Search NASA⌕ Search

SEARCH · Search NASA

Results for “humidity measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Time-Varying Model for Predicting Formaldehyde Emission Rates in Homes

Recent studies have succeeded in relating emissions of various volatile organic compounds to material mass diffusion transfer using detailed empirical characteristics of each of the individual emitting materials. While significant, the resulting models are often scenario specific and/or require a host of individual component parameters to estimate emission rates. This study developed an approach to estimate aggregated emissions rates based on a wide number of field measurements. We used a multi-parameter regression model based on previous mass transfer models to predict formaldehyde emission rate for a whole dwelling using field-measured, time-resolved formaldehyde concentrations, air exchange rates, and indoor environmental parameters in 63 California single-family houses built between 2011 and 2017. The resulting model provides time-varying formaldehyde emission rates, normalized by floor area, for each study home, assuming a well-mixed mass balance transport model of the home, and a well-mixed layer transport model of indoor surfaces. The surface layer model asserts an equilibrium concentration within the surface layer of the emitted materials that is a function of temperature and RH; the dwelling ventilation rate serves as a surrogate for indoor concentration. We also developed a more generic emission model that is suitable for broad prediction of emission for a population of buildings. This model is also based on measurements aggregated from 27 homes from the same study. We showed that errors in predicting household formaldehyde concentrations using this approach were substantially less than those using a traditional constant emission rate model, despite requiring less unique building information.

54 ENVIRONMENTAL SCIENCES↗

BSEC flux towers: CSAT3B and TRH

The data were collected as part of the BSEC project, during the period from June 2025 to May 2026. Directory "broadway" contains data collected on a multi-level flux tower (US-BWf) in the Broadway East neighborhood (1808 North Patterson Park Ave., Baltimore City, MD 21213; LAT: 39o18'40.31'' N; LONG: 76o35'12.43'' W). At each of the four measurement heights (8.5 m, 11.1 m, 13.4 m, 15.9 m), a Campbell Scientific CSAT3B sonic anemometer was operated at 50 Hz to measure virtual temperature (tc) and three velocity components (u: 270 degrees; v: 180 degrees; w: vertical), and a RM Young temperature sensor (model 41382VC) was operated at 1 Hz inside a compact aspirated radiation shield (model 43502) to measure absolute temperature (T) and relative humidity (RH). Inside directory "broadway", directory "netcdf" contains data collected each day in 5-minute chunks that have been converted to NetCDF format (before quality checking), while "4hr" contains data arranged into 4-hour chunks (also in NetCDF format) that have been through basic quality checking steps (treating data points with nonzero diagnostic codes as missing data; fixing six or fewer consecutive missing data points using linear interpolation). Users are recommended to start with data in directory "4hr", while data in directory "netcdf" can be used for reference purposes.

Baltimore↗

Benchtop-Scale High Temperature Molten Salt Electrochemical Reactors: Experimental Setup and Considerations

Molten salt electrochemical reduction (MSER) is the dominant production method for aluminum and titanium, and emerging technologies for producing other commodity metals with these highly electrified techniques have demonstrated promising results. However, the scale up of MSER of materials such as iron and silicon are limited by the challenging issues of materials compatibility and impurity control. This work describes an experimental MSER setup using both chloride and carbonate salts. This setup is designed for operations outside of a glovebox, which is practical from an industrial perspective, but creates unique challenges. This work serves as a practical guide to discuss some key operational difficulties such as temperature control, air and humidity, material compatibility, developing strong electrical measurements and techniques, and safety.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CROCUS Low Cost All-in-One Weather Station AMB-001 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an API key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-001), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Low Cost All-in-One Weather Station AMB-004 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an Application Programming Interface (API) key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-004), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

EARTH SCIENCE > ATMOSPHERE > AEROSOLS > PARTICULAT↗

CROCUS Low Cost All-in-One Weather Station AMB-002 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an API key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-002), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

54 ENVIRONMENTAL SCIENCES↗

Optical Fiber Sensor with a Hydrophobic Filter Layer for Monitoring Hydrogen under Humid Conditions

Real-time and remote monitoring of hydrogen concentration in underground hydrogen storage reservoirs is crucial to maintaining the integrity and safety of the storage facilities. High humidity in the underground deposits interferes with hydrogen sensors, introducing inaccuracy into the hydrogen sensing measurements. A hydrophobic filter layer over a hydrogen sensing layer on an optical fiber hydrogen sensor was devised to minimize the impact of the humidity on the sensor. The hydrogen sensor coated with a hydrophobic filter layer demonstrated a significant improvement in reliable hydrogen sensing under high humidity conditions (99% RH) without severe baseline drift and reduction of transmission intensity. Finally, the optical fiber hydrogen sensor revamped with the filter layer would enable the reliable measurement of hydrogen concentration under the humid conditions expected in subsurface hydrogen storage facilities.

08 HYDROGEN↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Porous Membranes for Moisture Probe Protection (SR18024)

In the presence of contaminants, moisture probes can give false moisture readings and have shorter lifetimes. Absolute humidity probes are composed of porous, hygroscopic metallic oxide thin films (Al 2 O 3 ) coupled to electrodes (e.g. Au and Al). While these materials provide absolute humidity readings at low water levels at a relatively low cost, they are sensitive to the presence of contaminants, especially ammonia, due to its high hygroscopicity and ability to bind to the probe. Without frequent recalibration, especially in the presence of contaminants, the humidity levels are inaccurately reported due to measurement drift that occurs when the pores close, changing the impedance of the probe. The goal of this project was to improve the stability and reliability of these moisture probes by incorporating a molecular sieve into the probe to allow only the water to reach the sensor. Molecular sieves contain pores that allow molecule specific permeation. Two dimensional inorganic nanosheets (e.g. BN, MoO 2 , MoS 2 ) have recently been shown to behave as molecular sieves for water. Compared to zeolites, nanoporous materials have higher flux rates through the pores, leading to faster water permeation. Graphene oxide sheets have also been successfully employed for unimpeded water permeation; however, at lower humidity levels, the structure is unstable and the pores shrink, preventing the sieving of molecules. Compared to graphene oxide, sheets based off of inorganic materials, such as molybdenum, have been found to be more stable at lower humidity levels and have faster permeation rates. By creating a barrier in before the Al 2 O 3 sensor chip to prevent the permeation of contaminants into the probe, the lifetime of the probe will be extended. While the molybdenum sheets are a promising material for this application, their performance against ammonia and tritiated compounds have not yet been evaluated. This technology can be applied to other applications, including gas and liquid purification for environmental remediation, single molecule sensors, field effect transistors, and catalysts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GreenSight WxHive Unmanned Aerial System (UAS) Atmospheric Profiling at the SGP Central Facility

The GreenSight WxHive is capable of flying multiple nanodrones simultaneously to provide spatiotemporal atmospheric sampling. During the WH2yMSIE campaign, the WxHive would fly up to 5 nanodrones at once, performing profiling within the planetary boundary layer over the ARM SGP Central Facility site. The measurements provided by the WxHive include latitude, longitude, altitude, pressure, temperature, humidity, and wind speed and direction. See the attached WeatherHive User Guide for more details about the instrument and measurements.

Air pressure↗

Morphological Characterization of Uranyl Fluoride Particles via Atomic Force Microscopy

Uranium hexafluoride (UF 6 ) undergoes a rapid hydrolysis reaction when exposed to atmospheric water. In addition to producing hazardous HF gas, the hydrolysis reaction produces uranyl fluoride (UO 2 F 2 ), a radioactive solid phase particulate material. Because of the technological utility of UF 6 in the nuclear fuel cycle, understanding the transport properties of UO 2 F 2 aerosol produced via UF 6 hydrolysis is important for accident scenarios. Moreover, the fundamental chemical and physical properties of the UF 6 hydrolysis reaction are not completely understood. Recently, several experiments on the aerosol phase properties of UO 2 F 2 produced in this way have shown that under most relevant conditions, the particle size distribution (PSD) of UO 2 F 2 can be extremely small, approximately 3 to 5 nm, which is well below the threshold that can be routinely observed via scanning electron microscopy (SEM). Although readily observable in the aerosol phase, observation of nanometer-sized particles in the condensed phase (i.e. deposited on surfaces) remains a challenge. Here, in this study, we have used atomic force microscopy (AFM) to study the PSD and morphological characteristics of UO 2 F 2 deposited at low and high concentrations under different humidity conditions, a primary variable in the hydrolysis reaction. Here, we find strong agreement between PSD measured in the aerosol phase via scanning mobility particle sizing and PSD measured via AFM, with particle sizes peaked below 4 nm for low-humidity conditions. At higher humidity, the distribution is centered around 5 to 10 nm but extends up to 20 nm. These results are in stark contrast to previous measurements using SEM that show PSD on the order of 300- to 1000-nm particle sizes; moreover, these are the first direct measurements of individual particles of UO 2 F 2 having been produced via UF 6 hydrolysis deposited on surfaces. These measurements, therefore, open a new avenue for collecting and detecting UO 2 F 2 in the condensed phase and further refine the PSD, which is critical for environmental transport determinations.

Uranium hexafluoride↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Artificial Intelligence Thermostat to Detect Faults

Residential air conditioners and heat pumps often experience faults due to inadequate maintenance, which can severely reduce efficiency or even cause system failure. Common issues include dirty or clogged air filters and refrigerant leaks. These problems degrade performance and increase energy use and operating costs. This study presents a smart thermostat with embedded artificial intelligence to detect such faults and alert homeowners when maintenance is needed. The thermostat uses low-cost measurements—including return-air temperature, relative humidity, supply-air temperature, outdoor-air temperature, and condenser subcooling—to identify abnormal operations. Because different faults produce distinct response patterns, tailored algorithms are developed to recognize characteristic fault signatures. The investigation is built on a detailed co-simulation platform that couples EnergyPlus with the DOE/ORNL Heat Pump Design Model (HPDM). EnergyPlus represents the building’s dynamic environment, while HPDM is a high-fidelity, hardware-based model that can simulate fault-free performance as well as a wide range of faults, including gradual degradation such as minor refrigerant leakage. This platform provides a virtual training and testing environment that helps distinguish fault-induced behavior from normal operation and supports development of robust diagnostic algorithms. Using this framework, a Dynamic Bayesian Network was developed to identify two common faults—gradual refrigerant charge loss and indoor airflow blockage—and the AI-embedded thermostat was verified through annual building simulations.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Indirect Measurements of the Composition of Ultrafine Particles in the Arctic Late-Winter

In this work, we present indirect measurements of size-resolved ultrafine particle composition conducted during the Ocean-Atmosphere-Sea Ice-Snowpack (OASIS) Campaign in Utqiagvik, Alaska, during March 2009. This study focuses on measurements of size-resolved particle hygroscopicity and volatility measured over two periods of the campaign. During a period that represents background conditions in this location, particle hygroscopic growth factors (HGF) at 90% relative humidity ranged from 1.45 to 1.51, which combined with volatility measurements suggest a mixture of ~30% ammoniated sulfates and ~70% oxidized organics. Two separate regional ultrafine particle growth events were also observed during this campaign. Event 1 coincided with elevated levels of H2SO4 and solar radiation. These particles were highly hygroscopic (HGF = 2.1 for 35 nm particles), but were almost fully volatilized at 160 °C. The air masses associated with both events originated over the Arctic Ocean. Event 1 was influenced by the upper marine boundary layer (200–350 m AGL), while Event 2 spent more time closer to the surface (50–150 m AGL) and over open ocean leads, suggesting marine influence in growth processes. Event 2 particles were slightly less hygroscopic (HGF = 1.94 for 35 nm and 1.67 for 15 nm particles), and similarly volatile. We hypothesize that particles formed during both events contained 60–70% hygroscopic salts by volume, with the balance for Event 1 being sulfates and oxidized organics for Event 2. These observations suggest that primary sea spray may be an important initiator of ultrafine particle formation events in the Arctic late-winter, but a variety of processes may be responsible for condensational growth.

54 ENVIRONMENTAL SCIENCES↗

Development and validation of a humidified CAPS-PMSSA with an improved methodology to calculate the truncation correction factor

Absorbing aerosols play an important role in the Earth’s radiation budget, and current uncertainties associated with their radiative impacts remain substantial. An element of this uncertainty derives from insufficient understanding of the extent to which water, as a coating on absorbing particles, enhances the absorption. Here, we describe and characterize the performance of a cavity-attenuated phase shift single scatter albedo spectrometer (CAPS-PMSSA) system that has been modified to enable concurrent aerosol extinction and scattering measurements, from which aerosol absorption is derived, at relative humidities up to ~90%. The modified instrument is referred to as the humidified CAPS (HCAPS). Additionally, we develop and validate an update to a method to calculate the truncation correction factor, used to correct the scattering measurements, that can account for the effects of particle growth and compositional changes resulting from water uptake. The method can be applied to experiments that use either size-selected or polydisperse aerosol samples of either known or unknown composition. Overall, we show that measurements made with the HCAPS, when processed using the updated truncation correction method, enable accurate measurement of the influence of water uptake on light absorption.

Dal Porto, Rachael [University of California, Davi↗

Toward closure between predicted and observed particle viscosity over a wide range of temperatures and relative humidity

Abstract. Atmospheric aerosols can exist in amorphous semi-solid or glassy phase states whose viscosity varies with atmospheric temperature and relative humidity. The temperature and humidity dependence of viscosity has been hypothesized to be predictable from the combination of a water–organic binary mixing rule of the glass transition temperature, a glass-transition-temperature-scaled viscosity fragility parameterization, and a water uptake parameterization. This work presents a closure study between predicted and observed viscosity for sucrose and citric acid. Viscosity and glass transition temperature as a function of water content are compiled from literature data and used to constrain the fragility parameterization. New measurements characterizing viscosity of sub-100 nm particles using the dimer relaxation method are presented. These measurements extend the available data of temperature- and humidity-dependent viscosity to −28 ∘C. Predicted relationships agree well with observations at room temperature and with measured isopleths of constant viscosity at ∼107 Pa s at temperatures warmer than −28 ∘C. Discrepancies at colder temperatures are observed for sucrose particles. Simulations with the kinetic multi-layer model of gas–particle interactions suggest that the observed deviations at colder temperature for sucrose can be attributed to kinetic limitations associated with water uptake at the timescales of the dimer relaxation experiments. Using the available information, updated equilibrium phase-state diagrams (-80∘C

54 ENVIRONMENTAL SCIENCES↗

A Water-Resistant Hydrogen-Bonded Organic Framework for Ethane/Ethylene Separation in Humid Environments

The separation of ethane (C 2 H 6 ) and ethylene (C 2 H 4 ) represents a crucial process for the production of polymer-grade C 2 H 4 , and adsorptive separation holds enormous promise for this industrially important but challenging task. Furthermore we report a new hydrogen-bonded organic frameworks (HIAM-102) with suitable channel and superhydrophobicity for preferential adsorption of C 2 H 6 over C 2 H 4 . HIAM-102 shows a C 2 H 6 /C 2 H 4 IAST selectivity of 1.9 and C 2 H 6 uptake of 48.25 cm 3 /g at 1 bar and 298 K. Benefitted from the hydrophobic pore surface, it can well-separate C 2 H 6 and C 2 H 4 under highly humid conditions as confirmed by experimental column breakthrough measurements. Computational calculations provide additional support for the experimental observations that the nonpolar channel of HIAM-102 interact favorably with C 2 H 6 over C 2 H 4 .

36 MATERIALS SCIENCE↗