼6 month time baseline. By eliminating significant contributors to the RV error budget, HD 3651 serves as a standard for evaluating the long-term precision of extreme precision RV programs.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermodynamic Profiling Through ASSIST Observations and TROPoe Retrievals

This report reviews the most relevant theoretical aspects of thermodynamic profiling techniques based on spectral observations from ASSIST-II infrared radiometers and TROPoe retrievals. The ASSIST+TROPoe system is a cutting-edge remote sensing technology deployed during the AWAKEN and WFIP3 field campaigns to estimate high-frequency profiles of temperature and humidity in the atmosphere. These profiles are highly valuable for characterizing atmospheric stratification, improving wind models, and understanding the impacts of wind plants on the climate. In this document, we discuss the operating principles of ASSIST, the physics of atmospheric infrared radiation, and the mathematical framework and capabilities of TROPoe. Sources of uncertainties in both the instrument and the retrieval method are also thoroughly addressed. This guide is designed to help users of ASSIST, TROPoe, and thermodynamic data in collecting, estimating, and applying thermodynamic profiles rigorously and scientifically.

17 WIND ENERGY↗

AmeriFlux US-GL1 Stannard Rock

This is the AmeriFlux version of the carbon flux data for the site US-GL1 Stannard Rock. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris↗

AmeriFlux FLUXNET-1F US-GL1 Stannard Rock

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-GL1 Stannard Rock. This is the FLUXNET version of the carbon flux data for the site US-GL1 Stannard Rock produced by applying the standard ONEFlux (1F) software. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris [Environment and Climate Change Cana↗

Spectral and temporal shaping of spectrally incoherent pulses in the infrared and ultraviolet

Laser–plasma instabilities (LPIs) hinder the interaction of high-energy laser pulses with targets. Simulations show that broadband spectrally incoherent pulses can mitigate these instabilities. Optimizing laser operation and target interaction requires controlling the properties of these optical pulses. We demonstrate closed-loop control of the spectral density and pulse shape of nanosecond spectrally incoherent pulses after optical parametric amplification in the infrared (∼1053 nm) and sum–frequency generation to the ultraviolet (∼351 nm) using spectral and temporal modulation in the fiber front end. The high versatility of the demonstrated approaches can support the generation of high-energy, spectrally incoherent pulses by future laser facilities for improved LPI mitigation.

47 OTHER INSTRUMENTATION↗

CROCUS Weather Data at Chicago State University Prairie Site

Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements. These measurements are collected at Chicago State University (CSU) at a prarie site on campus in Chicago, Illinois. Data is available in the netCDF data format, we encourage data users review documentation through Project Pythia to understand how to work with netCDF data https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html. The data is aggregated into daily frequency to make it easier to process multiple days, and compress the higher-resolution fields. Each file contains one day's worth of data (24 hours, starting at 0000 UTC). File naming convention includes the project (CROCUS), location (CSU), data level (raw, a1), date (year, month, day), and hour (0000).

54 ENVIRONMENTAL SCIENCES↗

CROCUS Weather Data at Argonne National Laboratory Prairie Site

Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements. These measurements are collected at the Argonne Testbed for Multiscale Observational Science (ATMOS), a prairie field site at Argonne National Laboratory in Lemont, Illinois. Data is available in the netCDF data format, we encourage data users review documentation through Project Pythia to understand how to work with netCDF data https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html. The data is aggregated into daily frequency to make it easier to process multiple days, and compress the higher-resolution fields. Each file contains one day's worth of data (24 hours, starting at 0000 UTC). File naming convention includes the project (CROCUS), location (atmos), data level (raw, a1), date (year, month, day), and hour (0000).

54 ENVIRONMENTAL SCIENCES↗

CROCUS Weather Data at University of Illinois - Chicago Tower

Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements. These measurements are collected at the University of Illinois in Chicago, Illinois, on the meteorological tower near the greenhouse on campus. Data is available in the netCDF data format, we encourage data users review documentation through Project Pythia to understand how to work with netCDF data https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html. File naming convention includes the project (CROCUS), location (UIC), data level (raw, a1), date (year, month, day), and hour (0000).

54 ENVIRONMENTAL SCIENCES↗

CCAT-prime Collaboration: Science Goals and Forecasts with Prime-Cam on the Fred Young Submillimeter Telescope

Abstract We present a detailed overview of the science goals and predictions for the Prime-Cam direct-detection camera–spectrometer being constructed by the CCAT-prime collaboration for dedicated use on the Fred Young Submillimeter Telescope (FYST). The FYST is a wide-field, 6 m aperture submillimeter telescope being built (first light in late 2023) by an international consortium of institutions led by Cornell University and sited at more than 5600 m on Cerro Chajnantor in northern Chile. Prime-Cam is one of two instruments planned for FYST and will provide unprecedented spectroscopic and broadband measurement capabilities to address important astrophysical questions ranging from Big Bang cosmology through reionization and the formation of the first galaxies to star formation within our own Milky Way. Prime-Cam on the FYST will have a mapping speed that is over 10 times greater than existing and near-term facilities for high-redshift science and broadband polarimetric imaging at frequencies above 300 GHz. We describe details of the science program enabled by this system and our preliminary survey strategies.

79 ASTRONOMY AND ASTROPHYSICS↗

Wireless Passive Ceramic Sensor for Far-Field Temperature Measurement at High Temperatures

A passive wireless high-temperature sensor for far-field applications was developed for stable temperature sensing up to 1000 °C. The goal is to leverage the properties of electroceramic materials, including adequate electrical conductivity, high-temperature resilience, and chemical stability in harsh environments. Initial sensors were fabricated using Ag for operation to 600 °C to achieve a baseline understanding of temperature sensing principles using patch antenna designs. Fabrication then followed with higher temperature sensors made from (In, Sn) O2 (ITO) for evaluation up to 1000 °C. A patch antenna was modeled in ANSYS HFSS to operate in a high-frequency region (2.5–3.5 GHz) within a 50 × 50 mm2 confined geometric area using characteristic material properties. The sensor was fabricated on Al2O3 using screen printing methods and then sintered at 700 °C for Ag and 1200 °C for ITO in an ambient atmosphere. Sensors were evaluated at 600 °C for Ag and 1000 °C for ITO and analyzed at set interrogating distances up to 0.75 m using ultra-wideband slot antennas to collect scattering parameters. The sensitivity (average change in resonant frequency with respect to temperature) from 50 to 1000 °C was between 22 and 62 kHz/°C which decreased as interrogating distances reached 0.75 m.

47 OTHER INSTRUMENTATION↗

Limited-angle computed tomography with deep image and physics priors

Computed tomography is a well-established x-ray imaging technique to reconstruct the three-dimensional structure of objects. It has been used extensively in a variety of fields, from diagnostic imaging to materials and biological sciences. One major challenge in some applications, such as in electron or x-ray tomography systems, is that the projections cannot be gathered over all the angles due to the sample holder setup or shape of the sample. This results in an ill-posed problem called the limited angle reconstruction problem. Typical image reconstruction in this setup leads to distortion and artifacts, thereby hindering a quantitative evaluation of the results. To address this challenge, we use a generative model to effectively constrain the solution of a physics-based approach. Our approach is self-training that can iteratively learn the nonlinear mapping from partial projections to the scanned object. Because our approach combines the data likelihood and image prior terms into a single deep network, it is computationally tractable and improves performance through an end-to-end training. We also complement our approach with total-variation regularization to handle high-frequency noise in reconstructions and implement a solver based on alternating direction method of multipliers. We present numerical results for various degrees of missing angle range and noise levels, which demonstrate the effectiveness of the proposed approach.

47 OTHER INSTRUMENTATION↗

Fast quantum interferometry at the nanometer and attosecond scales with energy-entangled photons

In classical optical interferometry, loss and background complicate achieving fast nanometer-resolution measurements with illumination at low light levels. Conversely, quantum two-photon interference is unaffected by loss and background, but nanometer-scale resolution is physically difficult to realize. As a solution, we enhance two-photon interference with highly nondegenerate energy entanglement featuring photon frequencies separated by 177 THz. We observe measurement resolution at the nanometer (attosecond) scale with only O(10 4 ) photon pairs, despite the presence of background and loss. Our nondestructive thickness measurement of a metallic thin film agrees with atomic force microscopy, which often achieves better resolution via destructive means. With contactless, nondestructive measurements in seconds or faster, our instrument enables metrological studies in optically challenging contexts where background, loss, or photosensitivity are factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dataset for Cruz-O'Byrne et al (2026): "Divergent biogeochemical responses in upland coastal forest soils to repeated flooding and shifts in water chemistry"

Hydrologic disturbances from accelerated sea-level rise and the increasing frequency and intensity of storms and tidal flooding are altering biogeochemical processes in upland coastal forests, transforming these ecosystems into wetlands. However, the initial effects of flooding on belowground biogeochemistry and the mechanisms driving greenhouse gas dynamics and soil organic matter stability during the early stages of this transition remain poorly understood. This dataset presents the results of a mesocosm experiment conducted in a controlled, highly instrumented laboratory environment, in which freshwater and brackish water pulses were applied to intact soil monoliths from a temperate upland coastal forest to examine how floodwater chemistry influences soil biogeochemistry and organo-mineral interactions. All data files are plain-text CSV (comma-separated value), and no special software is required to read them. Details about the content of each file are available in the document “Dataset_readme”. The dataset consists of the following data: • rcruzobyrne_moisture: Soil volumetric water content (VWC) • rcruzobyrne_GHG: Headspace greenhouse gas (GHG) concentration and fluxes • rcruzobyrne_methane_isotopes: Headspace methane isotope signature • rcruzobyrne_porewater: Porewater chemistry • rcruzobyrne_CDOM: Porewater colored dissolved organic matter (CDOM) • rcruzobyrne_FTIR: Soil Fourier-transform infrared (FTIR) spectroscopy Details of the experimental setup, data collection, and data analysis are provided in the manuscript by Cruz-O’Byrne et al (2026) Divergent biogeochemical responses in upland coastal forest soils to repeated flooding and shifts in water chemistry. Biogeochemistry. https://doi.org/10.1007/s10533-026-01340-0

EARTH SCIENCE > ATMOSPHERE > GREENHOUSE GAS↗

A Square Pulse Thermoreflectance Technique for the Measurement of Thermal Properties

We report on a laser-based square pulse thermoreflectance (SPTR) technique for the measurement of thermal properties for a wide range of materials. SPTR adopts the pump-probe thermoreflectance principle to monitor the evolution of local temperature after square pulse excitation. The technique features a compact setup, high spatial resolution, and fast data collection. By comparing the acquired SPTR signals with a continuum heat transfer model, material thermal properties can be obtained. Taking advantage of various spot sizes and modulation frequencies, SPTR can measure both the thermal diffusivity and thermal conductivity of poorly to moderately conductive materials and the thermal conductivity of conductive materials with satisfactory accuracy, with potential to be applied to more conductive materials. The technique was validated on three materials: fused silica, single crystal CaF2 and single crystal nickel (with conductivities ranging from 1 W·m -1 ·K -1 to 100 W·m -1 ·K -1 ) with typical measurement errors of 5 % to 20 %. The leading sources of error have been identified by Monte Carlo simulations, and the primary limitations of SPTR are discussed. The compact, fiberized platform we describe here will allow instruments based on this methodology to be deployed in complex, multi-analytical environments for the type of high-throughput correlative analyses that are key to materials design and discovery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

We report for the first time, a digital Mirror Langmuir Probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I–V characteristics with a high frequency, high power digital amplifier, and field-programmable gate array controller. Measurements taken by the MLP were validated by a low speed I–V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field($\widetilde{f}$ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it toward a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution, such as edge plasma, scrape-off layer, and divertor probes.

47 OTHER INSTRUMENTATION↗

Concept for an irradiation experiment to test a laser-induced breakdown spectroscopy off-gas sensor for molten salt systems

This paper focuses on laser-induced breakdown spectroscopy (LIBS) as an off-gas sensor and details a conceptual irradiation experiment to evaluate its performance in an environment that is more realistic of an operational molten salt reactor (MSR). MSRs are a promising advanced nuclear design that use high-temperature liquid salts as the coolant, fuel, or a combination of both. They will generate and subsequently evolve fission products into the reactor headspace during operation. These evolved fission products will necessitate an online off-gas system to treat the reactor cover gas before recycling it to the core. Such a system, especially during the early deployment phase, will benefit from online sensors to inform operators of the treatment system’s performance. Optical spectroscopy is well-suited to fit this task as it can be remotely deployed using fiber-optics and can detect most species at high frequencies. LIBS can detect nearly every element on the Periodic Table, stable or radioactive, making it an ideal candidate. The provided conceptual experiment discusses the facility requirements, salt capsule design, and detailed testing campaigns with corresponding simulated LIBS spectra.

47 OTHER INSTRUMENTATION↗

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗