SEARCH · Search NASA
Results for “impact study”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Technology Solutions Case Study: Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate
Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.
Building America Case Study: Impact of Slab-Foundation Heat Transfer on Space-Conditioning Energy Use in Florida, Cocoa, Florida
Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new home floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.
Building America Case Study: Impact of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps, Cocoa, Florida
A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity system compared to the fixed-capacity system.
Building America Case Study: Impact of Slab-Foundation Heat Transfer on Space-Conditioning Energy Use in Florida, Cocoa, Florida
Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new home floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.
Building America Case Study: Impact of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps, Cocoa, Florida
A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity system compared to the fixed-capacity system.
High-Frequency Data for Distribution Grid PV Impact Studies: Importance and Availability.
Abstract not provided.
A Fast Quasi-Static Time Series (QSTS) Simulation Method for PV Impact Studies Using Voltage Sensitivities of Controllable Elements.
Abstract not provided.
A Fast Quasi-Static Time Series (QSTS) Simulation Method for PV Impact Studies Using Voltage Sensitivities of Controllable Elements.
Abstract not provided.
Hardware-in-the-Loop (HIL) Simulations for Smart Grid Impact Studies: Preprint
Hardware-in-the-loop (HIL) simulation is increasingly employed in power engineering as more inverter-based generation and smart appliances are connected to the electric grid. HIL techniques allow for co-simulation of analytical models with actual devices whose complex behavior is computationally inefficient or difficult to capture. It also allows for testing of the behavior of these devices under adverse conditions that only occur rarely in the field, but that are important to evaluate. An overview of how HIL simulation has been used to date is provided. This paper further proposes that HIL simulation should play an important role in evaluating new control strategies, especially at the distribution level, that are being proposed to allow for continued affordable and reliable operation of the electric grid with the introduction of these new technologies. It presents a new capability that was developed to enable evaluation of interactions between residential loads and the smart grid: smart home hardware-in-the-loop. The paper includes results from an HIL simulation that incorporates multiple technologies and controls.
Scalability of the Vector Quantization Approach for Fast QSTS Simulation for PV Impact Studies.
Abstract not provided.
Scalability of the Vector Quantization Approach for Fast QSTS Simulation for PV Impact Studies.
Abstract not provided.
Impact Study of Value-Added Functionality on Inverter Reliabiity in Energy Storage Systems.
Abstract not provided.