Search NASA⌕ Search

SEARCH · Search NASA

Results for “high precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Estimation and filtering for high-precision GPS positioning applications

Estimation of GPS satellite orbits and other parameters for high-accuracy geodetic and tracking applications is carried out with a multi-satellite batch sequential pseudo-epoch state process noise filter. Both square-root information filtering and UD factorized covariance filtering and smoothing formulations are implemented in the software to enhance numerical stability. The filtering algorithms have been arranged to take advantage of sparse matrices and other characteristics of the GPS measurement scenarios. The filter includes unique error evaluation capabilities to assess effects from mismodeling. Process noise plays a key role in the orbit determination for stochastic behavior of transmitter/receiver clocks, atmospheric-induced delay fluctuations, and unmodeled spacecraft accelerations. Present GPS orbit accuracy is better than 1 m, with ground baselines determined simultaneously to relative accuracy of 1.5 parts in 10 to the 8th over several thousand km distance.

Lichten, Stephen M.↗

High Precision Laser Range Sensor

The present invention is an improved distance measuring interferometer that includes high speed phase modulators and additional phase meters to generate and analyze multiple heterodyne signal pairs with distinct frequencies. Modulation sidebands with large frequency separation are generated by the high speed electro-optic phase modulators, requiring only a single frequency stable laser source and eliminating the need for a fist laser to be tuned or stabilized relative to a second laser. The combination of signals produced by the modulated sidebands is separated and processed to give the target distance. The resulting metrology apparatus enables a sensor with submicron accuracy or better over a multi- kilometer ambiguity range.

Dubovitsky, Serge↗

Application of high precision two-way S-band ranging to the navigation of the Galileo Earth encounters

The application of high-accuracy S/S-band (2.1 GHz uplink/2.3 GHz downlink) ranging to orbit determination with relatively short data arcs is investigated for the approach phase of each of the Galileo spacecraft's two Earth encounters (8 December 1990 and 8 December 1992). Analysis of S-band ranging data from Galileo indicated that under favorable signal levels, meter-level precision was attainable. It is shown that ranginging data of sufficient accuracy, when acquired from multiple stations, can sense the geocentric angular position of a distant spacecraft. Explicit modeling of ranging bias parameters for each station pass is used to largely remove systematic ground system calibration errors and transmission media effects from the Galileo range measurements, which would otherwise corrupt the angle finding capabilities of the data. The accuracy achieved using the precision range filtering strategy proved markedly better when compared to post-flyby reconstructions than did solutions utilizing a traditional Doppler/range filter strategy. In addition, the navigation accuracy achieved with precision ranging was comparable to that obtained using delta-Differenced One-Way Range, an interferometric measurement of spacecraft angular position relative to a natural radio source, which was also used operationally.

Pollmeier, Vincent M.↗

High precision fundamental physics experiments using compact spin-transparent storage rings of low energy polarized electron beams

We present a new design of highly specialized small storage rings for low energy polarized electron beams. The new design is based on the transparent spin methodology that cancels the spin precession due to the magnetic dipole moment at any energy while allowing for spin precession induced by the fundamental physics of interest to accumulate. The buildup of the vertical component of beam polarization can be measured using standard Mott polarimetry that is optimal at low electron energy. These rings can be used to measure the permanent electric dipole moment of the electron, relevant to CP violation and matter-antimatter asymmetry in the universe, and to search for dark energy and ultra-light dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Precision Relative Position Sensing System for Formation Flying Spacecraft

Three candidate sensors under development - Longitudinal Sensing: Precision Laser Ranger (PLR) - Periodic laser pulses are reflected off a distant target. - Heterodyne analysis of returning pulses enables high resolution ranging. - Transverse Sensing = Transverse Alignment Sensor (TAS) - Laser beam is focused onto distant laser position sensor. - Analog sensor provides coordinates of spot on sensor. - 3D PLR: Alternative approach to transverse sensing: - Combine PLR with 3D target covered with retroreflective material. - 6 degree of freedom sensing using PLR. - May eliminate need for TAS.

Anne-Marie Novo-Gradac↗

High precision electric gate for time-of-flight ion mass spectrometers

A time-of-flight mass spectrometer having a chamber with electrodes to generate an electric field in the chamber and electric gating for allowing ions with a predetermined mass and velocity into the electric field. The design uses a row of very thin parallel aligned wires that are pulsed in sequence so the ion can pass through the gap of two parallel plates, which are biased to prevent passage of the ion. This design by itself can provide a high mass resolution capability and a very precise start pulse for an ion mass spectrometer. Furthermore, the ion will only pass through the chamber if it is within a wire diameter of the first wire when it is pulsed and has the right speed so it is near all other wires when they are pulsed.

Sittler, Edward C.↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A High Precision Measurement of the Proton Charge Radius at JLab

The elastic electron-proton (e-p) scattering and the spectroscopy of hydrogen atoms are the two traditional methods to determine the proton charge radius (r p ). In 2010, a new method using muonic hydrogen (µH) 1 spectroscopy reported a r p result that was nearly ten times more precise but significantly smaller than the values from the compilation of all previous r p measurements. This discrepancy is often referred to as the "proton charge radius puzzle". In order to investigate the puzzle, the PRad experiment (E12-11-106) was first proposed in 2011 and performed in 2016 in Hall B at the Thomas Jefferson National Accelerator Facility, with both 1.1 and 2.2 GeV electron beams. The experiment measured the e-p elastic scattering cross sections in an unprecedented low values of momentum transfer squared region (Q 2 = 2.1× 10 -4 -0.06 (GeV/c) 2 ), with a sub-percent precision. The PRad experiment utilized a calorimetric method that was magnetic-spectrometer-free. Its detector setup included a large acceptance and high resolution calorimeter (HyCal), and two large-area, high spatial-resolution Gas Electron Multiplier (GEM) detectors. To have a better control over the systematic uncertainties, the absolute e-p elastic scattering cross section was normalized to that of the well-known Møller scattering process, which was measured simultaneously during the experiment. For each beam energy, all data with different Q 2 were collected simultaneously with the same detector setup, therefore sharing the same integrated luminosity. The windowless H 2 gas-flow target utilized in the experiment largely removed a typical background source, the target cell windows. The proton charge radius was determined as r p = 0.831±0.007 stat. ±0.012 p fm, which is smaller than the average r p from previous e-p elastic scattering experiments, but in agreement with the µH spectroscopic results within the experimental uncertainties.

Source record↗

High-precision Measurement of the 16 O($n, n'γ$) Cross Section using $γ$-ray Detection in Liquid Scintillators with H 2 O and BeO Targets

The 16 O($n, n'γ$) reaction was measured at the Los Alamos Neutron Science Center white neutron source using γ-ray detection in liquid scintillators present in the upper hemisphere of the Correlated Gamma-Neutron Array for sCattering (CoGNAC). Separate measurements of this reaction were performed using H 2 O and BeO targets in successive years. The unique high energies of γ rays emitted from the 16 O($n, n'γ$) reaction facilitated a clean selection of this reaction from threshold to 9.8 MeV incident neutron energy without the need for precise measurements of the γ-ray energy or the scattered neutrons. The precise time resolution of the liquid scintillator detectors was then exploited to obtain high-resolution incident neutron energy measurements, and good agreement was obtained between the H 2 O and BeO results reported here. The dominant literature data sets for this reaction have systematic differences between them, but the present results improve upon the neutron energy resolution of earlier measurements and show important discrepancies in recent data. Finally, tentative data are also shown up to 20 MeV incident neutron energy but are potentially subject to improved understanding of the relative γ-ray and α decay branches from 16 O excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Moon Mineral Mapper (M3): A High Uniformity and High Precision Science Imaging Spectrometer in the Solar Reflected Spectrum

The Moon Mineralogy Mapper was selected as a NASA Discovery Mission of Opportunity in February 2005. At the core of this mission is an imaging spectrometer instrument with high spectral-spatial uniformity and high signal-to-noise ratio for the expected illumination conditions. The spectral range of the Moon Mineralogy Mapper is from 430 to 3000 nm with 10 nm spectral sampling. The radiometric range is from 0 to maximum expected radiance with 14 bit sampling. The spatial swath is nominally 40 Ian with 70 m spatial sampling. The Moon Mineralogy Mapper has both a global and target mode of data acquisition. In global spectral and spatial resolution full coverage of the Moon will be acquired. Target mode will be used to examine selected areas a full spectral and spatial resolution. The science objectives and mission and instrument characteristics are presented.

mapping↗

The Galileo attitude and articulation control system - A radiation-hard, high precision, state-of-the-art control system

The Galileo mission and spacecraft, consisting of a Jupiter-orbiter and an atmospheric entry probe, are discussed. Components will include: magnetometers and plasma-wave antennas on a boom, high-gain antenna, probe vehicle, two different bus electronics packages, and a radioisotope thermoelectric generator. Instruments, investigators and objectives are tabulated for both probe science and orbiter science investigations. Requirements in the design of the attitude and articulation control system are very stringent because of the complex dynamics, flexible body effects, the need for autonomy, and the severe radiation environment in the Jupiter nighborhood. Galileo was intended to be ready for launch via Space Shuttle in May of 1986.

Stephenson, R. Rhoads↗

A Cavity-Enhanced UV Absorption Instrument for High-Precision, Fast-Time-Response Ozone Measurements

The NASA Rapid Ozone Experiment (ROZE) is a broadbandcavity-enhanced UV absorption instrument for the detection of in situozone (O3).ROZE uses an incoherent LED light source coupled to a high-finesse optical cavity to achieve an effective pathlength of ~104 m. Due to its high-sensitivity and smalloptical cell volume, ROZE demonstratesa 1𝜎precision of 80 pptv (0.1 s) and 31 pptv (1 s), as well as an 𝑒-fold timeresponseof 50 ms. ROZE can be operated in a range of field environments, including low-and high-altitude research aircraft,and is particularly suited toO3vertical flux measurements usingthe eddy covariance technique.ROZE was successfully integrated aboard the NASA DC-8 aircraft during July–September2019and validated against a well-established chemiluminescence measurement of O3.Aflight within the marine boundary layer also demonstrated flux measurement capabilities, and we observeda mean O3deposition velocityof 0.029 ± 0.005 cm s–1to the ocean surface.The performance characteristics detailed below make ROZE a robust, versatile instrument for fieldmeasurements of O3.

Rapid Ozone Experiment (ROZE)↗

High-precision scale setting with the Ω-baryon mass and gradient flow

The gradient-flow scale 𝑤 0 in lattice QCD is determined using the mass of the Ω − baryon to set the physical scale. Nine ensembles using the highly improved staggered quark (HISQ) action with lattice spacings of 0.15 fm down to 0.04 fm are used, seven of which have nearly physical light-quark masses. Electromagnetic corrections to the Ω − mass are defined in order to compute a pure-QCD Ω mass. The final result is 𝑤 0 = 0.17187⁢(68) fm, corresponding to a relative uncertainty of 0.40% and a central value in good agreement with previous calculations in the literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Precision Determination of Oxygen $K_{α}$ Transition Energy Excludes Incongruent Motion of Interstellar Oxygen

We demonstrate a widely applicable technique to absolutely calibrate the energy scale of x-ray spectra with experimentally well-known and accurately calculable transitions of highly charged ions, allowing us to measure the K-shell Rydberg spectrum of molecular O 2 with 8 meV uncertainty. Here, we reveal a systematic ~450 meV shift from previous literature values, and settle an extraordinary discrepancy between astrophysical and laboratory measurements of neutral atomic oxygen, the latter being calibrated against the aforementioned O 2 literature values. Because of the widespread use of such, now deprecated, references, our method impacts on many branches of x-ray absorption spectroscopy. Moreover, it potentially reduces absolute uncertainties there to below the meV level.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electrical Resistivity Tomography based monitoring of stress perturbations to optimize placement of high-precision strain meters

The Center for Understanding Subsurface Signals and Permeability is a new U.S. Department of Energy Earthshot Center focused on understanding and predicting the long-term evolution of permeability in enhanced geothermal systems. The center will use a highly instrumented testbed within the Sanford Underground Research Facility to conduct field scale experiments that elucidate and test capabilities to simulate geochemical-geomechanical interactions and permeability evolution. Here we demonstrate initial developments using previously collected electrical resistivity tomography (ERT) monitoring data with high-performance multi-physics modelling advancements to inform the optimal location of two new monitoring boreholes. Specifically, ERT monitoring data collected during shear stimulation testing shows marked responses to changes in stress during borehole pressurization. We demonstrate how the same response is being simulated, ultimately to train a machine-learning algorithm to estimate rock properties and enable enhanced prediction of stress and strain responses anticipated during future testing campaigns.

Stress, EGS, CUSSP, 3D Electrical Imaging↗

High-Precision Determination of Oxygen-Kalpha Transition Energy Excludes Incongruent Motion of Interstellar Oxygen

We demonstrate a widely applicable technique to absolutely calibrate the energy scale of x-ray spectra with experimentally well-known and accurately calculable transitions of highly charged ions, allowing us to measure the K-shell Rydberg spectrum of molecular O2 with 8 meV-uncertainty. We reveal a systematic ~450meV shift from previous literature values, and settle an extraordinary discrepancy between astrophysical and laboratory measurements of neutral atomic oxygen, the latter being calibrated against the aforementioned O2 literature values. Because of the widespread use of such, now deprecated, references, our method impacts on many branches of x-ray absorption spectroscopy. Moreover, it potentially reduces absolute uncertainties there to below the meV level.

M A Leutenegger↗