Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-F-T-685: Evaluation of Tumor Hypoxic Fraction Using Serial Volumetric Imaging During Radiation Therapy

Purpose: To develop a tumor response model which could be uses to compute tumor hypoxic fraction using serial volumetric tumor imaging. This algorithm may be used for treatment response assessment and also for guidance of more expensive PET imaging of hypoxia. Methods: Previously developed two-level cell population tumor response model was modified to include a third cell level describing hypoxic and necrotic cells. This third level was considered constant value during radiotherapy treatment; therefore, inclusion additional parameter did not compromise stability of model fitting to imaging data. Fitting the model to serial volumetric imaging data was performed using a least squares objective function and simulated annealing algorithm. The problem of reconstruction of radiobiological parameters from serial imaging data was considered as inverse ill-posed problem described by the Fredholm integral equation of the first kind. Variational regularization was used to stabilize solutions. Results: To evaluate performance of the algorithm, we used a set of serial CT imaging data on tumor-volume for 14 head and neck cancer patients. The hypoxic fractions were reconstructed for each patient and the distribution of hypoxic fractions was compared to the distribution of initial hypoxic fractions previously measured using histograph. The measured and reconstructed from imaging data distributions of hypoxic fractions are in good agreement. The reconstructed distribution of cell surviving fraction was also in better agreement with in vitro data than previously obtained using the two-level cell population model. Conclusion: Our results indicate that it is possible to evaluate the initial hypoxic tumor fraction using serial volumetric imaging and a tumor response model. This algorithm can be used for treatment response assessment and guidance of more expensive PET imaging.

60 APPLIED LIFE SCIENCES↗

Biological material fouling assessment systems and methods

Biological material fouling assessment systems and methods are described. According to one aspect, a biological material fouling assessment system includes processing circuitry configured to access image data of an image of a surface of a substrate which has been fouled with biological material, wherein the image data comprises intensity information regarding a plurality of pixels of the image, and wherein the processing circuitry is further configured to process the intensity information regarding the pixels of the image to generate information which is indicative of an amount of the fouling of the biological material upon the surface of the substrate.

42 ENGINEERING↗

Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t-test. Results: The mean TRE (and standard deviation) was 0.6 ± 0.7 mm (smaller than the voxel dimension) for DIR between pre contrast and postcontrast end-inspiratory CT image data sets. No singularities were observed in the displacement vector fields. The mean HU enhancement (and standard deviation) was 37.3 ± 10.5 HU for normal lung subjects and 30.7 ± 13.5 HU for diseased lung subjects. Spatial heterogeneity of regional perfusion was found to be higher for diseased lung subjects than for normal lung subjects, i.e., a mean coefficient of variation of 2.06 vs 1.59 (p = 0.07). The average gravitationally directed gradient was strong and significant (R{sup 2} = 0.99, p < 0.01) for normal lung dogs, whereas it was moderate and nonsignificant (R{sup 2} = 0.61, p = 0.12) for diseased lung dogs. Conclusions: This canine study demonstrated the accuracy of DIR with subvoxel TREs on average, higher spatial heterogeneity of regional perfusion for diseased lung subjects than for normal lung subjects, and a strong gravitationally directed gradient for normal lung subjects, providing proof-of-principle for single-energy CT pulmonary perfusion imaging. Further studies such as comparison with other perfusion imaging modalities will be necessary to validate the physiological significance.

60 APPLIED LIFE SCIENCES↗

Quality Assurance of Positron Emission Tomography/Computed Tomography for Radiation Therapy

Recent advances in radiation delivery techniques, such as intensity-modulated radiation therapy, provide unprecedented ability to exquisitely control three-dimensional dose distribution. Development of on-board imaging and other image-guidance methods significantly improved our ability to better target a radiation beam to the tumor volume. However, in reality, accurate definition of the location and boundary of the tumor target is still problematic. Biologic and physiologic imaging promises to solve the problem in a fundamental way and has a more and more important role in patient staging, treatment planning, and therapeutic assessment in radiation therapy clinics. The last decade witnessed a dramatic increase in the use of positron emission tomography and computed tomography in radiotherapy practice. To ensure safe and effective use of nuclide imaging, a rigorous quality assurance (QA) protocol of the imaging tools and integration of the imaging data must be in place. The application of nuclide imaging in radiation oncology occurs at different levels of sophistication. Quantitative use of the imaging data in treatment planning through image registration and standardized uptake value calculation is often involved. Thus, QA should not be limited to the performance of the scanner, but should also include the process of implementing image data in treatment planning, such as data transfer, image registration, and quantitation of data for delineation of tumors and sensitive structures. This presentation discusses various aspects of nuclide imaging as applied to radiotherapy and describes the QA procedures necessary for the success of biologic image-guided radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Method of processing an image

A non-transitory computer-readable medium encoded with a computer-readable program, which when executed by a processor, will cause a computer to execute a computational method, the computational method including collecting an image data, wherein the collecting the image data comprises collecting a first plurality of RGB images and a second plurality of hyperspectral images. The method further includes orthorectifying the image data to produce an RGB based orthophoto and a partially rectified hyperspectral orthophoto. The method further includes selecting tie features from each of the RGB based orthophoto and the partially rectified hyperspectral orthophoto. Lastly, the method includes registering the features of the partially rectified hyperspectral orthophoto into the tie features of the RGB based orthophoto.

97 MATHEMATICS AND COMPUTING↗

Method of processing an image

A non-transitory computer-readable medium encoded with a computer-readable program, which when executed by a processor, will cause a computer to execute a computational method, the computational method including collecting an image data, wherein the collecting the image data comprises collecting a first plurality of RGB images and a second plurality of hyperspectral images. The method further includes orthorectifying the image data to produce an RGB based orthophoto and a partially rectified hyperspectral orthophoto. The method further includes selecting tie features from each of the RGB based orthophoto and the partially rectified hyperspectral orthophoto. Lastly, the method includes registering the features of the partially rectified hyperspectral orthophoto into the tie features of the RGB based orthophoto.

97 MATHEMATICS AND COMPUTING↗

Method of processing an image

A non-transitory computer-readable medium encoded with a computer-readable program, which when executed by a processor, will cause a computer to execute a computational method, the computational method including collecting an image data, wherein the collecting the image data comprises collecting a first plurality of RGB images and a second plurality of hyperspectral images. The method further includes orthorectifying the image data to produce an RGB based orthophoto and a partially rectified hyperspectral orthophoto. The method further includes selecting tie features from each of the RGB based orthophoto and the partially rectified hyperspectral orthophoto. Lastly, the method includes registering the features of the partially rectified hyperspectral orthophoto into the tie features of the RGB based orthophoto.

97 MATHEMATICS AND COMPUTING↗

Measuring Regional Changes in the Diastolic Deformation of the Left Ventricle of SHR Rats Using microPET Technology and Hyperelastic Warping

The objective of this research was to assess applicability of a technique known as hyperelastic warping for the measurement of local strains in the left ventricle (LV) directly from microPET image data sets. The technique uses differences in image intensities between template (reference) and target (loaded) image data sets to generate a body force that deforms a finite element (FE) representation of the template so that it registers with the target images. For validation, the template image was defined as the end-systolic microPET image data set from a Wistar Kyoto (WKY) rat. The target image was created by mapping the template image using the deformation results obtained from a FE model of diastolic filling. Regression analysis revealed highly significant correlations between the simulated forward FE solution and image derived warping predictions for fiber stretch (R2 = 0.96), circumferential strain (R2 = 0.96), radial strain (R2 = 0.93), and longitudinal strain (R2 = 0.76) (p<0.001for all cases). The technology was applied to microPET image data of two spontaneously hypertensive rats (SHR) and a WKY control. Regional analysis revealed that, the lateral freewall in the SHR subjects showed the greatest deformation compared with the other wall segments. This work indicates that warping can accurately predict the strain distributions during diastole from the analysis of microPET data sets.

42 ENGINEERING↗

Correcting incompatible DN values and geometric errors in nighttime lights time series images

The Defense Meteorological Satellite Program’s Operational Linescan System (DMSP-OLS) nighttime lights imagery has proven to be a powerful remote sensing tool to monitor urbanization and assess socioeconomic activities at large scales. However, the existence of incompatible digital number (DN) values and geometric errors severely limit application of nighttime light image data on multi-year quantitative research. In this study we extend and improve previous studies on inter-calibrating nighttime lights image data to obtain more compatible and reliable nighttime lights time series (NLT) image data for China and the United States (US) through four steps: inter-calibration, geometric correction, steady increase adjustment, and population data correction. We then use gross domestic product (GDP) data to test the processed NLT image data indirectly and find that sum light (summed DN value of pixels in a nighttime light image) maintains apparent increase trends with relatively large GDP growth rates but does not increase or decrease with relatively small GDP growth rates. As nighttime light is a sensitive indicator for economic activity, the temporally consistent trends between sum light and GDP growth rate imply that brightness of nighttime lights on the ground is correctly represented by the processed NLT image data. Finally, through analyzing the corrected NLT image data from 1992 to 2008, we find that China experienced apparent nighttime lights development in 1992-1997 and 2001-2008 respectively and the US suffered from nighttime lights decay in large areas after 2001.

47 OTHER INSTRUMENTATION↗

Image segmentation for uranium isotopic analysis by SIMS: Combined adaptive thresholding and marker controlled watershed approach

A novel approach to particle identification and particle isotope ratio determination has been developed for nuclear safeguard applications. This particle search approach combines an adaptive thresholding algorithm and marker-controlled watershed segmentation (MCWS) transform, which improves the secondary ion mass spectrometry (SIMS) isotopic analysis of uranium containing particle populations for nuclear safeguards applications. The Niblack assisted MCWS approach (a.k.a. SEEKER) developed for this work has improved the identification of isotopically unique uranium particles under conditions that have historically presented significant challenges for SIMS image data processing techniques. Particles obtained from five NIST uranium certified reference materials (CRM U129A, U015, U150, U500 and U850) were successfully identified in regions of SIMS image data 1) where a high variability in image intensity existed, 2) where particles were touching or were in close proximity to one another and/or 3) where the magnitude of ion signal for a given region was count limited. Analysis of the isotopic distributions of uranium containing particles identified by SEEKER showed four distinct, accurately identified 235U enrichment distributions, corresponding to the NIST certified 235U/238U isotope ratios for CRM U129A/U015 (not statistically differentiated), U150, U500 and U850. Additionally, comparison of the minor uranium isotope (234U, 235U and 236U) atom percent values verified that, even in the absence of high precision isotope ratio measurements, SEEKER could be used to segment isotopically unique uranium particles from SIMS image data. Although demonstrated specifically for SIMS analysis of uranium containing particles for nuclear safeguards, SEEKER has application in addressing a broad set of image processing challenges.

adaptive thresholding↗

Dual modality endocavity biopsy imaging system and method

A dual modality endocavity imaging and treatment system for detection of cancer and targeted biopsy and treatment procedures, comprising: a housing; a nuclear detector system housed within the housing and configured for detecting nuclear radiation imaging data; an ultrasound detector system housed within the housing for detecting ultrasound imaging data; a needle associated with the housing and adjustably positionable relative thereto; and a data processing module configured to receive the nuclear radiation imaging data and the ultrasound imaging data and to generate and output an image showing the relative position of the needle and an endocavity object of interest. The needle may include a distinct radiation signature to facilitate imaging thereof.

Lall, Terrence↗

Nuclear imaging of the fuel assembly in ignition experiments

First results from the analysis of neutron image data collected on implosions of cryogenically layered deuterium-tritium capsules during the 2011-2012 National Ignition Campaign are reported. The data span a variety of experimental designs aimed at increasing the stagnation pressure of the central hotspot and areal density of the surrounding fuel assembly. Images of neutrons produced by deuterium–tritium fusion reactions in the hotspot are presented, as well as images of neutrons that scatter in the surrounding dense fuel assembly. The image data are compared with 1D and 2D model predictions, and consistency checked using other diagnostic data. The results indicate that the size of the fusing hotspot is consistent with the model predictions, as well as other imaging data, while the overall size of the fuel assembly, inferred from the scattered neutron images, is systematically smaller than models' prediction. Preliminary studies indicate these differences are consistent with a significant fraction (20%–25%) of the initial deuterium-tritium fuel mass outside the compact fuel assembly, due either to low mode mass asymmetry or high mode 3D mix effects at the ablator-ice interface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlator convolutional neural networks as an interpretable architecture for image-like quantum matter data

Image-like data from quantum systems promises to offer greater insight into the physics of correlated quantum matter. However, the traditional framework of condensed matter physics lacks principled approaches for analyzing such data. Machine learning models are a powerful theoretical tool for analyzing image-like data including many-body snapshots from quantum simulators. Recently, they have successfully distinguished between simulated snapshots that are indistinguishable from one and two point correlation functions. Thus far, the complexity of these models has inhibited new physical insights from such approaches. Here, we develop a set of nonlinearities for use in a neural network architecture that discovers features in the data which are directly interpretable in terms of physical observables. Applied to simulated snapshots produced by two candidate theories approximating the doped Fermi-Hubbard model, we uncover that the key distinguishing features are fourth-order spin-charge correlators. Our approach lends itself well to the construction of simple, versatile, end-to-end interpretable architectures, thus paving the way for new physical insights from machine learning studies of experimental and numerical data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

rapidMCR

rapidMCR is a user friendly software package that includes automatic preprocessing, analysis, and viewing of hyperspectral image data sets. Currently, this software package specifically preprocesses and analyzes hyperspectral fluorescence image data sets that have been created on Sandia hyperspectral imaging microscopes; however, this software can be modified to include spectroscopic image data sets from other (non-Sandia developed) instruments as well. This software relies on using prior information about the spectroscopic image data sets by conducting a rigorous characterization of the instrument. By characterizing the instrument for noise and artifacts, we can implement our algorithms to account for the effects specific to a particular instrument. This allows us to automate the data preprocessing while improving the analysis results.

Source record↗

Extracting the Data From the LCM vk4 Formatted Output File

These are slides about extracting the data from the LCM vk4 formatted output file. The following is covered: vk4 file produced by Keyence VK Software, custom analysis, no off the shelf way to read the file, reading the binary data in a vk4 file, various offsets in decimal lines, finding the height image data, directly in MATLAB, binary output beginning of height image data, color image information, color image binary data, color image decimal and binary data, MATLAB code to read vk4 file (choose a file, read the file, compute offsets, read optical image, laser optical image, read and compute laser intensity image, read height image, timing, display height image, display laser intensity image, display RGB laser optical images, display RGB optical images, display beginning data and save images to workspace, gamma correction subroutine), reading intensity form the vk4 file, linear in the low range, linear in the high range, gamma correction for vk4 files, computing the gamma intensity correction, observations.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

DYNAMICS IN SUNSPOT UMBRA AS SEEN IN NEW SOLAR TELESCOPE AND INTERFACE REGION IMAGING SPECTROGRAPH DATA

We analyze sunspot oscillations using Interface Region Imaging Spectrograph (IRIS) slit-jaw and spectral data and narrow-band chromospheric images from the New Solar Telescope (NST) for the main sunspot in NOAA AR 11836. We report that the difference between the shock arrival times as measured by the Mg II k 2796.35 Å and Si IV 1393.76 Å line formation levels changes during the observed period, and peak-to-peak delays may range from 40 s to zero. The intensity of chromospheric shocks also displays long-term (about 20 min) variations. NST's high spatial resolution Hα data allowed us to conclude that, in this sunspot, umbral flashes (UFs) appeared in the form of narrow bright lanes stretched along the light bridges and around clusters of umbral bright points. The time series also suggested that UFs preferred to appear on the sunspot-center side of light bridges, which may indicate the existence of a compact sub-photospheric driver of sunspot oscillations. The sunspot's umbra as seen in the IRIS chromospheric and transition region data appears bright above the locations of light bridges and the areas where the dark umbra is dotted with clusters of umbral dots. Co-spatial and co-temporal data from the Atmospheric Imaging Assembly on board the Solar Dynamics Observatory showed that the same locations were associated with bright footpoints of coronal loops suggesting that the light bridges may play an important role in heating the coronal sunspot loops. Finally, the power spectra analysis showed that the intensity of chromospheric and transition region oscillations significantly vary across the umbra and with height, suggesting that umbral non-uniformities and the structure of sunspot magnetic fields may play a role in wave propagation and heating of umbral loops.

79 ASTRONOMY AND ASTROPHYSICS↗

Removing imaging systematics from galaxy clustering measurements with Obiwan: application to the SDSS-IV extended Baryon Oscillation Spectroscopic Survey emission-line galaxy sample

This article presents the application of a new tool, Obiwan, which uses image simulations to determine the selection function of a galaxy redshift survey and calculate three-dimensional (3D) clustering statistics. Obiwan relies on a forward model of the process by which images of the night sky are transformed into a 3D large-scale structure catalogue, and offers several advantages over more traditional map-based techniques – such as operating on individual exposures and adopting a maximum likelihood approach. The photometric pipeline automatically detects and models galaxies and then generates a catalogue of such galaxies with detailed information for each one of them, including their location, redshift, and so on. Systematic biases in the imaging data are therefore imparted into the catalogues and must be accounted for in any scientific analysis of their information content. Obiwan simulates this process for samples selected from the Legacy Surveys imaging data. This imaging data will be used to select target samples for the next-generation Dark Energy Spectroscopic Instrument (DESI) experiment. Here, we apply Obiwan to a portion of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey emission-line galaxies (ELGs). Systematic biases in the data are clearly identified and removed. We compare the 3D clustering results to those obtained by the map-based approach applied to the complete eBOSS Data Release 16 (DR16) sample. We find the results are consistent, thereby validating the eBOSS DR16 ELG catalogues, which is used to obtain cosmological results.

79 ASTRONOMY AND ASTROPHYSICS↗