Search NASA⌕ Search

SEARCH · Search NASA

Results for “high throughput sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

In situ synchrotron X-ray imaging and mechanical properties characterization of additively manufactured high-entropy alloy composites

Laser beam directed energy deposition has become an increasingly popular advanced manufacturing technique for materials discovery as a result of the in situ alloying capability. In this study, we leverage an additive manufacturing enabled high throughput materials discovery approach to explore the composition space of a graded W x (CoCrFeMnNi) 100–x sample spanning 0 ≤ x ≤ 21 at%. In addition to microstructural and mechanical characterization, synchrotron high speed x-ray computer aided tomography was conducted on a W 20 (CoCrFeMnNi) 80 composition to visualize melting dynamics, powder-laser interactions, and remelting effects of previously consolidated material. Results reveal the formation of the Fe 7 W 6 intermetallic phase at W concentrations> 6 at%, despite the high configurational entropy. Unincorporated W particles also occurred at W concentrations> 10 at% accompanied by a dissolution band of Fe 7 W 6 at the W/matrix interface and hardness values greater than 400 HV. In this work, the primary strengthening mechanism is attributed to the reinforcement of the Fe 7 W 6 and W phases as a metal matrix composite. The in situ high speed x-ray imaging during remelting showed that an additional laser pass did not promote further mixing of the Fe 7 W 6 or W phases suggesting that, despite the dissolution of the W into the Fe 7 W 6 phase being thermodynamically favored, it is kinetically limited by the thickness/diffusivity of the intermetallic phase, and the rapid solidification of the laser-based process.

36 MATERIALS SCIENCE↗

Heterostructural interface engineering for ultrawide-gap nitrides from first principles: Ta C / Al N and Ta C / Ga N rocksalt-wurtzite interfaces

Epitaxial lattice matching is an important condition for the formation of coherent interfaces with low defect densities. However, lattice-matched substrates with the same crystal structure as the active layer are often not available, suggesting opportunities for utilizing heterostructural interfaces. For example, at high Al contents that are interesting for ultrawide-gap applications in power electronics, Al x ⁢Ga 1-x ⁢N semiconductor alloys in the (0001) orientation of the wurtzite (wz) structure become lattice-matched to (111)-oriented rocksalt (rs) Ta⁢C substrates. To predict the expected interface atomic structures under different synthesis conditions, we perform high-throughput density-functional-theory calculations, using an algorithm for systematic sampling of the possible stacking sequences of the atomic layers on the in-plane hexagonal lattice. The approach considers octahedral, tetrahedral, and prismatic coordination motifs, and is generally applicable for the modeling of commensurate rs/wz heterostructural interfaces. Our results provide guidance for synthesis control of substrate-film bonding and the polarity of ultrawide-gap Al x⁢ Ga 1-x⁢ N alloys on Ta⁢C substrates.

36 MATERIALS SCIENCE↗

Comparing Transcriptomic Points of Departure to Apical Effect Concentrations For Larval Fathead Minnow Exposed to Chemicals with Four Different Modes Of Action

It is postulated that below a transcriptomic-based point of departure, adverse effects are unlikely to occur, thereby providing a chemical concentration to use in screening level hazard assessment. The present study extends previous work describing a high-throughput fathead minnow assay that can provide full transcriptomic data after exposure to a test chemical. One-day post-hatch fathead minnows were exposed to ten concentrations of three representatives of four chemical modes of action: organophosphates, ecdysone receptor agonists, plant photosystem II inhibitors, and estrogen receptor agonists for 24 h. Concentration response modeling was performed on whole body gene expression data from each exposure, using measured chemical concentrations when available. Transcriptomic points of departure in larval fathead minnow were lower than apical effect concentrations across fish species but not always lower than toxic effect concentrations in other aquatic taxa like crustaceans and insects. The point of departure was highly dependent on measured chemical concentration which were often lower than the nominal concentration. Differentially expressed genes between chemicals within modes of action were compared and often showed statistically significant overlap. In addition, reproducibility between identical exposures using a positive control chemical (CuSO 4 ) and variability associated with the transcriptomic point of departure using in silico sampling were considered. Results extend a transcriptomic-compatible fathead minnow high-throughput assay for possible use in ecological hazard screening.

59 BASIC BIOLOGICAL SCIENCES↗

A Methodology for determining optimal milling parameters for low-taper microtensile sample production

Femtosecond lasers are beginning to see an increase in interest for industrial and high throughput microsample milling applications. Despite this, much of the literature regarding removal rate studies for ultrashort pulse laser milling continues to focus on single-pulse or similar experiments that have a very small time on target. The material volume removal rates of femtosecond milling can vary wildly depending on parameters like laser scan speed, hatch spacing, z-axis step size, and pulses on the material. Currently, there is no established methodology for determining the optimal values of these parameters for micromilling applications. This methodology was developed in this study. The methodology consists of a pulse study, a repeat study, and a z-step study that will return the milling parameters that resulted in the largest volume removal rate for the laser used for this research. The methodology was created for the laser system used in this study, and was tested on 316 Stainless Steel, but was developed in such a way that it may be adapted to any material, and with some tweaking of variables might be used in other laser systems. The laser system used in this study utilizes a novel positioning stage that introduces 6 degrees of freedom to the translation of laser samples, being able to tilt and move in all three axes. Using both the developed methodology and the unique capabilities of the laser microtensile samples were produced with taper angles of <1° in 316 Stainless Steel.

Barker, Zachary Wayne↗

High-Throughput Microfluidic Electroporation (HTME): A Scalable, 384-Well Platform for Multiplexed Cell Engineering

Electroporation-mediated gene delivery is a cornerstone of synthetic biology, offering several advantages over other methods: higher efficiencies, broader applicability, and simpler sample preparation. Yet, electroporation protocols are often challenging to integrate into highly multiplexed workflows, owing to limitations in their scalability and tunability. These challenges ultimately increase the time and cost per transformation. As a result, rapidly screening genetic libraries, exploring combinatorial designs, or optimizing electroporation parameters requires extensive iterations, consuming large quantities of expensive custom-made DNA and cell lines or primary cells. To address these limitations, we have developed a High-Throughput Microfluidic Electroporation (HTME) platform that includes a 384-well electroporation plate (E-Plate) and control electronics capable of rapidly electroporating all wells in under a minute with individual control of each well. Fabricated using scalable and cost-effective printed-circuit-board (PCB) technology, the E-Plate significantly reduces consumable costs and reagent consumption by operating on nano to microliter volumes. Furthermore, individually addressable wells facilitate rapid exploration of large sets of experimental conditions to optimize electroporation for different cell types and plasmid concentrations/types. Use of the standard 384-well footprint makes the platform easily integrable into automated workflows, thereby enabling end-to-end automation. We demonstrate transformation of E. coli with pUC19 to validate the HTME's core functionality, achieving at least a single colony forming unit in more than 99% of wells and confirming the platform's ability to rapidly perform hundreds of electroporations with customizable conditions. This work highlights the HTME's potential to significantly accelerate synthetic biology Design-Build-Test-Learn (DBTL) cycles by mitigating the transformation/transfection bottleneck.

Gaillard, William R↗

Label-Free Profiling of up to 200 Single-Cell Proteomes per Day Using a Dual-Column Nanoflow Liquid Chromatography Platform

Single-cell proteomics (SCP) has great potential to advance biomedical research and personalized medicine. The sensitivity of such measurements increases with low-flow separations (<100 nL/min) due to improved ionization efficiency, but the time required for sample loading, column washing, and regeneration in these systems can lead to low measurement throughput and inefficient utilization of the mass spectrometer. Herein, we developed a two-column liquid chromatography (LC) system that dramatically increases the throughput of label-free SCP using two parallel subsystems to multiplex sample loading, online desalting, analysis, and column regeneration. The integration of MS1-based feature matching increased proteome coverage when short LC gradients were used. The high-throughput LC system was reproducible between the columns, with a 4% difference in median peptide abundance and a median CV of 18% across 100 replicate analyses of a single-cell-sized peptide standard. An average of 621, 774, 952, and 1622 protein groups were identified with total analysis times of 7, 10, 15, and 30 min, corresponding to a measurement throughput of 206, 144, 96, and 48 samples per day, respectively. When applied to single HeLa cells, we identified nearly 1000 protein groups per cell using 30 min cycles and 660 protein groups per cell for 15 min cycles. Finally, we explored the possibility of measuring cancer therapeutic targets with a pilot study comparing the K562 and Jurkat leukemia cell lines. This work demonstrates the feasibility of high-throughput label-free single-cell proteomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Throughput Discovery Illuminates Design Principles and Limits for Long-Lived Charged Species in Organic Electrolytes

The chemical stability of charged molecules in all-organic redox flow batteries (RFBs) is required for the prolonged operation of these devices. Molecular engineering and electrolyte optimization are used to mitigate parasitic reactions and extend the lifetimes of the charge carriers. However, how much can structural variation extend the lifetime? To probe this query, we designed a high-throughput kinetic study of the radical cation of N-methylphenothiazinium, guided by statistical sampling and learning algorithms. Using Argonne’s autonomous discovery facility, we conducted over 6,000 kinetic experiments with robotic sample preparation, parallel kinetic measurements, and machine learning inputs, testing 188 solvent molecules selected from a space of over 540 candidates from 11 chemical classes. Algorithmic selections guided us to stable solvent candidates, which were further tested in high concentration with and without supporting electrolyte. Our findings reveal the inherent difficulty of exceeding the current state of the art through solvent variation. The desired stability is statistically rare and poorly predictable. Among the many tested, only three solvents significantly outperformed our baseline, acetonitrile─and none by more than a factor of 3─suggesting a general challenge in achieving the necessary techno-economic targets. Furthermore, we suggest that self-discharge through solvent homolysis is the cause of the observed limitations. Several structural motifs contribute to >1,000 h half-life stability including molecular simplicity, symmetry, oxidation complement, and strategic fluorination. Importantly, this workflow establishes effective assays for diagnosing and predicting oxidative stress for highly stable liquid electrolytes in all batteries.

Batteries↗

High-throughput oxidation screening and down-selection of refractory high entropy alloys in the Al-Cr-Mo-Nb-Ta-Ti system

Rapid experimentation and characterization are ever-present needs in the discovery of high entropy alloys. High entropy alloy systems are difficult to survey with systematic composition sweeps using traditional synthesis methods. The number of distinct compositions in even a four-element system is experimentally intractable. Exploration of these, and higher-element systems, necessitates thermodynamic prediction coupled with an automated sample creation method and a rapid screening methodology to effectively down-select alloys with targeted properties. As a result, a high-throughput method for evaluating the oxidation performance of refractory high entropy alloys was developed and tested. The six-element system of aluminum, chromium, molybdenum, niobium, tantalum, and titanium was evaluated for single phase stability and short-duration oxidation resistance. Target compositions were initially determined via thermodynamic predictions of single-phase stability across a wide temperature range. A twenty-five-sample build plate was produced using directed energy deposition additive manufacturing. After fabrication, the twenty-five 1 cm 3 samples were heat treated and characterized for composition and phase identification. The build plate was exposed to a high temperature oxidizing environment at 1000 °C for three hours. After oxidation, the composition, morphology, and chemistry of the oxides formed were characterized. Of the twenty-five samples produced, nine exhibited a favorable oxidation response, from which a single-phase BCC alloy at a composition of Al 13 Cr 7 Mo 19 Nb 18 Ta 26 Ti 17 was identified as the alloy with the most protective oxidation coating with a thin, adherent oxide scale. Finally, the complete experimental down-selection—from machine setup to final alloy identification—required approximately 45 labor hours, demonstrating a rapid validation for alloy discovery.

Additive manufacturing↗

A Compact X-Ray System for Support of High Throughput Crystallography

Standard x-ray systems for crystallography rely on massive generators coupled with optics that guide X-ray beams onto the crystal sample. Optics for single-crystal diffractometry include total reflection mirrors, polycapillary optics or graded multilayer monochromators. The benefit of using polycapillary optic is that it can collect x-rays over tile greatest solid angle, and thus most efficiently, utilize the greatest portion of X-rays emitted from the Source, The x-ray generator has to have a small anode spot, and thus its size and power requirements can be substantially reduced We present the design and results from the first high flux x-ray system for crystallography that combine's a microfocus X-ray generator (40microns FWHM Spot size at a power of 45 W) and a collimating, polycapillary optic. Diffraction data collected from small test crystals with cell dimensions up to 160A (lysozyme and thaumatin) are of high quality. For example, diffraction data collected from a lysozyme crystal at RT yielded R=5.0% for data extending to 1.70A. We compare these results with measurements taken from standard crystallographic systems. Our current microfocus X-ray diffraction system is attractive for supporting crystal growth research in the standard crystallography laboratory as well as in remote, automated crystal growth laboratory. Its small volume, light-weight, and low power requirements are sufficient to have it installed in unique environments, i.e.. on-board International Space Station.

Ciszak, Ewa↗

Spatially Resolved Raman Spectroscopic Investigation of Uranyl Fluoride: A Case Study in the Importance of Instrument Optimization

Raman spectroscopy is an emerging technique for rapid and nondestructive analysis of nuclear materials for forensic and nonproliferation applications as it is a powerful tool for distinguishing multiple chemical forms of materials with similar stoichiometries. Recent developments in spectroscopic software have enabled rapid data collection with high-speed Raman spectroscopic mapping capabilities. However, some uranium-rich materials are susceptible to degradation in humid air and/or laser-induced phase transformations. To mitigate environmental or measurement-related sample degradation of potential samples of interest, we have taken a systematic approach to define optimized data collection parameters for high-throughput measurements of uranyl fluoride (UO 2 F 2 ), which is an important intermediate material in the nuclear fuel cycle. First, we systematically describe the influence of optical magnification (5× to 100×), laser power, and exposure time on obtained signal for identical particles of UO 2 F 2 and find that at low laser power and exposure times, comparable signal is obtained regardless of optical magnification. Second, we ensure sample integrity during data collection, and third, collect spectroscopic maps that employ optimized parameters to reduce the time required to obtain spatially resolved spectroscopic information. Reductions of 90% and 99% in measurement times are discussed as they relate to differences in resolving spectroscopic features of particles in identical mapping areas. Finally, during this work, we found that additional data processing options were needed and thus developed a customized Python script for importing, processing, analyzing, and visualizing Raman spectroscopic map data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VIPIR: A High-Throughput Drop-Weight Impact Instrument for Imaging the Initiation and Propagation of Reactions in Energetic Materials

Characterizing the handling safety and sensitivity of explosives has been a challenging area of study for over 60 years. Historically one of the most accessible and widely utilized experiments has been the drop-weight impact test, which involves dropping a weight on a small sample sandwiched between two anvils. Because this experiment generally only utilizes sound thresholds to determine whether or not a sample reacted, the physical and chemical properties governing sensitivity remain convolved. Better understanding of chemical and material characteristics is needed to give the chemistry and engineering communities a predictive tool to determine the handling sensitivity of explosives prior to pursuing expensive and potentially hazardous synthesis and formulation operations. Here, we are developing a high throughput drop tower instrument capable of imaging the deformation and flow of energetic materials during impact and the resulting thermal ignition and propagation events. This instrument is based on previous designs but has been modified for higher throughput and tailorable modifications in the future. Herein, we present key design features that enable high-speed visible and thermal imaging of explosive initiation by sub-shock impacts, as well as preliminary results in which ignition sites were observed in an erythritol tetranitrate sample.

47 OTHER INSTRUMENTATION↗

Grafted nickel-promoter catalysts for dry reforming of methane identified through high-throughput experimentation

High-throughput synthesis of a series of monometallic and bimetallic catalysts (45 bimetallic and 50 monometallic samples) consisting of nickel and one of nine different metal promoters (B, Co, Cu, Fe, Mg, Mn, Sn, V and Zn) supported on one of six different metal oxides alumina, ceria, magnesia, silica and titania) is carried out via organometallic grafting using a robotic platform. The catalysts are evaluated for their activity and selectivity for the dry reforming of methane at a feed ratio of CH 4 :CO 2 of 1 at 650–800 °C in a parallel flow reactor system. The type of oxide support prevails over the type of additive for both catalyst activity and stability. On Al 2 O 3 and MgO, Fe was found to be the best promoter; on SiO 2 , Cu is the best promoter at 700 °C and higher, while on TiO 2 , Mn is found to enhance the conversion at 800 °C. On CeO 2 , all additives except Fe have beneficial effects. Twenty-five catalysts show > 90% methane conversion with ten catalysts showing > 95% conversion at 800 °C with the H 2 :CO ratios ranging from 0.8 to 1.2. Amongst the ten highest performers, NiFe/Al 2 O 3 and NiFe/MgO are more active than Ni/Al 2 O 3 and Ni/MgO, respectively and were stable over a period of 25 h at 800 °C. Characterization on the as-prepared samples reveals highly dispersed phase, while after reduction in H 2 , highly dispersed and reduced nickel particles up to 10 nm are formed. The particles do not increase in size under dry reforming reaction conditions at 800 °C. An increased hydrogen consumption observed during H 2 -TPR of the nickel particles is positively correlated with methane conversion for Al 2 O 3 -based catalysts. The resistance to deactivation by coking and variation in coke structure are investigated by spectroscopic and microscopic methods to identify the relationship between metal promoters, alloy formation, and type of surface carbon deposits. Carbon whiskers were observed on the ten selected spent samples and are preferentially deposited on Ni rather than on the promoters. Carbon nanotube formation and metal particle removal from support were not observed to cause deactivation while amorphous carbon formation was clearly linked to catalyst deactivation, as amorphous carbon could encapsulate nickel, either on the support or at the end of the carbon nanotube. Furthermore, the organometallic grafting technique is an efficient and suitable technique for synthesizing highly dispersed and homogeneous phases which lead to high conversion and high durability for dry reforming of methane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine Learning Thermodynamics And Kinetics of Defects For Accelerated Materials Discovery

Atomistic defects play a pivotal role in functional and structural materials’ performance across a myriad of technology applications. Quantitative prediction of the thermodynamics and kinetics of defect formation and migration, respectively, typically requires accurate but expensive first-principles approaches, such as density functional theory (DFT). Their computational expense limits the throughput needed to perform high-throughput materials discovery/screening exercises or to perform materials modeling tasks relying on extensive sampling techniques. Therefore, in this Sandia National Laboratories Laboratory Directed Research and Development (LDRD) project (Project #229366), we developed a variety of machine learning techniques, trained on density functional theory calculations, to accelerate the discovery and modeling of materials in which vacancy and interstitial defects primarily dictate material performance. These include applications such as metal oxides for water-splitting or mixed ionic-electronic conduction, metal hydrides for hydrogen storage, and transition metal dichalcogenides for electronics, and the approaches developed herein can further be applied to many other domains that similarly depend on materials’ thermodynamic and kinetic defect properties for their desired functionality.

36 MATERIALS SCIENCE↗

Environmental DNA Detection in Marine Macrophyte Ecosystems as a Potential Blue Carbon Source in Sediments

“Blue carbon” refers to the carbon sequestered by the world’s oceanic and coastal ecosystems, particularly through coastal vegetation such as mangroves, salt marshes, seagrasses, and marine macroalgae. These ecosystems play a crucial role in the global carbon cycle by serving as significant carbon sinks, absorbing carbon dioxide from the atmosphere and storing it in biomass and sediments over long periods. This study explores the use of environmental DNA (eDNA) to detect marine macrophytes and microalgae assemblages contributing to blue carbon in sediments across various coastal ecosystems. The research addresses the challenges of traditional monitoring methods by utilizing high-throughput sequencing of the 18S-V9 region amplified using eDNA from sediment samples collected at eight locations in the United States and South Korea. The results reveal a diverse array of taxa, underscoring the variability in community composition across different conditions. Notably, sites with seagrass beds and Ulva blooms showed distinct patterns in microalgal community structure. This study underscores the potential of eDNA analysis in providing comprehensive insights into the biodiversity of marine macrophyte ecosystems, thus informing conservation efforts and enhancing the understanding of marine ecological dynamics.

Xing, Qikun (ORCID:0000000206179027)↗

High-Throughput Electric-Field-Assisted Sintering and Characterization Techniques for Materials Discovery

Despite improvements in computing and modeling capabilities, the performance of new materials, particularly those which deviate greatly in composition from well-studied materials (e.g., high-entropy alloys), can be difficult to simulate given the lack of available experimental property data. While some modeling techniques may attempt to predict the properties of these exotic materials, most are forced to make extrapolations from more traditional materials. To fulfill the need for accelerated material synthesis and property measurement, a high-throughput methodology has been developed. Utilizing electric-field-assisted sintering (EFAS), also known as spark plasma sintering (SPS), equipped with custom tooling, samples of differing alloy compositions can be produced simultaneously as a single alloy array. Several arrays have been produced with compositions spanning the Co-Cr-Fe-Mn-Ni alloy family, including many high-entropy alloys, while the novel array geometry has enabled the samples to be polished and characterized in parallel, using X-ray diffraction, scanning-electron microscopy, and laser-based thermal diffusivity measurements.

36 MATERIALS SCIENCE↗

A high-volume resonator for L-band DNP-NMR

DNP-NMR and EPR experiments that operate at or greater than L-band (i.e., ν 0 (e – ) = 1–2 GHz) are typically limited to maximum sample volumes of several hundred µL. These experiments rely on well-known resonator designs for DNP/EPR irradiation such as the loop-gap resonator and Alderman-Grant coil, where their maximum volumes limit further application to imaging experiments and high-throughput screening beyond L-band. Herein, we demonstrate a birdcage (BC) resonator design that can accommodate several mL of sample while operating around 1.5 GHz. The sample volume is maximized by using two identical BC resonators in a stacked configuration. Simulations are used to optimize the BC design and the performance is validated experimentally with liquid-state Overhauser-DNP-NMR experiments. This BC design exploits just the parasitic capacitance of conductive rings and features no fixed tuning capacitors. An enhancement of –77 is achieved on a 10 mM 4-Amino-TEMPO in H 2 O sample for a 5 mL sample volume. Finally, the associated sample heating is minimal due to the low-E-fields generated and the large sample mass with +3.4 K when driving 100 W for several seconds.

47 OTHER INSTRUMENTATION↗

An automated platform for in situ serial crystallography at room temperature

Direct observation of functional motions in protein structures is highly desirable for understanding how these nanomachineries of life operate at the molecular level. Because cryogenic temperatures are non-physiological and may prohibit or even alter protein structural dynamics, it is necessary to develop robust X-ray diffraction methods that enable routine data collection at room temperature. We recently reported a crystal-on-crystal device to facilitate in situ diffraction of protein crystals at room temperature devoid of any sample manipulation. Here an automated serial crystallography platform based on this crystal-on-crystal technology is presented. A hardware and software prototype has been implemented, and protocols have been established that allow users to image, recognize and rank hundreds to thousands of protein crystals grown on a chip in optical scanning mode prior to serial introduction of these crystals to an X-ray beam in a programmable and high-throughput manner. This platform has been tested extensively using fragile protein crystals. We demonstrate that with affordable sample consumption, this in situ serial crystallography technology could give rise to room-temperature protein structures of higher resolution and superior map quality for those protein crystals that encounter difficulties during freezing. This serial data collection platform is compatible with both monochromatic oscillation and Laue methods for X-ray diffraction and presents a widely applicable approach for static and dynamic crystallographic studies at room temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The local metallicity-surface brightness relationship in galactic disks

We present the results of a first attempt to employ multiaperture masks to obtain spectrophotometry of H II regions in nearby galaxies. A total of 97 H II regions in six southern spiral galaxies were observed using a combination of multiaperture masks and conventional long-slit spectrophotometry. The oxygen abundances derived from the multiaperture mask observations using the empirical abundance diagnostic R(sub 23) are shown to be consistent with those from long-slit spectra and generally show better reproducibility and object definition. Although the number of objects that can be observed simultaneously with this particular system is still quite limited compared with either imaging spectrophotometry or fiber-fed spectrographs, the spectral resolution offered and high throughput in the blue help make multiaperture spectrophotometry a competitive technique for increasing the sampling of H II regions in both radial distance and luminosity. There is still no clear trend of abundance gradient with either the galaxy's luminosity or its Hubble type, although the extrapolated central abundance does appear to correlate with galaxy luminosity/mass. In order to avoid difficulty in choosing an appropriate normalizing radius, we instead plot the oxygen abundance against the underlying I-band surface brightness at the radial distance of the H II region and confirm the existence of a local metallicity-surface brightness reltaionship within the disks of spiral galaxies. Although the simple closed-boc model of galaxy evolution predicts almost the right form of this relationship, a more realistic multizone model employing expnentially decreasing gas infall provides a more satisfactory fit to the observational data, provided the expected enriched gas return from dying low-mass stars shedding their envelopes at late epochs is properly taken into account. This same model, with a star formation law based upon self-regulating star formation in a three-dimensional disk (Dopita & Ryder 1994), is equally capable of accounting for the observed relationship between recent massive star formation and stellar surface brightness (Ryder & Dopita 1994).

Ryder, Stuart D.↗