Search NASA⌕ Search

SEARCH · Search NASA

Results for “hybrid programming model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Influence of Business Models on PV-Battery Dispatch Decisions and Market Value

PV-battery hybrid projects dominate interconnection queues in some regions in the United States, but few projects have been operational long enough to assess how the hybrid capabilities may be used in practice. We interview plant operators and analyze empirical dispatch data for eleven large-scale PV-battery hybrids in three organized wholesale markets in the United States. We use the dispatch data and wholesale market prices to estimate the market value of our sample hybrids in 2020. The empirical increase in market value of a PV-battery hybrid relative to a standalone PV plant varies by project and ranges from $\$$1 to $\$$48/MWhsolar. The premium is driven by market, location, technical characteristics of the PV and battery asset, and battery dispatch strategies. In contrast to the widespread assumptions in the PV-battery hybrid modeling literature, only three of the eleven project operators optimize battery usage for wholesale market revenue as merchant plants. Instead, the majority of operators in the sample have alternate objectives. For example, load-serving entities target peak load reductions, incentive program participants focus on compliance with program requirements, and large energy consumers prioritize resiliency and utility bill minimization. Understanding prevalent dispatch signals and the degree of alignment with system-wide grid needs can increase the market value of PV-battery hybrids.

14 SOLAR ENERGY↗

Quantum computing based hybrid solution strategies for large-scale discrete-continuous optimization problems

Quantum computing (QC) has gained popularity due to its unique capabilities that are quite different from that of classical computers in terms of speed and methods of operations. This paper proposes hybrid models and methods that effectively leverage the complementary strengths of deterministic algorithms and QC techniques to overcome combinatorial complexity for solving large-scale mixed-integer programming problems. Four applications, namely the molecular conformation problem, job-shop scheduling problem, manufacturing cell formation problem, and the vehicle routing problem, are specifically addressed. Large-scale instances of these application problems across multiple scales ranging from molecular design to logistics optimization are computationally challenging for deterministic optimization algorithms on classical computers. To address the computational challenges, hybrid QC-based algorithms are proposed and extensive computational experimental results are presented to demonstrate their applicability and efficiency. The proposed QC-based solution strategies enjoy high computational efficiency in terms of solution quality and computation time, by utilizing the unique features of both classical and quantum computers.

97 MATHEMATICS AND COMPUTING↗

High Efficiency Power Combining of Ka-Band TWTs for High Data Rate Communications

Future NASA deep space exploration missions are expected in some cases to require telecommunication systems capable of operating at very high data rates (potentially 1 Gbps or more) for the transmission back to Earth of large volumes of scientific data, which means high frequency transmitters with large bandwidth. Among the Ka band frequencies of interest are the present 500 MHz Deep Space Network (DSN) band of 31.8 to 32.3 GHz and a broader band at 37-38 GHz allocated for space science [1]. The large distances and use of practical antenna sizes dictate the need for high transmitter power of up to 1 kW or more. High electrical efficiency is also a requirement. The approach investigated by NASA GRC is a novel wave guide power combiner architecture based on a hybrid magic-T junction for combining the power output from multiple TWTs [1,2]. This architecture was successfully demonstrated and is capable of both high efficiency (90-95%, depending on frequency) and high data rate transmission (up to 622 Mbps) in a two-way power combiner circuit for two different pairs of Ka band TWTs at two different frequency bands. One pair of TWTs, tested over a frequency range of 29.1 to 29.6 GHz, consisted of two 110-115W TWTs previously used in uplink data transmission evaluation terminals in the NASA Advanced Communications Technology Satellite (ACTS) program [1,2]. The second pair was two 100W TWTs (Boeing 999H) designed for high efficiency operation (greater than 55%) over the DSN frequency band of 31.8 to 32.3 GHz [3]. The presentation will provide a qualitative description of the wave guide circuit, results for power combining and data transmission measurements, and results of computer modeling of the magic-T and alternative hybrid junctions for improvements in efficiency and power handling capability. The power combiner results presented here are relevant not only to NASA deep space exploration missions, but also to other U.S. Government agency programs.

Wintucky, E. G.↗

Optimal design and dispatch of a system of diesel generators, photovoltaics and batteries for remote locations

Renewable energy technologies, specifically, solar photovoltaic cells, combined with battery storage and diesel generators, form a hybrid system capable of independently powering remote locations, i.e., those isolated from larger grids. If sized correctly, hybrid systems reduce fuel consumption compared to diesel generator-only alternatives. We present an optimization model for establishing a hybrid power design and dispatch strategy for remote locations, such as a military forward operating base, that models the acquisition of different power technologies as integer variables and their operation using nonlinear expressions. Our cost-minimizing, nonconvex, mixed-integer, nonlinear program contains a detailed battery model. Due to its complexities, we present linearizations, which include exact and convex under-estimation techniques, and a heuristic, which determines an initial feasible solution to serve as a “warm start” for the solver. We determine, in a few hours at most, solutions within 5% of optimality for a candidate set of technologies; these solutions closely resemble those from the nonlinear model. Lastly, our instances contain real data spanning a yearly horizon at hour fidelity and demonstrate that a hybrid system could reduce fuel consumption by as much as 50% compared to a generator-only solution.

14 SOLAR ENERGY↗

Incident Energy Systems Model: User Guide and Examples

U.S. Forest Service (USFS) wildfire base camps use portable power for electrical needs, including yurts and trailers from which logistics staff work during the incident. These yurts and trailers are conventionally powered by portable diesel generators. Hybrid portable power systems consisting of a combination of solar photovoltaics (PV), battery energy storage systems (BESS), and/or backup diesel generators have been used in recent years and were piloted by the National Technology and Development Program (NTDP) on incidents in fall 2024 as part of NTDP's Portable Power Project. As part of that project, this work included the development of two Excel-based tools and two reports explaining the tools. The first tool, the Incident Energy Systems Model, is an Excel-based tool that models the power output of hybrid portable power systems powering yurts and/or trailers at fire camps over a typical day.

14 SOLAR ENERGY↗

Hybrid EMT-TS Simulation Strategies to Study High Bandwidth MMC-Based HVdc Systems

Modular multilevel converters (MMCs) are widely used in the design of modern high-voltage direct current (HVdc) transmission system. High-fidelity dynamic models of MMCs-based HVdc system require small simulation time step and can be accurately modeled in electro-magnetic transient (EMT) simulation programs. The EMT program exhibits slow simulation speed and limitation on the size of the model and brings certain challenges to test the high-fidelity HVdc model in system-level simulations. This paper presents the design and implementation of a hybrid simulation framework, which enables the co-simulation of the EMT model of Atlanta-Orlando HVdc line and the transient stability (TS) model of the entire Eastern Interconnection system. This paper also introduces the implementation of two high-fidelity HVdc line models simulated at different time steps and discusses a dedicated method for sizing the buffer areas on both sides of the HVdc line. The simulation results of the two HVdc models with different sizes of buffer areas are presented and compared.

Liu, Yuan↗

Parallel Unsteady Turbopump Simulations for Liquid Rocket Engines

This paper reports the progress being made towards complete turbo-pump simulation capability for liquid rocket engines. Space Shuttle Main Engine (SSME) turbo-pump impeller is used as a test case for the performance evaluation of the MPI and hybrid MPI/Open-MP versions of the INS3D code. Then, a computational model of a turbo-pump has been developed for the shuttle upgrade program. Relative motion of the grid system for rotor-stator interaction was obtained by employing overset grid techniques. Time-accuracy of the scheme has been evaluated by using simple test cases. Unsteady computations for SSME turbo-pump, which contains 136 zones with 35 Million grid points, are currently underway on Origin 2000 systems at NASA Ames Research Center. Results from time-accurate simulations with moving boundary capability, and the performance of the parallel versions of the code will be presented in the final paper.

Kiris, Cetin C.↗

Cascade Solar Cell Workshop report

Issues related to the feasibility, research and development, and demonstration of a 30% AMO cascade solar cell discussed include the material selection, growth and fabrication techniques, and device development strategy for a monolithic (two terminal) cascade cell, a hybrid (four terminal) cascade cell, and a spectral splitting device (three cells). Workshop recommendations include: (1) initiate a long range research program to develop a three junction, monolithic, cascade cell using either AlGaAsSb-GaAsSb or AlGaInAs-GaInAs material system; (2) emphasize OM-CVD epitaxial growth technique, perhaps combined with other technologies in the near term to obtain tunnel junctions; (3) develop a two junction device first; (4) initiate a cascade solar cell modeling program to study and compare performance of two and four terminal cascade devices exposed to electron and proton irradiation; and (5) encourage and be open to new ideas for developing four terminal, hybrid, cascade cells exploiting novel component cell interconnect technologies.

Hutchby, J. A.↗

Dispatch optimization of concentrating solar power with utility-scale photovoltaics

Concentrating solar power (CSP) tower technologies capture thermal radiation from the sun utilizing a field of solar-tracking heliostats. When paired with inexpensive thermal energy storage (TES), CSP technologies can dispatch electricity during peak-market-priced hours, day or night. The cost of utility-scale photovoltaic (PV) systems has dropped significantly in the last decade, resulting in inexpensive energy production during daylight hours. The hybridization of PV and CSP with TES systems has the potential to provide continuous and stable energy production at a lower cost than a PV or CSP system alone. Hybrid systems are gaining popularity in international markets as a means to increase renewable energy portfolios across the world. Typically, CSP-PV hybrid systems have been evaluated using either monthly averages of hourly PV production or scheduling algorithms that neglect the time-of-production value of electricity in the market. To more accurately evaluate a CSP-PV-battery hybrid design, we develop a profit-maximizing mixed-integer linear program ($\mathcal{H}$) that determines a dispatch schedule for the individual sub-systems with a sub-hourly time fidelity. We introduce the mathematical formulation of such a model and show that it is computationally expensive to solve. To improve model tractability and reduce solution times, we offer techniques that: (1) reduce the problem size, (2) tighten the linear programming relaxation of ($\mathcal{H}$) via reformulation and the introduction of cuts, and (3) implement an optimization-based heuristic (that can yield initial feasible solutions for (($\mathcal{H}$) and, at any rate, yields near-optimal solutions). Applying these solution techniques results in a 79% improvement in solve time, on average, for our 48-h instances of (($\mathcal{H}$); corresponding solution times for an annual model run decrease by as much as 93%, where such a run consists of solving 365 instances of (($\mathcal{H}$), retaining only the first 24 h' worth of the solution, and sliding the time window forward 24 h. We present annual system metrics for two locations and two markets that inform design practices for hybrid systems and lay the groundwork for a more exhaustive policy analysis. A comparison of alternative hybrid systems to the CSP-only system reflects that hybrid models can almost double capacity factors while resulting in a 30% improvement related to various economic metrics.

14 SOLAR ENERGY↗

Safety Verification of a Fault Tolerant Reconfigurable Autonomous Goal-Based Robotic Control System

Fault tolerance and safety verification of control systems are essential for the success of autonomous robotic systems. A control architecture called Mission Data System (MDS), developed at the Jet Propulsion Laboratory, takes a goal-based control approach. In this paper, a method for converting goal network control programs into linear hybrid systems is developed. The linear hybrid system can then be verified for safety in the presence of failures using existing symbolic model checkers. An example task is simulated in MDS and successfully verified using HyTech, a symbolic model checking software for linear hybrid systems.

goal network↗

Co-design optimization of combined heat and power-based microgrids

With the emergent need for clean and reliable energy resources, hybrid energy systems, such as the microgrid, are widely adopted in the United States. A microgrid can consist of various distributed energy resources, for instance, combined heat and power (CHP) systems. Here, the CHP module is a distributed cogeneration technology that produces electricity and recaptures heat generated as a by-product. It is an energy-efficient technology converting heat that would otherwise be wasted to valuable thermal energy. For an optimal system configuration, this study develops a novel co-design optimization framework for CHP-based cogeneration microgrids. The framework provides the stakeholder with a method to optimize investments and attain resilient operations. The proposed co-design framework has a mixed integer programming (MIP) model that outputs decisions for both plant designs and operating controls. The microgrid considered in this study contains six components: the CHP, boiler, heat recovery unit, thermal storage system, power storage system, and photovoltaic plant. After solving the MIP model, the optimal design parameters of each component can be found to minimize the total installation cost of all components in the microgrid. Furthermore, the online costs from energy production, operation, maintenance, machine startup, and disruption-induced unsatisfied loads are minimized by solving the optimal control decisions for operations. Case studies based on designing a CHP-based microgrid with empirical data are conducted. Moreover, we consider both nominal and disruptive operational scenarios to validate the performance of the proposed co-design framework in terms of a cost-effective, resilient system.

42 ENGINEERING↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Real-time hybrid computer simulation of a small turboshaft engine and control system

The development of an analytical model of a small turboshaft engine designed for helicopter propulsion systems is described. The model equations were implemented on a hybrid computer system to provide a real time nonlinear simulation of the engine performance over a wide operating range. The real time hybrid simulation of the engine was used to evaluate a microprocessor based digital control module. This digital control module was developed as part of an advanced rotorcraft control program. After tests with the hybrid engine simulation the digital control module was used to control a real engine in an experimental program. A hybrid simulation of the engine's electrical hydromechanical control system was developed. This allowed to vary the fuel flow and torque load inputs to the hybrid engine simulation for simulating transient operation. A steady-state data and the experimental tests are compared. Analytical model equations, analog computer diagrams, and a digital computer flow chart are included.

Hart, C. E.↗

A Formal Verification Framework for Runtime Assurance

The simplex architecture is an instance of Runtime Assurance (RTA) where a trusted component takes control of a safety-critical system when an untrusted component violates a safety property. This paper presents a formalization of the simplex RTA framework in the language of hybrid programs. A feature of this formal verification framework is that, for a given system, a specific instantiation can be created and its safety properties are guaranteed by construction. Instantiations may be kept at varying levels of generality, allowing for black box components, such as ML/AI-based controllers, to be modeled. The framework is written in the Prototype Verification System (PVS) using Plaidypvs, an embedding of differential dynamic logic in PVS. As a proof of concept, the framework is illustrated on an automatic vehicle braking system.

Runtime assurance↗

A Formal Verification Framework for Runtime Assurance

The simplex architecture is an instance of Runtime Assurance (RTA) where a trusted component takes control of a safety-critical system when an untrusted component violates a safety property. This paper presents a formalization of the simplex RTA framework in the language of hybrid programs. A feature of this formal verification framework is that, for a given system, a specific instantiation can be created and its safety properties are guaranteed by construction. Instantiations may be kept at varying levels of generality, allowing for black box components, such as ML/AI-based controllers, to be modeled. The framework is written in the Prototype Verification System (PVS) using Plaidypvs, an embedding of differential dynamic logic in PVS. As a proof of concept, the framework is illustrated on an automatic vehicle braking system.

Runtime assurance↗

An automated procedure for calculating system matrices from perturbation data generated by an EAI Pacer and 100 hybrid computer system

Techniques are presented for determining the elements of the A, B, C, and D state variable matrices for systems simulated on an EAI Pacer 100 hybrid computer. An automated procedure systematically generates disturbance data necessary to linearize the simulation model and stores these data on a floppy disk. A separate digital program verifies this data, calculates the elements of the system matrices, and prints these matrices appropriately labeled. The partial derivatives forming the elements of the state variable matrices are approximated by finite difference calculations.

Milner, E. J.↗

Joint Optimization of Multimodal Transit Frequency and Shared Autonomous Vehicle Fleet Size with Hybrid Metaheuristic and Nonlinear Programming

Shared autonomous vehicles (SAVs) bring competition to traditional transit services but redesigning multimodal transit network can utilize SAVs as feeders to enhance service efficiency and coverage. This paper presents an optimization framework for the joint multimodal transit frequency and SAV fleet size problem, a variant of the transit network frequency setting problem. The objective is to maximize total transit ridership (including SAV-fed trips and subtracting boarding rejections) across multiple time periods under budget constraints, considering endogenous mode choice (transit, point-to-point SAVs, driving) and route selection, while allowing for strategic route removal by setting frequencies to zero. Due to the problem’s non-linear, non-convex nature and the computational challenges of large-scale networks, we develop a hybrid solution approach that combines a metaheuristic approach (particle swarm optimization) with nonlinear programming for local solution refinement. To ensure computational tractability, the framework integrates analytical approximation models for SAV waiting times based on fleet utilization, multimodal network assignment for route choice, and multinomial logit mode choice behavior, bypassing the need for computationally intensive simulations within the main optimization loop. Applied to the Chicago metropolitan area’s multimodal network, our method illustrates a 33.3% increase in transit ridership through optimized transit route frequencies and SAV integration, particularly enhancing off-peak service accessibility and strategically reallocating resources.

Ng, Max↗