Search NASA⌕ Search

SEARCH · Search NASA

Results for “high-resolution transmission electron microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Topological Spin Textures in an Insulating van der Waals Ferromagnet

Generation and control of topological spin textures constitutes one of the most exciting challenges of modern spintronics given their potential applications in information storage technologies. Of particular interest are magnetic insulators, which due to low damping, absence of Joule heating and reduced dissipation can provide energy-efficient spin-textures platform. Here, it is demonstrated that the interplay between sample thickness, external magnetic fields, and optical excitations can generate a prolific paramount of spin textures, and their coexistence in insulating CrBr 3 van der Waals (vdW) ferromagnets. Using high-resolution magnetic force microscopy and large-scale micromagnetic simulation methods, the existence of a large region in T-B phase diagram is demonstrated where different stripe domains, skyrmion crystals, and magnetic domains exist and can be intrinsically selected or transformed to each-other via a phase-switch mechanism. Lorentz transmission electron microscopy unveils the mixed chirality of the magnetic textures that are of Bloch-type at given conditions but can be further manipulated into Néel-type or hybrid-type via thickness-engineering. The topological phase transformation between the different magnetic objects can be further inspected by standard photoluminescence optical probes resolved by circular polarization indicative of an existence of exciton-skyrmion coupling mechanism. The findings identify vdW magnetic insulators as a promising framework of materials for the manipulation and generation of highly ordered skyrmion lattices relevant for device integration at the atomic level.

36 MATERIALS SCIENCE↗

TEM Approaches for Microstructure-Informed Prediction of Mechanical Properties in Structural Alloys

Predicting the mechanical performance of structural alloys from their evolving microstructure remains a major challenge in materials science, particularly for nuclear structural materials, where irradiation-induced defects span multiple types and length scales and interact through complex mechanisms. The dispersed barrier hardening (DBH) [1] and Friedel–Kroupa–Hirsch (FKH) [2,3] models have been widely used to evaluate the hardening contributions of individual obstacles and to estimate tensile strength from quantified microstructures; however, when multiple size-dependent obstacles coexist and evolve, predicting temperature-dependent tensile strength becomes significantly more complex, and a fully consistent hardening model is still lacking. Transmission electron microscopy (TEM) plays a central role in refining hardening models and enabling predictive assessments of tensile strength evolution by providing quantitative characterization of dislocations, irradiation-induced defects (e.g., dislocation loops and cavities), precipitates, and grain structure (Fig. 1.). These experimentally measured defect densities are incorporated into physically based hardening models with size- and shape- dependent obstacle strengths [4], using root-sum-square superposition for obstacles of comparable strength and linear superposition for dissimilar ones [5]. In addition, recent advances in TEM [6-8], including high-resolution imaging, 4D-STEM strain mapping, EDS/EELS elemental analysis, and flash-polishing-based TEM specimen preparation and extraction-replica methods (Fig. 2), further improve the accuracy of microstructural quantification. By comparison with prior studies as well as our own results, we show that when TEM-derived microstructural information is carefully integrated with physically grounded hardening models, yield strength (or irradiation-induced hardening) measured at room temperature can be predicted with good quantitative agreement across multiple alloy classes. In-situ TEM combined with high-temperature mechanical testing represents an important next step for refining hardening models by directly probing dislocation–obstacle interactions across varying irradiation doses and temperatures [9]. Because the barrier strength factor (α) depends on both temperature and obstacle size, it should not be treated as a constant fitting parameter; rather, it must be explicitly evaluated to achieve physically meaningful predictions of mechanical behaviour at operating temperatures. This presentation therefore discusses why all strengthening contributions (e.g., Peierls stress, solid-solution strengthening, voids, bubbles, dislocation loops, dislocation lines, and grain boundaries) must be considered collectively, why appropriate superposition methods are essential when obstacles possess different barrier strength factors, how hardness measurements can be meaningfully related to tensile properties, and how TEM-derived microstructural information can be systematically incorporated into hardening models. More broadly, it outlines a pathway toward microstructure-informed prediction of mechanical properties and supports the goal of establishing science-based tools for evaluating structural materials in extreme environments [10].

Lin, Yan-Ru [ORNL] (ORCID:0000000339991473)↗

Structural Characterization of Lateral-grown 6H-SiC am-plane Seed Crystals by Hot Wall CVD Epitaxy

The performance of commercially available silicon carbide (SiC) power devices is limited due to inherently high density of screw dislocations (SD), which are necessary for maintaining polytype during boule growth and commercially viable growth rates. The NASA Glenn Research Center (GRC) has recently proposed a new bulk growth process based on axial fiber growth (parallel to the c-axis) followed by lateral expansion (perpendicular to the c-axis) for producing multi-faceted m-plane SiC boules that can potentially produce wafers with as few as one SD per wafer. In order to implement this novel growth technique, the lateral homoepitaxial growth expansion of a SiC fiber without introducing a significant number of additional defects is critical. Lateral expansion is being investigated by hot wall chemical vapor deposition (HWCVD) growth of 6H-SiC am-plane seed crystals (0.8mm x 0.5mm x 15mm) designed to replicate axially grown SiC single crystal fibers. The post-growth crystals exhibit hexagonal morphology with approximately 1500 m (1.5 mm) of total lateral expansion. Preliminary analysis by synchrotron white beam x-ray topography (SWBXT) confirms that the growth was homoepitaxial, matching the polytype of the respective underlying region of the seed crystal. Axial and transverse sections from the as grown crystal samples were characterized in detail by a combination of SWBXT, transmission electron microscopy (TEM) and Raman spectroscopy to map defect types and distribution. X-ray diffraction analysis indicates the seed crystal contained stacking disorders and this appears to have been reproduced in the lateral growth sections. Analysis of the relative intensity for folded transverse acoustic (FTA) and optical (FTO) modes on the Raman spectra indicate the existence of stacking faults. Further, the density of stacking faults is higher in the seed than in the grown crystal. Bundles of dislocations are observed propagating from the seed in m-axis lateral directions. Contrast extinction analysis of these dislocation lines reveals they are edge type basal plane dislocations that track the growth direction. Polytype phase transition and stacking faults were observed by high-resolution TEM (HRTEM), in agreement with SWBXT and Raman scattering.

Single Crystal↗

Uncovering the three-dimensional structure of upconverting core–shell nanoparticles with multislice electron ptychography

In photon upconverting core–shell nanoparticles, structure strongly dictates performance. Typical imaging in scanning transmission electron microscopy has sufficient resolution to probe the atomic structure of these nanoparticles, but contrast, dose, and projection limitations make conventional methods insufficient for fully characterizing these structures. Phase retrieval techniques provide a promising alternative imaging mode, and, in particular, multislice electron ptychography can recover depth-dependent information. Here, we study beam-sensitive photon upconverting core–shell nanoparticles with a multislice ptychography approach using a low electron dose to avoid damage. Large strain fields arise in these heterostructures due to the mismatch in lattice parameter between the core and the shell. We reconstruct both a nanoparticle that appears defect-free and one that has a large break in the side and map the distribution of strain in 3D by computing distortion fields from high-resolution potential images of each slice. In the defect-free nanoparticle, we observe twisting of the shell, while in the broken nanoparticle, we measure the 3D position of the crack, the core, and dislocations. These results highlight the advantage of multislice electron ptychography to recover 3D information from a single scan, even under strict electron dose requirements from beam-sensitive samples.

74 ATOMIC AND MOLECULAR PHYSICS↗

Unraveling Interdiffusion Phenomena and the Role of Nanoscale Diffusion Barriers in the Copper–Gold System

Diffusion is one of the most fundamental concepts in materials science, playing a pivotal role in materials synthesis, forming, and degradation. Of particular importance is solid state interdiffusion of metals which defines the usable parameter space for material combinations in the form of alloys. This parameter space can be explored on the macroscopic scale by using diffusion couples. However, this method reaches its limit when going to low temperatures, small scales, and when testing ultrathin diffusion barriers. Therefore, this work transfers the principle of the diffusion couples to small scales by using core–shell nanowires and in situ heating. This allows us to delve into the interdiffusion dynamics of copper and gold, revealing the interplay between diffusion and the disorder–order phase transition. Our in situ TEM experiments in combination with chemical mapping reveal the interdiffusion coefficients of Cu and Au at low temperatures and highlight the impact of ordering processes on the diffusion behavior. The formation of ordered domains within the solid-solution is examined using high-resolution imaging and nanodiffraction including strain mapping. In addition, we examine the effectiveness of ultrathin Al 2 O 3 barrier layers to control interdiffusion of the diffusion couple. Our findings indicate that a 5 nm thick layer serves as an efficient diffusion barrier. Furthermore, this research provides valuable insights into the interdiffusion behavior of Cu and Au on the nanoscale, offering potential applications in the development of miniaturized integrated circuits and nanodevices.

alloys↗

Holographic Optical Data Storage

Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising, and security medium as well. The evolution of holographic optical memories has followed a path not altogether different from holography itself, with several cycles of alternating interest over the past four decades. P. J. van Heerden is widely credited for being the first to elucidate the principles behind holographic data storage in a 1963 paper, predicting bit storage densities on the order of 1/lambda(sup 3) with source wavelength lambda - a fantastic capacity of nearly 1 TB/cu cm for visible light! The science and engineering of such a storage paradigm was heavily pursued thereafter, resulting in many novel hologram multiplexing techniques for dense data storage, as well as important advances in holographic recording materials. Ultimately, however, the lack of such enabling technologies as compact laser sources and high performance optical data I/O devices dampened the hopes for the development of a commercial product. After a period of relative dormancy, successful applications of holography in other arenas sparked a renewed interest in holographic data storage in the late 1980s and the early 1990s. Currently, with most of the critical optoelectronic device technologies in place and the quest for an ideal holographic recording medium intensified, holography is once again considered as one of several future data storage paradigms that may answer our constantly growing need for higher-capacity and faster-access memories.

Timucin, Dogan A.↗

Temperature-induced degradation of GaN HEMT: An in situ heating study

High-power electronics, such as GaN high electron mobility transistors (HEMTs), are expected to perform reliably in high-temperature conditions. This study aims to gain an understanding of the microscopic origin of both material and device vulnerabilities to high temperatures by real-time monitoring of the onset of structural degradation under varying temperature conditions. This is achieved by operating GaN HEMT devices in situ inside a transmission electron microscope (TEM). Electron-transparent specimens are prepared from a bulk device and heated up to 800 °C. High-resolution TEM (HRTEM), scanning TEM (STEM), energy-dispersive x-ray spectroscopy (EDS), and geometric phase analysis (GPA) are performed to evaluate crystal quality, material diffusion, and strain propagation in the sample before and after heating. Gate contact area reduction is visible from 470 °C accompanied by Ni/Au intermixing near the gate/AlGaN interface. Elevated temperatures induce significant out-of-plane lattice expansion at the SiNx/GaN/AlGaN interface, as revealed by geometry-phase GPA strain maps, while in-plane strains remain relatively consistent. Exposure to temperatures exceeding 500 °C leads to almost two orders of magnitude increase in leakage current in bulk devices in this study, which complements the results from our TEM experiment. The findings of this study offer real-time visual insights into identifying the initial location of degradation and highlight the impact of temperature on the bulk device’s structure, electrical properties, and material degradation.

36 MATERIALS SCIENCE↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

High‐throughput combinatorial approach expedites the synthesis of a lead‐free relaxor ferroelectric system

Abstract Developing novel lead‐free ferroelectric materials is crucial for next‐generation microelectronic technologies that are energy efficient and environment friendly. However, materials discovery and property optimization are typically time‐consuming due to the limited throughput of traditional synthesis methods. In this work, we use a high‐throughput combinatorial synthesis approach to fabricate lead‐free ferroelectric superlattices and solid solutions of (Ba 0.7 Ca 0.3 )TiO 3 (BCT) and Ba(Zr 0.2 Ti 0.8 )O 3 (BZT) phases with continuous variation of composition and layer thickness. High‐resolution x‐ray diffraction (XRD) and analytical scanning transmission electron microscopy (STEM) demonstrate high film quality and well‐controlled compositional gradients. Ferroelectric and dielectric property measurements identify the “optimal property point” achieved at the composition of 48BZT–52BCT. Displacement vector maps reveal that ferroelectric domain sizes are tunable by varying {BCT–BZT} N superlattice geometry. This high‐throughput synthesis approach can be applied to many other material systems to expedite new materials discovery and properties optimization, allowing for the exploration of a large area of phase space within a single growth. image

36 MATERIALS SCIENCE↗

Integrating Experiments and Simulations to Reveal Anisotropic Growth Mechanisms and Interfaces of a One-Dimensional Zeolite

Zeolites are nanoporous crystalline materials critical for diverse industrial applications, yet their growth mechanisms are poorly understood. Here, this study presents a novel integrated framework combining experimental synthesis, high-resolution imaging, coarse-grained molecular dynamics simulations, and computer vision to uncover the mechanisms of growth of SSZ-24, a 1D channel zeolite. We demonstrate how synthesis conditions, such as temperature and reactant concentration, govern crystal anisotropy and surface roughness with growth dynamics differing markedly by crystallographic orientation. Along the channels, growth involves minimal energy barriers and rapid nucleation, resulting in rough surfaces. In contrast, growth perpendicular to the channels requires cooperative molecular organization and is highly sensitive to thermodynamic and kinetic conditions, yielding smooth anisotropic surfaces under low driving forces. By simulating transmission electron microscopy (TEM) images, we bridge molecular-scale simulations with experimental observations, identifying distinct growth mechanisms along different crystal planes. This work offers molecular-level insights into zeolite crystallization, advancing the rational design of nanoporous materials. The integration of cross-disciplinary methodologies establishes a transformative framework for optimizing zeolite synthesis, with implications for broader classes of materials.

Bertolazzo, Andressa A. [Univ. of Utah, Salt Lake ↗

Atom Efficiency of Pd Sites for Methane Combustion: Single Atom Catalysts Versus Nanocatalysts

Methane combustion is an important reaction for energy production and methane removal from the atmosphere. This reaction highly relies on the use of noble metal Pd-based catalysts, which therefore drives the pursuit of catalysts with high atomic dispersion and activity. In this work, Pd/ceria catalysts dominated with Pd single atoms or nanosized Pd clusters (∼1 nm) are prepared and characterized by combining high-resolution high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM), in situ diffuse reflectance infrared Fourier-transform spectroscopy (DRIFTS), and Raman and X-ray absorption spectroscopy (XAS) techniques. By comparing the turnover frequencies (TOF; per every Pd atom) of Pd/ceria single atom catalysts and nanocatalysts, it is found that the atom efficiency of Pd is increased by 10 ∼30 times from single atom catalysts to nanocatalysts. For Pd single atom catalysts, although their activity can be tuned by changing the local structures, the intrinsic activity and number of active sites need to be further improved by engineering the surfaces of supports. For nanosized Pd species, despite the high TOF, the Pd atoms in the bulk structure are not directly participating in the catalytic reaction. Furthermore, this work highlights the importance of increasing the intrinsic activity of individual noble atoms, as well as the homogeneity of their local structures. For Pd/ceria systems reported in this work, our results indicate that from the application point of view, at the current stage, it is not practical to replace Pd nanocatalysts with single atom catalysts for methane combustion.

Pd↗

Nanoscopic Imaging of Self-Propelled Ultrasmall Catalytic Nanomotors

Ultrasmall nanomotors (<100 nm) are highly desirable nanomachines for their size-specific advantages over their larger counterparts in applications spanning nanomedicine, directed assembly, active sensing, and environmental remediation. While there are extensive studies on motors larger than 100 nm, the design and understanding of ultrasmall nanomotors have been scant due to the lack of high-resolution imaging of their propelled motions with orientation and shape details resolved. Here, we report the imaging of the propelled motions of catalytically powered ultrasmall nanomotors─hundreds of them─at the nanometer resolution using liquid-phase transmission electron microscopy. These nanomotors are Pt nanoparticles of asymmetric shapes (“tadpoles” and “boomerangs”), which are colloidally synthesized and observed to be fueled by the catalyzed decomposition of NaBH4 in solution. Statistical analysis of the orientation and position trajectories of fueled and unfueled motors, coupled with finite element simulation, reveals that the shape asymmetry alone is sufficient to induce local chemical concentration gradient and self-diffusiophoresis to act against random Brownian motion. Our work elucidates the colloidal design and fundamental forces involved in the motions of ultrasmall nanomotors, which hold promise as active nanomachines to perform tasks in confined environments such as drug delivery and chemical sensing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Size-Resolved Shape Evolution in Inorganic Nanocrystals Captured via High-Throughput Deep Learning-Driven Statistical Characterization

Precise size and shape control in nanocrystal synthesis is essential for utilizing nanocrystals in various industrial applications, such as catalysis, sensing, and energy conversion. However, traditional ensemble measurements often overlook the subtle size and shape distributions of individual nanocrystals, hindering the establishment of robust structure–property relationships. In this study, we uncover intricate shape evolutions and growth mechanisms in Co 3 O 4 nanocrystal synthesis at a subnanometer scale, enabled by deep-learning-assisted statistical characterization. By first controlling synthetic parameters such as cobalt precursor concentration and water amount then using high resolution electron microscopy imaging to identify the geometric features of individual nanocrystals, this study provides insights into the interplay between synthesis conditions and the sizedependent shape evolution in colloidal nanocrystals. Utilizing population-wide imaging data encompassing over 441,067 nanocrystals, we analyze their characteristics and elucidate previously unobserved size-resolved shape evolution. This high-throughput statistical analysis is essential for representing the entire population accurately and enables the study of the size dependency of growth regimes in shaping nanocrystals. Our findings provide experimental quantification of the growth regime transition based on the size of the crystals, specifically (i) for faceting and (ii) from thermodynamic to kinetic, as evidenced by transitions from convex to concave polyhedral crystals. Additionally, we introduce the concept of an “onset radius,” which describes the critical size thresholds at which these transitions occur. This discovery has implications beyond achieving nanocrystals with desired morphology; it enables finely tuned correlation between geometry and material properties, advancing the field of colloidal nanocrystal synthesis and its applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Molecular-resolution imaging of ice crystallized from liquid water by cryogenic liquid-cell TEM

Despite the ubiquity of ice, a molecular-resolution image of nanoscopic defects or microstructures in ice crystallized from liquid water has never been obtained. This is mainly due to the difficulties in preparing and preserving crystalline ice samples that can survive under high-resolution imaging conditions. Here, we report the stabilization and Å-resolution electron imaging of ice Ih crystallized from liquid water by developing cryogenic liquid-cell transmission electron microscopy (CRYOLIC-TEM). We combine lattice mapping with molecular dynamics simulations to reveal that ice formation is highly tolerant to nanoscale defects such as misoriented subdomains and trapped gas bubbles, which are stabilized by molecular-scale structural motifs. Importantly, bubble surfaces adopt low-energy nanofacets and create negligible strain fields in the surrounding crystal. These bubbles can dynamically nucleate, grow, migrate, dissolve, and coalesce under electron irradiation and be monitored in situ near a steady state. This work improves our understanding of water crystallization behaviors at a molecular spatial resolution.

Materials science↗

NiGa 2 O 4 interfacial layers in NiO/Ga 2 O 3 heterojunction diodes at high temperature

NiO/Ga 2 O 3 heterojunction diodes have attracted attention for high-power applications, but their high temperature performance and reliability remain underexplored. Here, we report the time evolution of the electrical properties in the widely studied p-NiO/n-Ga 2 O 3 heterojunction diodes and formation of NiGa 2 O 4 interfacial layers at high temperatures. Results of our thermal cycling experiment show an initial leakage current increase which stabilizes after sustained thermal load, due to reactions at the NiO–Ga 2 O 3 interface. High-resolution TEM microstructure analysis of the devices after thermal cycling indicates that the NiO–Ga 2 O 3 interface forms a ternary compound at high temperatures, and thermodynamic calculations suggest the formation of the spinel NiGa 2 O 4 layer between NiO and Ga 2 O 3 . First-principles defect calculations find that NiGa 2 O 4 shows low p-type intrinsic doping and hence can serve to limit electric field crowding at the interface. Vertical NiO/ Ga 2 O 3 diodes with intentionally grown 5 nm thin spinel-type NiGa 2 O 4 interfacial layers show an excellent device ON/OFF ratio of >10 10 (± 3 V), V ON of ~1.9 V, and increased breakdown voltage of ~1.2 kV for an initial unoptimized 300 lm diameter device. These p–n heterojunction diodes are promising for high-voltage, high temperature applications.

30 DIRECT ENERGY CONVERSION↗

Freeze It or Leave It? Evaluating the Role of Cryo-Electron Microscopy in Battery Research

Cryogenic electron microscopy (cryo-EM) continues to gain prominence in materials science, particularly in battery research where it has enabled high-resolution, multimodal characterization of electrode materials and interfaces that otherwise degrade quickly under electron beam irradiation. But as anyone who has attempted cryo-EM techniques knows, freezing comes at a cost; cryo-EM experiments are time-consuming, highly sensitive, and carry an increased risk of artifacts due to issues such as frost contamination. Thus, when planning new characterization of battery materials or other beam-sensitive samples, it is critical to consider whether (and which) cryo-EM techniques are appropriate, based on study goals and an understanding of electron beam-sample interactions. Here we review such considerations for battery materials to elucidate the questions of when, why, and how to freeze to achieve high-quality characterization.

25 ENERGY STORAGE↗

Quantitative Modeling of High-Energy Electron Scattering in Thick Samples Using Monte Carlo Techniques

Cryo-electron microscopy (cryo-EM) is a powerful tool for imaging biological samples but is typically limited by sample thickness, which is restricted to a few hundred nanometers depending on the electron energy. However, there is a growing need for imaging techniques capable of studying biological samples up to 10 µm in thickness while maintaining nanoscale resolution. This need motivates the use of mega-electron-volt scanning transmission electron microscopy (MeV-STEM), which leverages the high penetration power of MeV electrons to generate high-resolution images of thicker samples. In this study, we employ Monte Carlo simulations to model electron–sample interactions and explore the signal decay of imaging electrons through thick specimens. By incorporating material properties, interaction cross-sections for energy loss, and experimental parameters, we investigate the relationship between the incident and transmitted beam intensities. Key factors such as detector collection angle, convergence semi-angle, and the material properties of samples were analyzed. Our results demonstrate that the relationship between incident and transmitted beam intensities follows the Beer–Lambert law over thicknesses ranging from a few microns to several tens of microns, depending on material composition, electron energy, and collection angles. The linear depth of silicon dioxide reaches 3.9 µm at 3 MeV, about 6 times higher than that at 300 keV. Meanwhile, the linear depth of amorphous ice reaches 17.9 µm at 3 MeV, approximately 11.5 times higher than that at 300 keV. These findings are crucial for advancing the study of thick biological and semiconductor samples using MeV-STEM.

36 MATERIALS SCIENCE↗

Application of an alkylammonium method for characterization of phyllosilicates in CI chondrites

Many meteorites and interplanetary dust particles (IDP's) with primitive compositions contain significant amounts of phyllosilicates, which are generally interpreted as evidence of protoplanetary aqueous alteration at an early period in the solar system. These meteorites are chondrites of the carbonaceous and ordinary varieties. Characterization of phyllosilicates in these materials is important because of the important physico-chemical information they hold, e.g., from well characterized phyllosilicates, thermodynamic stability relations and hence the conditions of formation of phyllosilicates in the parent body of the meteorite can be predicted. Although we are at a rudimentary level of understanding of the minerals resulting from the aqueous alteration in the early solar nebula, we know that the most common phyllosilicates present in chondritic extraterrestrial materials are serpentines, smectites, chlorites, and micas. The characterization of fine grained minerals in meteorites and IDP's rely heavily on electron beam instruments, especially transmission electron microscopy (TEM). Typically, phyllosilicates are identified by a combination of high resolution imaging of basal spacings, electron diffraction analysis, and chemical analysis. Smectites can be difficult to differentiate from micas because the smectites loose their interlayer water and the interlayers collapse to the same basal spacing as mica in the high vacuum of the TEM. In high-resolution TEM (HRTEM) images, smectite basal spacings vary from 1 nm up to 1.5 nm, while micas show 1 or 2 nm basal spacings. Not only is it difficult to differentiate smectites from micas, but there is no way of identifying different classes of smectites in meteorites and IDP's. To differentiate smectites from micas and also to recognize the charge differences among smectites, an alkylammonium method can be employed because the basal spacings of alkylammonium saturated smectites expand as a function of alkylamine chain length and the layer-charge density of the 2:1 expanding phyllosilicate, and the final product is significantly more stable under electron beam examination. Such a method was tested on standard clays and several meteorite samples using four alkylammonium salts.

Golden, D. C.↗