Search NASA⌕ Search

SEARCH · Search NASA

Results for “hot liquid water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Investigation of isovaline enantiomeric excesses in CM meteorites using liquid chromatography time of flight mass spectrometry

The enantiomeric abundances of the alpha-dialkyl amino acid isovaline were measured in the CM2 meteorites Murchison and LEW 90500 using a new liquid chromatography-time of flight-mass spectrometry (LC-ToF-MS) technique coupled with OPA/NAC derivatization and UV fluorescence detection. Previous analyses of Murchison have shown that L-enantiomeric excesses of isovaline range from 0 to 15.2% with significant variation between meteorite fragments [1]. For this study, hot water extracts of interior fragments (> 2 cm from fusion crust) of the Murchison (USNM 6650.2, mass 6 g) and LEW 90500 (split 69, parent 1, mass 5 g) carbonaceous meteorites were analyzed. Enantiomeric excesses were measured using the single ion LC-ToF-MS trace for the OPA/NAC derivative of isovaline at d z 393.15 (Fig. 1). L-isovaline excesses in these meteorite samples ranged from 18.9 to 20.5% for Murchison and -0.5 to 3.0% for LEW 90500. The measured values for Murchison are the largest enantiomeric excesses for isovaline reported to date. The enantiomeric excesses of L-isovaline cannot be the result of interference from other C5 amino acid isomers present in the meteorites or terrestrial contamination from the landing site environments. The L-isovaline excesses in Murchison are inconsistent with the synthesis of all of the isovaline by the Strecker-cyanohydrin pathway on the CM meteorite parent body. The mechanism(s) for the formation of the enantiomeric asymmetry in isovaline in Murchison are currently unknown and it is not clear how the asymmetry of alpha-dialkyl amino acids could be transferred to the a-hydrogen protein amino acids common in all life on Earth today.

Glavin, Daniel P.↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

Mathur, A. K.↗

Computer Modeling Of Atomization

Improved mathematical models based on fundamental principles of conservation of mass, energy, and momentum developed for use in computer simulation of atomization of jets of liquid fuel in rocket engines. Models also used to study atomization in terrestrial applications; prove especially useful in designing improved industrial sprays - humidifier water sprays, chemical process sprays, and sprays of molten metal. Because present improved mathematical models based on first principles, they are minimally dependent on empirical correlations and better able to represent hot-flow conditions that prevail in rocket engines and are too severe to be accessible for detailed experimentation.

Giridharan, M.↗

Indoor test for thermal performance of the Sunmaster evacuated tube (liquid) solar collector

The test procedures used to obtain the thermal performance data for a solar collector under simulated conditions are presented. Tests included a stagnation test, a time constant test, a thermal efficiency test, an incident angle modifier test, and a hot fill test. All tests were performed at ambient conditions and the transient effect and the incident angle effect on the collector were determined. The solar collector is a water working fluid type.

Source record↗

Solar heating and hot water system installed at James Hurst Elementary School, Portsmouth, Virginia

Solar heating and a hot water system installed in an elementary school in Portsmouth, Virginia are examined. The building is zoned into four heating/cooling areas. Each area is equipped with an air handling unit that is monitored and controlled by central control and monitoring system. The solar system for the building uses a collector area of 3,630 sq. ft. of flat plate liquid collectors, and a 6,000 gallon storage tank. System descriptions, maintenance reports, detailed component specifications, and design drawings to evaluate this solar system are reported.

Source record↗

Subsurface microbial habitats on Mars

We developed scenarios for shallow and deep subsurface cryptic niches for microbial life on Mars. Such habitats could have considerably prolonged the persistence of life on Mars as surface conditions became increasingly inhospitable. The scenarios rely on geothermal hot spots existing below the near or deep subsurface of Mars. Recent advances in the comparatively new field of deep subsurface microbiology have revealed previously unsuspected rich aerobic and anaerobic microbal communities far below the surface of the Earth. Such habitats, protected from the grim surface conditions on Mars, could receive warmth from below and maintain water in its liquid state. In addition, geothermally or volcanically reduced gases percolating from below through a microbiologically active zone could provide the reducing power needed for a closed or semi-closed microbial ecosystem to thrive.

Boston, P. J.↗

Preconditioning of overcast-to-broken cloud transitions by riming in marine cold air outbreaks

Marine cold air outbreaks (CAOs) commonly form overcast cloud decks that transition into broken cloud fields downwind, dramatically altering the local radiation budget. In this study, we investigate the impact of frozen hydrometeors on these transitions. We focus on a CAO case in the NW Atlantic, the location of the multi-year flight campaign ACTIVATE (Aerosol Cloud meTeorology Interactions oVer the western ATlantic Experiment). We use MERRA-2 (Modern-Era Retrospective analysis for Research and Applications, version 2) reanalysis fields to drive large eddy simulations with mixed-phase two-moment microphysics in a Lagrangian framework. We find that transitions are triggered by substantial rain (rainwater paths >25 g m−2), and only simulations that allow for aerosol depletion result in sustained breakups, as observed. Using a range of diagnostic ice nucleating particle concentrations, Ninp, we find that increasing ice progressively accelerates transitions, thus abbreviating the overcast state. Ice particles affect the cloud-topped boundary layer evolution, primarily through riming-related processes prior to substantial rain, leading to (1) a reduction in cloud liquid water, (2) early consumption of cloud condensation nuclei, and (3) early and light precipitation cooling and moistening below cloud. We refer to these three effects collectively as “preconditioning by riming”. Greater boundary layer aerosol concentrations available as cloud condensation nuclei (CCN) delay the onset of substantial rain. However, cloud breakup and low CCN concentration final stages are found to be inevitable in this case, due, primarily, to liquid water path buildup. An ice-modulated cloud transition speed suggests the possibility of a negative cloud–climate feedback. To address prevailing uncertainties in the model representation of mixed-phase processes, the magnitude of ice formation and riming impacts and, thereby, the strength of an associated negative cloud–climate feedback process, requires further observational evaluation by targeting riming hot spots with in situ imaging probes that allow for both the characterization of ice particles and abundance of supercooled droplets.

Marine cold air outbreaks↗

Performance of a transpiration-regenerative cooled rocket thrust chamber

The analysis, design, fabrication, and testing of a liquid rocket engine thrust chamber which is gas transpiration cooled in the high heat flux convergent portion of the chamber and water jacket cooled (simulated regenerative) in the barrel and divergent sections of the chamber are described. The engine burns LOX-hydrogen propellants at a chamber pressure of 600 psia. Various transpiration coolant flow rates were tested with resultant local hot gas wall temperatures in the 800 F to 1400 F range. The feasibility of transpiration cooling with hydrogen and helium, and the use of photo-etched copper platelets for heat transfer and coolant metering was successfully demonstrated.

Valler, H. W.↗

Dimensionless parameters for cloudy Rayleigh-Bénard convection: Supersaturation, Damköhler, and Nusselt numbers

In steady-state Rayleigh-Bénard convection, heat is transported by turbulent thermal convection from the bottom, hot surface to the top, cold surface, leading to a height-independent sensible heat flux. When water vapor is present and cloud formation occurs, there is also an additional latent heat flux. Heat transport in cloudy Rayleigh-Bénard convection depends on turbulent flow as well as the microphysical state of the clouds: specifically, whether substantial supersaturations exist and whether cloud liquid water is removed through sedimentation/precipitation. In this article we bridge between the Rayleigh-Bénard convection literature and the atmospheric literature. We express the governing equations for cloudy convection in dimensionless form, thereby explicitly identifying the governing parameters relevant to the cloudy case, including Schmidt, Damköhler, supersaturation, and sedimentation numbers. We further connect to the atmospheric literature by obtaining a Nusselt number (dimensionless heat flux) for a cloud-convection system, directly from the conservation equations for temperature and water vapor. This flux has the same form as that identified by Zhang et al. [L. Zhang, K. L. Chong, and K.-Q. Xia, J. Fluid Mech. 874, 1041 (2019)] for convection with water vapor, but is extended to the cloudy case. For equal thermal and water vapor diffusivities, the flux corresponds to the widely used atmospheric quantities equivalent temperature and moist static energy. Using large eddy simulation (LES) of an idealized cloudy Rayleigh-Bénard convection system with fixed boundary conditions, we find that the equivalent heat flux (Nusselt number) is only weakly dependent on the microphysical details of the system, such as liquid water mixing ratio and cloud droplet number concentration. Finally, from the results, we show the vertical profiles of sensible and latent heat fluxes depend on the liquid water content, whereas the equivalent heat flux remains a constant throughout the height of the chamber.

54 ENVIRONMENTAL SCIENCES↗

Amino acids in the Martian meteorite Nakhla

A suite of protein and nonprotein amino acids were detected with high-performance liquid chromatography in the water- and acid-soluble components of an interior fragment of the Martian meteorite Nakhla, which fell in Egypt in 1911. Aspartic and glutamic acids, glycine, alanine, beta-alanine, and gamma-amino-n-butyric acid (gamma-ABA) were the most abundant amino acids detected and were found primarily in the 6 M HCl-hydrolyzed, hot water extract. The concentrations ranged from 20 to 330 parts per billion of bulk meteorite. The amino acid distribution in Nakhla, including the D/L ratios (values range from <0.1 to 0.5), is similar to what is found in bacterially degraded organic matter. The amino acids in Nakhla appear to be derived from terrestrial organic matter that infiltrated the meteorite soon after its fall to Earth, although it is possible that some of the amino acids are endogenous to the meteorite. The rapid amino acid contamination of Martian meteorites after direct exposure to the terrestrial environment has important implications for Mars sample-return missions and the curation of the samples from the time of their delivery to Earth.

NASA Discipline Exobiology↗

Current Ground Test Options for Nuclear Thermal Propulsion (NTP)

About 20 different NTP engines/ reactors were tested from 1959 to 1972 as part of the Rover and Nuclear Engine for Rocket Vehicle Application (NERVA) program. Most were tested in open air at test cell A or test cell C, at the Nevada Test Site (NTS). Even after serious engine breakdowns of the reactor (e.g., Phoebus 1A), the test cells were cleaned up for other engine tests. The engine test stand (ETS) was made for high altitude (approximately 1 psia) testing of an NTP engine with a flight configuration, but still had the exhaust released to open air. The Rover/NERVA program became aware of new environmental regulations which would prohibit the release of any significant quantity of radioactive particulates and noble gases into the open air. The nuclear furnace (NF-1) was the last reactor tested before the program was cancelled in 1973, but successfully demonstrated a scrubber concept on how to filter the NTP exhaust. The NF-1 was demonstrated in the summer of 1972. The NF-1 used a 44MW reactor and operated each run for approximately 90 minutes. The system cooled the hot hydrogen exhaust from the engine with a water spray before entering a particle filter. The exhaust then passed through a series of heat exchangers and water separators to help remove water from the exhaust and further reduce the exhaust temperatures. The exhaust was next prepared for the charcoal trap by passing through a dryer and effluent cooler to bring exhaust temperatures close to liquid nitrogen. At those low temperatures, most of the noble gases (e.g., Xe and Kr made from fission products) get captured in the charcoal trap. The filtered hydrogen is finally passed through a flare stack and released to the air. The concept was overall successful but did show a La plating on some surfaces and had multiple recommendations for improvement. The most recent detailed study on the NTP scrubber concept was performed by the ARES Corporation in 2006. The concept is based on a 50,000 lbf thrust engine (approximately 1 GW) with a maximum burn time of 1 hour. The concept utilized lessons learned from NF-1. The strategy breaks down the exhaust into parallel paths to allow flexibility with engine size and mass flow of exhaust. Similar to NF-1, the exhaust is slowed down, cooled, filtered of particulates, filtered of noble gases, and then the clean hydrogen is flared to open air. Another concept proposed by Steve Howe (currently Director of the Center for Space Nuclear Research) to simplify the NTP exhaust filtering is to run the hydrogen exhaust into boreholes underground to filter the exhaust. The two borehole site locations proposed are at the NTS and at the Idaho National Laboratory (INL). At NTS, the boreholes are 8' diameter and 1200' deep. The permeability of hydrogen through the soil and its buoyancy will allow it to rise up through the soil and allow the filtering of noble gases and radioactive particulates. The exhaust needs to be cooled to 600C before entering the borehole to avoid soil glazing. Preliminary analysis shows a small buildup of back pressure with time which depends on permeability. Noble gases entering the borehole walls deep can take a long time before reaching the surface. Other factors affecting permeability include borehole pressure, water saturation, and turbulence. Also, a possible need to pump out contaminated water collected at the bottom of the borehole. At INL, the borehole concept is slightly different. The underground borehole has openings to the soil at special depths which have impermeable interbeds above the water table and below the surface to allow the exhaust to travel horizontal between the impermeable layers. Preliminary results indicate better permeability than at NTS. The last option is total containment of the exhaust during the test run. The concept involves slowing down the flow to subsonic in a water cooled diffuser. The hydrogen is burned off in an oxygen rich afterburner with the only products being steam, oxygen, and some noble gases. A heat exchanger and water spray pulls heat from the steam and lowers the temperature for condensation. The optimum ratio between the two is being investigated, with a goal to minimize the total volume of the water hold tanks. A water tank farm collects the contaminated water. The amount of water produced from burning the hydrogen is approximately 100,000 gallons (not including cooling water) for a 25k lbf engine operating for 50 minutes. Residual gases (e.g., oxygen and some noble gases) can be captured at cryogenic levels with a liquid nitrogen cooled dewar. After a few weeks post-test, the radiation levels can drop to more favorable levels before slowly draining each capture tank and using existing filters. With today's environmental regulations, the NTP exhaust is filtered to meet 10 mrem/year exposure to the general public (at a DOE site) or 100 mrem/year (via NRC when tested elsewhere), when natural background radiation exposure to the general public is 300- 600 mrem per year. The current society feels more comfortable with filtering even lower to as low as reasonably achievable (ALARA).

Gerrish, Harold P., Jr.↗

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Spacesuit↗

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Human Thermal Modeling↗

Salts in Hot Water: Developing a Scientific Basis for Supercritical Desalination and Strategic Metal Recovery

Given the steady growth in world population and the ever-increasing fresh water demand, the only sustainable water supply option is desalination. Conceptually, desalination is very simple - just separate dissolved salts from water. While desalination research programs have existed since the 1960s and have resulted in a multitude of approaches, realizing affordable desalination has proven to be a challenge. Our goal is to meet this challenge using low cost heat sources to drive a liquid-discharge-free desalination process that can be co-mingled with the extraction of economically valuable co-products. High temperatures and pressures will be used to manipulate water’s properties, such as the dielectric constant, and hence its ability to solvate ions. Selective precipitation/recovery of valuable metal co-products creates new revenue streams (i.e., cost offsets). We will develop the scientific understanding necessary to control salt precipitation from supercritical seawater, inland brines, and water commonly co-produced with oil and gas. Atomistic simulations will be used to understand at a molecular level the changes in hydrogen bonding and ion solvation that occur as we increase the temperature and/or pressure and change the density and ion concentration. Our simulation results will also aid in the interpretation of experimental data and guide the development of applied thermodynamic models for engineering design calculations.

58 GEOSCIENCES↗

Experimental fatigue life investigation of cylindrical thrust chambers

The thrust chambers studied in the investigation have been designed for a possible use in the Space Shuttle main engine. An annular combustion chamber configuration was used, consisting of an annular injector, a liquid hydrogen cooled outer cylinder, which served as the test section, and a contoured water cooled centerbody which formed the throat. Twenty-two cylinders were fabricated by milling cooling channels into liners fabricated from the material to be evaluated. The three materials chosen for the liners include OFHC copper, Amzirc, and NARloy-Z. The cylinders were cyclically tested until failure occurred due to fatigue cracks in the hot-gas-side wall. It was found that cylinders with liners fabricated from NARloy-Z and aged Amzirc had the best cyclic life characteristics.

Quentmeyer, R. J.↗

Development of an improved model for runback water on aircraft surfaces

A computer simulation for 'running wet' and evaporative aircraft anti-icing systems is developed. The model is based on the analysis of the liquid water film which forms in the regions of direct impingement and, then, breaks up near the impingement limits into rivulets. The wetness factor distribution resulting from the film breakup and the rivulet configuration on the surface are predicted using a stability analysis theory and the laws of mass energy conservation. The solid structure is modeled as a multiple layer wall. The anti-icing system modeled is of the thermal type utilizing hot air and/or electrical heating elements embedded within the wall layers. Experimental observations revealing some of the basic physics of the water flow on the surface are presented. Detailed qualitative documentation of the tests are given. Several numerical examples are considered, and the effect of some of the involved parameters on the system performance are investigated.

Al-Khalil, Kamel M.↗

High Temperature Stability of Aqueous Foams for Potential Application in Enhanced Geothermal System (EGS)

Enhanced Geothermal Systems (EGS) are typically constructed by injecting high-pressure water into the deep hot dry rocks (HDR) under carefully controlled conditions to create new or re-open existing fractures, which usually utilizes an immense quantity of water. Alternatively, aqueous foam-based fracturing fluids may offer potential advantages over conventional water-based fracturing fluid, including reduced consumption of water and environmental impact. Although foam-based fracturing has shown promising results in oil and gas industries, its applicability to EGS is unknown. Foams are complex mixtures of liquids with gaseous phases that are thermodynamically unstable. Their stability will decrease over time due to liquid drainage, bubble coarsening, and coalescence. Therefore, it is essential to stabilize foam fluids at high temperatures for EGS related applications such as fracking of HDRs.This paper is focused on investigating high-temperature stability of N2-in-water or N2 foams containing different surfactants and stabilizing agents. Foam stability was characterized by the half-life, which is defined as the time a foam decreases to 50% of its original height due to drainage. Surfactants with various concentrations dissolved in deionized water were investigated, including alfa olefin sulfonate (AOS), sodium dodecyl sulfonate (SDS), TergitolTM (NP – 40), and cetyltrimethylammonium chloride (CTAC). Also, the effects of other stabilizing agents, including guar gum, bentonite clay, crosslinker, graphene oxide (GO) dispersion on foam stability were tested. Initial results showed that foam stability decreased dramatically as temperature increased. On the other hand, foams became relatively more stable as pressure increased. Certain stabilizing agents, such as guar gum and crosslinker, can enhance foam stability at a wide range of temperatures. Our results indicate that it may be possible to obtain stable foams at high-temperature, high-pressure conditions with appropriate stabilizing agents.

Thakore, Virensinh↗