Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrumental resolution function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Summer Aerosol and Trace Gas Observations in Houston, Texas Using an Adaptable Mobile Facility

An aerosol container featuring a shared inlet system was deployed to Houston, Texas in July 2022, enabling direct, high-time-resolution in situ measurements of aerosols and trace gases. The internal rack system and floorplan was designed for adaptable modularity to elucidate aerosol physicochemical processes at fine scales. The design allowed for the deployment of a core instrument suite and additional customized research grade instruments. A heterogeneous mixture of aerosols was observed during three regimes: (1) intermittent black carbon (BC) and diurnal variations in aerosol chemical composition, (2) observed particle growth associated with SO 2 , (3) transported supermicron dust. The high variability of observed particles and gases in high time resolution indicated a complex urban area with multiple local and regional sources and processes. Particle growth rates of 7–16 nm/hr were observed for submicron particles during periods when SO 2 was >0.5 ppbv. Two periods of multi-day long-range transport events of dust from the African Sahara were observed in the supermicron and submicron particle modes with total mass concentrations up to 30 μg m −3 . Aerosol scattering angstrom exponents and extinction coefficients (B ext ) increased with humidity as a function of particle composition. The measurements demonstrate collaborative capabilities that can be used to increase observations of aerosol processing, microphysical and optical properties, internal mixing state, and supermicron aerosol that are not parameterized or missing in global Earth energy system models.

54 ENVIRONMENTAL SCIENCES↗

Deep-Learning Electron Diffractive Imaging

Here, we report the development of deep-learning coherent electron diffractive imaging at subangstrom resolution using convolutional neural networks (CNNs) trained with only simulated data. We experimentally demonstrate this method by applying the trained CNNs to recover the phase images from electron diffraction patterns of twisted hexagonal boron nitride, monolayer graphene, and a gold nanoparticle with comparable quality to those reconstructed by a conventional ptychographic algorithm. Fourier ring correlation between the CNN and ptychographic images indicates the achievement of a resolution in the range of 0.70 and 0.55 Å. We further develop CNNs to recover the probe function from the experimental data. The ability to replace iterative algorithms with CNNs and perform real-time atomic imaging from coherent diffraction patterns is expected to find applications in the physical and biological sciences.

47 OTHER INSTRUMENTATION↗

PET Imaging of Leg Arteries for Determining the Input Function in PET/MRI Brain Studies Using a Compact, MRI-Compatible PET System

In this work, we used a compact, high-resolution, and magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) camera (VersaPET) to assess the feasibility of measuring the image-derived input function (IDIF) from arteries in the leg with the ultimate goal of enabling fully quantitative PET brain imaging without blood sampling. We used this approach in five 18 F-FDG PET/MRI brain studies in which the input function was also acquired using the gold standard of serial arterial blood sampling. After accounting for partial volume, dispersion, and calibration effects, we compared the metabolic rates of glucose (MRglu) quantified from VersaPET IDIFs in 80 brain regions to those using the gold standard and achieved a bias and variability of <5% which is within the range of reported test-retest values for this type of study. We also achieved a strong linear relationship (R 2 >0.97) against the gold standard across regions. The results of this preliminary study are promising and support further studies to optimize methods, validate in a larger cohort, and extend to the modeling of other radiotracers.

47 OTHER INSTRUMENTATION↗

Billion-pixel x-ray camera (BiPC-X)

The continuing improvement in quantum efficiency (above 90% for single visible photons), reduction in noise (below 1 electron per pixel), and shrink in pixel pitch (less than 1 μm) enable billion-pixel x-ray cameras (BiPC-X) based on commercial complementary metal–oxide–semiconductor (CMOS) imaging sensors. We describe BiPC-X designs and prototype construction based on flexible tiling of commercial CMOS imaging sensors with millions of pixels. Device models are given for direct detection of low energy x rays (<10 keV) and indirect detection of higher energies using scintillators. Modified Birks’s law is proposed for light yield non-proportionality in scintillators as a function of x-ray energy. Single x-ray sensitivity and spatial resolution have been validated experimentally using a laboratory x-ray source and the Argonne Advanced Photon Source. Possible applications include wide field-of-view or large x-ray aperture measurements in high-temperature plasmas, the state-of-the-art synchrotron, x-ray free electron laser, and pulsed power facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A transmission hologram for slitless spectrophotometry on a convergent telescope beam. 1. Focus and resolution

We report in this paper the test of a plane holographic optical element to be used as an aberration-corrected grating for a slitless spectrograph, inserted in a convergent telescope beam. Our long-term objective is the optimization of a specific hologram to switch the auxiliary telescope imager of the Vera Rubin Observatory into an accurate slitless spectrograph, dedicated to the atmospheric transmission measurement. We present and discuss here the promising results of tests performed with prototype holograms at the CTIO $0.9\,$m telescope during a run of 17 nights in 2017 May–June. After their on-sky geometrical characterization, the performances of the holograms as aberration-balanced dispersive optical elements have been established by analysing spectra obtained from spectrophotometric standard stars and narrow-band emitter planetary nebulae. Thanks to their additional optical function, our holographic disperser prototypes allow us to produce significantly better focused spectra within the full visible wavelength domain $[370,1050]\,$nm than a regular grating, which suffers from strong defocusing and aberrations when used in similar conditions. We show that the resolution of our slitless on-axis spectrograph equipped with the hologram approaches its theoretical performance. While estimating the benefits of a hologram for the spectrum resolution, the roadmap to produce a competitive holographic element for the Vera Rubin Observatory auxiliary telescope has been established.

79 ASTRONOMY AND ASTROPHYSICS↗

Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source

The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.

36 MATERIALS SCIENCE↗

Cinematic reflectometry using QIKR, the quite intense kinetics reflectometer

The Quite Intense Kinetics Reflectometer (QIKR) will be a general-purpose, horizontal-sample-surface neutron reflectometer. Reflectometers measure the proportion of an incident probe beam reflected from a surface as a function of wavevector (momentum) transfer to infer the distribution and composition of matter near an interface. The unique scattering properties of neutrons make this technique especially useful in the study of soft matter, biomaterials, and materials used in energy storage. Exploiting the increased brilliance of the Spallation Neutron Source Second Target Station, QIKR will collect specular and off-specular reflectivity data faster than the best existing such machines. It will often be possible to collect complete specular reflectivity curves using a single instrument setting, enabling “cinematic” operation, wherein the user turns on the instrument and “films” the sample. Samples in time-dependent environments (e.g., temperature, electrochemical, or undergoing chemical alteration) will be observed in real time, in favorable cases with frame rates as fast as 1 Hz. Cinematic data acquisition promises to make time-dependent measurements routine, with time resolution specified during post-experiment data analysis. This capability will be deployed to observe such processes as in situ polymer diffusion, battery electrode charge–discharge cycles, hysteresis loops, and membrane protein insertion into lipid layers.

47 OTHER INSTRUMENTATION↗

Recommendations for Minimum Required Error Codes for Electric Vehicle Charging Infrastructure

OCPP protocol manages the interaction between the EVSE and its respective back-end communication network. It plays a pivotal role in both error reporting and troubleshooting, carried out primarily through the CSMS. OCPP defines both standard error codes and a flexible framework for creating and communicating custom error codes. The OCPI protocol orchestrates the communication between different backhaul communication networks, incorporating the exchange of error codes. These error codes are instrumental in pinpointing and rectifying issues that can surface prior to, during, or after charging operations, fortifying the reliability and resilience of the EV charging infrastructure. The flexibility offered by the OCPP and OCPI frameworks through the introduction of custom error codes also creates its own set of challenges. While the integration of custom error codes allows for enhanced granularity, it also introduces inconsistencies and fragmentation within the overarching diagnostic reporting system. To address the challenges with custom error codes this report proposes a set of Minimum Required Error Codes (MRECs) for streamlined error reporting, interpretability, and diagnostics. Recommendations in this report are based on independent analysis of custom error codes from multiple stakeholders within the EV charging ecosystem. For better error resolution, this report also assigns one or more entities responsible for the resolution of every mentioned error code. Finally, a functional classification for each mentioned error code is also identified to describe the nature of the error. In summary, the purpose of this document is to simplify the troubleshooting process and increase charging reliability for all EV users. This report serves as a recommendation for industry stakeholders, encouraging a unified methodology to define, transmit, and interpret common error codes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Emerging Electrochemical Techniques for Probing Site Behavior in Single-Atom Electrocatalysts

Single-atom catalysts (SACs) have aroused tremendous interest over the past decade, particularly in the community of energy and environment-related electrocatalysis. A rapidly growing number of recent publications have recognized it as a promising candidate with maximum atomic utilization, distinct activity, and selectivity in comparison to bulk catalysts and nanocatalysts. However, the complexity of localized coordination environments and the dispersion of isolated sites lead to significant difficulties when it comes to gaining insight into the intrinsic behavior of electrocatalytic reactions. Furthermore, the low metal loadings of most SACs make conventional ensemble measurements less likely to be accurate on the subnanoscale. Thus, it remains challenging to probe the activity and properties of individual atomic sites by available commercial instruments and analytical methods. In spite of this, continuing efforts have lately focused on the development of advanced measurement methodologies, which are very useful to the fundamental understanding of SACs. There have recently been a number of in situ/operando techniques applied to SACs, such as electron microscopy, spectroscopy, and other analysis methods, which support relevant functions to identify the active sites and reaction intermediates and to investigate the dynamic behavior of localized structures of the catalytic sites. This Account aims to present recent electrochemical probing techniques which can be used to identify single-atomic catalytic sites within solid supports. First, we describe the basic principles of molecular probe methods for the study and analysis of electrocatalytic site behavior. In particular, the in situ probing technique enabled by surface interrogation scanning electrochemical microscopy (SISECM) can measure the active site density and kinetic rate with high resolution. An alternative electrochemical probing technique is further demonstrated on the basis of single-entity electrochemistry, which allows the unique electrochemical imaging of the size and catalytic rate of single atoms, molecules, and clusters. Next, the merits and limitations of different electrochemical techniques are then discussed, along with perspectives for future prospects. Apart from this, we further showcase the powerful capability of emerging electrochemical probing techniques for determining significant effects and properties of SACs for various electrocatalytic reactions, including oxygen reduction and evolution, hydrogen evolution, and nitrate reduction. Overall, electrochemical techniques with atomic resolution have greatly increased opportunities for observing, measuring, and understanding the surface and interface chemistry during energy conversion. In the future, it is anticipated that the development of electrochemical probing techniques will be advanced with innovative perspectives on the behavior and features of SACs. We hope that this Account can contribute in several ways to promoting the fundamental knowledge and technical progress of emerging electrochemical measurements for studying SACs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of ${\sim }10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7–10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5–7.0 keV), we resolved the inner-shell lines of Fe XIX-XXVI as well as the outer-shell lines of Fe XXV-XXVI . These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1–10 keV (roughly 10–100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

Astronomy and AstroPhysics↗

Commissioning a time-gated camera for fast neutron beamline spatial-energy characterization at LANSCE-WNR spallation source

An energy-resolved fast neutron beam imaging diagnostic has been successfully commissioned at the Weapons Neutron Research (WNR) spallation source within the Los Alamos Neutron Science Center (LANSCE) facility. This diagnostic replaces the existing analog phosphor image plates, which integrate across all neutron energies, as well as other particles, with a near-real-time energy-sensitive imaging capability. The system uses a fast plastic scintillator coupled with an intensified CCD camera. Specifically, the Teledyne Pi-MAX4 camera is coupled with either a 4 mm thick Eljen (EJ) 204 or 228 plastic scintillator. These scintillators are most sensitive to the fast neutrons (0.8-800 MeV) directly from the spallation source rather than low energy background radiation. Experimentally, these plastic scintillators were shown to have sufficiently fast decay to differentiate the bright gamma flash from the spallation neutrons. The spatial resolution is dominated by neutron beam divergence, with minimal additional contributions from scatter and light divergence. The system successfully resolved changes in neutron beam characteristics caused by intentional proton steering variations. Additionally, simulations of scintillator light yield as a function of thickness conducted using PHITS (with Scinful-QMD package) found that increasing scintillator thickness from 4 mm to 6 or 8 mm could potentially increase brightness ~ 3x. This may be explored if there is a need to reduce image acquisition time from several minutes to under one minute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging Nanoscale Energy Transport and Conversion with Ultrafast Electron Microscopy (Final Technical Report)

Light-matter interactions are ubiquitous in nature and reside at the heart of innumerable technologies. The cascade of processes that occur when a material absorbs a photon of light are exceedingly complex and are interwoven in both space and time, rendering precise determination of the atomic-scale and ultrafast mechanisms immensely challenging. The advent of methods for generating short pulses of light several decades ago led to major advances in understanding the initial moments of light absorption and the resultant effects, though directly interrogating the response of the atoms within the material continued to prove challenging. More recently, methods for generating ultrashort pulses of X-rays and fast electrons have opened the way to probing photoinduced structural dynamics of a wide range of matter in multiple phases. An especially promising laboratory-scale method is ultrafast electron microscopy (UEM), wherein the modalities of conventional transmission electron microscopes (imaging, diffraction, spectroscopy) are extended into the femtosecond temporal regime. Here, the ultrafast imaging and diffraction modalities of UEM were used to study the transient structural aspects of photoexcitation of semiconducting materials (e.g., spatially-resolved electron-phonon coupling, excitation and emission of acoustic phonons, and discrete nanoscale scattering processes). The project had three main objectives: (1) determination of the excitation mechanisms of dense, hypersonic charge-carrier waves and the spatially mediated means by which they couple to the lattice via coherent phonon emission, especially with UEM imaging, wherein effects of nanoscale structural and morphological features on the coupling and relaxation dynamics are expected to dictate nucleation sites and preferred wave vectors, (2) elucidation of photoinduced acoustic-phonon seeding, emergence, propagation, and decay over nanoscale crystal regions and especially with respect to local strain fields and atomic-scale disruptions in lattice order, and (3) interwoven with the first two were efforts aimed at realizing combined angstrom-femtosecond spatiotemporal imaging with UEM. The outcomes and impacts of this project were the generation of new knowledge with respect to fundamental light-matter interactions and, especially, the spatially-mediated excitation and evolution of the structural response of materials following coherent photoexcitation. Importantly, the spatial and temporal resolutions of the UEM imaging modalities used are well-suited for such studies and enable spatially-resolved mechanisms to be determined as a function of atomic order, structural features, and morphology. In addition, ultrafast crystallographic measurements were used to correlate real- and reciprocal-space dynamics in order to determine atomic-scale preferential wave vectors and ultrafast scattering mechanisms, especially as dictated by specimen boundary conditions. The obtained results, as detailed in peer-reviewed publications and presentations, illustrate the importance of ultrafast, angstrom-scale real-space imaging for developing a comprehensive understanding of energy transport and conversion in materials.

47 OTHER INSTRUMENTATION↗

Stellar populations with MEGARA: The inner regions of NGC 7025

This paper aims to determine the capabilities of the MEGARA spectrograph at the Gran Telescopio Canarias (GTC), which is an optical integral-field unit, for studying stellar populations. We also aim to exploit its combination of high spectral (R ~ 6000, 12 000 and 20 000) and spatial (0.62") resolution within its 12".5 × 11"​​.3 field of view. We do this by analysing the commissioning data of the nearby S0a galaxy NGC 7025. We establish a systematic method through which we can determine the properties of the stellar populations in the observations made with MEGARA, more specifically, within the MEGADES legacy project. For this paper in particular, we determine the properties of the stellar populations of NGC 7025. We used MEGARA observations of galaxy NGC 7025 that were taken during the commissioning phase of the instrument. We applied different approaches to estimate the properties of the stellar populations with the highest possible certainty. In addition to the specific study of NGC 7025 and in the context of the MEGADES survey, we have carried out a number of tests to determine the expected errors (including potential biases) in these star formation history (SFH) derivations as a function of these parameters, namely spectral setup, signal-to-noise ratio, σ, and the SFH itself. All the studies we conduct (both full spectral fitting and absorption line indices) of the stellar populations of NGC 7025 indicate that the stars that form its bulge have supersolar metallicity and considerably old ages (~10 Gyr) in general. Using three different combinations of MEGARA spectral setups, we determined that the bulge of NGC 7025 has smild negative mass-weighted age gradient. For the more detailed SFH, our results indicate that in addition to a rather constant star formation at early epochs, a peak in the formation history of the stars in the bulge is also found 3.5–4.5 Gyr ago. This partly explains the mass-weighted age gradients we measured. The scenario presented in NGC 7025 is that of an isolated galaxy under secular evolution that about 3.5–4.5 Gyr ago likely experienced a minor merger (mass ratio 1/10) that induced an increase in star formation and also perturbed the morphology of its outer disc. In addition to these specific results for NGC 7025, we report different lessons learned for the ongoing exploitation of the MEGADES survey with the GTC, such as the need to obtain combined observations in the LR-B + LR-V setups and a signal-to-noise ratio of at least 20 per Å.

79 ASTRONOMY AND ASTROPHYSICS↗

Resistive AC-Coupled Silicon Detectors: principles of operation and first results from a combined analysis of beam test and laser data

This paper presents the principles of operation of Resistive AC-Coupled Silicon Detectors (RSDs) and measurements of the temporal and spatial resolutions using a combined analysis of laser and beam test data. RSDs are a new type of n-in-p silicon sensor based on the Low-Gain Avalanche Diode (LGAD) technology, where the n+ implant has been designed to be resistive, and the read-out is obtained via AC-coupling. The truly innovative feature of RSD is that the signal generated by an impinging particle is shared isotropically among multiple read-out pads without the need for floating electrodes or an external magnetic field. Careful tuning of the coupling oxide thickness and the n+ doping profile is at the basis of the successful functioning of this device. Several RSD matrices with different pad width-pitch geometries have been extensively tested with a laser setup in the Laboratory for Innovative Silicon Sensors in Torino, while a smaller set of devices have been tested at the Fermilab Test Beam Facility with a 120 GeV/c proton beam. The measured spatial resolution ranges between 2.5μm for 70–100 pad-pitch geometry and 17μm with 200–500 matrices, a factor of 10 better than what is achievable in binary read-out (bin size/12). Beam test data show a temporal resolution of ~40ps for 200 μm pitch devices, in line with the best performances of LGAD sensors at the same gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution of Virtual Depth Sectioning from Four-Dimensional Scanning Transmission Electron Microscopy

Abstract One approach to three-dimensional structure determination using the wealth of scattering data in four-dimensional (4D) scanning transmission electron microscopy (STEM) is the parallax method proposed by Ophus et al. (2019. Advanced phase reconstruction methods enabled by 4D scanning transmission electron microscopy, Microsc Microanal25, 10–11), which determines the scattering matrix and uses it to synthesize a virtual depth-sectioning reconstruction of the sample structure. Drawing on an equivalence with a hypothetical confocal imaging mode, we derive contrast transfer and point spread functions for this parallax method applied to weakly scattering objects, showing them identical to earlier depth-sectioning STEM modes when only bright field signal is used, but that improved depth resolution is possible if dark field signal can be used. Through a simulation-based study of doped Si, we show that this depth resolution is preserved for thicker samples, explore the impact of shot noise on the parallax reconstructions, discuss challenges to making use of dark field signal, and identify cases where the interpretation of the parallax reconstruction breaks down.

3D imaging↗