Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Integrative Quantitative-Phase and Airy Light-Sheet Imaging

Light-sheet microscopy enables considerable speed and phototoxicity gains, while quantitative-phase imaging confers label-free organelle recognition and metabolic information that are inaccessible by conventional methods. We report the fusion of these two modalities onto a standard inverted microscope that retains compatibility with microfluidics. We describe the utilization of an accelerating Airy-beam light-sheet yielding identical imaging areas with interferometry, and an application in unmasking the effects of cellular noise on metabolic compartmentalization.

Biological sciences, Biological techniques, Micros↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

The State of the Art in Root System Architecture Image Analysis Using Artificial Intelligence: A Review

Roots are essential for acquiring water and nutrients to sustain and support plant growth and anchorage. However, they have been studied less than the aboveground traits in phenotyping and plant breeding until recent decades. In modern times, root properties such as morphology and root system architecture (RSA) have been recognized as increasingly important traits for creating more and higher quality food in the “Second Green Revolution”. To address the paucity in RSA and other root research, new technologies are being investigated to fill the increasing demand to improve plants via root traits and overcome currently stagnated genetic progress in stable yields. Artificial intelligence (AI) is now a cutting-edge technology proving to be highly successful in many applications, such as crop science and genetic research to improve crop traits. A burgeoning field in crop science is the application of AI to high-resolution imagery in analyses that aim to answer questions related to crops and to better and more speedily breed desired plant traits such as RSA into new cultivars. This review is a synopsis concerning the origins, applications, challenges, and future directions of RSA research regarding image analyses using AI.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-element metasurface system for imaging in the near-infrared

Metasurfaces are optically thin 2D arrays of subwavelength scatterers that modify scalar and vector properties of incident electromagnetic fields. Metasurface lenses are of particular interest for imaging applications for their flat form factor, compatibility with CMOS fabrication processes, and potential for correcting aberrations with a small number of elements. Here, we advance this capability by realizing a millimeter-diameter, polarization-independent metalens triplet system with chromatic aberration correction over the wavelength range of 1.30–1.60 μm and monochromatic aberration correction enabling a field of view of 50°.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Event-Driven 3D Sensing Architecture

Some events happen too quickly to capture twice. Whether tracking satellites, monitoring aircraft, observing autonomous systems, or recording high speed industrial processes, imaging systems often have only one opportunity to collect the right information. If a camera is focused on the wrong distance, uses the wrong exposure, or cannot keep pace with rapid motion, important details may be lost forever. Los Alamos National Laboratory has developed an event-driven imaging architecture that preserves more information during data collection than a conventional camera. Instead of committing to a single image, the system captures data that can later be used to digitally adjust focus and exposure while reconstructing the scene in three dimensions. The result is a more flexible approach for imaging dynamic environments where conventional cameras can struggle.

42 ENGINEERING↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Experimental investigation of H-mode pedestal turbulence using a charge exchange imaging diagnostic system at DIII-D

Microtearing modes (MTMs) (ω ~ ω de k θ ρ s ~ 0.1, k r ρ s ~ 0.3 – 1.0) are predicted to cause substantial electron thermal transport in the H-mode pedestal, limiting fusion performance on high-power devices. Localized 2D measurements of low-to-intermediate wavenumber density fluctuations in the edge of DIII-D H-mode plasmas suggest the presence of temporally intermittent or ‘bursting’ MTMs during the inter-ELM cycle in the steep gradient region. These measurements are obtained using a new intermediate radial resolution multichannel Charge eXchange Imaging (CXI) diagnostic that analyzes the intensity of the CVI emission at 529 nm. The mode is peaked near ρ = 0.97 with a radial full-width half maximum of 1.5–2.0 cm and a normalized density fluctuation amplitude peak of $\frac{dn_C}{n_C}$ ~ 5%, peaking near 60 kHz in the lab frame. The mode additionally features a broad spectral width from 30 to 180 kHz and propagates in the electron diamagnetic direction in the plasma frame. CXI measurements taken during discharges with high density and current ramps provide evidence that MTMs become unstable at finite collisionality and remain at nearly the same location in ρ-space despite scanning of rational surface position. This indicates that the location of the peak in the electron diamagnetic frequency is a stronger driving force than individual rational surfaces.

DIII-D↗

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration and Concept of Operations for a Zero-Knowledge Protocol Passive Imaging Measurement for Arms Control

Here, we present an imaging system that employs zero-knowledge protocols to protect sensitive geometrical information, along with procedures to increase confidence in the result. The goal of this work is to enable the inclusion of warhead confirmation measurements in future arms control treaties. We present a demonstration of both true positive and true negative measurements that validate models and establish authenticating procedures toward meeting acceptance requirements for use in nuclear facilities. We use a two-dimensional time-encoded fast neutron imaging system with an anti-symmetric mask pattern; the fast neutron count values exceeding minimum or maximum thresholds indicate that two measured items are not identical. Laboratory measurements over twenty trials show that alarm rates for negative confirmation measurements are within uncertainties of model predictions. Positive confirmation measurements indicate that alarm rates are large enough to encourage treaty compliance.

Sweany, Melinda Dominique [Sandia National Laborat↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Resolution 3D Acoustic Borehole Integrity Monitoring (Research Performance Progress Report Q2 2021)

Real-time, in-situ, high spatial resolution (sub-cm) imaging of the near-borehole environment would revolutionize wellbore diagnostics and integrity assessment by direct observation of defects. It is becoming increasingly apparent, that better understanding of the near-wellbore environment is required to meet the safety and operational needs in challenging environments such as those present in subsurface energy extraction (geothermal) and storage (CO2 sequestration) applications. Therefore, it is important to have a more robust ability to image the near-borehole and reliably detect defects. It was proposed to further develop and improve our advanced 3D imaging system to evaluate casing defects (e.g. corrosion) and cement quality in either open- or cased-borehole with the ultimate goal to develop a commercially deployable technology. The system consists of a unique acoustic source (LANL) and advanced inversion techniques for image processing (LANL, ORNL). This system will provide comprehensive borehole integrity monitoring with improved resolution over existing techniques. As an application of this imaging system, we will characterize the effectiveness of next-generation wellbore completion technology (NETL, SNL), and will demonstrate that, unlike current technology, the proposed approach can successfully characterize foamed cements.

15 GEOTHERMAL ENERGY↗

Report Q3FY21 - High-Resolution 3D Acoustic Borehole Integrity Monitoring

Real-time, in-situ, high spatial resolution (sub-cm) imaging of the near-borehole environment would revolutionize wellbore diagnostics and integrity assessment by direct observation of defects. It is becoming increasingly apparent, that better understanding of the near-wellbore environment is required to meet the safety and operational needs in challenging environments such as those present in subsurface energy extraction (geothermal) and storage (CO 2 sequestration) applications. Therefore, it is important to have a more robust ability to image the near-borehole and reliably detect defects. It was proposed to further develop and improve our advanced 3D imaging system to evaluate casing defects (e.g. corrosion) and cement quality in either open- or cased-borehole with the ultimate goal to develop a commercially deployable technology. The system consists of a unique acoustic source (LANL) and advanced inversion techniques for image processing (LANL, ORNL). This system will provide comprehensive borehole integrity monitoring with improved resolution over existing techniques. As an application of this imaging system, we will characterize the effectiveness of next-generation wellbore completion technology (NETL, SNL), and will demonstrate that, unlike current technology, the proposed approach can successfully characterize foamed cements.

42 ENGINEERING↗

High-Resolution 3D Acoustic Borehole Integrity Monitoring (Final Report)

Real-time, in-situ, high spatial resolution (sub-cm) imaging of the near-borehole environment would revolutionize wellbore diagnostics and integrity assessment by direct observation of defects. It is becoming increasingly apparent, that better understanding of the near-wellbore environment is required to meet the safety and operational needs in challenging environments such as those present in subsurface energy extraction (geothermal) and storage (CO2 sequestration) applications. Therefore, it is important to have a more robust ability to image the near-borehole and reliably detect defects. It was proposed to further develop and improve our advanced 3D imaging system to evaluate casing defects (e.g. corrosion) and cement quality in either open- or cased-borehole with the ultimate goal to develop a commercially deployable technology. The system consists of a unique acoustic source (LANL) and advanced inversion techniques for image processing (LANL, ORNL). This system will provide comprehensive borehole integrity monitoring with improved resolution over existing techniques. As an application of this imaging system, we will characterize the effectiveness of next-generation wellbore completion technology (NETL, SNL), and will demonstrate that, unlike current technology, the proposed approach can successfully characterize foamed cements.

42 ENGINEERING↗

Quantum Super-resolution Bioimaging using Massively Entangled Multimode Squeezed Light

This report presents a new method for realizing a super-resolution quantum imaging using massively entangled multimode squeezed light (MEMSL). Each branch of the entangled multimode light interacts with the sample and bears the spatially varying optical phase delay. When imaging optics with finite pupil sizes are used, information is lost. Thanks to the analyticity in the Fourier plane, a noiseless measurement would recover the lost information and accomplish super resolution imaging beating the Rayleigh diffraction limit. I proved rigorously in a fully quantum formalism and presented that (1) such information recovery is possible and (2) the information recovery can be accomplished with much less resources when MEMSL is used than those needed in any non-entangled or non-squeezed classical imaging method. Furthermore, the action of the optical loss in the imaging system that degrades the imaging performance is also rigorously analyzed and presented. Several bioimaging applications that can benefit tremendously from the proposed quantum imaging scheme are also suggested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

Study of the electrothermal and MHD instabilities in exploding cylindrical foil liner

Abstract An experimental and numerical study of the plasma instabilities in an electrical exploding cylindrical Al liner is reported. The Al liner 3 mm in diameter and 10 μ m in thickness is exploded at the Qin-1 facility (450 ns, 400 kA). Various diagnostics, such as multi-frame laser shadowgraphy, an x-ray framing camera, and an x-ray backlighting system are developed. The different imaging systems are sensitive to plasma of different areal densities based on the comparison between the experiments and simulation, which reveal the dynamics of the exploding liner in more detail. The laser shadow images show the low-density plasma (∼1–2 × 10 −4 g cm −2 ) at the edge of the liner, and both the amplitude and wavelength of the plasma instabilities increase over time, which are considered to be magnetohydrodynamic (MHD) instabilities rather than electrothermal instabilities. During the ablation of the liner, quasi-periodic azimuthally correlated striations are directly observed in extreme ultraviolet (EUV) self-emission images. Meanwhile, the vertical filaments, which are electrothermal instabilities for plasma under the condition of ∂ η /∂ T < 0, are also observed in EUV self-emission images. The x-ray backlighting images of the exploding liner are obtained by placing an X -pinch load on the current-return path to serve as an x-ray point source (∼1 ns, ∼10 μ m). The x-ray backlighting results show the behavior of the high-density plasma (∼1.89 × 10 −3 g cm −2 ), which includes the transition from electrothermal to MHD instabilities. Finally, we realized a 2D MHD simulation of the exploding liner under experimental conditions, which shows good agreement with the results of the experimental perturbation.

Physics↗

Kraken Imager and Camera Systems

Presentation describes the Kraken imager and camera systems under development for use at the Nevada National Security Site for work conducted by the National Nuclear Security Administration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗