Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrumentation: interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

135 records · Page 8

Astrometry in two-photon interferometry using an Earth rotation fringe scan

Optical interferometers may not require a phase-stable optical link between the stations if instead sources of quantum-mechanically entangled pairs could be provided to them, enabling long baselines. We developed a new variation of this idea, proposing that photons from two different astronomical sources could be interfered at two decoupled stations. Interference products can then be calculated in post-processing or requiring only a slow, classical connection between stations. In this work, we investigated practical feasibility of this approach. We developed a Bayesian analysis method for the earth rotation fringe scanning technique and showed that in the limit of high signal-to-noise ratio it reproduced the results from a simple Fisher matrix analysis. Here we identify candidate stair pairs in the northern hemisphere, where this technique could be applied. With two telescopes with an effective collecting area of ~ 2 m 2 , we could detect fringing and measure the astrometric separation of the sources at ~100 μas precision in a few hours of observations, in agreement with previous estimates.

47 OTHER INSTRUMENTATION↗

Time-lens photon Doppler velocimetry (TL-PDV)

Here, we describe a time lens (TL) to expand the dynamic range of photon Doppler velocimetry (PDV) systems. The principle and preliminary design of a TL-PDV system are explained and shown to be feasible through simulations. In a PDV system, an interferometer is used for measuring frequency shifts due to the Doppler effect from the target motion. However, the sampling rate of the electronics could limit the velocity range of a PDV system. A four-wave-mixing (FWM) TL applies a quadratic temporal phase to an optical signal within a nonlinear FWM medium (such as an integrated photonic waveguide or a highly nonlinear optical fiber). By spectrally isolating the mixing product, termed the idler, and with appropriate lengths of dispersion prior to and after this FWM TL, a temporally magnified version of the input signal is generated. Therefore, the frequency shifts of PDV can be “slowed down” with the magnification factor M of the TL. M = 1 corresponds to a regular PDV system without a TL. M = 10 has been shown to be feasible for a TL-PDV system. The use of this effect for PDV can expand the velocity measurement range and allow for the use of lower bandwidth electronics. TL-PDV will open up new avenues for various dynamic material experiments.

47 OTHER INSTRUMENTATION↗

Upgraded fiber-optic sensor system for dynamic strain measurement in Spallation Neutron Source

We describe an upgraded fiber-optic sensor system and its performance in measuring the dynamic strains in a mercury target of the Spallation Neutron Source (SNS). Strains result from dynamic pressure waves in the stainless-steel mercury target induced by short (~700 ns), intense (up to 23.3 kJ), high-energy (~1 GeV) proton pulses. In the upgraded sensor system, the output of each sensor head is interrogated with a compact, all-fiber based Faraday Michelson interferometer, which generates interference signals with a steady phase shift. Strain waveforms are recovered from the phase-shifted interference signals using a high-speed digital signal processing procedure developed in our previous work. We demonstrate successful measurements of dynamic strain pulses, e.g., 400με over 190μs , on a recently installed SNS target using the upgraded sensor system. The measured strain waveforms are analyzed for more than 20 sensor locations and/or orientations, and provide information regarding the temporal structure of strain profiles and dependence of the strain magnitude on the proton powers of 200 – 1400 kW. The new interrogator also measures the radiation-induced-attenuation (RIA) in the optical fiber, enabling experimental investigations of RIA profiles induced by a 700-ns radiation pulse. The radiation effects on the strain measurement performance are discussed over a radiation dose range of up to 4×10 8 Gy and an RIA compensation method is proposed. The measurements allow insight into the response of this unique piece of equipment and can be used for validation of simulations.

47 OTHER INSTRUMENTATION↗

Photon Doppler Velocimetry to Spatially Resolve Plasma Density in a Power Flow Gap

The understanding of power flow plasmas is important as we look towards next generation pulsed power (NGPP) as current losses could prohibit the goals of that facility. Therefore, it is important to have accurate diagnostics of the plasma parameters on the current machines, which can be used to help inform and improve simulations. Having these plasma parameters will help validate models and simulations to provide confidence when they are expanded to conditions relevant to NGPP. One important plasma parameter that can be measured is the electron density, which can be measured by photonic Doppler velocimetry (PDV). A PDV system has several key advantages over other interferometers by measuring relatively low densities (> 1 × 10 15 cm -2 ) with both spatial and temporal resolution. Experiments were performed on the Mykonos pulsed power machine, which is a 1 MA sub scale machine in which recent platforms have been developed to explore current densities relevant to the inner magnetically insulated transmission line (MITL) on the Z machine. Experiments were performed on two different platforms, the thin foil platform and the Mykonos parallel plate platform (MP3). In addition, a combination of both single-point and multi-point measurements were used. The single-point measurements proved to be very promising, providing a clear increase in density at about 70 ns into the current rise on thin foil experiments up to about 5 × 10 17 cm -3 before the probe stopped providing signal. While we did also see returns from multi-point measurements on both platforms, the signals were not as easy to interpret due to strong background effects. However, they do show initial promise for this diagnostic to measure density at several points across a 1 mm gap. These measurements provide insights in how to improve the diagnostic so that it can provide useful information on power flow relevant experiments.

47 OTHER INSTRUMENTATION↗

Demonstration of tokamak vertical stability control based on non-inductive Faraday-effect polarimetry measurements

Long-pulse or steady-state fusion reactors are envisioned to control vertical stability based on non-inductive measurements, i.e. that do not rely on temporal change of magnetic field. For the first time, vertical stability control using non-inductive Faraday-effect polarimetry measurements has been demonstrated. The Radial Interferometer-Polarimeter system on DIII-D is capable of microsecond resolution and was used to absolutely determine the vertical position of the plasma magnetic axis Z 0 . A vertical stability controller was developed to robustly stabilize diverted plasmas using Faraday-based measurements. The system was able to stabilize against vertical displacement events with growth rates up to 350 s -1 in elongated and elliptical plasma shapes, and instabilities with even higher growth rates are likely to be controllable with further improvements to controller tuning. Tests show that the Faraday-based controller remains effective and is capable of recovering from loss of control even when the plasma vertical position is far from the region where the linear model used to calculate Z 0 is most valid. Faraday control has also been activated during plasma ramp-up, demonstrating the robustness of the technique to larger systematic diagnostic uncertainty at low electron density.

Faraday-effect polarimetry↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Terrestrial Very-Long-Baseline Atom Interferometry: Workshop Summary

This document presents a summary of the 2023 Terrestrial Very-Long-Baseline Atom Interferometry Workshop hosted by CERN. The workshop brought together experts from around the world to discuss the exciting developments in large-scale atom interferometer (AI) prototypes and their potential for detecting ultralight dark matter and gravitational waves. The primary objective of the workshop was to lay the groundwork for an international TVLBAI proto-collaboration. This collaboration aims to unite researchers from different institutions to strategize and secure funding for terrestrial large-scale AI projects. The ultimate goal is to create a roadmap detailing the design and technology choices for one or more km-scale detectors, which will be operational in the mid-2030s. The key sections of this report present the physics case and technical challenges, together with a comprehensive overview of the discussions at the workshop together with the main conclusions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold atoms in space: community workshop summary and proposed road-map

We summarise the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with the European Space Agency (ESA) and national space and research funding agencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Terrestrial Very-Long-Baseline Atom Interferometry: summary of the second workshop

This summary of the second Terrestrial Very-Long-Baseline Atom Interferometry (TVLBAI) Workshop provides a comprehensive overview of our meeting held in London in April 2024 (Second Terrestrial Very-Long-Baseline Atom Interferometry Workshop, Imperial College, April 2024), building on the initial discussions during the inaugural workshop held at CERN in March 2023 (First Terrestrial Very-Long-Baseline Atom Interferometry Workshop, CERN, March 2023). Like the summary of the first workshop (Abend et al. in AVS Quantum Sci. 6:024701, 2024), this document records a critical milestone for the international atom interferometry community. It documents our concerted efforts to evaluate progress, address emerging challenges, and refine strategic directions for future large-scale atom interferometry projects. Our commitment to collaboration is manifested by the integration of diverse expertise and the coordination of international resources, all aimed at advancing the frontiers of atom interferometry physics and technology, as set out in a Memorandum of Understanding signed by over 50 institutions (Memorandum of Understanding for the Terrestrial Very Long Baseline Atom Interferometer Study).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗