Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Anti-reflection coating with mullite and Duroid for large-diameter cryogenic sapphire and alumina optics

We developed a broadband two-layer anti-reflection (AR) coating for use on a sapphire half-wave plate (HWP) and an alumina infrared (IR) filter for the cosmic microwave background (CMB) polarimetry. Measuring the faint CMB B-mode signals requires maximizing the number of photons reaching the detectors and minimizing spurious polarization due to reflection with an off-axis incident angle. Sapphire and alumina have high refractive indices of 3.1 and are highly reflective without an AR coating. This paper presents the design, fabrication, quality control, and measured performance of an AR coating using thermally sprayed mullite and Duroid 5880LZ. This technology enables large optical elements with diameters of 600 mm. We also present a thermography-based nondestructive quality control technique, which is key to assuring good adhesion and preventing delamination when thermal cycling. We demonstrate the average reflectance of about 2.6% (0.9%) for two observing bands centered at 90/150 (220/280) GHz. At room temperature, the average transmittance of a 105 mm square test sample at 220/280 GHz is 83%, and it will increase to 90% at 100 K, attributed to reduced absorption losses. Therefore, our developed layering technique has proved effective for 220/280 GHz applications, particularly in addressing dielectric loss concerns. This AR coating technology has been deployed in the cryogenic HWP and IR filters of the Simons Array and the Simons observatory experiments and applies to future experiments such as CMB-S4.

Sakaguri, Kana (ORCID:0000000156678118)↗

Engineering of Lead Selenide Quantum Dot Based Devices and Core/Shell Heterostructures

Near infrared (NIR) emitting colloidal quantum dots (QDs) such as PbSe are interesting materials for implementation in various optoelectronic devices such as solar cells, photodetectors, and radiation detectors. Material properties like size tunable emission wavelengths, facile solution processability, the possibility of carrier multiplication and Auger assisted up-conversion, and high Z number provide PbSe QDs with unique advantages over many currently available commercial materials used in these devices. In this dissertation, after an introduction to QDs in general, we first focus on synthesis of PbSe-based heterostructured QDs for study via optical spectroscopy. PbSe/CdSe QDs synthesized via cation exchange reaction were used as seeds to study the proper conditions for further CdSe or CdS shell growth. Optical spectroscopy studies show that growth of thicker CdSe shells leads to tunable visible emission, while growth of thick CdS shells can greatly increase the photoluminescence quantum yield (PLQY) observed from the intermediate CdSe shell. NIR PL lifetimes can be greatly enhanced by the growth of CdS shells, due to strong delocalization of the hole wavefunction within the PbSe core, while the electron is delocalized throughout the QD including in the CdS shell, resulting in radiative lifetimes in the tens of microseconds. Two pulse delay measurements show that Auger assisted up conversion is also taking place in these engineered QD dot heterostructures. In the sections that follow, we look at QD devices, first with a focus on novel devices fabricated from PbSe QDs, using an amine synthesis method that allows for facile in-solution ligand exchange. QD film mobilities are measured for PbSe QDs capped with various short ionic ligands. Carrier densities in PbSe QD films are calculated from C-V measurements, showing for the first time that carrier densities can be modulated by simply changing the capping ligand. vii Radiation detectors utilizing PbSe QDs capped with KI and NH4I ligands show tangible response to incident alpha radiation. Current output response to alpha radiation is dependent on strength of radiation source and amount of bias voltage applied. In the final section a critical review of hybrid layered 2D-QD photodetectors is presented. In a typical example, PbSe and PbS QDs act as the absorbing layer in phototransistor devices which utilize layered 2D materials such as graphene and transition metal dichalcogenides as transport layers. Resulting devices display high gains and improved directivities compared to QD only and 2D only devices.

36 MATERIALS SCIENCE↗

Mid-infrared photodetection with 2D metal halide perovskites at ambient temperature

The detection of mid-infrared (MIR) light is technologically important for applications such as night vision, imaging, sensing, and thermal metrology. Traditional MIR photodetectors either require cryogenic cooling or have sophisticated device structures involving complex nanofabrication. Here, we conceive spectrally tunable MIR detection by using two-dimensional metal halide perovskites (2D-MHPs) as the critical building block. Leveraging the ultralow cross-plane thermal conductivity and strong temperature-dependent excitonic resonances of 2D-MHPs, we demonstrate ambient-temperature, all-optical detection of MIR light with sensitivity down to 1 nanowatt per square micrometer, using plastic substrates. Through the adoption of membrane-based structures and a photonic enhancement strategy unique to our all-optical detection modality, we further improved the sensitivity to sub–10 picowatt-per-square-micrometer levels. The detection covers the mid-wave infrared regime from 2 to 4.5 micrometers and extends to the long-wave infrared wavelength at 10.6 micrometers, with wavelength-independent sensitivity response. Our work opens a pathway to alternative types of solution-processable, long-wavelength thermal detectors for molecular sensing, environmental monitoring, and thermal imaging.

Li, Yanyan [Yale University, New Haven, CT (United↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two and three-dimensional near infrared subcutaneous structure imager using realtime nonlinear video processing

A method includes placing an imaging device in contact with a sample, irradiating the sample via an illuminator such that radiation scatters off of the structure, and providing the scattered radiation to a detector to generate a digital video signal. A processor then performs various operations including subtracting a sum of a black state value and a user-defined black level clamping value from the digital video signal to create subtracted image data, substituting negative values in the subtracted image data with a reference value to create modified image data, and amplifying the modified image data by a user-defined gain to create contrast enhanced image data.

Krasowski, Michael J.↗

Sensitive photodetection below silicon bandgap using quinoid-capped organic semiconductors

High-sensitivity organic photodetectors (OPDs) with strong near-infrared (NIR) photoresponse have attracted enormous attention due to potential applications in emerging technologies. However, few organic semiconductors have been reported with photoelectric response beyond ~1.1 μm, the detection limit of silicon detectors. Here, we extend the absorption of organic small-molecule semiconductors to below silicon bandgap, and even to 0.77 eV, through introducing the newly designed quinoid-terminals with high Mulliken-electronegativity (5.62 eV). The fabricated photodiode-type NIR OPDs exhibit detectivity (D*) over 10 12 Jones in 0.41 to 1.2 μm under zero bias with a maximum of 2.9 × 10 12 Jones at 1.02 μm, which is the highest D* for reported OPDs in photovoltaic-mode with response spectra beyond 1.1 μm. The high D* in 0.9 to 1.2 μm is comparable to those of commercial InGaAs photodetectors, despite the detection limit of our OPDs is shorter than InGaAs (~1.7 μm). A spectrometer prototype with a wide measurable region (0.4 to 1.25 μm) and NIR imaging under 1.2-μm illumination are demonstrated successfully in OPDs.

36 MATERIALS SCIENCE↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

Multimodal characterization of Te inclusions in Cd 1−x Zn x Te and Cd 1−x Zn x Te 1−y Se y for gamma and X-ray detectors

While CdZnTe (CZT) and CdZnTeSe (CZTS) semiconductors have emerged as compounds for room-temperature gamma and X-ray detection materials, they continue to be constrained by the formation of Te-inclusion defects generated during the growth and post-growth phases of the material, which adversely affect the detector performance. We demonstrate the utility of multimodal microscopic imaging and analysis for the characterization of the optical and electronic properties of Te inclusions in CZT and CZTS crystals at both micron and nanometer length scales. Having first identified regions with micron-scale Te inclusions using confocal Raman microscopy techniques, optically coupled infrared scattering near-field optical microscopic mapping was performed to map the distribution of these inclusions with nanometer spatial resolution and correlate the presence of Te inclusions in the matrix with other properties. Kelvin probe force microscopy was then utilized to characterize the variations of the work function associated with the presence of Te inclusions. Here, we observe an increase of ~ 240 mV in the work function associated with Te inclusions compared to the bulk CZT/CZTS crystals. Additionally, we observe that individual bulk grains in CZT can exhibit slight potential variations. Our findings develop a portrait of the charge trapping mechanisms in CZT and CZTS that act to degrade detector performance, while the demonstration of these combined microscopy techniques provides a new analytical tool that can be utilized for further optimization of the detector performance for these semiconducting compounds.

36 MATERIALS SCIENCE↗

Light-tight Skipper-CCDs for X-Ray Detection in Space

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising technology for space-based X-ray astronomy. In this scenario, optical and near-infrared photons may saturate the sensor, distorting the reconstructed signal. We present a light-tight shield for skipper-CCDs to suppress optical backgrounds while preserving X-ray detection efficiency. We deposited thin aluminum layers on the CCD surface using an e-beam evaporator and evaluated their blinding performance across wavelengths from 650 to 1000 nm using a monochromator, as well as the X-ray transmission using an 55 Fe source. We find that 50 and 100 nm layers provide >99.6% light suppression, with no efficiency loss for 5.9 and 6.4 keV X-rays. In addition, we used Geant4 simulations to extend these results to a broader energy range and quantify the efficiency loss for different aluminum thicknesses. Results show that thin aluminum coatings are an effective, low-cost solution for optical suppression in skipper-CCDs intended for X-ray detection and space instrumentation.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlated single- and few-electron backgrounds milliseconds after interactions in dual-phase liquid xenon time projection chambers

In this work, we characterize single- and few-electron backgrounds that are observed in dual-phase liquid xenon time projection chambers at timescales greatly exceeding a maximum drift time after an interaction. These instrumental backgrounds limit a detector's sensitivity to dark matter and cosmogenic neutrinos. Using the ~150g liquid xenon detector at Purdue University, we investigate how these backgrounds, produced after 122keV 57 Co Compton interactions, behave under different detector conditions. We find that the rates of single- and few-electron signals follow power-laws with time after the interaction. We observe linearly increasing rates with increased extraction field, and increased rates in the single-electron background with increased drift field. Normalizing the rates to the primary interaction's measured ionization signal, the rates increase linearly with the depth of the interaction. We test the hypothesis that infrared photons (1550nm) would stimulate and accelerate electron emission via photodetachment from impurities, but find that even 1 Watt of infrared light fails to reduce these backgrounds. We thus provide a characterization that can inform background models for low-energy rare event searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications

High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.

36 MATERIALS SCIENCE↗

Superconducting qubits for particle detection and fundamental tests of quantum mechanics

Many fundamental questions at the interface of quantum mechanics, gravity, and measurement remain relatively unexplored in the laboratory. These include whether spatial superpositions experience gravitational redshift, how the quantum Zeno effect propagates through entangled systems, and whether quantum information is globally conserved or fundamentally lost during measurement-induced wavefunction collapse. In this colloquium, I will discuss how superconducting qubits—developed primarily for quantum computing—can be repurposed as ultra sensitive detectors to probe these questions and to search for low-energy particle interactions. I will describe my work at Fermilab on stabilizing these devices to the level required for next-generation qubit-based sensors. This includes mitigating decoherence from infrared radiation and cosmic rays, using machine-learning techniques to accelerate superconducting qubit design, and leveraging the quantum Zeno effect to improve coherence times and suppress qubit frequency fluctuations. Together, these advances point toward a new class of quantum sensors capable of testing fundamental physics.

Seidel, Olivia [Fermilab]↗

Shooter Alarm System Final Report FY23

Lawrence Livermore National Laboratory (LLNL) is developing a multiphysics sensor package for automatic live arms fire detection for use in schools, houses of worship, hospi tals, etc. The goal is to have a package the size of a common smoke or CO2 detector with a price point of $50 or less which may be deployed throughout the aforementioned facilities. The commercial device will detect live gun fire with low probability of false alarm and auto matically alert first responders. A prototype board with four accelerometers, two infrared (IR) and two microphones has been developed and deployed at two experiments at LLNL’s Small Firearms Training Facility (SFTF). The device successfully and consistently measured signals on the accelerometer and acoustic channels. IR responses were measured depending upon the environment and sound source.

42 ENGINEERING↗

Damage-free Analysis of Biological Materials by Vibrational Spectroscopy in the EM

In summary, vibrational spectroscopy in the electron microscope promises to probe biological materials in a way that is similar to infrared spectroscopy, at a spatial resolution of about 30-50 nm, while circumventing radiation damage. Herein we are now focused on developing this technique fully, using a side-entry cryotransfer holder in a Nion HERMES electron microscope equipped with a fast and efficient EELS direct detector [10], and capable of 5 meV (and better) energy resolution. The results of these investigations will be reported at the meeting.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of scattering ratio profiles retrieved from ALADIN/Aeolus and CALIOP/CALIPSO observations and preliminary estimates of cloud fraction profiles

The space-borne active sounders have been contributing invaluable vertically resolved information of atmospheric optical properties since the launch of Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) in 2006. To build long-term records from space-borne lidars useful for climate studies, one has to understand the differences between successive space lidars operating at different wavelengths, flying on different orbits, and using different viewing geometries, receiving paths, and detectors. In this article, we compare the results of Atmospheric Laser Doppler INstrument (ALADIN) and Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) lidars for the period from 28 June to 31 December 2019. First, we build a dataset of ALADIN–CALIOP collocated profiles (Δdist<1°; Δtime<6 h). Then we convert ALADIN's 355 nm particulate backscatter and extinction profiles into the scattering ratio vertical profiles SR(z) at 532 nm using molecular density profiles from Goddard Earth Observing System Data Assimilation System, version 5 (GEOS-5 DAS). And finally, we build the CALIOP and ALADIN globally gridded cloud fraction profiles CF(z) by applying the same cloud detection threshold to the SR(z) profiles of both lidars at the same spatial resolution. Before comparing the SR(z) and CF(z) profiles retrieved from the two analyzed lidar missions, we performed a numerical experiment to estimate the best achievable cloud detection agreement CDA norm (z) considering the differences between the instruments. We define CDA norm (z) in each latitude–altitude bin as the occurrence frequency of cloud layers detected by both lidars, divided by a cloud fraction value for the same latitude–altitude bin. We simulated the SR(z) and CF(z) profiles that would be observed by these two lidars if they were flying over the same atmosphere predicted by a global model. By analyzing these simulations, we show that the theoretical limit for CDA$_{norm}^{theor}$(z) for a combination of ALADIN and CALIOP instruments is equal to 0.81±0.07 at all altitudes. In other words, 19 % of the clouds cannot be detected simultaneously by two instruments due to said differences. The analyses of the actual observed CALIOP–ALADIN collocated dataset containing ~78 000 pairs of nighttime SR(z) profiles revealed the following points: (a) the values of SR(z) agree well up to ~3 km height. (b) The CF(z) profiles show agreement below ~3 km, where ~80 % of the clouds detected by CALIOP are detected by ALADIN as expected from the numerical experiment. (c) Above this height, the CDA$_{norm}^{obs}$(z) reduces to ~50 %. (d) On average, better sensitivity to lower clouds skews ALADIN's cloud peak height in pairs of ALADIN–CALIOP profiles by ~0.5±0.6 km downwards, but this effect does not alter the heights of polar stratospheric clouds and high tropical clouds thanks to their strong backscatter signals. (e) The temporal evolution of the observed CDA$_{norm}^{obs}$(z) does not reveal any statistically significant change during the considered period. This indicates that the instrument-related issues in ALADIN L0/L1 have been mitigated, at least down to the uncertainties of the following CDA$_{norm}^{obs}$(z) values: 68±12 %, 55±14 %, 34±14 %, 39±13 %, and 42±14 % estimated at 0.75, 2.25, 6.75, 8.75, and 10.25 km, respectively.

54 ENVIRONMENTAL SCIENCES↗

Enantioselective Se lattices for stable chiroptoelectronic processing media

Chiroptoelectronic devices are crucial for applications in quantum computing, spin optical communications, and magnetic recording. However, the limited efficiency and low stability of conventional circularly polarized light (CPL)-sensing materials have restricted their broader use. Here, we introduce atomic chiral Se nanorod (NRs) films as broadband CPL detectors, leveraging the intrinsic chirality and stability of Se nanocrystals. We also perform incident circular polarization (ICP)-Raman optical activity (ROA) to explore the chiroptical activity of the large-area films. The Se NRs thin films detected CPL across a broad range from ultraviolet (UV) to short-wavelength infrared (SWIR), with a responsivity dissymmetry factor of up to 0.4, maintaining high stability under ambient conditions for longer than 13 months. CPL-sensitive Se NRs with intrinsic chirality have potential applications in chiral photonic synapses, chiral spin devices, and CPL-sensitive photocatalysts. ICP-ROA mapping also advances the analysis of 2D chiral materials.

Nanophotonics and plasmonics↗

Short-Wave Infrared Upconverting Nanoparticles

Optical technologies enable real-time, noninvasive analysis of complex systems but are limited to discrete regions of the optical spectrum. While wavelengths in the short-wave infrared (SWIR) window (typically, 1700-3000 nm) should enable deep subsurface penetration and reduced photodamage, there are few luminescent probes that can be excited in this region. Here, we report the discovery of lanthanide-based upconverting nanoparticles (UCNPs) that efficiently convert 1740 or 1950 nm excitation to wavelengths compatible with conventional silicon detectors. Screening of Ln3+ ion combinations by differential rate equation modeling identifies Ho3+/Tm3+ or Tm3+ dopants with strong visible or NIR-I emission following SWIR excitation. Experimental upconverted photoluminescence excitation (U-PLE) spectra find that 10% Tm3+-doped NaYF4 core/shell UCNPs have the strongest 800 nm emission from SWIR wavelengths, while UCNPs with an added 2% or 10% Ho3+ show the strongest red emission when excited at 1740 or 1950 nm. Mechanistic modeling shows that addition of a low percentage of Ho3+ to Tm3+-doped UCNPs shifts their emission from 800 to 652 nm by acting as a hub of efficient SWIR energy acceptance and redistribution up to visible emission manifolds. Parallel experimental and computational analysis shows rate equation models are able to predict compositions for specific wavelengths of both excitation and emission. These SWIR-responsive probes open a new IR bioimaging window, and are responsive at wavelengths important for vision technologies.

Qi, Xiao↗